A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
This s ym bol is intende d to a lert the user to t he
CAUTION
R
ISK OF ELECTRIC SHOCK
D
O NOT OPEN
presence of uninsulated “dangerous voltage” within
he product’s encl osure that may be of s ufficient
t
magnitude to constitute a risk of electric shock to
persons.
AUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
C
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
EFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
R
ATTENTION : RISQUE DE CHOC ELECTRIQUE
NE PAS QUVRIR
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*Do not install this equipment in a confined space such as a book case or similar unit.
*Warning : To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases,
should not be placed on this apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug from the AC receptacle.
*
*
The mains plug of the power supply cord shall remain readily accessible.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This s ym bol is intende d to a lert the user to t he
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre ins ér ées à fo nd sans e n laisser auc un e pa rtie à
découvert.
Pour decon ne ct er c ompleteme nt l ’a pp areil du reseau
d’alimentation. deconnecter le cordon d’alimentation de la
prise murale.
La prise du reseau d’alimentation doit demeurer aisement
accessible.
Although your PAC-5600IRQ is neither complicated nor difficult to operate, we recommend you take a few
inutes to read this brief manual and familiarize yourself with the important information regarding product
m
features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
2
PAC-5600IRQ
Page 5
DIGITAL PA COMBINATION SYSTEM
Features
Features
- BUDGET AND SPACE SAVING INSTALLATION
The System incorporates most of the current PA functions plus Emergency and normal broadcasting abilities thus
allowing budget and space saving installation.
- DUAL BROADCASTING SYSTEM
With two-channel (300W+300W) high power amplifier built-in, dual broadcasting is possible in 24 Zones
separated by A/B channels.
- DIGITAL PROCESSING & DIGITAL AMPLIFIER
Adopting the use of CLASS-D Amplifier to reduce the total weight, power consumption and operating
temperature.
- BUILT IN VARIOUS SOUND SOURCES
The system provides FM Tuner, Media (CD/DRP/USB) player and two AUX (1,2) inputs for flexible usage.
- LIFE TIME EXTENSION OF CD MECHANISM
Has the ability to copy the music CD to the internal memory (DRP) to extend the life of the CD mechanism.
- USB HOSTING
MP3/WMA files on the USB memory can be copied to internal memory (DRP) or play directly.
- REMOTE CONTROL SUPPORT
Using a network port for remote control from the web page is possible.
※ However, CD EJECT, TUNER Memory operation including each input level volume cannot be controlled.
- SYSTEM EXPANSION
System can be expanded up to 4 units via the LINK-IN/OUT terminals while sharing the audio source. (MASTER
1 Unit, SLAVE 4 Units)
- 24 CHANNEL SPEAKER SELECT (ZONE 1~ZONE 24)
The system provides 24 channel zone selections, which can be divided into two groups for multiple broadcast
areas and with system expansion total of 120 channels can be operated.
- EQ ADJUSTMENT
EQ adjustment is possible with built-in DSP.
- REMOTE MIC CONNECTION
Maximum of four remote MICs can be connected to one unit of the system, and with installation of key pad one
of the four units can be used up to maximum of 120 channels.
- BUILT IN MONITOR SPEAKER
One can monitor the broadcast content with a built-in monitor speaker.
PAC-5600IRQ
3
Page 6
DIGITAL PA COMBINATION SYSTEM
- EMERGENCY POWER AND BATTERY CHARGING
System has battery charge connect terminal for battery charge to provide emergency power.
- FIRE DETECTION AND EMERGENCY BROADCASTING
The system provides 24 channel sensor input terminals for automatic fire alarm broadcasting. It also provides
the recording function of personalized alarm message.
- CHIME AND SIREN
Built-in Chime (4 Scale, 2 Scale) and Sire (Continuous Wave) can be used to broadcast in the event of an
emergency. Also users can change the Siren and Chime.
- INCREASED INPUTS MIC/LINE
System has 5 MIC/LINE input jacks that can be selected by a switch, phantom power (DC 24V) is also supplied
for enhanced compatibility.
- BUILT IN EM MICROPHONE (CONDENSER MICROPHONE)
EM microphone is built-in to the front panel making emergency broadcast a simple task.
- MP3 / WMA SUPPORT
Unit supports MP3/WMA and CD-DA.
- PRE-PROGRAMMED BROADCASTING
Broadcast can be pre-programmed by either PC TIMER or stored source.
Pre-Program Maximum 50/60Holiday Maximum 30 (Stored Source, PC TIMER).
(Pre-Programs can be controlled by broadcasting web pages)0
- RACK MOUNT
Rack mount bracket is included with the unit.
- SPEAKER LINE CHECK FUNCTION
Check connected speaker for functionality.
- BATTERY CHECK FUNCTION
Check the condition of the battery.
- NETWORK AUDIO STREAMING FUNCTION
Through Network, all the audio sources of AUDIO SERVER(PAC-5600IRQ) can be transmitted to LOCAL
ZONE(PSI-5240IRQ)
- STAND ALONE FUNCTION
Without a PC, reserved broadcast, audio streaming. Time and IP setting are available.
4
PAC-5600IRQ
Page 7
Front Panel
AUX 2AUX 2
TUNERTUNER
MAXMAX
MINMIN
MAXMAX
MINMIN
AUX 1AUX 1
MAXMAX
MINMIN
MIC MIC // LINE 2 LINE 2
MAXMAX
MINMIN
MIC MIC // LINE 1 LINE 1
MAXMAX
MINMIN
MAXMAX
MINMIN
MEDIAMEDIA
REPEAT
MEDIA FUN. INFO.
RANDOM
COPY DELETE
T
REBLEMID
-
B
ASS
0
-0-
+++
0
5V , 0.5A
PAC-5600IRQ
Front Panel
DIGITAL PA COMBINATION SYSTEM
1. POWER SWITCH
Switch turns the unit On or Off.
2. GROUP SELECT BUTTON (GROUP – A, GROUP – B)
Group A/B speaker zone select/deselect button.
3. NOR / EM BUTTON
Normal or Emergency select button.
※ Normal : Green LED, Emergency : Red LED
4. SPEAKER ZONE SELECT BUTTON (ZONE 1 ~ ZONE 24)
Group A/B Speaker Zone select button. LED will light when turned on.
※ Group A : Green LED, Group B : Orange LED, Emergency : Red LED
5. SIREN BUTTON (SIREN 1, SIREN 2)
Continuous Siren (SIREN 1), Wave Siren (SIREN 2).
