Interlogix 2315 User Manual

2315 Series
Panel Door Magnetic Contact
Models: 2315A, 2317A
Installation Instructions
Mounting
Caution: Locate the magnet away from manual
handles and latches to prevent it from being used as a foothold or handle to close the door.
Figure 1
Optional: Use the existing roller-track bolts to mount the switch without using the L-Bracket as shown in Figure 3.
Figure 3
3. Connect the switch wires to the alarm system and test to verify proper operation.
Important: The contact should be mounted at least 13 inches from the floor. If other track­mounted devices interfere, mount the switch under them.
2. Align the magnet with the switch and use screws to attach it to the door as shown in Figure 2. The switch and magnet must be aligned within 1/2 inch of each other to prevent false alarms.
Figure 2
elevation 1
1/4 to 1/2” spacing
elevation 2
The magnet can be attached at two different elevations from the door.
Fits standard 2” roller-tracks for sectional/panel overhead doors.
Figure 4
Dimensions Specifications
x
General
The contact shall be a hermetically sealed reed switch nomi­nally 3.07” H x 1.80” W x 2.60” D with actuating magnet.
Fits 1.5” (3.8cm)
to 2.4” (6.1cm)
2.6”
6.6cm
Contact and magnet shall be in extruded aluminum type housing. Contact shall be sealed in GE Interlogix exclusive polyurethane potting compound. Mounting bracket shall be furnished with contact. Contacts shall be specified as GE Interlogix part numbers 2315A and 2317A. Contact is de­signed for installation on metal overhead door tracks.
USA Specifications
Form A (2315A) Voltage 100V AC/DC max. Current 0.5 A max. Power 7.5 W max.
3.07”
7.8cm
2.0”
5.1cm
2.16”
5.5cm
3.1”
7.9cm
1.8”
4.6cm
0.85”
2.2cm
1.7”
4.3cm
1.88”
4.8cm
3.51”
8.9cm
2.51”
6.4cm
Form C (2317A) Voltage 30V AC/DC max. Current 0.25 A max. Power 3.0 W max.
Canadian Specifications
Form A (2315A), Form C (2317A) Voltage 30VDC max. Current 50mA max.
European Union Specifications
Form A (2315A) Voltage 48V AC/DC max. Current 0.5A max.
WARNING: Each electrical rating is an
individual maximum and cannot be exceeded!
Lead Functions
Form C (2317A)
Lead Color Function
Black Common White Closed Loop (N.O.)
Re d Open Loop (N.C.)
Ordering Information
Model Loop Typ e Electrical Gap Distance Lead T ype Listing
Number Configuration (Make)*
2315A-L Closed NO Up to 3” 2’ stainless steel armored cable C UL-US 2317A-L Open or closed SPDT Up to 3” 2’ stainless steel armored cable C UL-US
*Gap distances are nominal make distance ±20%. Gap specifications are for switch to make. Break distance is approximately 1.1 to 1.5 times make.
GE Interlogi
www.GE-InterlogixSecurity.com
1030554 Rev B 09/03