Interlogix S30-RJ, S25-1SLC/B-20, S30-2MLC, S35-2MLC, S30-2MLC-2 User Manual

...
Page 1
IFS SFP Tranceivers User Manual
P/N 1069181 • REV 02.00 • ISS 22AUG11
Page 2
Copyright © 2011 UTC Fire & Security. All rights reserved.
Trademarks and
patents
UTC Fire & Security.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Manufacture
r
UTC Fire & Security Americas Corporation, Inc.
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA
Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands
Version This document applies to IFS SFP Tranceivers version 00.20.
Certification
N4131
FCC compliance Class B: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
European Union
directives
2004/108/EC (EMC directive): Hereby, UTC Fire & Security declares that this
device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC
2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com
or www.interlogix.com
Customer support
www.interlogix.com/customer-support
Page 3
Safety Notices
The fiber optic SFP transceiver modules are equipped with a Class 1 laser, which emits invisible radiation. Read the following safety warnings carefully.
Class 1 Laser Product Complies with FDA Regulation 21 CFR 1040.10 and 1040.11
Class 1 radiation is present when the device or system is powered
up. Do not look directly into a laser aperture, as prolonged exposure
may cause eye damage.
Only trained and qualified personnel should be allowed to install or
replace these SFP modules
Page 4
Page 5
IFS SFP Tranceivers User Manual i
Content
Overview 1
Checklist 2
Installing an IFS SFP Module 3
Connecting the fiber cable 3 Removing the SFP transceiver 4
SFP Specifications 5
Appendix A 8
Fiber Optical Cable Connection Parameters 8
Page 6
Page 7
IFS SFP Tranceivers User Manual 1
Overview
Thank you for purchasing an IFS SFP transceiver. The IFS SFP transceiver can be installed into any IFS network equipment with a 100Base-FX or 1000Base­SX/LX mini-GBIC interface. This user guide provides an overview of the various IFS SFPs (also known as mini-GBIC) transceiver modules available from Interlogix. This user guide also provides instructions for installing, connecting and removing these transceivers. These SFP transceiver modules are hot-pluggable, which means you can insert and remove these modules into any IFS network equipment with a mini-GBIC port without interrupting the host system. The IFS SFP line also features a selection of environmentally hardened SFPs designed for operating in environments from -40~75 degrees Celsius.
Page 8
2 IFS SFP Tranceivers User Manual
Checklist
The SFP package should contain the following items:
• The SFP Transceiver Module x1
• This User Manual x1
If any items are missing or damaged, please consult Interlogix or the dealer/distributor from whom you purchased your SFP transceiver module.
Page 9
IFS SFP Tranceivers User Manual 3
Installing an IFS SFP Module
This section describes how to insert an IFS SFP transceiver into a mini-GBIC slot.
The IFS SFP transceivers are hot-pluggable and hot-swappable. You can insert and remove an IFS SFP transceiver in any IFS network equipment with a mini­GBIC port without having to power down the switch or media converter. As shown in Figure 1.
Figure 1: Inserting an IFS SFP tranceiver
Install the IFS SFP into an IFS network switch or media converter before connecting a cable coming from another switch, workstation or media converter.
1. Make sure both pieces of network equipment that you are connecting together are using the same media type SFP. For example: 100Base-FX to 100Base-FX or 1000Base-SX to 1000Base-SX.
2. Check to make sure that the fiber-optic cable type matches the SFP transceiver model.
• S20 Series and S25 Series optics operate with multimode OM1, OM2 or OM3 fiber. LC type fiber connectors are required.
• S30 Series and S35 Series optics operate with single mode fiber. LC type fiber connectors are required.
Connecting the fiber cable
1. Insert the duplex LC connector from the network fiber cable into the SFP transceiver.
Page 10
4 IFS SFP Tranceivers User Manual
2. Connect the other end of the cable to a device – i.e. switches with an SFP installed, fiber NIC on a workstation or a Media Converter.
3. Check the LNK/ACT LED of the SFP slot of the switch / converter. Ensure that the SFP transceiver is operating correctly.