6. MONITOR SPEAKER SELECT BUTTON (MONITOR A/B)
The Button is used to monitor Speaker Outputs of Group A or B.
1) Press button in succession to change. Group A (Green LED) → Group B (Orange LED) → Off.
2) Hold the button down to change the output level (Low/High).
7. CHIME SELECT BUTTON
4 Scale or 2 Scale chime button, useful before and after the broadcast.
※Note: MIC Function must be on to run a chime.
PAC-5600IRQ
5
Page 8
DIGITAL PA COMBINATION SYSTEM
8. EMERGENCY BROADCAST TEST BUTTON (EM TEST)
Test button to confirm the broadcast sound in the event of fire. In EM (Emergency) mode press and hold the
utton down to broadcast stored source and press down again to cancel the playback. You can also select
b
separate speaker ZONE at this time.
9. BGM INPUT INDICATOR LED
The LED displays the currently selected BGM input and are divided into groups A and B.
10. BGM INPUT SELECT BUTTON (FUN.)
Select desired input source to either Group A or B. Changes in the order of TUNER → MEDIA → AUX1 →
AUX2 each time the button is pressed.
11. MIC/LINE SELECT BUTTON (A, B) AND INDICATOR LED
MIC/LINE select button. LED will light when pressed.
※NOTE: MIC/LINE 1 has the priority over MIC/LINE 2.
Adjusts the input volume levels of MIC/LINE 1, MIC/LINE 2, AUX1, AUX2, TUNER, and MEDIA
(CD/USB/DRP).
14. MASTER VOLUME CONTROL
Adjust main volume of the system. Depending on the selection (A, AB, B) control method may change.
15. SELECT VOLUME CONTROL BUTTON (A, AB, B)
Speaker output level for each Group can be adjusted independently.
- A Button: A Group only
- B Button: B Group only
- AB Button: A and B together
16. CD SLOT
Insert CD into the slot.
17. EJECT BUTTON
Eject the CD.
18. USB TERMINAL
Terminal is to connect the USB. MP3/WMA files can be played and can also COPY the files from USB to
DRP.
19. EMERGENCY MIC (EM MIC) AND OPERATION SWITCH (MIC SW)
Built-in condenser microphone is used for EM (Emergency Broadcast) during FIRE. In EM mode, hold down
the (MIC SW) to operate.
6
PAC-5600IRQ
Page 9
DIGITAL PA COMBINATION SYSTEM
20. MEDIA FUN. BUTTON
MEDIA (CD/USB/DRP) select button. Each time the button is pressed, changes in the order of CD → USB →
RP.
D
- CD Mode: CD Play
- USB Mode: Play files stored in USB
- DRP Mode: Play files stored in the internal memory
21. INFO. BUTTON
- Access additional features of the system.
※Please refer to the “Additional Information” section.
22. RANDOM BUTTON
Play random selections.
23. REPEAT BUTTON
Repeat play selected file.
24. COPY BUTTON
Start copy CD, USB files to the DRP.
※Note : Due to copyright laws, cannot copy files to CD/USB from DRP.
25. DELETE BUTTON
Button to delete the files stored in the DRP.
26. DISPLAY WINDOW
A window that displays the current operating system information.
◀◀(▼
27. I
- MEDIA (CD/DRP/USB) Track selection button.
- TUNER Select stored radio stations.
- Used to select the system information and additional information.
28. ▶ⅠⅠ (PLAY / PAUSE) / FM MUTE BUTTON
- MEDIA (CD/DRP/USB) Play or Pause. Press ▶ll once to Play and once more to Pause.
- In TUNER Mode it is used to MUTE the weak signal stations.
◀◀(▼
29.
- MEDIA (CD/DRP/USB) Fast Forward or Rewind Button.
- In TUNER Mode, used to seek stations. Press once to move one step or press and hold to tune
automatically.
PRESET) / ▶▶I (PRESET▲) BUTTON
TUNING) /
▶▶
(TUNING▲) BUTTON
30. ■(STOP) / MEMO BUTTON
- MEDIA (CD/DRP/USB) Stop Play.
- MEMO: In TUNER Mode, used to store stations in Memory.
PAC-5600IRQ
7
Page 10
DIGITAL PA COMBINATION SYSTEM
31. NUMBER BUTTONS (0~9)
Number buttons are used to enter numbers to search for tracks and to enter radio frequencies.
32. SYSTEM OPERATION INDICATOR
Displays the system operations such as Emergency Broadcast (EM), Fire (FIRE), reserved broadcast (PC),
remote microphone broadcast (RM) and general broadcast (BGM).
8
PAC-5600IRQ
Page 11
Rear Panel
NETWORK
PC TIMER
MAIN POWER
SERVICE
POST-OUT A
POST
-
OUT B
MIC / LINE 1
SD CARD ASD CARD B
4
-WIRE ATTAMP IN
EM
REMOTE MIC (RM
-
6024)
ADDRESS ID
EM MIC
AUX 1 AUX 2 REC OUT
P
RIORITY INPUT
AC INPUT
AC FUSE
ON
OFF
P
HANTOM
MIC
L
INE
7
0V
100V
BATTERY INPUT
DC 24-27V
MAX 30A
E.M PD
EXT CHIME FIRE COM
2
4V - B24V - A
COMAMP OUT
COM - BCOM - A
+
-
RM 1
13 1415 1617 18
19 2021 2223 24
13141516171
8
19 2021 2223 24
RM 2 RM 3
LINK
FM ANT
IN OUT
RM 4
MIC / LINE 2
P
HANTOM
MIC
L
INE
P
HANTOM
MIC
L
INE
P
HANTOM
MIC
L
INE
F
AULT OUT
P
HANTOM
MIC
L
INE
A
B COM
SW
SIG
C
OM
G
+
-
S
W
+
-
G
A
B
A + - + - B
A +
-
+
-
B
CLASS 2 WIRING
OUTPUT
VOLTAGE
UNBAL
/
75
Ω
1. MASTER
2~5
. SLAVE
A B
A B
FIRE
123456
789 1011 12
123456
789 1011 12
2111314151820
2
2
2126
2
7
28
25
23 241612
134 5 67 8 91017 19
Rear Panel
DIGITAL PA COMBINATION SYSTEM
1. POWER INPUT (AC INLET)
Connect AC Power cable. Before connecting, make sure that the power voltage matches the operating
voltage of the device. (100-240VAC~ 50/60Hz)
2. DC POWER INPUT AND BATTERY CHARGE TERMINAL
The emergency power supply and battery charging port can connect DC 24V battery.
