Inter-m V2-5000 Operation Manual

Operation Manual
Professional Power Amplifier
V2-5000
PROFESSIONAL POWER AMPLIFIER
Welcome
Welcome
A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
This symbol is int ended to ale rt the user to the
CAutION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.
*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.
Connection to speakers should be performed by a skilled person. *Do not install this equipment in a confined space such as a book case or similar unit. *This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus. *This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.
*
CAutION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOtE *This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
presence of uninsulated “dangerous voltage” within the product’s enclosur e that ma y be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is int ended to ale rt the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre inséré es à fond sans en lai sser aucune par tie à découvert.
PROFESSIONAL POWER AMPLIFIER
Contents
Contents
Unpacking .......................................................................................................................................2
Short Form Instructions .................................................................................................................2
Installation
Environment....................................................................................................................................3
Important Safety Instructions.............................................................................................................3
Description.......................................................................................................................................4
Features............................................................................................................................................4
Front Panel ......................................................................................................................................5
Rear Panel .......................................................................................................................................7
Applications
Stereo Installation............................................................................................................................9
Parallel Installation ..........................................................................................................................9
Bridge Mono Installation ................................................................................................................10
Linked Installation..........................................................................................................................10
Connections..................................................................................................................................11
Stereo/Parallel Connection ............................................................................................................12
Bridge Mono Connection ...............................................................................................................12
Block Diagram ..............................................................................................................................13
Specifications ................................................................................................................................14
Service
Procedures....................................................................................................................................16
Schematic.....................................................................................................................................16
Parts List .......................................................................................................................................16
Variations and Options ...............................................................................................................16
Warranty .......................................................................................................................................16
V2-5000
1
PROFESSIONAL POWER AMPLIFIER
Unpacking
Unpacking
Please take a few minutes to read this manual to familiarize yourself with important information regarding installation, product features, and operation.
As with most electronic devices, original packaging (or equal) is required in the unlikely event that the product needs to be returned for servicing.
Short Form Instructions
Short Form Instructions
1. Do not connect the AC power until step 6. The ac mains power switch should be in the off position.
2. Adjust both of the level controls to the fully attenuated position(turn fully counter-clockwise).
3. Connect an appropriate line level input signal to the balanced XLR connector marked inputs.
4. Move the mode selector to the desired position. The Stereo position is the most common.
5. Connect the outputs to the speaker load according to the mode of operation determined in the previous step.
6. With the ac mains power switch in the off position, connect to an appropriate AC source.
7. Depress the ac mains power switch to the on position. The indicator ‘POWER’ will illuminate dimly and then fully after a few seconds.
8. The product is ready for operation. Slowly increase the level control to the desired operating level. Avoid illuminating the clip indicator and do not apply too much power to the speakers.
9. Operate the product and the system in a manner which does not illuminate the clip warning indicator.
2
V2-5000
PROFESSIONAL POWER AMPLIFIER
S
3125A
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
S3125A
V2-5000
3
PROFESSIONAL POWER AMPLIFIER
Description
Description
- A 2U rack space, 2 channel amplifier capable of 5000W into 4 load(bridged mono).
Features
Features
- 2Ω-load stable per channel, 4Ω-load stable in bridged mono
- 2U rack space
- Switch mode power supply available for high efficiency and low weight
- Forced air cooled(front panel intake, rear panel exhaust)
- Front panel indicators for output signal, clip, protect and power
- Rack ears for permanent installation in a standard 19”(rack mount width) enclosure
- Selectable high pass filter on each channel-clip limiter circuitry
- Gain selectable switch for both channel
- Front removable dust filters
4
V2-5000
Front Panel
1 3 42 5 76
Front Panel
PROFESSIONAL POWER AMPLIFIER
1. HANDLES
These are provided for easy transporting and installing into equipment enclosures or racks.
2. SCREW FOR DUST FILTER REMOVAL
To avoid unnecessary dust particles being drawn into amplifier, a removable dust filter has been fitted to the front panel.
3. LEVEL CONTROL
This control adjusts the level(amplitude) of the input signal for each channel. In stereo or parallel mode the knobs will determine the signal level independently for each channel. In the bridged mono mode only channel A knob will be determine the signal level, while channel B disabled.
4. LEVEL INDICATOR
These indicators should illuminate during normal operation when there is an output signal.
