Magnapull Heavy Duty Magnetic Contact with Pull-Ap art Cords
Models: 2105-A, 2107-A
Installation Instructions
Mounting
Mount the magnet section on the object to be protected. Once the magnet is installed, place the cover over the magnet and screw it to the surface. Use #10 screws to secure both units. Mount the cord section with clamps so the cord will pull straight out of the magnet housing when it reaches the end of the cord. Make sure it has the correct slack and loop so it will not hang up on anything as the protected object is moved.
Alternate mounting
Loop the cord through the object being protected or through a stationary object.
CAUTION If the alternate mounting is used, make sure
the alarm owner is warned that they could break the pull-apart if they do not release it before moving the protected object.
Lead functions
Form A Model 2105-A, use black leads Form C Model 2107-A
Lead color Function
Black Common White Closed Loop (NO) Re d Open Loop (NC)
Magnet cover
3.44"
8.73 cm
2.50"
5.75 cm
Magnet
2.13"
5.40 cm
Switch
2.56"
6.50 cm
0.56"
1.43 cm
1.25"
3.19 cm
0.44"
1.11 cm
0.69"
1.75 cm
1.63"
4.13 cm
0.75"
1.91 cm
T o alarm control
T o alarm control
Movable portion of unit to be protected
Stationary post
Movable portion of unit to be protected
Ring or eye bolt on wall
Ordering information
Part Loop Type Electrical Color Choices Lead T ype
Number Configuration
2105-A Closed NO Off-white, gray, or mohogany brown 3' stainless steel armored cable 2107-A Open or Closed SPDT Gray 3' stainless steel armored cable
European Union Specification: 48 V AC/DC max., 0.5 A
Form A: 2105-A
Voltage: 100 V AC/DC max. Current: 0.5 A max. Power: 7.5 W max.
Form C: 2107-A
Voltage: 100 V AC/DC max. Current: 0.3 A max. Power: 3.0 W max.