- Priority is given to AC power when both AC and DC power are both input. DC power is activated when
AC is cut off.
- When operating in emergency power mode and the battery voltage is about 20V, system operation
indicator “DC” will flash and if the voltage drops below 19V, system will be in standby mode to protect the
battery.
※Notices
1. When in standby mode due to low voltage, battery can be recharged (20V) by AC power.
2. Before connecting the battery, please check for proper polarity (+,–).
3. Please note that it may cause electric sparks when connecting the battery.
3. AC FUSE
If any problem occurs with the AC power, fuse in the unit will cut the AC power to protect the unit. When
replacing the fuse, replace with the same capacity as listed.
4. AMP IN/OUT TERMINAL
External amplifier input terminals are located in the back of the unit when separate/additional power
amplifier is needed.
※ Note: When using built-in amplifier, input/output terminals must be connected to each other.
PAC-5600IRQ
9
Page 12
DIGITAL PA COMBINATION SYSTEM
A
MP IN
AMP OUT
A +
-
+
-
B
A + - + - B
AMP IN
AMP OUT
A + - + - B
A +
-
+
-
B
External Amplifier
O
utput
1) AMP OUT (AMP OUT)
- Connect built-in amplifier (100V/33.3Ω or 70V/16.3Ω) terminals to AMP IN terminals.
Pay attention to Group A,B and polarity (+, –) connections.
-
2) AMP IN (AMP IN)
- Amplifier out terminal which can be connected to (AMP OUT) or connect to external amplifier. The input
can be used for local broadcast through speaker ZONE selection button on the front panel.
3) How to Connect
- When using only the built-in amplifier:
AMP OUT (A, B) to the AMP IN (A, B), while observing
correct polarity (+,–).
- When using both Internal and External Amplifier:
Connect an output of the two groups to the amplifier input
and the external Amplifier output to the other group input.
※Caution: When connecting an external amplifier, connect
HIGH IMPEDANCE output to AMP IN terminal.
Do not connect amplifiers rated 1200W or
higher. Also, each ZONE output must be 500W
or less.
5. EXT CHIME/ FIRE COM
EXT CHIME: Terminal to operate the CHIME2 using an external contact.
FIRE COM: FIRE SENSOR common ground input terminal.
6. 24V – A/24V – B TERMINAL
Terminal used when 4-wire Attenuator is used. SPEAKER OUTPUT terminals (+, –) and 24V – A(or 24V – B),
are used to connect COM port.
7. COM TERMINAL
24V – A/24V – B’s GND terminal.
8. CONTROL OUT TERMINAL
- EM (Emergency)
The terminal is used to control external devices when the broadcasting mode is changed to emergency
broadcast (EM/Fire/Pri), and the contact is closed regardless of speaker zone settings.
- PD (Power Distributor)
It is used to control power distributor remotely. By connecting to the remote control terminal of the PD,
contact output is made when there is a signal output in any speaker zone, regardless of broadcasting
mode (EM/Normal)
10
PAC-5600IRQ
Page 13
DIGITAL PA COMBINATION SYSTEM
192021222324
123456
COM
HOT
9. OUTPUT VOLTAGE SELECT SWITCH
100V / 70V output select switch.
NOTE : Before using the switch, make sure the speaker impedance is proper. (10.3 Please refer to the
※
nominal output impedance information).
10. SPEAKER OUTPUT CONNECT TERMINAL
The speaker output terminals of each ZONE (1~24). General Broadcast (2wire), Emergency Broadcast
(3wire), ATTENUATOR (4wire) are possible. Terminals are set from left, +, –, and E.
1) Speaker Output Signal
- Normal Broadcast: Connection to (+, –) will produce output.
- EM / FIRE Broadcast: Connection to (+, –)/(E, –) will produce EM broadcast output.
2) Speaker Connections
- When connecting the speakers, disconnect the power cord from the wall outlet. Depending on the type
of speakers in use, select the appropriate speaker terminals on rear panel.
※ ZONE OUTPUT 1~24 ZONE (Caution when connecting).
Group A, B, respectively (12 ZONE) the sum of power output is not over (300W + 300W).
11. MAIN POWER SWITCH (MAIN POWER)
The switch is used to turn On and Off the AC power.
12. POST OUTPUT Terminal (POST-OUT A/B)
Terminal is used to record sound from this unit and to connect to an external amplifier.
13. SERVICE TERMINAL
Used for maintenance/service of the unit.
PAC-5600IRQ
11
Page 14
DIGITAL PA COMBINATION SYSTEM
U
TP
1
818
[
TOP VIEW ]
DIRECT
[ CABLE COLOR ORDER ]
18
18
CROSS
[CABLE COLOR ORDER]
[
FRONT VIEW ]
8.Brown
7.W/Brown
6
.Green
5
.W/Blue
4
.Blue
3.W/Green
2
.Orange
1.W/Orange
14. TELECOMMUNICATION TERMINAL
Supports 10/100 Base-Tx as a network terminal, remote control is possible by accessing the web page.
Standard TIA/EIA 568B standard terminated CAT5 cables used to connbect the PAC-5600.
-
※ For how to use the remote control, please refer to the SOFTWARE MANUAL.
15. SD MEMORY CARD SLOT (SD CARD 1/2)
Insert SD memory card with stored emergency broadcast sound source.
※ Change the sound according to ones preferences.
※ If SD memory card is not equipped, contact signal is output from the relevant FAULT OUT terminal.
(SD CARD A - FAUTL A terminal, SD CARD B - FAULT B terminal)
16. LINE / MIC INPUTS AND INPUT SELECTION SWITCH
Usage of the input terminal is changed depending on the position selected by the input switch.
- LINE: LINE Input.
- MIC: Can be used as a general dynamic microphone input.
- PHANTOM: Condenser microphone input and provides DC 24V to the input terminal.
※MIC/LINE 1 input takes priority over MIC/ LINE 2 input.
17. FIRE SENSOR INPUT TERMINAL
Contact input terminals working in conjunction with fire receiver to output a fire emergency broadcast.
Each area has 3 input terminals to configure a group of upper, lower and or ground floor.
(Emergency Broadcast sound source is stored in SD memory card.)
12
PAC-5600IRQ
Page 15
DIGITAL PA COMBINATION SYSTEM
Fire Signal
1st floor contact
2nd floor contact
Per diagram when the fire signal is received connect so that the proper channel is activated to send
emergency broadcast.
For example: 1st floor 1-4 channels are activated. 2nd floor 1-6 channels are activated. If both 1st and 2nd
floors are activated at the same time, 1-6 channels will transmit emergency broadcast.
