Interlogix 2-Button Crystal Keychain Touchpad User Manual

2-Button Keychain Touchpad
Document Number: 46-897 Rev. A January 1995
60-607
INSTALLATION INSTRUCTIONS

About This Document

This document describes how to install and operate the 2-Button Keychain Touchpad.

Product Summary

The Keychain Touchpad is an alkaline battery-pow­ered, wireless touchpad designed to fit on a keychain, in a pocket or purse. It provides users a convenient option for the following system operations:
ν Arming the system ν Arming the system with no delay ν Disarming the system ν Police Panic alarm

Installation Guidelines

2-Button Keychain Touchpad
ν Keychain Touchpads are learned into the Panel as
sensors or wireless touchpads.
ν Each learned Keychain Touchpad uses one of the
available sensor numbers or one of the four wire­less touchpad numbers.
For example, if a CareTaker Plus system (32 zones) has six Keychain Touchpads learned as sensors, 26 available sensor numbers remain.
ν Keychain Touchpads learned as sensors are pro-
grammed into unsupervised groups (since they don’t send supervisory signals) that determine how the Panel responds when both Keychain Touchpad buttons are pressed together.
ν When learned as sensors, Keychain Touchpads
can be bypassed or deleted. This helps prevent lost or stolen Keychain Touchpads from operating the system.
ν Keychain Touchpads learned as sensors use the
sensor number as the user number for central sta­tion reports that include a user number.
ν All Keychain Touchpads learned as touchpads in
CareTaker Plus and Security Pro 4000 systems report to the central station as user number 41. For Commander 2000 and Security Pro 2000 sys­tems, Keychain Touchpads report as user number
20. These touchpads cannot be bypassed, but they can be deleted.

Tools Needed

ν Phillips screwdriver (for removing and replacing
the Panel cover or battery door)

Learning Keychain Touchpad s into Panel Memory

Use the following guidelines when adding Keychain Touchpads to the system:
ν CareTaker
must have software version 3.0 (or later) installed for Keychain Touchpad operation.
ν Commander
must have software version 4.0 (or later) installed for Keychain Touchpad operation.
®
Plus and Security Pro 4000 Panels
®
2000 and Security Pro 2000 Panels
This section describes how to learn Keychain Touch­pads into Panel memory for CareTaker Plus, Security Pro 4000, Commander 2000, and Security Pro 2000 Panels.
CareTaker
To learn Keychain Touchpads as sensors:
1) Disarm the system to level 1.
Plus
and Security Pro 4000
Page 1
2-Button Keychain Touchpad
2) Place the Panel in the program mode by r emoving the Panel cover.
3) Using an alphanumeric touchpad, enter the learn sensors mode, then press COMMAND.
4) Select the appropriate unsupervised group num­ber (01, 03, 06, 07, 32) and press COMMAND.
5) Select the desired sensor number (1 through 32 for CareTaker Plus, 1 through 40 for Security Pro
4000) you want assigned to the Keychain Touch­pad and press COMMAND.
6) Trip the Keychain Touchpad by pressing and holding the arm and disarm buttons together, until the LED flashes. The Panel announces “Sen­sor nn okay.”
7) Repeat steps 5 and 6 until all Keychain Touchpads are learned.
8) Replace the Panel cover.
To learn Keychai n Touchpads as W ir eless Touchpads:
Note: If the system includes other wireless touchpads,
they must be programmed at this time, even if they already exist in Panel memory. If existing touchpads are not reprogrammed, they are deleted from memory when pressing COMMAND after entering the
learn touchp ads mode.
6) Trip the Keychain Touchpad by pressing and holding the arm and disarm buttons together, until the LED flashes. The Panel announces “Sen­sor nn okay.”
7) Repeat steps 4, 5, and 6 until all Keychain Touch­pads are learned.
8) Replace the battery door.
To learn Keychain Touchpads as Wireless Touchpads:
1) Disarm the system to level 1.
2) Remove the battery door.
3) Enter either the installer or dealer programming code.
4) Press STATUS + STATUS + n (n = touchpad ID number 1, 2, 3, or 4).
5) Trip the Keychain Touchpad by pressing and holding the arm and disarm buttons together, until you see the LED flash. The Panel announces “N okay.”
6) Repeat step 5 until all Keychain Touchpads are learned.
7) Replace the battery door.

Testing Keychain Touchpad Operation

1) Disarm the system to level 1.
2) Place the Panel in the program mode by r emoving the Panel cover.
3) Using an alphanumeric touchpad, enter the learn touchpads mode and press COMMAND. The alphanumeric display reads PRESS TP 01 BYP.
4) Press the Keychain Touchpad arm and disarm buttons together, until the LED flashes. The Panel announces “N okay.”
5) Repeat step 4 until all Keychain Touchpads and wireless touchpads are learned.
6) Replace the Panel cover.

Commander 2000 and Security Pro 2000

To learn Keychain Touchpads as sensors:
1) Disarm the system to level 1.
2) Remove the battery door.
3) Enter either the installer or dealer programming code.
4) Select the appropriate unsupervised group num­ber by pressing STATUS + nn (nn = 01, 03, 06, 07). The Panel announces “Sensor level nn.”
5) Enter the desired sensor number (01 through 17).
Test Keychain Touchpad operation by pressing the buttons as described below:
1) Disarm Button - The Panel disarms to level 1.
2) Arm Button - With optional feature number F25 off:
ν the Panel attempts arming from level 1 to level 2 ν the Panel attempts arming from level 2 to level 3 ν if protesting, the Panel responds as if BYPASS was
pressed
With optional feature number F25 on:
ν the Panel arms directly to level 3, with no delay ν if protesting, the Panel responds as if BYPASS was
pressed
3) Arm and Disarm Buttons Together - The Panel responds with an alarm condition as follows:
ν Keychain Touchpads learned as sensors generate
an alarm based on the sensor group in which they are learned
ν Keychain Touchpads learned as wireless touch-
pads generate a police panic alarm (upper sensor number 81)
Page 2