5. PROTECTION/CLIP INDICATOR
This warns of a problem when illuminated. Reduce the level of the device which supplies signal to the amplifier or reduce the level control(s) on the amplifier. This should not be continuously illuminated during normal operation, but may flash occasionally. Also this indicates protection occurred like the amplifier over heated, output shorted, over loaded and unexpected DC voltage output, which result the amplifier shutdown. When protection released, the amplifier should be recovered.
6. POWER INDICATOR
This confirms the amplifier is switched on and receiving AC mains power when illuminated. When switched on, the indicator is illuminated dimly for stand-by and then fully illuminated with prot/clip indicator for mute status, after that, only this illuminated fully activating the amplifier.
V2-5000
5
PROFESSIONAL POWER AMPLIFIER
7. POWER SWITCH
he position of this switch determines whether the AC mains power is on or off. The power-on status is confirmed by
T the illuminated power indicator. Amplifiers are always the last item in a system to be turned on. It is generally a good idea to reduce the level controls before applying AC mains power.
6
V2-5000
Rear Panel
P
USH
PUSH
INPUT A
I
NPUT B
CH A CH B
CH B
CHANNEL B
CHANNEL A
Rear Panel
PROFESSIONAL POWER AMPLIFIER
1. AC CORD
Connect this product to an appropriate AC main power source.
2. OUTPUT CONNECTORS
4 Pole speaker sockets are provided. Bridged mono operation requires a different method of connecting the speaker cables than stereo operation. Be sure that the amplifier is in the correct mode before connecting the speaker load. Please refer to the output connection drawings.
3. MODE SELECTOR SWITCH
Move this switch to select the stereo, parallel or bridged mono position as needed for the application. The stereo mode is most common. Channel A input provides signal through the amplifier to the channel A output. The channel B input provides signal through the amplifier the channel B output. The parallel mode uses the channel A input provides signal through the amplifier to both the channel A and channel B outputs. No input will be supplied to channel B in the Parallel mode. The bridge mono mode combines both channels to create one larger mono channel. Input signal applied to channel A will provide signal through the amplifier to the positive terminals of channel A and channel B. Do not connect any signal to the channel B input or any loads to the negative outputs.
4. VOLTAGE GAIN SELECTOR SWITCH
You can drive the amplifier with different gain structure, 1.4V, 32dB or 26dB, which is possible the amplifier to accept a various input level.
5. 3-Pin Euroblock Input Connectors
These connectors are used for balanced or unbalanced input signals. For parallel mode or bridged mode, use INPUT 1 only.
V2-5000
7
PROFESSIONAL POWER AMPLIFIER
6. Combination XLR, 1/4” TRS Input Connectors
hese connectors are used for balanced or unbalanced input signals, and are wired in parallel with the
T Euroblock connector.
7. CLIP LIMITER SWITCH
The clip limiter reduces the internal operating level of the amplifier as necessary to insure that signal peaks do not overdrive the amplifier, causing distortion or damage to the amplifier or loudspeakers. It is recommended to leave this switch to the “ON” mode to reduce distortion and help to provide protection to the loudspeakers.
8. HIGH PASS FILTER SWITCH
Select the switch position that is suited for your application the most. The off position allows full frequency range signals to reach the loudspeakers. The 30Hz position reduces the signal amplitude below 30Hz to conserve power and help protect the loudspeakers. The 50Hz position reduces the signal amplitude below 50Hz to conserve power and help protect the loudspeakers.
8
V2-5000
Applications
PUSH
PUSH
I
NPUT A
INPUT B
CH A CH B
CH B
CHANNEL B
CHANNEL A
IMX-824/832/840
PUSH
PUSH
I
NPUT A
I
NPUT B
CH A CH B
C
H B
C
HANNEL
B
C
HANNEL
A
IMX-824/832/840
Applications
ApplicationsApplications
Stereo Installation
PROFESSIONAL POWER AMPLIFIER
Parallel Installation
V2-5000
9
PROFESSIONAL POWER AMPLIFIER
PUSH
PUSH
I
NPUT A
I
NPUT B
CH A CH B
CH B
C
HANNEL
B
C
HANNEL
A
I
MX-824/832/840
PUSH
P
USH
I
NPUT A
INPUT B
C
H A CH B
C
H B
CHANNEL
B
CHANNEL
A
P
USH
PUSH
INPUT A
INPUT B
CH A CH B
CH B
CHANNEL
B
CHANNEL
A
Bridged Mono Installation
Linked Installation
Linking is possible when in Stereo/Parallel or Bridged Mono operation.