In the above example case when 1st and 2nd floor are connected to 1-4 channel together ① 1st floor ②
2nd floor are connected. When multiple contacts are connected to same contact take extra care to connect
each one independently.
Fire contact Macro functions can be set with web. For detailed instructions please refer to the SOFTWARE
MANUAL.
※ Note: When input comes in during standby mode, emergency broadcast system turns on and broadcasts
to pre-selected ZONE speakers.
18. REMOTE MIC CONNECT TERMINAL (RM 1 ~ RM 4)
Remote MIC (RM-6024) connect terminal. RM1~RM4 (Max 4 can be connected for use).
* PIN OUT Detail
Pin No.Functions
1RS-422 Data - RX+
2RS-422 Data - RX3RS-422 Data - TX4Live Data Input
5GND
6RS-422 Data - TX+
7Balanced Audio Output - HOT
8Balanced Audio Output - COLD
- RM1 of RM1-RM4 terminal can be expanded up to 120 locations with optional KEYPAD (RM-6012KP).
※ Note: When system is in SLAVE MODE, remote MIC function cannot be used.
PAC-5600IRQ
13
Page 16
DIGITAL PA COMBINATION SYSTEM
19. PRIORITY INPUT TERMINAL
PRIORITY INPUT terminal that accepts input signals and contact point. SW +, –. When signal is received to
he terminal, in order of preference stops the broadcast and broadcasts the signal received in PRIORITY
t
INPUT to all ZONE.
20. FAULT OUT TERMINAL
Terminal that sends information of fault in the amplifier or in speaker line. Connect of FAULT OUT terminal
will be closed in situations as following.
※ When speaker lines are shorted (Please refer to page 24 for more information of SPEAKER LINE CHECK
function.) →The contact signal is output from the FAUL OUT terminal of the relevant ZONE. (ZONE
1~12-FAULT A terminal, ZONE-13~24-FAULT B terminal)
※ IF SD card is not equipped, contact signal is output from the relevant FAULT OUT terminal. (SD CARD A-
FAULT A terminal, SD CARD B-FAULT B terminal)
※ If DC battery is not connected or misconnected, contact signal is output from FAULT OUT A and B.
21. EM MIC / SWITCH CONNECT TERMINAL (EM MIC)
Terminal is used when external MIC is used instead of EM MIC (built-in front panel). (MIC sold separately)
※ Note: When connecting external microphone, please observe the pin specifications.
22. ADDRESS SET SWITCH (ADDRESS ID)
Switch intended to specify the ADDRESS of each set for the expansion of the unit.
SET
MASTERON
SLAVE1OFFONOFFOFFOFF25~48 ZONE
SLAVE2OFFOFFONOFFOFF49~72 ZONE
SLAVE3OFFOFFOFFONOFF73~96 ZONE
SLAVE4OFFOFFOFFOFFON97~120 ZONE
※ Note: In SLAVE MODE setting, if the numbers are duplicated it may cause abnormal operations.
23. LINK IN / LINK OUT TERMINAL
The terminal is used to expand the system up to 4 SLAVE units (Total 120 ZONE) can be connected.
Configured by MASTER and SLAVE system, SLAVE will share the output of the MASTER unit.
1) LINK IN Terminal
Terminal to receive the sound source and control signals from previous system for system expansion.
- Set the ADDRESS setting switch to the proper usage (MASTER/SLAVE 1~4) of the system. Turn the
power off and turn on to apply the settings.
- System set to SLAVE is displayed as “SLAVE (1~4)” in the front display window.
- The system set to SLAVE cannot use its own sources.
※ Use UTP Direct cable when connecting LINK IN/OUT.
24. AUX1 INPUT JACKS AND CONTACTS
Ability to use AUX1 as BGM input from an external source input. Priority is same as BGM.
A - COM Contact Input, A group’s BGM will be selected to AUX1.
B - COM Contact Input, B group’s BGM will be selected to AUX1.
25. AUX INPUT TERMINAL
Multiple external source devices (CD, DECK, TUNER, etc.) can be connected and input volume adjustment is
on the front panel.
26. REC OUT TERMINAL
The terminal for recording the output of Group A,B to the external recording device.
PAC-5600IRQ
15
Page 18
DIGITAL PA COMBINATION SYSTEM
27. RESERVED BROADCAST INPUT TERMINAL (PC TIMER)
The terminal to receive audio signals from PC for playback in reserved broadcast.
28. FM ANTENNA TERMINAL (FM ANT)
Use the FM antenna supplied with the product, 75Ω coaxial cable can also be connected if the signal is
weak and produces noise.
16
PAC-5600IRQ
Page 19
Operating Method
Operating Method
1. Before using the system
1) Set all the volumes to minimum level before connecting to a wall outlet.
2) Please make sure that the speaker and the input terminals are connected properly.
In particular, make sure that the AMP input / output jacks on the rear panel are connected properly.
3) Confirm the settings of MASTER, SLAVE modes.
4) The red LED on power button on the front panel will blink and stop when the main power switch on back is
turned on.
5) Pressing the power button on front panel will turn on the display window.
6) Adjust both the input and main volume to operate the system.
2. System Operation
1) Dual Broadcasting
System can broadcast to two different areas (Group A and Group B) with unique broadcasts to each Group.
- Input selection by group
Select an input by using the input selection button (FUN) for each group.
Each time the button is pressed, input changes in the order of TUNER → MEDIA → AUX1 → AUX2.
Example) Group A: TUNER Broadcast, Group B: MEDIA (CD) Broadcast.
DIGITAL PA COMBINATION SYSTEM
☜
- Main Volume Control by Group
Use the mode selection button on the front panel to adjust the speaker output level by Group.
☞
- MIC and Chime Broadcast
• MIC broadcasting can be separate for Group A and Group B.
• Press the MIC/LINE button for a specific group to broadcast to.
☞
• Before pressing the Chime button, adjust the input volume level properly.
※Note: For Chime operation, Group must be selected using the MIC/LINE button.
➡
PAC-5600IRQ
17
Page 20
DIGITAL PA COMBINATION SYSTEM
2) How to check Emergency Broadcast Sound
• In EM (Emergency) mode press and hold EM TEST button to hear through the main and monitor
peakers.
s
3) System Remote Control Method
Please refer to the SOFTWARE MANUAL.
※PC Program, Software MANUAL can be downloaded from (www.inter-m.com).
3. FM TUNER Operation
1) How to Auto/Manual tune radio frequencies
- Use either Group A or B input button to light the LED on TUNER.
