This document may not be copied in whole or in part or otherwise reproduced without prior written consent
from GE Security except where specifically permitted under US and international copyright law.
DisclaimerThe information in this document is subject to change without notice. GE Security (“GE”) assumes no respon-
Trademarks and patentsGE and the GE monogram are registered trademarks of General Electric Company.
Software license agreementImportant: This end-user license agreement (“Agreement”) is a legal agreement between GE and You. Read
sibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of
this document. For the latest documentation, contact your local supplier or visit us online at www.gesecu-
rity.com.
This publication may contain examples of screen captures and reports used in daily operations. Examples
may include fictitious names of individuals and companies. Any similarity to names and addresses of actual
businesses or persons is entirely coincidental.
CyberDome II product and logo are registered trademarks of GE Security.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers
or vendors of the respective products.
the following terms and conditions carefully before installing or using this Software. This agreement provides
a license from GE to use the Software. It also contains warranty information, disclaimers, and liability limitations. Installing and/or using the Software confirms Your agreement to be bound by these terms and conditions. If You do not agree with these terms and conditions, do not install or use the Software or, if already
installed, immediately cease all use of the Software and promptly uninstall all components of the Software.
1. Definitions. The following definitions apply to this document:
a. “GE”, with respect to title to or warranty of the Software, means GE Security Inc., a Delaware corpo-
ration.
b. “Software” means the executable software or firmware programs and accompanying documenta-
tion installed on the GE products, plus any upgrades, modified versions, updates, additions, and
copies of the software furnished to Customer during the term of the license granted herein.
c. “Documentation” means all associated media, printed materials, and electronic documentation
accompanying the Software.
d. “Licensed Product” means the Software and Documentation.
e. “Customer” means the person or organization, or parent or subsidiary thereof, who uses the Soft-
ware for its intended purposes, and excludes distributors, authorized resellers, value-added resellers
and original equipment manufacturers. Customer may be referred to as You or Your, whether an
individual or a business entity of any kind.
f. “Machine” means the computer, workstation, terminal, or other hardware product on which the
Software is installed.
2. License. All rights to and in the Licensed Product, including, but not limited to, copyrights, patents,
trademarks, and trade secrets, belong to GE, and GE retains title to each copy of the Software. You agree
that GE at any time, upon reasonable notice, may audit Your use of the Software for compliance with the
terms and conditions of this Agreement. Subject to the terms and conditions of this Agreement, GE
grants You a nonexclusive license to use the Software, but only in the country where acquired, provided
that You agree to the following:
You may:
a. install and use the Software on a single Machine at one time, unless You have purchased additional
copies of the Software, in which case You may install the software on the number of Machines for which
You have purchased copies of the Software;
b. use the original copy of the Software provided to You for backup purposes.
You may not:
a. transfer or distribute the Licensed Product to others, in electronic format or otherwise, and this Agree-
ment shall automatically terminate in the event of such a transfer or distribution;
b. use the Software over a computer network;
c. sell, rent, lease, or sublicense the Software;
d. copy or modify the Licensed Product for any purpose, including for backup purposes.
3. Term. This Agreement is effective until terminated. You may terminate this Agreement by uninstalling
all components of the Software from all Machines and returning the Software to GE. GE may terminate
this Agreement if You breach any of these terms and conditions. Upon termination of this Agreement for
any reason, You agree to uninstall all components of the Software and return the Licensed Product to GE.
All provisions of this Agreement relating to (i) disclaimer of warranties; (ii) limitations on liability, remedies,
and damages; and (iii) GE’s proprietary rights, shall survive termination of this Agreement.
4. Object code. The Software is delivered in object code only. You may not alter, merge, modify, adapt, or
translate the Software, nor decompile, disassemble, reverse-engineer, or otherwise reduce the Software
to a human-perceivable form, nor create derivative works or programs based on the Software.
5. Limited warranty. GE warrants that for one (1) year from the date of delivery of the Licensed Product
(Software Warranty Period), the functions contained in the Software will be fit for their intended purpose
as described in the applicable Documentation from GE, and will conform in all material respects to the
specifications stated in such Documentation. GE does not warrant that the operation of the Software will
be uninterrupted or error-free. GE does warrant that the media on which the Software is furnished will be
free from defects in materials and workmanship under normal use for a period of thirty (30) days from the
date of delivery (Media Warranty Period). Except as specifically provided therein, any other software and
any hardware furnished with or accompanying the Software is not warranted by GE.
Your exclusive remedy under this limited warranty for nonconforming Software shall be repair or replacement of the Software, at the sole discretion of GE. To obtain a repair or replacement of nonconforming
Software, contact GE Customer Service toll-free at 888 GE Security or online at www.gesecurity.com
during the Software warranty period.
