Intel SRCU42E - Ultra320 SCSI PCI Express X8 RAID Storage Controller, SRCU42E Hardware User's Manual

Page 1
Hardware
User’s Guide
Intel® RAID Controller SRCU42E
June 2004
C76895-002
Page 2
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel is a trademark or registered trade mark of Intel Cor poration or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others. Copyright © 2004 by Intel Corporation. Portions Copyright 2003 - 2004 by LSI Logic Corporation. All
rights reserved.
2
Page 3
Safety Warnings
WARNING: English
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards\server\safecert.htm.
SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps:
1. Tur n off all peripheral devices connected to the system.
2. Tur n off the system by pressing the power button.
3. Unplug all AC power cords from the system or from wall outlets.
4. Label and disconnect all cables connected to I/O connectors or ports on the back of the system.
5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components.
6. Do not operate the system with the chassis covers removed. A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges
on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves.
ADVERTENCIAS: Español
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y/o en http:\\support.intel.com\support\motherboards\server\safecert.htm.I
NSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las siguientes instrucciones:
1. Apague todos los dispositivos periféricos conectados al sistema.
2. Apague el sistema presionando el interruptor encendido/apagado.
3. Desconecte todos los cables de alimentación CA del sistema o de las tomas de corriente alterna.
4. Identifique y desconecte todos los cables enchufados a los conectores E/S o a los puertos situados en la parte posterior del sistema.
5. Cuando manipule los componentes, es importante protegerse contra la descarga electrostática (ESD). Puede hacerlo si utiliza una muñequera antiestática sujetada a la toma de tierra del chasis - o a cualquier tipo de superficie de metal sin pintar.
6. No ponga en marcha el sistema si se han extraído las tapas del chasis. Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes.
También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores.
3
Page 4
WARNUNG: Deutsch
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder un ter http:\\support.intel.com\support\motherboards\server\safecert.htm.
SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten:
1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus.
2. Schalten Sie das System mit dem Hauptschalter aus.
3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose.
4. Auf der Rückseite des Systems beschriften und ziehen Sie alle Anschlußkabel von den I/O Anschlüssen oder Ports ab.
5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden.
6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Der Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können
einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen.
Der Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen.
AVERTISSEMENT: Français
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com\support\motherboards\server\safecert.htm.
CONSIGNES DE SÉCURITÉ: Lorsque vous ouvrez le boîtier pour accéder à l’intérieur du système, suivez les consignes suivantes:
1. Mettez hors tension tous les périphériques connectés au système.
2. Mettez le système hors tension en mettant l’interrupteur général en position OFF (bouton-poussoir).
3. Débranchez tous les cordons d’alimentation c.a. du système et des prises murales.
4. Identifiez et débranchez tous les câbles reliés aux connecteurs d’E-S ou aux accès derrière le système.
5. Pour prévenir les décharges électrostatiques lorsque vous touchez aux composants, portez une bande antistatique pour poignet et reliez-la à la masse du système (toute surface métallique non peinte du boîtier).
6. Ne faites pas fonctionner le système tandis que le boîtier est ouvert. Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites
également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l’usage de gants de protection.
Intel RAID Controller SRCU42E 4
Page 5
AVVERTENZA: Italiano
PASSI DI SICUREZZA: Qualora si rimuovano le coperture del telaio per accedere all’interno del sistema, seguire i
seguenti passi:
1. Spegnere tutti i dispositivi periferici collegati al sistema.
2. Spegnere il sistema, usando il pulsante spento/acceso dell’interruttore del sistema.
3. Togliere tutte le spine dei cavi del sistema dalle prese elettriche.
4. Identificare e sconnettere tutti i cavi attaccati ai collegamenti I/O od alle prese installate sul retro d el sistema.
5. Qualora si tocchino i componenti, proteggersi dallo scarico elettrostatico (SES), portando un cinghia anti-statica da polso che è attaccata alla presa a terra del telaio del sistema - qualsiasi superficie non dipinta - .
6. Non far operare il sistema quando il telaio è senza le coperture. Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati.
Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l’uso di guanti di protezione.
Regulatory and Certification Information
Product Regulatory Compliance
This RAID Controller Card complies with the following safety and electromagnetic compatibility (EMC) regulations.