- TUNING ▼ / ▲(Frequency DOWN/UP). Use Up/Down buttons to find desired frequency.
• Auto Tune : TUNING ▼/ ▲ (DOWN/UP) Holding down the button will automatically find and tune in
the stations. Once tuned in “TUNED” will display.
• Manual Tune : TUNING ▼ / ▲ (DOWN/UP) Pressing the button briefly once will increase/decrease
the frequency by one step. If possible frequency is found “TUNED” will display and play.
- Press MEMO button and MEMORY will display along with preset number.
- Press PRESET ▼/ ▲ button or numbers (0~9) button to select preset location and pressing MEMO
button will store the frequency in the preset location.
➡
- Using above steps up to 40 stations can be stored in preset memory.
- Recall the stored stations by pressing the PRESET ▼ / ▲buttons.
➡
3) FM Antenna Installation
Find the best possible location with the best reception for the FM antenna. However, within the city,
industrial areas, or high voltage transmission lines will cause excessive noise or weak signal. In this case it
is best to install an outdoor antenna with 75Ω connecting cable.
18
PAC-5600IRQ
Page 21
DIGITAL PA COMBINATION SYSTEM
4) FM MUTE Function
No display of TUNED indicates no broadcast or weak/noisy signals. Pressing FM MUTE button will
isplay “AUTO” and bypass all weak or noisy stations.
d
➡
When the normal broadcast signal is received TUNED is displayed and the broadcast is automatically
resumed.
※Note: In some cases TUNED display will be lit due to the interference from other equipment such as CDP. In
this case, install or move the equipment away from the system.
4. MEDIA (CD/USB/DRP) Operation
1) Input select mode
- Use either Group A of B input button to light the LED on MEDIA.
- MEDIA FUN Button. Each time button is pressed, input changes in the order of CD → USB → DRP.
2) Play/Pause Function
- CD
• Able to play CD-DA/MP-3/WMA formats.
• Press MEDIA FUN button to select CD mode.
➡
• When the CD is inserted, reads the CD information and goes to standby mode displaying TOTAL songs
available.
Up to 499 songs is displayed and “NO DISC” is displayed when there is no CD present.
• ▶ll (Play/Pause) Press once to Play and once more to Pause.
• ▶ll (Play/Pause) Press again to cancel Pause and resume Play.
※Note: IF the disc is in poor condition or is a non-playback format, disc will be ejected automatically.
In this case it is not the system, please check the disc instead.
Only the 12cm size disc can be used. 8cm size disc cannot be used.
PAC-5600IRQ
19
Page 22
DIGITAL PA COMBINATION SYSTEM
- USB
• Plays the files stored in a USB memory device.
Press MEDIA FUN button to select USB mode.
•
➡
• When the USB device is inserted in the USB reader, reads the information and goes to standby mode
displaying TOTAL number of files available. If there is no USB device “NO USB” will display and “NO
FILE” when there is no file to read.
• ▶II (Play/Pause) Press once to Play and once more to Pause.
• ▶II (Play/Pause) Press again to cancel Pause and resume Play.
- DRP
• Plays the files stored in the internal memory.
• Press MEDIA FUN Button to select DRP mode.
➡
• Once in DRP mode, reads the information and goes to standby mode displaying TOTAL number of files
available.
If no files are available “NO FILE” will be displayed.
• ▶II (Play/Pause) Press once to Play and once more to Pause.
• ▶II (Play/Pause) Press again to cancel Pause and resume Play.
• Press ◀◀/ ▶▶ button to move folders.
3) REPEAT Function
Each time REPEAT button is pressed mode changes in order of REPEAT 1 → REPEAT GROUP(USB) →
REPEAT ALL → OFF.
- REPEAT 1 Function
Press the REPEAT button once “REPEAT 1” is displayed and selected song is played repeatedly.
- REPEAT GROUP Function
When REPEAT is double-clicked “REPEAT GROUP” is displayed and USB file folder is played repeatedly.
- REPEAT ALL Function
Press REPEAT three times “REPEAT ALL” is displayed and the entire disc is played repeatedly.
- OFF Mode
Disc is stopped after playing the entire disc once without repeat.
4) RANDOM Function
Songs are played in random order.
- In stop mode press RANDOM and “RANDOM” is displayed. Press ▶II (Play/Pause) button to play in
random order.
- Repeat playback is possible in REPEAT mode.
- Press RANDOM button once more to cancel the mode.
20
PAC-5600IRQ
Page 23
DIGITAL PA COMBINATION SYSTEM
5) COPY Function
Ability of copying CD and USB source materials to the DRP(Internal Memory).
- CD COPY
Ability to copy the contents of the CD to the DRP. CD playback and COPY is done at the same time.
•
• Using this feature can greatly extend the life of the CD mechanism as playback is sourced from internal
memory.
• Insert CD and press COPY button to switch to the CD COPY mode.
• Press I◀◀(▼PRESET) / ▶▶I (PRESET▲) to select the folder to be stored.
• After selecting the file to COPY, press ▶II (Play/Pause) (screen shot below). Press ▶II (Play/Pause)
once more to start the COPY function. (New file will over-write existing file.)
➡
- USB COPY
• Ability to copy the contents of USB to the DRP. No playback during COPY and the files are copied
sequentially.
• Insert USB and double-click the COPY button to switch to the USB COPY mode.
• Press I◀◀(▼PRESET) / ▶▶I (PRESET▲) to select the folder to be stored.
• After selecting the file to COPY, press ▶II (Play/Pause) (screen shot below). Press ▶II (Play/Pause)
once more to start the COPY function.
➡
※Notice: 1. When COPY starts the existing files stored in the folder will be deleted.
2. Playback order will be same as USB stored order. If specific playback order is needed,
create a new USB source with playback order before using COPY function.
➡
➡
- Press MEDIA FUN button to switch to DRP mode to verify the COPY content.
- Pressing the ■ (Pause) button during COPY will stop the copy function and save only up to the last
completed tracks.
PAC-5600IRQ
21
Page 24
DIGITAL PA COMBINATION SYSTEM
6) DELETE (File Delete) Function
Function to delete unnecessary files from the DRP (internal memory).
Folder Delete
-
• Press MEDIA button to select DPR.
• Pressing DELETE button will change to delete mode and “FOLDER1” is displayed.
• Press ▶▶ (SEARCH UP) button to select folder (FOLDER1~6) to be deleted.
• Select the folder to delete and press DELETE button, as shown below and use I◀◀ / ▶▶I button to
delete only the selected TRACK.