Except as expressly provided above, the licensed product is provided “as is” without warranty of any kind,
either expressed or implied, including, but not limited to, implied warranties of merchantability or fitness
for a particular purpose and, except as expressly provided above, You assume the entire risk as to the
quality and performance of the licensed product.
6. Limitation of liability. GE’s sole obligation or liability under this agreement is the repair or replacement of nonconforming software and/or defective media according to the limited warranty above. In no
event will GE be liable for damages, whether consequential, incidental, or indirect, nor for loss of data, loss
of profits, or lost savings, arising from use or inability to use the software or documentation (or any hardware furnished with the software), even if GE has been advised of the possibility of such damages, nor for
any claim by any third party.
7. General. Any materials provided to You by GE shall not be exported or reexported in violation of any
export provisions of the USA or any other applicable jurisdiction. Any attempt to sublicense, assign, or
transfer any of the rights, duties, or obligations hereunder shall be void. This Agreement shall be governed by and interpreted under the laws of the State of New York, United States of America, without
regard to conflicts of law provisions. You hereby consent to the exclusive jurisdiction of the state and federal courts located in Multnomah County, Oregon, to resolve any disputes arising under or in connection
with this Agreement, with venue in Portland, Oregon.
8. Restricted rights legend. The Licensed Product is provided with RESTRICTED RIGHTS. In the event the
United States Government or an agency thereof is granted a license, the following additional terms apply:
Restricted Computer Software, as defined in the Commercial Computer Software–Restricted Rights
clause at Federal Acquisition Regulations 52.227-19, and the restrictions as provided in subparagraphs
(c)(1) and (c)(2) thereof; and as applicable, the Government’s rights to use, modify, reproduce, release, perform, display, or disclose the Software also are restricted as provided by paragraphs (b)(2) and (b)(3) of the
Rights in Noncommercial Technical Data and Computer Software–Small Business Innovative Research
(SBIR) Program clause at DFARS 252.227-7018.
9. Acknowledgment. You acknowledge that You have read and understand this agreement and agree to
be bound by its terms. You further agree that this agreement is the complete and exclusive statement of
the agreement between You and GE, and supersedes any proposal or prior agreement, oral or written,
and any other communication relating to the subject matter of this agreement.
Intended useUse this product only for the purpose it was designed for; refer to the data sheet and user documentation.
Intended useUse this product only for the purpose it was designed for; refer to the data sheet and user documentation. For
FCC complianceThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
EMC directive
Regulatory
For the latest product information, contact your local supplier or visit us online at www.gesecurity.com.
the latest product information, contact your local supplier or visit us online at www.gesecurity.com.
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
The European Union directive on electromagnetic compatibility (2004/108/EC) requires non-European manufacturers to designate an authorized representative in the Community.
Our European representative is GE Security, Kelvinstraat 7, 6003 DH Weert, Nederland.
The European directive Waste Electrical and Electronic Equipment (WEEE) aims to minimize the impact of electrical and electronic equipment waste on the environment and human health. For proper treatment,
recovery, and recycling, return the equipment marked with this symbol to your local supplier upon the purchase of equivalent new equipment, or dispose of it in designated collection points. For more information,
visit www.recyclethis.com.
This is the GE CyberDome II Installation Manual. This document includes an overview of the product and
detailed instructions explaining:
•how to install the housing; and
•how to attach the pan/tilt/zoom (PTZ) camera assembly.
There is also information describing how to contact technical support if you have questions or concerns.
To use this document effectively, you should have the following minimum qualifications:
•a basic knowledge of CCTV systems and components; and
•a basic knowledge of electrical wiring and low-voltage electrical connections.
Read these instructions and all ancillary documentation entirely before installing or operating this product. The
most current versions of this and related documentation may be found on our website. Refer to Online
resources on page 38 for instructions on accessing our online publication library.
Note: A qualified service person, complying with all applicable codes, should perform all required hardware installation.
vii
Conventions used in this document
The following conventions are used in this document:
BoldMenu items and buttons.
ItalicEmphasis of an instruction or point; special terms.
File names, path names, windows, panes, tabs, fields, variables, and other GUI elements.
Titles of books and various documents.
Blue italic(Electronic version.) Hyperlinks to cross-references, related topics, and URL addresses.
MonospaceText that displays on the computer screen.
Programming or coding sequences.
Safety terms and symbols
These terms may appear in this manual:
CAUTION: Cautions identify conditions or practices that may result in damage to the equipment or other property.