Product Safety Compliance
UL 1950 - CSA 950 (US/Canada)
EN 60 950 (European Union)
IEC60 950 (International)
CE - Low Voltage Directive (73/23/EEC) (European Union)
Product EMC Compliance - Class B
FCC /ICES-003 (USA/Canada)
CISPR 22 (International)
EN55022 (Europe)
EN55024 (Europe)
CE - EMC Directive 89/336/EEC (Europe)
VCCI (Japan)
AS/NZS 3548 (Australia / New Zealand)
BSMI CNS13438 (Taiwan)
RRL, MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea)
Product Regulatory Compliance Markings
The RAID Controller Card is marked with the following compliance markings. Some marking information may be provided on the packaging and/or in the product documentation due to limited markin g space on the product.
ETL NRTL Mark (US/Canada)
FCC Mark (US)
ICES-003 (Canada)
CE Mark (Europe)
VCCI Mark (Japan)
MIC Mark (Korea)
BSMI DOC Mark (Taiwan)
ACS C-Tick Mark (Australia)
5
Page 6
Regulatory Compliance Country Marking
cULus Listing Marks USA/Canada
ETL (NRTL) Mark USA/Canada
CE Mark Europe
FCC Marking (Class A) USA This device complies with Part 15 of the FCC Rules. Operation
of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Marking (Class B) USA
EMC Marking (Class A) Canada CANADA ICES-003 CLASS A
CANADA NMB-003 CLASSE A
EMC Marking (Class B) Canada CANADA ICES-003 CLASS B
CANADA NMB-003 CLASSE B
VCCI Marking (Class A) Japan
VCCI Marking (Class B) Japan
BSMI Marking (Class A or B) and
Taiwan
Class A EMC Warning
RRL MIC Mark Korea
C-Tick Mark Australia
6
Page 7
Electromagnetic Compatibility Notices
FCC Verification Statement (USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including inte rference that may cause undesired operation.
Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 Phone: 1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular insta llation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Intel is not responsible for any radio or television interference caused by unauthorized modification of this equipment for substitution or attachment of connecting cables and equipment other than those specified by Intel. The correction of interferences casued by such unauhtorized modification, substitution, or attachement will be the responsibility of t he user.
This RAID Controller Card has been tested to comply with FCC Standards for home or office use.
ICES-003 (Canada)
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the C anadian Department of Communications.
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe Aprescrites dans la norme sur le matériel brouilleur: “Appareils Numér iques”, NMB-003 édictée par le Ministre Canadien des Communictations.
Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.
RRL (Korea)
English translation of the notice above:
1. Type of Equip ment (Model Name): Model name on product
2. Certification No.: On RRL certificate. Obtain cer tificate from local Intel representative
3. Name of Certification Recipient: LSI Logic Cor poration
4. Date of Manufacturer: Refer to date code on product
5. Manufacturer/Nation: LSI Logic Corporation / Refer to country of origin marked on product
7
Page 8
Audience
Preface
This guide is the hardware reference and user’s guide for the Intel® RAID Controller SRCU42E. It contains complete installation instructions and specifications .
For information about how to configure the RAID Controller SRCU42E, and for an overview of the software drivers, see the Intel RAID Software User’s Guide.
This document assumes that you have some familiarity with RAID controllers and related support devices. The people who benefit from this book are:
Engineers who are designing an RAID Controller SRCU42E into a system
Anyone installing an RAID Controller SRCU42E in their RAID system
Organization
This document has the following chapters and appendixes:
Chapter 1, “Overview,” provides a general overview of the RAID Controller SRCU42E.
Chapter 2, “Hardware Installation,” describes the procedures for installing the RAID
Chapter 3, “Intel
Chapter A, “Glossary of Terms and Abbreviations,” lists and explains the terms and
Related Publications
Intel® RAID Software User’s Guide on the Resource CD included with the RAID controller.
Controller SRCU42E.
®
RAID Controller SRCU42E Technical Reference,” describes the
technical specifications for the RAID Controller SRCU42E.
abbreviations used in this manual.
8
Page 9
Safety Instructions
Use the following safety guidelines to help protect your computer system from potential damage and to ensure your own personal safety.
When Using Your Computer System
As you use your computer system, observe the following safety guidelines:
CAUTION:
Do not operate your computer system with any cover(s) (such as computer covers, bezels, filler brackets, and front-panel inserts) removed:
To help avoid damaging your computer, be sure the voltage selection switch on the power supply is set to match the alternating current (AC) power available at your location:
115 volts (V)/60 hertz (Hz) in most of North and South America and some Far
Eastern countries such as Japan, South Korea, and Taiwan
230 V/50 Hz in most of Europe, the Middle East, and the Far East. Also be sure your
monitor and attached peripherals are electrically rated to operate with the AC power available in your location.
To help avoid possible damage to the system board, wait five seconds after turning off the system before removing a component from the system board or disconnecting a peripheral device from the computer.