• In “DELETE TRACK” mode pressing DELETE button to use numeric(0~9) buttons to select delete TRACK
is possible.
• Select the TRACK to delete and press DELETE button, as shown below, press DELETE once more to
delete the TRACK.
➡
- FORMAT
• In “FOLDER1” mode press ▶▶(SEARCH UP) button to select the FORMAT as shown below.
• After selecting FORMAT, press DELETE button, as shown below, and press DELETE to start the FORMAT
.
22
PAC-5600IRQ
➡
Page 25
5. Add-on Operation Methods
1) System Version Display Function
isplay the system version.
D
- Press INFO button and press I◀◀/ ▶▶I button to verify “VER. #.#.#.#”.
2) BUZZER ON/OFF Setting
Able to turn On/Off the BUZZER sound each time a button is pressed.
- Press INFO button and press I◀◀/ ▶▶I button to select “BUZZER ON.
- Use ▶II button to select ON/OFF option. (Default setting is ON position.)
DIGITAL PA COMBINATION SYSTEM
3) AUTO PLAY Function Setting
Function to auto-play a CD and stop when the main power is turned on.
- Press INFO button and press I◀◀/ ▶▶I button to select “AUTOPLAY ON”.
- Use ▶II button to select ON/OFF option. (Default setting is ON position.)
※ NOTE: To use the AUTO PLAY, before powering off, selection must be set to CD.
4) System IP information display
Display units’ IP information.
- Press INFO button and press I◀◀ / ▶▶I button to display system IP information.
(Default IP address is 192.168.1.99)
On the IP address indicated display, ▶Press ⅠⅠ button to make number 192 blink.
Set an IP address by pressing numbers on the pad and press I◀◀/ ▶▶I buttons to change IP address
of other digits.
- ▶ Press ⅠⅠ button and will be displayed for 3 seconds and set IP address will be
saved. Once saved, user set IP address is displayed.
PAC-5600IRQ
23
Page 26
DIGITAL PA COMBINATION SYSTEM
- Press button to go back to the initial screen.
Return to the initial screen by pressing INFO button and not save the set IP address.
-
5) SERVER ON/OFF
This function turns the SERVER on and off.
- Press INFO button and press I◀◀ / ▶▶I button to check “SERVER ON/OFF”.
- ▶ Select “SERVER ON/OFF” with II button. (Basic set up is SERVER OFF.)
- Press or INFO button to go back to the initial screen.
※To send audio while BGM is broadcasted, put PAC-5600IRQ on “SERVER ON“ mode. It is
automatically switched to “SERVER ON“ when EM, FIRE, RM, TIMER is broadcasted.
6) SPEAKER LINE CHECK Function
Function to check if the speaker line is connected properly.
- CONFIRM: Test to store the current speaker line connect state.
• Press INFO button and press I◀◀/ ▶▶I button to select “SPEAKER CONFIRM”.
• Press ▶II button in “SPEAKER CONFIRM” status and it measures impedance value of ZONE 1~24
gradually.
• After the measurement of each ZONE, LED status displays of each ZONE is displayed.
STATUSLED COLORINFORMATION
1OPENLED OFFSpeakers are not connected
2SHORTRED LED ONShorted or Output Overload
3NORMALGREEN LED ONGood working order
• Press ▶II button to save the settings and return to the original state.
24
PAC-5600IRQ
Page 27
DIGITAL PA COMBINATION SYSTEM
- TEST: Displays the status of the line in comparison to the stored value from CONFIRM test.
• Press INFO button and press I◀◀/ ▶▶I button to select “SPEAKER TEST”.
• In “SPEAKER TEST” mode, pressing ▶II will display blinking “LINE” in the system operation indicator
and measure impedance value of ZONE1~24 sequentially.
• Once meacuring speaker connected ZONE is finished, LED is displayed on the ZONE that has gone
through measurement.
Press ▶II button in “SPEAKER TEST” status to measure impedance of the speaker connected ZONE. (It
measures by comparing impedance value that is confirmed from “SPEAKER CONFIRM” But, if not
“SPEAKER CONFIRM” before “SPEAKER TEST”, “ERROR is displayed on the display and it
malfunctions. Once it is “SPEAKER CONFIRM”, it operates in order, so make sure it is “SPEAKER
CONFIRM” before “SPEAKER TEST”)
STATUSLED COLORINFORMATION
1OPENGREEN LED BLINKSpeakers are not connected
2SHORTRED LED BLINKShorted or Output Overload
3NORMALLED OFFGood working order
4ABNORMALORANGE LED BLINKAbnormal. Checking is necessary
• Press ▶II button to save the settings and return to the original state.
- After the line test, in case of SHORT conditioned ZONE, ZONE button will not work. ZONE button will
only work in NORMAL status state.
- During CONFIRM or TEST, pressing ▶II button will cancel CONFIRM or TEST operations.
7) Battery Check Function
Check the currently connected emergency battery’s condition.
- CONFRIM: To check and store the battery condition as a reference.
• Push INFO button and push I◀◀/ ▶▶I button to select “BATTERY CONFIRM”.
• At “BATTERY CONFIRM” push ▶II button and “BATT” will flash and start the CONFIRM process.
• When the operation is complete, it will display “CONFIRM OK” and if process failed, “CONFIRM
ERROR” will be displayed.
PAC-5600IRQ
25
Page 28
DIGITAL PA COMBINATION SYSTEM
※Notice
1. During the installation new battery should be used to perform CONFIRM check.
2. Test the battery after the installation and when the battery is fully charged.
3. Accurate measurement can only be achieved when there was no change (Types of Cable, Length,
etc) and no replacement of cable or reconnecting of the battery, otherwise TEST ERROR may occur.
4. If battery is not connected or malfunctioning, contact signal is output from FAULT OUT A and B
terminal.
- TEST: at CONFIRM system will compare stored value and display the status of the BATTERY.
• After pressing INFO button select I◀◀/ ▶▶I button to select BATTERY TEST.
• Pressing ▶II during “BATTERY TEST” mode will display blinking “BATT” and TEST will commence.
• Upon completion of TEST following will be displayed.
DisplayCondition
1GOODThe Best Condition.
2NOT BADPeriodic CHECK is necessary.
3BADReplace the battery.
- Automatic battery checkup: Automatic checkup of emergency battery once in 10 minutes.
• Press INFO. button and I◀◀ / ▶▶I button to select “BAT AUTO OFF(ON)”.