WARNING: Warnings identify conditions or practices that could result in equipment damage or serious personal injury.
CyberDome II
viii
Installation Manual
Chapter 1 Introduction
This chapter provides an overview of your CyberDome II dome system, including
product contents and system requirements.
CyberDome II ™ is a line of advanced pan/tilt/zoom (PTZ) cameras. In addition to powerful cameras,
CyberDome II features a graphical programming interface for easier customization of camera settings, and
passcodes for protection against unauthorized access.
The CyberDome II supports many protocols to work with various keypad controllers, digital video recorders,
and other video surveillance equipment. (See Setting the protocol on page 27 for a list of supported protocols.)
Installation of the CyberDome II line of domes is simplified because all power, data, video, and alarm
connections are provided in the housing. Configuration parameters such as presets and tours unique to each
installation site are stored in the housing memory. This allows you to replace cameras or move them between
housings without having to reprogram them for each new site. As you install the first dome, you will find many
other enhancements that make installation easier and quicker.
The general steps for installing your dome include:
•preparing the mounting surface and installing the mount (if used) and housing;
•preparing the cables and wiring the housing;
•addressing the camera site, setting the protocol, and setting the termination;
•installing the PTZ camera assembly; and
•installing the dome.
Be aware that the power requirements for CyberDome and CyberDome II are different. See Power
requirements on page 5 and Cable management on page 5.
overview
Product contents
The CyberDome II consists of the following:
•Housing.
•Package containing three connectors (one 2-pin for power; one 6-pin for UTP, auxiliary data, and
RS-485; one 14-pin for alarms and contacts) and a small screwdriver. (The Select version of
CyberDome II has two connectors: a 2-pin connector for power and a 2-pin connector for RS-485
data.)
•PTZ camera assembly.
•Dome (mirror domes are shipped with cotton gloves for special handling).
•Mount (wall-mount and flush-mount versions only).
•Installation and user manuals.
You may receive the package contents in one large carton containing three boxes (four with wall-mount
versions), or if shipped individually, you may receive three (or four) separate boxes. One box will contain the
housing, connectors, and manuals. The PTZ assembly, dome, and mount (for wall-mount versions) are each
shipped in separate boxes.
Inspect the packages and contents for visible damage. If any components are damaged or missing, do not use
the unit; contact the supplier immediately. If you need to return the unit, you must ship it in the original box.
Chapter 1
Introduction
System requirements
For proper operation, adhere to the following operational, load, cable, and power requirements for
CyberDome II domes.
Operational requirements
CyberDome II contains a built-in receiver that decodes commands originating from a compatible controlling
device, such as a keypad or ASCII control software. A minimum of one controlling device is required for
operation, as shown in Figure 1. In this typical DVR system, an operator can pan, tilt, and zoom the camera,
find presets, and start preset and ShadowTours from the keypad.
Figure 1. Typical DVR system
3
CCTV
monitor
SymDec 16 DVR
(IP digital video recorder)
I/O boxKTD-405A
controller keypad
Figure 2 shows a typical network system, and Figure 3 on page 4 shows an enhanced system.
Figure 2. Typical IP system
SymNet
IP encoder/decoders
I/O boxKTD-405A
controller keypad
CCTV
monitor
CyberDome II
RS-485
Video
CyberDome II
RS-485
TCP/IP
Video
CyberDome II
4
Installation Manual
Figure 3. Typical enhanced system
CCTV monitors
KTD-440 switcher
SymDec 16 DVR
I/O boxKTD-405A
controller keypad
I/O boxKTD-405A
controller keypad
Alarm inputs
(dry contacts)
Minimum load requirements
Tab le 1 lists the load requirements for all CyberDome II dome configurations.
Table 1.Minimum load requirements of dome configurations
CyberDome II
Example site ID #15
KTD-83 data
distributor
Relay
outputs
RS-422
RS-485
Video
Alarms
Dome configurationMinimum load
Rugged, cast aluminum pendant-mount housing (with any mount)100 lb.
Heavy-duty housing (with any mount)
Swing-arm mount (with any dome except heavy duty or flush-mount)
All other dome and mount configurations50 lb.
CAUTION: For safety, the mounting surface, hardware, and procedure used for securing the dome must support
the weight of the dome, mount (if used), cables, and any structural or environmental vibration according
to local codes.
Chapter 1
Introduction
Power requirements
Every CyberDome II dome requires a 24 VAC power supply to operate the PTZ, camera, and heater/fan, if
present. The startup and running power requirements vary depending on the model (Table 2).
