Interlogix 1072 User Manual

1072 Series
Magnetic Contacts
Gap distance Closed loop
Regular Up to 1/2" 1072
Color
Quantity
Natural
10
U
¤
L
C
LISTED
1072-N
US
1072 Series 3/8" Diameter Flanged with Wire Leads Magnetic Contacts
Installation Instructions
General
Drill 3/8" diameter hole, press in, secure with screws through flange holes.
Magnet (1057)
Slightly overdrill 3/8" diameter hole. Coat magnet with RTV Mounting Compound (Sentrol part number 1905), press into hole.
1072 Series
1.31"
3.31 cm
0.56"
1.42 cm
0.75"
1.91cm
®
1.31"
3.31 cm
Magnet
Part No. 1925
(included)
0.38"
0.95 cm
Mounting Positions
CORRECT
End-to-End
Perpendicular
Parallel
UL Specifications
Part Loop Electrical Gap Distance
Number Type Configuration Make* (Up to)
1072 Closed N.O. 1/2"
INCORRECT
Do NOT center
magnet under switch
FORM A (1072) Voltage: 100 VAC/DC Max Current: 0.5 A Max Power: 7.5 W Max
* Gap Specifications are nominal and may vary ± 20%. Gap Specifications are for switch to make. Break distance is
approximately 1.1 to 1.5 times make.
PK-0983 Rev E 10/01
Loading...