Interlogix 319.5 User Manual

319.5 Crystal MaxLife Door/Window Sensor Installation Instructions

Introduction

These are the 319.5 Crystal Maxlife Door/Window Sensor Installation Instructions for models 60-362N-10-319.5 and
60-362N-11-319.5. Install the sensor (Figure 1 windows, and other objects that open and close. The sensor transmits signals to the control panel when a magnet mounted near the sensor is moved away from or closer to the sensor. The sensor is equipped with a cover tamper microswitch for additional security.
Figure 1. Sensor
Use the following installation guidelines:
Mount the sensor on the door frame and the magnet on the door. For double doors, mount the sensor on the least­used door and the magnet on the most-used door.
Where possible, install sensors within 100 ft. (30 m) of the panel. While a transmitter may have an open-air range of 500 ft. (150 m) or more, the environment at the installation site may have a significant affect on operational range. Changing a sensor location may improve wireless communication.
Line up the alignment mark on the magnet to one of the alignment marks on the sensor.
Mount sensors at least 4.7 in. (12 cm) above the floor to avoid potential damage.
Avoid mounting sensors in areas where they will be exposed to moisture or where the operating temperature range will exceed the specified range.
If possible, mount directly to a stud. If a stud is not available, use plastic anchors.
Avoid mounting the sensor in areas with a large quantity of metal or electrical wiring.
Only one input can be used at any given time.
) on doors,
You must mount the magnet within 3/8 in. (0.95 cm) of the sensor.
Mount sensors with screws, not double-sided tape.
Only install the EOL resistor when an external contact is used.
You will need the following tools and materials:
Two #6 x 1.00 in. PPH (Phillips panhead) screws and two plastic anchors for mounting the sensor (included).
Two #6 x 0.625 in. PPH screws for mounting the magnet (included).
External contact 4.7 Kohm end-of-line (EOL) resistor (included).
• Phillips screwdriver
Caution: You must be free of all static electricity when
handling electronic components. Touch a grounded, bare metal surface before touching a circuit board or wear a grounded wrist strap.

Programming

This section describes general guidelines for programming (learning) the sensor into panel memory. Refer to the specific panel or receiver documentation for complete programming details.
To program the sensor:
1. Remove the sensor cover by squeezing the cover ends firmly releasing the tab (Figure 2
Figure 2. Sensor tab
2. If required, insert the battery into the battery holder, observing correct polarity (Figure 3
) from sensor base slot.
Tab
).
P/N 466-2298 • REV E • January 2011 1
Figure 3.
A
External
Contact Terminals
Battery
holder
Board components
Tamper switch
Positive
Reed B
Reed
Input
jumper
2. Take the sensor to the mounting location.
3. Hold the magnet next to the alignment mark on the sensor (Figure 5
Figure 5. Alignment marks
) and then pull the magnet away from the sensor.
Sensor end view
Sensor side view
3. Set the panel to program mode.
4. Proceed to the Learn sensors menu.
5. Set the external contact in the alarm condition (see
External contact wiring
6. Press and release the tamper switch (Figure 3
).
) on the
sensor until the panel responds.
7. Select the appropriate sensor group and number.
8. Exit program mode.

Input selection

Only one door/window input can be used at any given time. For example, if the external contact is used, internal reed switches (Reed A and Reed B in Figure 3
Note: Power down the device before positioning the input selection.
See Figure 4
and position the input selection jumper to select: Reed B. Left two pins covered (default). Reed A. Right two pins covered. External contact. Jumper removed.
) cannot be used.
Alignment marks
Magnet
4. Listen for siren beeps to determine appropriate response (refer to the specific panel/receiver documentation).
5. Exit sensor test mode.

Mounting

To mount the sensor:

1. Remove the sensor battery.
2. Remove the circuit board from the sensor base by pulling back on the plastic tab.
3. Mount the sensor base using the screws provided (Figure
6).
Figure 6. Mounting holes
Mounting
hole
Wire
entry
Figure 4 Input selection jumper
Mounting
Jumper
location
hole
4. Replace the circuit board.
5. Remove the magnet from its base.
6. Line up the magnet alignment mark with the sensor alignment mark, depending on the internal reed switch
Reed B
(default)
Reed A
External contact
being used (Figure 5
7. Mount the magnet base with the #6 x 0.625 in. PPH
).
screws no more than 3/8 in. (0.95 cm) away from the sensor base (Figure 7
). Replace the magnet cover.

Verifying RF communication

Before mounting the sensor, verify the sensor mounting location provides good RF panel communication.

To verify:

Put the panel/receiver into sensor test mode.
1.
2 319.5 Crystal MaxLife Door/Window Sensor Installation Instructions
Loading...
+ 2 hidden pages