Table 2.Power requirements at 24 VAC (±4 VAC) operating voltage
ModelStartup powerRunning powerMinimum power source to use
Dome with fan25VA20VA40VA
Dome with 12 W heater/fan (×2)93 VA45 VA56 VA
Rugged and HD dome with 23 W heater/fan (×2)153 VA66 VA100 VA
CAUTION: Use only a Class 2 power supply of the required output rating as listed on individual units and specified.
Cable management
Follow all local codes for cable management. As a general rule, you can fill a cable conduit to a maximum of
60% of its capacity. You must maintain 40% free space. A variety of factors will determine how many cables
you can run into the dome. Capacity limitations include:
5
•number of cables
•size of the cables
•use of single-conductor or multiple-conductor cable
•use of a junction box
Figure 4 provides an illustration of the cable capacity of three typical applications. It is important to note that
all cables of the same gauge are not of the same diameter. Manufacturer, shielding, and rating affect the actual
diameter of cables of the same gauge. GE leaves the selection of the appropriate cable to the discretion of the
installer who is working with the local codes of the installation site.
Figure 4. Three acceptable typical cabling scenarios
Alarms
(multiconnector)
Power
Data
(two, daisy-chained)
3/4 in. dia.
Video
Percentage conduit fill = 38%, includes:
• Video: one 59U/6U coaxial (0.24 in. dia)
• Data: two 20 AWG UTP (0.19 in. dia)
• Power: one 16 AWG UTP (0.25 in. dia)
Power
Data
(two, daisy-chained)
Relays (two)
3/4 in. dia.
Video
Percentage conduit fill = 53%, includes:
• Video: one 59U/6U coaxial (0.24 in.dia)
• Data: two 20 AWG UTP (0.19 in. dia)
• Power: one 16 AWG UTP (0.25 in. dia)
• Alarms: 24 AWG UTP (0.11 in. dia.)
• Relays: 24 AWG UTP (0.11 in. dia.)
CyberDome II
6
Installation Manual
Cable requirements
Tab le 3 lists the requirements for the cables that connect to the dome.
Note: Use only crimp-on BNC connectors. Do not use screw-on connectors.
AlarmCat-5 cable (recommended)1,250381
Relay contactsCat-5 cable (recommended). Contacts rated for 60 W DC, 62.5 W AC with 2 A max.1,250381
Power24 VAC cable. To determine the size of cable needed for individual applications, see Power cable size and
length requirements.
Note: When using UTP cable for video and data, the wires can share the same jacket but must remain separate twisted pairs.
feetmeters
10,0003,000
1,250381
Power cable size and length requirements
Using the proper gauge of power cable will ensure proper operation and avoid voltage drops. See Tab le 4 for
the recommended cable gauge for varying maximum cable lengths and power draws.
Table 4.Recommended power cable gauges based on maximum lengths for an operating voltage of 24 VAC (±4 VAC)
Domes with
Wire gaugeDomes with fan (20 VA)
AWGmm (dia.)feetmetersfeetmetersfeetmeters
102.601569478784238490149
122.0598830149415030994
141.626201883109419459
161.293911191965912237
181.0224674123377723
WARNING: Be aware that the power requirements for CyberDome II and CyberDome are different, which may require
new cabling when replacing CyberDomes with CyberDome II domes.
12 W heater/fan (x2) (45 VA)
HD domes with
23 W heater/fan (x2) (66 VA)
Chapter 2 Housings and cables
This chapter provides instructions for installing housings and cables.
The CyberDome II PTZ is compatible with CyberDome I housings, but there are some exceptions. Although
the onscreen display (OSD) interface, including menus, will show the CyberDome II design, not all of the
CyberDome II features are supported on CyberDome I housings. The following features are not available:
•Site-tied memory
•Internal alarms
•Internal relays
•Internal wiring terminal blocks
•Advanced heater and fan system
•Lift and gain functionality.
•Up-the-coax (UTC) protocol support
Also, if you install a CyberDome II PTZ in an older CyberDome I housing, you must install a fan assembly on
the tilt arm of the PTZ. (See Fan installation on page 16 for instructions.) You may use the fan from your
CyberDome I PTZ, or call Customer Service (see Contacting us on page 38) to order a new one (part number
10556789A).
Various mounting and housing styles
There are three basic mounting styles: pendant, wall, and flush. A pendant-mount lowers a dome from a
ceiling, a wall-mount extends a dome from a wall, and a flush-mount raises a dome’s dome even with a ceiling.
See Figure 5. This document provides the instructions for all mounting styles.
