Content
Introduction 2
Programming 3
Call up the camera OSD menu 3
Menu tree 4 Configuration 5
System Info 5 Dome Settings 5
HD-TVI 1080P Non-IR Dome Camer as 2 HD-TVI 1080P IR Dome Cameras 2
System Settings 5 Camera Settings 8 Motion Parameter 11 Presets 12 Preset Tour 13 Timing Task 14 Shadow Tour 15 Privacy Mask 15 Alarm Input 16 Alarm Output 18 Clear Settings 18 Zones 18 Video Setting 19
IR Parameter 19 Restore Camera 20 Restore Settings 20 Reboot Dome 20 Language 20
TruVision HD-TVI Series 4 PTZ Dome Camera Configuration Manual 1

Introduction

This is the configuration manual for following camera models:
HD-TVI 1080P Non-IR Dome Cameras
TVP-2401 (30X, Pendant /Wall mount, PAL) TVP-2402 (30X, Surface/Flush mount, PAL) TVP-4401 (30X, Pendant /Wall mount, NTSC) TVP-4402 (30X, Surface/Flush mount, NTSC)
HD-TVI 1080P IR Dome Cameras
TVP-2403 (30X, Pendant/Wall mount, IR, PAL) TVP-4403 (30X, Pendant/Wall mount, IR, NTSC)
2 TruVision HD-TVI Series 4 PTZ Dom e Camera Configuration Manual

Programming

Once the camera hardware has been installed, the camera can be configured using a HD-TVI DVR menu.
You can also configure the camera settings via a DVR. Select the PTZ protocol
TruVision Coax and click the menu button to call up the menu.

Call up the camera OSD menu

To set up the camera:
1. Set up the camera hardware as described in the installation man ual .
2. Under Camera Settings of the DVR, access the PTZ menu and set the protocol for the TruVisi on HD-TVI camera to TruVision-Coax.
Note: The TruVision-Coax protocol will always be enabled.
3. In live view of the desired camera, click the PTZ Control icon on the live view toolbar to access the PTZ control panel.
4. To call up the camera setup menu: From the camera, press the Menu button (if present). — or — From the local live view of the DVR, select Menu from the PTZ control panel
or call Preset 95. — or — From the remote live view of the DVR, call Preset 95. The camera setup menu appears (see “Menu tree” on page 4 for the menu
structure).
5. Select the menu options: From the DVR: To select an OSD item, click the directional buttons up/down.
To adjust the value of a selected item, click the directional buttons left/right. From the camera (if it has a Menu button): To select an OSD item, push
the Menu button up/down. To adjust the value of a selected item, push the Menu button left/right.
6. Click Iris+ to enter the submenu or to confirm the selected item.
7. When the setup is complete, select Exit and click Iris+ to exit the camera OSD.
Note: You cannot exit the camera setup menu using the Menu button on the camera.
TruVision HD-TVI Series 4 PTZ Dome Camera Configuration Manual 3

Menu tree

The menu tree of the TruVision 1080P HD-TVI PTZ domes is shown below.
4 TruVision HD-TVI Series 4 PTZ Dom e Camera Configuration Manual

Configuration

This section describes how to set up the menu settings.

System Info

Display the current system information of the PTZ do me, incl udi ng mod el, address, protocol, etc.
Note:
Information on this menu cannot be edited. The temperature refers to the internal temperature of the PTZ dome.

Dome Settings

System Settings
You can check and edit the system information of the software address, baud rate, system time, etc. on the system information settings menu.
Note: Click the left and right directional button s in the PTZ control panel via the web browser of the encoder to enter the next page and return to the previous page of the submenu if more than one page is available.
Note: As TruVision recorders do not support an address greater than 255, a soft address greater than 255 will not support any protocol even though the camera supports 8190 for UTC-RS485 (Interlogix-Protocol) and 512 for DIGIPLEX and ASCII. However, you can have an address greater than 255 for legacy products that supports UTC-RS-485 (Interlogix-Protocol), DIGIPLEX or ASCII.
SOFT ADDRESS This is the address to connect and control the HD-TVI PTZ dome. It
can be used as an alternative to the hard address if, for example, the address must be above the avai lab le hard addres s .
SET SOFT
ADDRESS
SOFT BAUDRATE This is the valid baud rate for the HD-TVI PTZ dome with the soft
TruVision HD-TVI Series 4 PTZ Dome Camera Configuration Manual 5
ON: The soft address is the valid address for the HD-TVI PTZ dome.
The selectable soft address range is from 1 to 255.
OFF: This refers to the hard address. Use the DIP switch to set the
valid address for the HD-TVI PTZ dome.
address.