(Default is BAT AUTO OFF)
- Use ▶II button to select “BAT AUTO ON/OFF”. (Default is BAT AUTO OFF)
⬅➡
- BAT AUTO ON: It automatically checks the battery once in 10 minutes.
• If battery is not connected or malfunctioning, contact signal is output form FAULT OUT A and B
terminal.
26
PAC-5600IRQ
Page 29
DIGITAL PA COMBINATION SYSTEM
• When the battery is connected properly, contact signal cannot be output from FAULT OUT A and B
terminal.
BAT AUTO OFF: It does not automatically check the battery once in 10 minutes.
-
• If battery is not connected or malfunctioning, contact signal is output form FAULT OUT A and B
terminal
8) Set Current Time
- This function is to set current time of the device.
- Press INFO button and press I◀◀ / ▶▶I button to check current time.
When on above screen, the year (15) blinks when ▶II button is pressed. With this
numberson the pad, setting time is available. Then press I◀◀/ ▶▶I button to change other options such
as months, date, AM/PM and the time.
※ Use number 0 on the number pad to set AM/PM.
- After time is set, ▶Press II button and will be displayed for 3 seconds and changed
time is saved.
※ Time setting is available until 20991231 PM 11:59.
When the data is saved appropriately, set time is displayed.
- Press button to go back to the previous screen.
- Return to the initial screen by pressing INFO button and not save the set IP address.
9) TIMER ON/OFF
- This function is to make reserved broadcasts. Maximum of 50 reserved broadcasts are available.
(Reserved sound sources can only be set in DRP. USB and CD etc. cannot be set.)
- When operating simultaneously with WEB set reserved broadcast (TIMER), WEB set reserved broadcast
has its priority.
- Press INFO button and press I◀◀ / ▶▶I button to check “TIMER ON/OFF”.
- ▶ Select “TIMER ON/OFF” with II button. (Default setting is TIMER OFF.)
- Press or INFO button to go back to the initial screen.
※ Default setting is TIMER OFF.
10) TIMER LIST Checking Function
- This function is to check currently set TIMER LIST.
- Press INFO button and press I◀◀ / ▶▶I button to check “TIMER LIST”.
- Without any reserved TIMER, shows on the screen.
PAC-5600IRQ
27
Page 30
DIGITAL PA COMBINATION SYSTEM
- With reserved TIMER, the sign above shows on the screen.
- Press I◀◀ / ▶▶I button to check other “TIMER LIST”.
- On the left screen, press ▶II button to check TIMER reserved time.
- On the screen of reserved time displayed, use ▶▶I button to check reserved date and source.
- On reserved time, date and source screen, use ▶II button to change reserved time, date and source.
- Press button to go back to the previous screen.
OTAL 10 is the number of reserved broadcasts the user set in TIMER
T
setting. Maximum of 50 reserved broadcasts are available.
11) TIMER Change Function
- This function is to change user set reserved time, date and source of TIMER.
- On the left screen, use ▶II button to check TIMER reserved time.
- On the TIMER reserved time displayed screen, use I◀◀/ ▶▶I button to check reserved date and source
etc. After moving to the items that needs to be changed, press ▶II button to adapt the changes.
- In the left screen, press ▶II button to make AM(or PM) blink. With I◀◀ /
▶▶I button and the number pad, such options as
AM/PM, time and minutes are adjustable. After making the change, press
▶II button to move to the screen where you can change reserved dates.
※ Use 0 on the number pad to set AM/PM.
- Return to the previous screen by pressing button and not save the reserved time.
- Return to the initial screen by pressing INFO button and not save the reserved time.
- On the left screen, with I◀◀/ ▶▶I button and 0 on the
number pad, modify to show O signal under the
- Return to the previous screen by pressing button and not save the reserved date.
- Return to the initial screen by pressing INFO button and not save the reserved date.
28
PAC-5600IRQ
date you want. After the reserved date is changed, press ▶II button to
move to the screen where you can change the reserved source.
Page 31
DIGITAL PA COMBINATION SYSTEM
- On the left screen, with I◀◀ / ▶▶I button and
umber pad, modify wanted source, volume value and track number. Press
n
▶II button and will be displayed for 3 seconds and
modified reserved source is applied properly.
※ Maximum level of volume 7 is available.
- Return to the previous screen by pressing button and not save the reserved source.
- Return to the initial screen by pressing INFO button and not save the reserved source.
12) New TIMER Setting
- This function is to set a new TIMER.
- Press INFO button and press I◀◀ / ▶▶I button to check “ADD TIMER”.
- On the “ADD TIMER“ displayed screen, press ▶II button to see “TIMER ##“ to set and press ▶II button
again to set reserved time of TIMER.
- On the left screen, press ▶II button to make AM(or PM) blink. With I◀◀ /
▶▶I button and number pad, such options as
AM/PM, time, minutes are available. After reserved time is changed, press
▶II button to move to the screen where you can change reserved date.
※ Use 0 on the number pad to set AM/PM.
- Return to the previous screen by pressing button and not save the reserved time.
- Return to the initial screen by pressing INFO button and not save the reserved time.
- On the left screen, With I◀◀/ ▶▶I button and 0 on the
number pad, modify to show O signal under the
date you want. After the reserved date is changed, press ▶II button to move
to the screen where you can change the reserved source.
- Return to the previous screen by pressing button and not save the reserved date.
- Return to the initial screen by pressing INFO button and not save the reserved date.
- On the left screen, With I◀◀ / ▶▶I button and
PAC-5600IRQ
29
Page 32
DIGITAL PA COMBINATION SYSTEM
DELETE
number pad, selecting wanted source, volume value and track number is available. Press ▶II button and
will be shown for 3 seconds and modified reserved source is applied properly.
※ Maximum level of volume 7 is available.
- Return to the previous screen by pressing button and not save the reserved source.
- Return to the initial screen by pressing INFO button and not save the reserved source.
13) TIMER Delete Function
- This function is to delete saved TIMER.
- On TIMER LIST checking function, move to displayed screen and press
button and is displayed. On this signal
displayed screen, press ▶II button and will be shown for 3 seconds and TIMER
is deleted.
- Return to the previous screen by pressing button.
14) System Initialization
Reset the IP address and web page settings.
- IP default value: 192.168.1.99
- For web page settings, reservation broadcast, please refer to the SOFTWARE MANUAL for more details.
- Although system is initialized, current time remains unchanged.
