Interlogix 3555 User Manual

SENTROL 3555 SERIES Bill Trap
Installation Instructions
The 3555 Series Bill Trap is a dry contact that draws no power and is wireless compatible. To install the unit, clean both the underside of the Bill Trap and the bottom of the cash register drawer or tray with alcohol. Adhere the Bill Trap to the appropriate surface with the adhesive tape provided. Run the switch leads out the back of the cash register drawer by drilling a 1/4" hole and attaching the leads to a service loop. Or, the leads may run over the top of the drawer, depending on the amount of clearance.
Warning: Do not overextend the lid by more than one inch. Doing so may cause the Bill Trap to malfunction.
Bill Trap With Bill Inserted
(Black) Common
10
10
(White) Closed when bill inserted
Special Instructions for Mounting the Bill Trap on Steel
The performance of the Bill Trap may be adversely affected if the unit is mounted on steel. For this reason, two additonal strips of double-sided tape have been included. If you experience difficulties when mounting your Bill Trap on steel, apply these two pieces of doubleĀ­sided tape onto the existing tape prior to mounting.
Form C
Voltage........30 V MAX
Current......0.25 A MAX
Power........3.0 W MAX
Cycles...........10,000,000
Wiring Diagram
(Black) Common
(Red) Open when bill inserted
THE UNITED STATES of
10
10
Ordering Information
PART NUMBER LOOP TYPE CONFIGURATION CHOICES TYPE
3555 Open or Closed SPDT Black #22 gauge 6" wire
ELECTRICAL COLOR LEAD
(White) Closed when bill inserted (Red) Open when bill inserted
PK-0738 Rev E 06/01