To help prevent electric shock, plug the computer and peripheral power cables into properly grounded power sources. These cables are equipped with 3-prong plugs to ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. If you must use an extension cable, use a 3-wire cable with properly grounded plugs.
To help protect your computer system from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply.
Be sure nothing rests on your computer system’s cables and that the cables are not located where they can be stepped on or tripped over.
Do not spill food or liquids on your computer. If the computer gets wet, consult the documentation that came with it.
Do not push any objects into the openings of your computer. Doing so can cause fire or electric shock by shorting out interior components.
Keep your computer away from radiators and heat sources. Also, do not block cooling vents. Avoid placing loose papers underneath your computer; do not place your computer in a closed-in wall unit or on a rug.
9
Page 10
When Working Inside Your Computer
Notice: Do not attempt to service the computer system yourself, except as explained in
this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely.
1. Turn off your computer and any peripherals.
2. Disconnect your computer and peripherals from their power sources. Also disconnect an y telephone or telecommunications lines from the computer.
Doing so reduces the potential for personal injury or shock.
Also note these safety guidelines:
When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the cable itself. Some cables have a connector with locking tabs; if you are disconnecting this type of cable, press in on the locking tabs before disconnect the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, make sure both connectors are correctly oriented and aligned.
Handle components and cards with care. Don’t touch the components or contacts on a card. Hold a card by its edges or by its metal mounting bracket. Hold a component such as a microprocessor chip by its edges, not by its pins.
Protecting Against Electrostatic Discharge
Static electricity can harm delicate components inside your computer. To prevent static damage, discharge static electricity from your body before you touch any of your computer’s electronic components, such as the microprocessor. You can do so by touching an unpainted metal surface, such as the metal around the card-slot openings at the back of the computer.
As you continue to work inside the computer, periodically touch an unpainted metal surface to remove any static charge your body may have accumulated. In addition to the preceding precautions, you can also take the following steps to prevent damage from electrostatic discharge (ESD):
When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing material until you are ready to install the component in your computer. Just before unwrapping the antistatic packaging, be sure to discharge static electricity from your body.
When transporting a sensitive component, first place it in an antistatic container or packaging.
Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads.
10
Page 11
Chapter 1 Overview
Contents
1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.3 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.3.1 RAID Controller Configurations . . . . . . . . . . . . . . . . . 17
1.3.2 Configuration on Disk . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.3.3 Drive Roaming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Chapter 2 Hardware Installation
2.1 Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.2 Quick Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.3 Detailed Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.4 After You Have Installed the RAID Controller. . . . . . . . . . . . . 25
Chapter 3
®
Intel
RAID Controller SRCU42E Technical Reference
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.2 Intel
3.3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.3.1 RAID Controller Specifications . . . . . . . . . . . . . . . . . 28
3.3.2 Array Performance Features . . . . . . . . . . . . . . . . . . . . 29
3.3.3 Fault Tolerance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.3.4 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . 30
3.3.5 Thermal and Atmospheric Characteristics . . . . . . . . . 30
3.3.6 Safety Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . 31
®
RAID Controller SRCU42E Characteristics . . . . . . . . . . 28
Chapter A Glossary of Terms and Abbreviations
11
Page 12
Figures
2.1 Install the Intel Portable Cache Module . . . . . . . . . . . . . . . . . . 21
2.2 Inserting the Intel
®
RAID Controller SRCU42E in a x8 PCI Express* Slot22
2.3 Terminating an Internal SCSI Disk Array. . . . . . . . . . . . . . . . . 24
3.1 Intel
®
RAID Controller SRCU42E Layout. . . . . . . . . . . . . . . . 26
12
Page 13
Tables
1-1 Intel® Raid Controller SRCU42E Features . . . . . . . . . . . . . . . 17
2-1 Target ID’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3-1 Intel 3-2 Intel 3-3 Intel
®
RAID Controller SRCU42E Headers and Connectors . 27
®
RAID Controller SRCU42E Characteristics . . . . . . . . . 28
®
RAID Controller SRCU42E Specifications . . . . . . . . . . 28
3-4 Array Performance Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3-5 Fault Tolerance Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3-6 Maximum Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . 30
13
Page 14
14 Contents
Page 15
Chapter 1 Overview
This section provides a general overview of the Intel® RAID Controller SRCU42E . It consists of the following sections.