30
PAC-5600IRQ
Page 33
M
ADEINKOREA
S
N
MAIN POWER
SERVICE
POST-OUT A
POST
-
OUT B
MIC / LINE 1
SD CARD ASD CARD B
4
-WIRE ATTAMP IN
E
M
REMOTE MIC (RM
-
6024)
ADDRESS ID
E
M MIC
AUX 1 AUX 2 REC OUT
PRIORITY INPUT
ON
OFF
P
HANTOM
MIC
LINE
7
0V100V
BATTERY INPUT
DC 24-27V
MAX30A
E.MP
D
EXT CHIME FIRE COM
2
4V - B24V - A
COMAMP OUT
COM - BCOM - A
+
-
RM 1
13 1415 1617 18
19 2021 2223 24
13 1415 1617 18
19 2021 2223 24
RM 2 RM 3
LINK
FM ANT
IN OUT
PC TIMER
RM 4
MIC / LINE 2
P
HANTOM
MIC
LINE
P
HANTOM
MIC
LINE
P
HANTOM
MIC
LINE
FAULT OUT
P
HANTOM
MIC
LINE
A
B COM
S
W
S
IG
C
OM
G
+
-
S
W
+
-
G
AB
A + - + - B
A +
-
+
-
B
O
UTPUT
VOLTAGE
UNBAL
/ 75
Ω
1. MASTER
2~5
. SLAVE
A B
A B
FIRE
123456
789 1011 12
123456
789 1011 12
AC INPUT
AC FUSE
T3.15AL / 250V
CAUTION : TO REDUCE THE RISK OF FIRE R EPLA CE ONLY WI TH SAM E T YPE FU SE. UT ILI SER UN FUS IBLE DE RE CHAN GE DE MEM E T YPE .
CLASS 2 WIRING
A
UX 1
C
ONTACT
NETWORK
R
M-6024
AMP (DPA-300D)
or
or
RS-232 (PAC-5000A)
NETWORK (PAC-5600)
GROUP - A (300W)GROUP - B (300W)
P
AC-5600IRQ (SLAVE)PAC-5600IRQ (MASTER)
PSI-5240IRQ
CD-6208
CD-6208
Connections
Connections
DIGITAL PA COMBINATION SYSTEM
PAC-5600IRQ
31
Page 34
DIGITAL PA COMBINATION SYSTEM
)5217&38
0$,1&38
$'&
/(''5,9(5
&+8$57
1(7:25.
'63
0,&/,1(
0,&/,1(
0,&/,1(
0,&/,1(
0,&/,1(
$8;
$8;
3&7,0(5
/,1.,1$
/,1.,1%
(0$
(0%
50
(0B0,&
35,,1387
7,0(5
$1$08;
&'0(&+$
)0781(5
(0B0,&
'27/('
92/80(($
0,&G%9.2+0
/,1(G%9.2+0
$8;G%9.2+0
3267287B$
3267287B%
5(&287B$
5(&287B%
021,725$03021B63.
$8',2&2'(&
3+<
/,1.287$
/,1.287%
'$03
'$03
$1$08;
.(<($
/(''5,9(5
/('($
3$726(
6(1625,1387
9
6(1625,1387
; ,13876
=21(%86 =21(
9)'
3$726(
$8',2,1387$8',2287387
),5(6(1625
63($.(5287
$1$/2*
',*,7$/
$03287$03,1
5-
Block Diagram
Block Diagram
32
PAC-5600IRQ
Page 35
Specifications
Specifications
AUX INPUT (AUX IN @ 1kHz, 100V/33.3Ω, 70V/16.3Ω LOAD OUTPUT)
Rated Output (@ T.H.D 1%, GROUP A + GROUP B)300W+300W
Input Sensitivity-10 ± 3dBV
Signal-to-Noise Ratio (S/N)>75dB
EQ Control (100Hz, 1kHz, 10kHz)±10 ± 3dB
Frequency Range (1W Power Output, ±3dB)50Hz ~ 20kHz
MIC/LINE 1~5 Input (MIC/LINE @ 1kHz, POST OUT, MIC/LINE VR Max, Master VR Max, Tone VR CENTER)
MIC Input Sensitivity-55 ± 3
MIC Signal-to-Noise Ratio (S/N)>80dB
MIC Frequency Characteristics (20kHz LPF, 0±3dB)50Hz ~ 20kHz
DIGITAL PA COMBINATION SYSTEM
PAC-5600IRQ
MIC Phantom Power24V
MIC Total Harmonic Distortion (T.H.D)<0.5%
LINE Input Sensitivity-10 ± 3dBV
LINE Signal-to-Noise Ratio (S/N)>80dB
LINE Frequency Characteristics (20kHz LPF, 0±3dB)50Hz ~ 20kHz
LINE Total Harmonic Distortion (T.H.D)<0.3%
CD (TEST CD 0dB, 1kHz @ REC OUT, CD VR Max, Master VR Max, Tone VR CENTER)
Signal-to-Noise Ratio (S/N)>75dB
Frequency Characteristics (20kHz LPF, 0±3dB)100Hz ~ 20kHz
TUNER (FM, 22.5kHz MOD @ REC OUT, Tuner VR Max, Master VR Max, Tone VR CENTER)
Data Transmission MethodRS-485 Serial
Transmission Distance≤500M
Cable TypeCategory 5 UTP Cable
PAC-5600IRQ
Priority Control
EM > FIRE > PRIORITY INPUT > REMOTE MIC >
PC TIMER >SIREN, CHIME > MIC1 > MIC2~5 > BGM
Fire Sensor24 Channel
100V/33.3Ω
Speaker Output Level/Impedance
70V/16.3Ω
Operating Temperature-10°C ~ +40°C
Power SourceAC 100–240V, 50/60Hz, DC 24V
Power Consumption (1/8W)135W
Weight (SET)11.2kg/24.7lb
Dimension (SET)
440(W)×177(H)×380(D)mm/17.3(W)x 7(H) x 14.96(D) in
* Design and specification are subject to be changed for the improvement of product quality without pre notice.
※ DIMENSIONS
34
PAC-5600IRQ
Page 37
DIGITAL PA COMBINATION SYSTEM
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information
provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the
problem is related to the product contact your warranty provider as described in the warranty section of this
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions
of warranty for a given product may be determined first by locating the appropriate country which the product
was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the
authorized Inter-M Distributor for your specific country or region.
PAC-5600IRQ
35
Page 38
NOTE
36
PAC-5600IRQ
Page 39
PAC-5600IRQ
37
Page 40
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA
TEL : +1-562-921-0313, FAX : +1-562-921-0370
Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE : 719, DOBONG-RO, DOBONG-GU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
November 2015 138202
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.