A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
This symbol is int ended to ale rt the user to the
CAutION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.
Connection to speakers should be performed by a skilled person.
*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.
*
CAutION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOtE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
presence of uninsulated “dangerous voltage” within
the product’s enclosur e that ma y be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is int ended to ale rt the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre inséré es à fond sans en lai sser aucune par tie à
découvert.
Please take a few minutes to read this manual to familiarize yourself with important information regarding
installation, product features, and operation.
As with most electronic devices, original packaging (or equal) is required in the unlikely event that the product
needs to be returned for servicing.
Short Form Instructions
Short Form Instructions
1. Do not connect the AC power until step 6. The ac mains power switch should be in the off position.
2. Adjust both of the level controls to the fully attenuated position(turn fully counter-clockwise).
3. Connect an appropriate line level input signal to the balanced XLR connector marked inputs.
4. Move the mode selector to the desired position. The Stereo position is the most common.
5. Connect the outputs to the speaker load according to the mode of operation determined in the previous step.
6. With the ac mains power switch in the off position, connect to an appropriate AC source.
7. Depress the ac mains power switch to the on position. The indicator ‘POWER’ will illuminate dimly and then
fully after a few seconds.
8. The product is ready for operation. Slowly increase the level control to the desired operating level. Avoid
illuminating the clip indicator and do not apply too much power to the speakers.
9. Operate the product and the system in a manner which does not illuminate the clip warning indicator.
2
V2-1000/2000/3000/4000
PROFESSIONAL POWER AMPLIFIER
S3125A
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
V2-1000/2000/3000/4000
3
PROFESSIONAL POWER AMPLIFIER
Description
Description
- V2-1000
A 2U rack space, 2 channel amplifier capable of 1150W into 4Ωload(bridged mono).
- V2-2000
A 2U rack space, 2 channel amplifier capable of 1850W into 4Ωload(bridged mono).
- V2-3000
A 2U rack space, 2 channel amplifier capable of 3300W into 4Ωload(bridged mono).
- V2-4000
A 2U rack space, 2 channel amplifier capable of 4200W into 4Ωload(bridged mono).
※
The output power can be changed in relation to the AC supply voltage.
Features
Features
- 2Ω-load stable per channel, 4Ω-load stable in bridged mono
- 2U rack space
- Switch mode power supply available for high efficiency and low weight
- Forced air cooled(front panel intake, rear panel exhaust)
- Front panel indicators for output signal, clip, protect and power
- Rack ears for permanent installation in a standard 19”(rack mount width) enclosure
- Selectable high pass filter on each channel-clip limiter circuitry
- Gain selectable switch for both channel
- Front removable dust filters
4
V2-1000/2000/3000/4000
Front Panel
1342576
Front Panel
PROFESSIONAL POWER AMPLIFIER
1. HANDLES
These are provided for easy transporting and installing into equipment enclosures or racks.
2. SCREW FOR DUST FILTER REMOVAL
To avoid unnecessary dust particles being drawn into amplifier, a removable dust filter has been fitted to the
front panel.
3. LEVEL CONTROL
This control adjusts the level(amplitude) of the input signal for each channel. In stereo or parallel mode the
knobs will determine the signal level independently for each channel. In the bridged mono mode only
channel A knob will be determine the signal level, while channel B disabled.
4. LEVEL INDICATOR
These indicators should illuminate during normal operation when there is an output signal.
5. PROTECTION/CLIP INDICATOR
This warns of a problem when illuminated. Reduce the level of the device which supplies signal to the
amplifier or reduce the level control(s) on the amplifier. This should not be continuously illuminated during
normal operation, but may flash occasionally. Also this indicates protection occurred like the amplifier over
heated, output shorted, over loaded and unexpected DC voltage output, which result the amplifier shutdown.
When protection released, the amplifier should be recovered.
6. POWER INDICATOR
This confirms the amplifier is switched on and receiving AC mains power when illuminated. When switched
on, the indicator is illuminated dimly for stand-by and then fully illuminated with prot/clip indicator for mute
status, after that, only this illuminated fully activating the amplifier.
V2-1000/2000/3000/4000
5
PROFESSIONAL POWER AMPLIFIER
7. POWER SWITCH
2-Series have a combination AC switch/circuit breaker. The position of this switch determines whether the AC
V
mains power is on or off. The power-on status is confirmed by the illuminated power indicator. Also this is
used for a circuit breaker to protect AC mains power and the amplifier from abnormal operations due to
overload or malfunction. If the current flows over the circuit breaker's rating, the circuit breaker is tripped.
