IFS
Line / Fiber Transmission
R3
IFS Rack Mount Card Cage
QUALITY DESIGN
The design approach employed by IFS for equipment mounted
within the model R3 Chassis Rack Unit with Integral 115/230
VAC Power Supply, provides for the elimination of a single-point
failure in the event of a major fault within any module located
within the chassis rack. This is accomplished through the use of
automatic electronic current limiting within each rack-mountable
module,rather than to provide the current limiting within the power
supply unit which supports the power requirements for equipment
located within the rack. In nearly all competing designs, a major
fault within a module, located within the chassis rack, results in
the power supply unit going into a current limiting condition, and
as a result, all of the modules located within the rack shut down.
The R3 Rack design employed by IFS eliminates this possibility,
as only the faulty module shuts down, and the operation of the
other devices within the rack continues unimpaired. This automatic
current limiting feature is also self-resetting, should the fault or
overload be of a temporary or intermittent condition. Furthermore,
all modules located within the chassis rack are hot-swappable, so
that it is not necessary to power-down the rack when removing or
replacing modules. Rather than utilizing a switching-mode or linear
DC power supply for providing the operating power to the rack as
employed by most competing designs, the IFS Model R3 Chassis
Rack uses a simple under stressed step-down power transformer,
and all rectification, filtering, and regulation is performed within each
rack mounted module. The use of a step-down power transformer
for the power supply unit results in a significantly higher MTBF than
any switching-mode or linear DC power supply can provide, as there
are no semiconductors, electrolytic capacitors, etc., to degrade the
reliability of the supply. In addition, the high-reliability transformer
power supply and current limiting built into each module, eliminates
the necessity of providing redundant power supplies within the
chassis rack, as the overall system reliability is still much higher (and
less costly) than can be provided with a redundant power supply
design approach.
interlogix.com
Specifications
Data
Data Interface: RS-232 (data lines only), or RS-422 (see note)
Data Rate: DC - 1.5 Mbps (NRZ)
Operating Mode: Asynchronous Simplex or Full-Duplex
Bit Error Rate: <1 in 10˚
Wavelength D1010: 850 nm, MM D1010WDMA: 850/1310 nm, MM
D1010WDMB: 1310/850 nm, MM D1020: 1310 nm, MM
D1030: 1310 nm, SM D1030WDMA: 1310 nm, SM
D1030WDMB: 1550 nm, SM
Number Of Fibers D1010: 2 D1010WDMA: 1 D1010WDMB: 1 D1020: 2
D1030: 2 D1030WDMA: 1 D1030WDMB: 1
Connectors
Optical: ST
Data and Power: Terminal Block with Screw Clamps
Electrical & Mechanical
Power:
Surface Mount: 12 VDC @ 150 mA
Rack: From Rack
Number of Rack Slots: 1
Current Protection: Automatic Resettable Solid-State Current Limiters
Circuit Board: Meets IPC Standard
Size (in./cm.) (LxWxH)
Surface Mount: 4.2 x 4.0 x 1.0 in., 10.7 x 8.9 x 2.5 cm
Rack Mount: 7.0 x 4.9 x 1.0 in., 17.8 x 12.5 x 2.5 cm
Shipping Weight: < 2 lbs./0.9 kg
Environmental
MTBF: > 100,000 hours
Operating Temp: -40° C to +74° C
Storage Temp: -40° C to +85° C
Relative Humidity: 0% to 95% (non-condensing)†
†May be extended to condensation conditions by adding suffix ‘–C’ to
model number for conformal coating.
GE
Security
North America
T 888-GE-SECURITY
888-437-3287
F 503-691-7566
E sales@ifs.com
Asia
T 852-2907-8108
F 852-2142-5063
Australia and New Zealand
T 613-9239-1200
F 613-9239-1299
Europe
T 44-113-238-1668
F 44-113-253-8121
Latin America
T 305-593-4301
F 305-593-4300
gesecurity.com/ifs
Specifications subject to
change without notice
© 2008 General Electric Company
All Rights Reserved
R3
IFS Rack Mount Card Cage
Ordering Information
Part Number Description
R3 19” Rack, 115 VAC Input (Includes power suppy)
R3-230 19” Rack, 230 VAC Input (Includes power supply)
R3-CH 19” Rack, No power supply
Options R3-BP Blank Panel (1”)
PS-R3-115-07 115VAC Power Supply
PS-R3-230
Specifications
-07
230VAC Power Supply
North America
T 855-286-8889
Latin America
T 561-998-6114
Input Voltage:
Power Supply (to plug-in modules): 20VAC C.T. @ 2.8A
# Slots/Spacing R3:
Fusing
AC Line Cord
Electrical & Mechanical
Circuit Board: Meets IPC Standard
Size (in./cm.) (LxWxH)
Surface Mount: 19.0 x 7.0 x 5.25 in., 48.3 x 17.8 x 13.3 cm
Shipping Weight: < 5 lbs./2.15 kg
Environmental
MTBF: > 100,000 hours
Operating Temp: -40° C to +74° C*
Storage Temp: -40° C to +85° C*
115VAC (other voltages available)
14 one-inch modules or 7 two-inch modules*
*Maximum number of modules based on total current draw of
each. Maximum current draw of 2.8A.( Example
14 modules X .200A = 2.8A)
1A slow blow (Rack power supply) (Plug-in modules individually
electronically fused
Detachable, IEC-connectorized.
Allows easy field replacement or exchange for various worldwide
AC power plug configurations
Agency Compliance
Complies with FDA Performance
Standard for Laser Products, Title 21,
Code of Federal Regulations, Subchapter J
interlogix.com
Specifications subject to change without notice.
© 2014 United Technologies Corporation
All rights reserved.
Interlogix is part of UTC Building & Industrial Systems,
a unit of United Technologies Corporation.
R3