Figure 5. Basic mounting styles
Pendant-mountWall-mountFlush-mount
There are four basic housing styles: flush-mount, plastic pendant-mount, cast aluminum pendant-mount, and
heavy-duty (Figure 6). Installation is generally the same for all housing styles. There are some differences,
such as how the dome rings attach to the housings (Figure 27 on page 33). Where differences exist, the
instructions will specify.
Figure 6. Basic housing styles
Flush-mountPlastic
pendant-mount
Cast aluminum
pendant-mount
Heavy-duty
Housings and cables
Chapter 2
Wiring best practices
To ensure the wires are connected properly and not at risk of being cut or frayed, follow these guidelines.
Pendant-mount wire routing
Cables run down through the cable entry hole and the dust seal. Take care to avoid damaging the dust seal
during installation.
Note: Keep service loops out of housing area when possible.
Figure 7. Side view of pendant-mount cabling and typical wall-mount
9
Cable entry hole
Dust seal
Upper bracket
Cabling
Figure 8. Top view of pendant-mount cabling
Screws
Safety chain
Wall-mount
Cables fed through
mount and housing
CyberDome II
10
Installation Manual
Flush-mount wire routing
Cables are fed through the cable entry hole in the side (or top) of the housing. Route the wires through the top
or side of the housing and around the camera bracket.
Note: Keep service loops out of housing area when possible.
Figure 9. Side view of flush-mount cabling
Upper bracket
Figure 10. Top view of flush-mount cabling
Housings and cables
Chapter 2
Pendant-mount housings
Pendant-mount and flush-mount housings require different preparation of the mounting surface and different
installation procedures of the housings. Follow the instructions given here for pendant-mount housings.
Pendant-mount housings can be mounted to a pipe to lower them from a ceiling or to a wall-mount arm to
extend them from a wall. Instructions are provided in this document for both mounting methods.
Preparing the surface for pendant-mounts
Following are the steps for preparing the mounting surface if you are mounting the housing to a pipe. If you are
mounting the housing to the GEA-102 wall-mount arm, instructions for installing the GEA-102 are available in
this manual (Installing the wall-mount arm on page 40). If you are installing one of the other mounts, refer to
the instructions that came with the mount.
CAUTION: For all installations, heed these cautions:
•Complete all installation steps before supplying power to the dome.
•To ensure proper operation of a PTZ unit, install the mount level.
•For safety, the mounting surface, hardware, and procedure used for securing the dome
must support the weight of the dome, mount (if used), cables, and any structural or environmental
vibration according to local codes. See Table 1 on page 4.
11
To prepare the mounting surface:
1.Following all local codes, install the pipe.
2.Make sure that the facility cables (data, video, and power) for the dome comply with the
recommendations provided in Cable requirements on page 6.
3.Feed the facility cables through the pipe in the mounting surface.
•Pull enough cable to make connections. You can always pull back unneeded length later.
•How many cables you have depends upon how many video, data, and power cables. See Wirin g on
page 19.
Installing the housing
With the pipe or mount now installed, install the housing.
If you are installing the housing outdoors and onto a pipe, you must install the rubber water-sealing boot that
provides an additional layer of water protection. Applying PTFE thread sealing tape (for example, Teflon
tape) to the pipe is required as a first layer of protection.
CAUTION: Avoid getting rain or moisture in the housing so that the electronic components on the PCBs are
not damaged.
To install the housing to a pipe or mount, see Figure 11 on page 12 and do the following:
®
1.If you are installing the housing outdoors and onto a pipe:
CyberDome II
12
Installation Manual
a.Spray the pipe with soapy water.
b.For outdoor applications, slide the rubber boot onto the pipe, above the threads.
c.Wrap the pipe threads with the supplied PTFE thread sealing tape in the direction that the dome
will screw onto the pipe. Overlap the tape and cover the threads.
2.Hold the housing up near the pipe or mount. If you installed the GEA-102 wall-mount arm, make sure
that the safety chain is securely attached (GEA-102 wall-mount arm on page 40).
3.Feed the facility cables through the dust seal in the top of the housing. Allow enough cable length to
make connections. Figure 8 on page 9 shows how the cables run through the housing.
CAUTION: For safety, the mounting surface, hardware, and procedure used for securing the dome must support the
weight of the dome, mount (if used), cables, and any structural or environmental vibration according to local codes.
See Table 1 on page 4.
4.Attach the housing to the pipe or mount.Slide the rubber boot down the pipe and fit it securely over the
housing’s flange.
•For pipe installations, thread the housing onto the pipe. If necessary, first turn the housing
counterclockwise to compensate for the cable twisting.
Note: Do not overtighten the plastic housing on the pipe mounting or the housing will crack and leak.
•For wall-mount installations, use the fasteners that were provided with the mount.