4. Check the link mode of the SFP port to see if there is any link failure. With some fiber-NICs or Media Converters, setting the link mode to “1000 Force” or “100 Force” may be needed for proper operation.
Removing the SFP transceiver
1. Make sure there is no network activity by consulting with a network administrator before removing the SFP or use the switch or media converters management interface (if available) to disable the port in advance.
2. Gently remove the fiber optic cable connector.
3. Flip the wire handle of the SFP module out to a horizontal position.
4. Pull out the SFP module gently out of the mini-GIBIC slot with the wire handle.
Figure 2: Pull out the SFP transceiver
2
3
Caution: Never pull out the SFP transceiver module without using the pull
handle or the push bolts on the module. Directly pulling out the SFP module with force could damage the SFP module and mini-GIBIC slot of the network device.
Page 11
IFS SFP Tranceivers User Manual 5
SFP Specifications
The IFS SFP transceivers are available in the following models.
Twisted Pair SFP 1000 Base TX GigE
Part # Connector Wire Type Max Distance
S30-RJ RJ 45 Cat 5e 100M (328 ft)
Fast Ethernet 100 Base FX
Part #
Fiber Connector
# of Fibers
Fiber Type
Max Distance
Wave Length
Optical Budget (dBm)
Optical Power (dBm)
Receiver Sensitivitiy (dBm)
Operating Temperature
S20-2MLC2 LC 2 Multimode
2km
(1.2mi)
1310nm 12 -20 ~ -14 -32
0 to + 50C (32 to 122F)
S25-2MLC2 LC 2 Multimode
2km
(1.2mi)
1310nm 12 -20 ~ -14 -32
-40 to +75C (-40 to 167F)
Fast Ethernet 100 Base LX
Part #
Fiber Connector
# of Fibers
Fiber Type
Max Distance
Wave Length
Optical Budget (dBm)
Optical Power (dBm)
Receiver Sensitivitiy (dBm)
Operating Temperature
S20-2SLC20 LC 2
Single
Mode
20km
(12mi)
1310nm 19 -15 ~ -8 -34
0 to + 50C
(32 to 122F)
S25-2SLC20 LC 2
Single
Mode
20km
(12mi)
1310nm 19 -15 ~ -8 -34
-40 to +75C
(-40 to 167F)
Fast Ethernet 100 Base BX
Part #
Fiber Connector
# of Fibers
Fiber Type
Max Distance
Wave Length
TX RX
Optical Budget (dBm)
Optical Power (dBm)
Receiver Sensitivitiy (dBm)
Operating Temperature
S20-1SLC/A-20 LC 1
Single
Mode
20km
(12mi)
1310/1550nm 18 -14 ~ -8 -32
0 to + 50C
(32 to 122F)
S25-1SLC/B-20 LC 1
Single
Mode
20km
(12mi)
1550/1310nm 18 -14 ~ -8 -32
0 to + 50C
(32 to 122F)
Page 12
6 IFS SFP Tranceivers User Manual
Gigabit Ethernet 1000 Base SX
Part #
Fiber
Connector
# of
Fibers
Fiber Type
OM1 &
OM2
Max Distance
OM1/OM2
Wave
Length
Optical Budget
(dBm)
Optical
Power (dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-2MLC LC 2 Multimode
220/550m
(720/1800ft)
850nm 7.5 -9.5 ~ -1 -17
0 to + 50C
(32 to 122F)
S35-2MLC LC 2 Multimode
220/550m
(720/1800ft)
850nm 7.5 -14 ~ -8 -17
-40 to +75C
(-40 to 167F)
OM1 Multimode fiber @ 200/500MHz-km
OM2 Multimode fiber @ 500.500MHZ-km Laser Rated for GbE LANs
Gigabit Ethernet 1000 Base SX
Part #
Fiber