You can switch on after abnormal situation released and then the amplifier will be recovered. Amplifiers are
always the last item in a system to be turned on. It is generally a good idea to reduce the level controls
before applying AC mains power.
6
V2-1000/2000/3000/4000
Rear Panel
Rear Panel
PROFESSIONAL POWER AMPLIFIER
1. AC CORD
Connect this product to an appropriate AC main power source.
2. OUTPUT CONNECTORS
4 Pole speaker sockets are provided. Bridged mono operation requires a different method of connecting the
speaker cables than stereo operation. Be sure that the amplifier is in the correct mode before connecting the
speaker load. Please refer to the output connection drawings.
3. MODE SELECTOR SWITCH
Move this switch to select the stereo, parallel or bridged mono position as needed for the application. The
stereo mode is most common. Channel A input provides signal through the amplifier to the channel A
output. The channel B input provides signal through the amplifier the channel B output. The parallel mode
uses the channel A input provides signal through the amplifier to both the channel A and channel B outputs.
No input will be supplied to channel B in the Parallel mode. The bridge mono mode combines both channels
to create one larger mono channel. Input signal applied to channel A will provide signal through the
amplifier to the positive terminals of channel A and channel B. Do not connect any signal to the channel B
input or any loads to the negative outputs.
4. VOLTAGE GAIN SELECTOR SWITCH
You can drive the amplifier with different gain structure, 1V, 32dB or 26dB, which is possible the amplifier
to accept a various input level. (V2-1000/2000 Voltage Gain: 1V, 26dB, 20dB)
5. BALANCED TRS INPUT CONNECTORS
Each input channel is equipped with a TRS connector. The signal at these connectors is parallel with the XLR
input signal for linking the input signal to other amplifier.
V2-1000/2000/3000/4000
7
PROFESSIONAL POWER AMPLIFIER
6. BALANCED XLR INPUT CONNECTORS
ach input channel is equipped with a XLR connector. You can use either balanced or unbalanced
E
connectors, but recommend using unbalanced only for a short distance between equipment to avoid a noise
problem. Please refer to the input connection drawings.
7. CLIP LIMITER SWITCH
The clip limiter reduces the internal operating level of the amplifier as necessary to insure that signal peaks
do not overdrive the amplifier, causing distortion or damage to the amplifier or loudspeakers. It is
recommended to leave this switch to the “ON” mode to reduce distortion and help to provide protection to
the loudspeakers.
8. HIGH PASS FILTER SWITCH
Select the switch position that is suited for your application the most. The off position allows full frequency
range signals to reach the loudspeakers. The 30Hz position reduces the signal amplitude below 30Hz to
conserve power and help protect the loudspeakers. The 50Hz position reduces the signal amplitude below
50Hz to conserve power and help protect the loudspeakers.
8
V2-1000/2000/3000/4000
Applications
Applications
ApplicationsApplications
Stereo Installation
PROFESSIONAL POWER AMPLIFIER
Parallel Installation
V2-1000/2000/3000/4000
9
PROFESSIONAL POWER AMPLIFIER
Applications
Applications
Bridged Mono Installation
Linked Installation
In V2-Series, Linking is possible when in Stereo/Parallel or Bridged Mono operation.
10
V2-1000/2000/3000/4000
Applications
Applications
Connections
Inter-M products are wired according to professionally accepted wiring practices used throughout the world.
1. XLR INPUTS
Balanced XLR connectors are wired as described:
Pin #1 Shield
Pin #2 Positive
Pin #3 Negative
XLR MALE
PROFESSIONAL POWER AMPLIFIER
2. TRS INPUT
Balanced 1/4″TRS connectors are wired as described:
Tip is Positive
Ring is Negative
Sleeve is Shield
PHONE JACK
V2-1000/2000/3000/4000
11
PROFESSIONAL POWER AMPLIFIER
3. OUTPUTS
ridged Mono operation has a minimum load impedance of 4Ω.