10
V2-5000
AppConnections
P
USH
12
3
COMBINATION
PUSH
12
3
COMBINATION
V2-5000 amplifiers utilize three types of professional audio connectors. For the inputs, 3-pin Euroblock connectors are utilized with their polarity clearly marked on the amplifier’s rear panel, and combination XLR and 1/4” phone jack are all wired in parallel.
1. XLR INPUTS
Balanced XLR connectors are wired as described: Pin #1 Shield Pin #2 Positive Pin #3 Negative
XLR MALE
PROFESSIONAL POWER AMPLIFIER
2. TRS INPUT
Balanced 1/4″TRS connectors are wired as described:
Tip is Positive Ring is Negative Sleeve is Shield
PHONE JACK
V2-5000
11
PROFESSIONAL POWER AMPLIFIER
CH A
CH B
CH A CH B
C
H B
CHANNEL B
CHANNEL A
CH A
CH A CH B
CHANNEL A
CH A
CH A CH B
CHANNEL A
3. OUTPUTS
Bridged Mono operation has a minimum load impedance of 4.
Stereo/Parallel Connection
Wiring Using Both Speaker Connectors
Wiring Two Speakers to the Channel A Speaker Connector
Bridge Mono Connection
Wiring a Speaker in Bridged Mono to the Channel A Speaker Connector
12
V2-5000
Block Diagrams
&+$
&+%
&+$
&+%
Block Diagram
PROFESSIONAL POWER AMPLIFIER
V2-5000
13
PROFESSIONAL POWER AMPLIFIER
Specifications
Specifications
Continuous Average Output Power Per Channel
Stereo Mode 8Ω(T.H.D 1%) 1000W (1kHz, Both Channels Driven) 4Ω
2
Bridged Mono Mode 8
4Ω(T.H.D 1%)
I
nput Sensitivity (Rated Output Power @4) Voltage Gain (Rated Output Power @4 Frequency Response
(1W @8) Damping Factor (100Hz, Rated Output Power @8Ω) T.H.D
(20Hz~20kHz, 10dB Below Rated Output Power @4) Channel Separation
(1kHz, 3dB Below Rated Output Power @8) Residual Noise less than -70dB Signal to Noise Ratio
(Rated Output Power @8 Output Circuitry 2 Step Class H Input Impedance 12 k HPF (30Hz/50Hz) 12dB/oct Indicators Prot/Clip, Signal, Power
Protection Circuitry
Cooling Variable Speed Fans, Front to Rear Air Flow
20Hz~20kHz
- 3dB point 5Hz~70kHz
, 20Hz~20kHz)
Connectors Input : XLR(Female), 1/4″TRS, 3-PIN EUROBLOCK
Operating Temperature/Humidity Temperature : -10°C~ +40°C/ Humidity : 0% ~ 90% Power Source
Power Consumption (1/8 Rated output power @4)
Weight (SET) Dimensions (SET) 482(W) x 88(H) x 407(D)mm / 19(W) x 3.5(H) x 16(D)in
V2-5000
120VAC
(T.H.D 1%) 1700W
(T.H.D 1%) 2500W
(T.H.D 1%)
) 36dB
Full Short Circuit, Thermal Protection
Power ON/OFF Muting, DC Output Protection
3400W 5000W
±0.3dB
more than 400
less than 0.05%
less than -70dB
106dB
Output : 4 Pole Speaker Socket
120VAC
12.8kg / 28.2lb
1.4V
Balanced
60Hz
16A
dB=1V
0
* Specifications and design subject to change without notice.
14
V2-5000
DIMENSIONS
440
482
88
369 39
PROFESSIONAL POWER AMPLIFIER
V2-5000
15
PROFESSIONAL POWER AMPLIFIER
Service
Service
Procedures
Ensure the problem is not related to operator error, or external system devices, Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Variations of this product exist to reflect the variations in AC power requirements throughout the world. Product supplied through local sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
16
V2-5000
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe, Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA TEL : +1-562-921-0313, FAX : +1-562-921-0370 Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149 Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
February 2012 130340
Loading...