Connector
# of
Fibers
Fiber Type
OM3
Max
Distance
OM3
Wave
Length
Optical Budget
(dBm)
Optical
Power (dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-2MLC-2 LC 2 Multimode
2km
(1.2mi)
1310nm 10 -9 ~ -1 -19
0 to + 50C
(32 to 122F)
OM3 Multimode fiber @ 2000/500MHz-km Optimized got 850nm VCSELs
Gigabit Ethernet 1000 Base LX
Part #
Fiber
Connector
# of
Fibers
Fiber Type
Max
Distance
Wave
Length
Optical Budget
(dBm)
Optical
Power (dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-2SLC-10 LC 2
Single
Mode
10km
(6.2mi)
1310nm 18 -9.5 ~ -3 -20
0 to + 50C
(32 to 122F)
S35-2SLC-10 LC 2
Single
Mode
10km
(6.2mi)
1310nm 18 -9.5 ~ -3 -20
-40 to +75C
(-40 to 167F)
S30-2SLC-30 LC 2
Single
Mode
30km
(18.6mi)
1310nm 18 -2 ~ +3 -23
0 to + 50C
(32 to 122F)
S35-2SLC-30 LC 2
Single
Mode
30km
(18.6mi)
1310nm 18 -2 ~ +3 -23
-40 to +75C
(-40 to 167F)
Page 13
IFS SFP Tranceivers User Manual 7
Gigabit Ethernet 1000 Base ZX
Part #
Fiber
Connector
# of
Fibers
Fiber Type
Max
Distance
Wave
Length
Optical Budget
(dBm)
Optical
Power (dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-2SLC-70 LC 2
Single
Mode
70km
(43mi)
1550nm 19* -15 ~ -8 -34
0 to + 50C
(32 to 122F)
S35-SLC-70 LC 2
Single
Mode
70km
(43mi)
1550nm 19* -15 ~ -8 -34
-40 to +75C
(-40 to 167F)
* Note: High Power Optic. There must be a minimum of 5dB of optical loss to the fiber for proper operation.
Gigabit Ethernet 1000 Base BX
Part #
Fiber
Connector
# of
Fibers
Fiber Type
Max
Distance
Wave Length
TX RX
Optical Budget
(dBm)
Optical Power
(dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-1SLC/A-10 LC 1
Single
Mode
10km
(6.2mi)
1310/1490nm 11 -9 ~ -3 -20
0 to + 50C
(32 to 122F)
S30-1SLC/B-10 LC 1
Single
Mode
10km
(6.2mi)
1490/1310nm 11 -9 ~ -3 -20
0 to + 50C
(32 to 122F)
S30-1SLC/A-20 LC 1
Single
Mode
20km
(12mi)
1310/1490nm 15 -8 ~ -2 -23
0 to + 50C
(32 to 122F)
S30-1SLC/B-20 LC 1
Single
Mode
20km
(12mi)
1490/1310nm 15 -8 ~ -2 -23
0 to + 50C
(32 to 122F)
Gigabit Ethernet 1000 Base BX
Part #
Fiber
Connector
# of
Fibers
Fiber
Type
Max
Distance
Wave Length
TX RX
Optical
Budget
(dBm)
Optical
Power (dBm)
Receiver
Sensitivitiy
(dBm)
Operating
Temperature
S30-1SLC/A-60 LC 1
Single Mode
60km (37mi)
1310/1490nm 24 0 ~ +5 -24
0 to + 50C (32 to 122F)
S30-1SLC/B-60 LC 1
Single Mode
60km (37mi)
1490/1310nm 24 0 ~ +5 -24
0 to + 50C (32 to 122F)
* Note: High Power Optic. There must be a minimum of 5dB of optical loss to the fiber for proper operation.
Page 14
8 IFS SFP Tranceivers User Manual
Appendix A
Fiber Optical Cable Connection Parameters
The wiring details are as below:
• Fiber Optical patch Cables:
Standard Fiber Type Cable Specification
1000Base-SX (850nm) Multi-mode 50/125ȝm or 62.5/125ȝm
1000Base-LX (1310nm) Single mode 9/125ȝm
1000Base-LX (1550nm) Single mode 9/125ȝm
Multi-mode 50/125ȝm or 62.5/125ȝm
100Base-FX (1310nm)
Single mode 9/125ȝm
Loading...