B
Stereo/Parallel Connection
Wiring Using Both Speaker Connectors
Wiring Two Speakers to the Channel A Speaker Connector
Bridge Mono Connection
Wiring a Speaker in Bridged Mono to the Channel A Speaker Connector
nput Sensitivity (Rated Output Power @4Ω)
Voltage Gain (Rated Output Power @4
Frequency Response
(1W @8Ω)
Damping Factor (100Hz, Rated Output Power @8Ω)
T.H.D
(20Hz~20kHz, 10dB Below Rated Output Power @4Ω)
Channel Separation
(1kHz, 3dB Below Rated Output Power @8Ω)
Residual Noiseless than 75dBless than 73dB
Signal to Noise Ratio
(Rated Output Power @8
Output Circuitry Class AB 2 Step Class H
Input Impedance 12 k
HPF (30Hz/50Hz)12dB/oct
IndicatorsProt/Clip, Signal, Power
Protection Circuitry
Cooling Variable Speed Fans, Front to Rear Air Flow
(T.H.D 0.1%) 340W 320W550W 530W
2Ω(T.H.D 0.5%) 580W 580W900W 900W
720W700W1150W 1100W2000W 2000W 2600W 2600W
4Ω(T.H.D 0.5%)
20Hz~20kHz
- 3dB point5Hz~70kHz
Ω
, 20Hz~20kHz)
1200W 1150W1900W 1850W3200W 3300W 4000W 4200W
1.1V1V1.1V1V
Ω
)31dB33dB36dB37dB
±0.3dB
more than 380more than 450more than 400
less than 0.05%
less than 70dB
106dB
Ω
Balanced
Full Short Circuit, Thermal Protection
Power ON/OFF Muting, DC Output Protection
1000W 1000W 1300W 1300W
1600W 1650W 2000W 2100W
ConnectorsInput : XLR(Female), 1/4″TRS,
Output : 4 Pole Speaker Socket
Operating Temperature/HumidityTemperature : -10°C~ +40°C/ Humidity : 0% ~ 90%
Power Source
Dimensions (SET)482(W) x 88(H) x 407(D)mm / 19(W) x 3.5(H) x 16(D)in
* Specifications and design subject to change without notice.
V2-1000/2000/3000/4000
7A
PROFESSIONAL POWER AMPLIFIER
Specifications (U.K/Australia Version)
Specifications
V2-1000V2-2000V2-3000V2-4000
240VAC240VAC240VAC240VAC
Continuous Average Output Power Per Channel
Stereo Mode 8Ω(T.H.D 0.1%)170W280W500W650W
(1kHz, Both Channels Driven) 4Ω
Bridged Mono Mode8
I
nput Sensitivity (Rated Output Power @4Ω)
Voltage Gain (Rated Output Power @4
Frequency Response
(1W @8Ω)
Damping Factor (100Hz, Rated Output Power @8Ω)
T.H.D
(20Hz~20kHz, 10dB Below Rated Output Power @4Ω)
Channel Separation
(1kHz, 3dB Below Rated Output Power @8Ω)
Residual Noiseless than 75dBless than 73dB
Signal to Noise Ratio
(Rated Output Power @8
Output Circuitry Class AB 2 Step Class H
Input Impedance 12 k
HPF (30Hz/50Hz)12dB/oct
IndicatorsProt/Clip, Signal, Power
Protection Circuitry
Cooling Variable Speed Fans, Front to Rear Air Flow
(T.H.D 0.1%)300W500W900W1150W
Ω
(T.H.D 0.5%)500W850W1400W1800W
2
Ω
(T.H.D 0.1%)
4Ω(T.H.D 0.5%)
Ω
)31dB33dB36dB37dB
20Hz~20kHz
- 3dB point5Hz~70kHz
Ω
, 20Hz~20kHz)
650W1000W1800W2400W
1100W1700W3000W3800W
1V
±0.3dB
more than 380more than 450more than 400
less than 0.05%
less than 70dB
106dB
Ω
Balanced
Full Short Circuit, Thermal Protection
Power ON/OFF Muting, DC Output Protection
ConnectorsInput : XLR(Female), 1/4″TRS,
Output : 4 Pole Speaker Socket
Operating Temperature/HumidityTemperature : -10°C~ +40°C/ Humidity : 0% ~ 90%
Power Source
Dimensions (SET)482(W) x 88(H) x 407(D)mm / 19(W) x 3.5(H) x 16(D)in
* Specifications and design subject to change without notice.
V2-1000/2000/3000/4000
15
NOTE
Service
Service
Procedures
Ensure the problem is not related to operator error, or external system devices, Once it is certain that the
problem is related to the product contact your warranty provider as described in the warranty section of this
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Variations of this product exist to reflect the variations in AC power requirements throughout the world. Product
supplied through local sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions
of warranty for a given product may be determined first by locating the appropriate country which the product
was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the
authorized Inter-M Distributor for your specific country or region.
16
V2-1000/2000/3000/4000
V2-1000/2000/3000/4000
20
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA
TEL : +1-562-921-0313, FAX : +1-562-921-0370
Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
November 2010 127364
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.