Section 1.1, “Overview,” page 15
Section 1.2, “Features,” page 16
Section 1.3, “Hardware,” page 17
1.1 Overview
The Intel® RAID Controller SRCU42E is a high-performance intelligent PCI Express* host adapter with Redundant Array of Independent Disks (RAID) control capabilities. The RAID Controller SRCU42E provides reliability , high performance, and fa ult-tolerant disk subsystem management. It is an ideal RAID solution for the internal storage of workgroup, departmental, and enterprise systems. The RAID controller offers a cost-effective way to implement RAID in a server.
The RAID Controller SRCU42E (dual-channel) is a PCI Express* controller that has one LSI* 53C1030 controller chip that controls two SCSI channels. The RAID controller has two VHDCI 68-pin external SCSI connectors and two HDCI 68-pin internal SCSI connectors.
The RAID Controller SRCU42E supports a low voltage differential (LVD) or a single-ended (SE) SCSI bus. With LVD, you can use cables up to 12 meters long. Throughput on each SCSI channel can be as high as 320 Mbytes/s.
®
You can install the Intel a standard bracket type. With this RAID controller in your PCI-Express system, you can connect SCSI devices over a SCSI bus.
For Ultra320 SCSI performance, you must connect only LVD devices to the bus. Do not mix SE with LVD devices, or the bus speed will be limited to the slower SE (Ultra SCSI) SCSI data transfer rates. Do not connect a high voltage differential (HVD) device.
®
The Intel Windows* XP, Microsoft* Windows* 2000, Microsoft* Windows Server* 2003, Novell* NetWare*, Red Hat* Linux*, and SuSE* Linux*.
RAID Controller SRCU42E supports major operating systems, such as Microsoft*
Note:
The operating systems supported by this controller may not be supported by
your server board. Please refer to the tested OS list for your server board at
http://support.intel.com/support/motherboards/server/. See also the tested
hardware and operating system list for the RAID Controller SRCU42E to make
sure the RAID controller supports your operating system.
RAID Controller SRCU42E in PCI-Express computer systems with
Intel RAID Controller SRCU42E 15
Page 16
1.2 Features
Features of the Intel® RAID Controller SRCU42E include:
Support for hard disk drives with capacities greater than 8 Gbytes
Online RAID level migration
RAID remapping
No reboot necessary after expansion (for NT 4.0: if virtual sizing is enabled)
More than 200 Qtags per array
Hardware clustering support on the board
User-specified rebuild rate
Wide Ultra320 LVD SCSI performance up to 320 Mbytes/s
Support for up to 512 Mbyte of double data rate (DDR1) ECC PC2700 DDR333 DIMM:
Support for a x8 PCI Express interface.
The RAID Controller SRCU42E has two internal and two external SCSI connectors
Support for RAID levels 0 (striping), 1 (mirroring), 5 (striping and parity data across all
Advanced array configuration and management utilities
Battery backup for up to 72 hours with the 128 Mbyte Intel
Support for up to 14 SCSI drives per channel on storage system with SAF-TE enclosures
32 Kbyte NVRAM for storing RAID system configuration information; the firmware is
one 128-, 256-, or 512-Mbyte DIMM can be installed.
drives), 10 (mirroring and striping), and 50 (RAID 5 and striping)
®
Portable Cache Module
(SCSI accessed fault-tolerant enclosures): 15 SCSI drives per channel for other configurations.
stored in flash ROM for easy upgrade
Features 16
Page 17
1.3 Hardware
You can install the Intel® RAID Controller SRCU42E in a computer with a system board that has a x8 or x16 PCI Express slot.
The following subsections describe the hardware configuration and configuration-on-disk.
1.3.1 RAID Controller Configurations
Table 1-1 describes the features of the RAID Controller SRCU42E.
Table 1-1 Intel® Raid Controller SRCU42E Features
Feature Description
RAID Levels 0, 1, 5, 10, 50 SCSI Device Types Synchronous or Asynchronous Devices per SCSI Channel Up to 15 Wide SCSI devices SCSI Channels 2 SCSI Data Transfer Rate U p to 320 Mbytes/s per channel SCSI Bus LV D or S E Cache Function
Multiple Logical Drives/Arrays per Controller
Online Capacity Expansion Yes Dedicated and Pool Hot Spare Hot Swap Devices Supported Non-Disk Devices Supported Mixed Capacity Hard Disk
Drives Number of 16-bit Internal
Connectors Number of 16-bit External
Connectors Cluster Support Hardware Exclusive OR (XOR)
Assistance
Write-back (requires Portable Cache Module), Write-thro ugh, Adaptive Read Ahead, Non Read Ahead, Read Ahead, Cache I/O, Direct I/O
Up to 40 logical drives per controller
Yes Yes Yes Yes
2
2
Yes Yes
Direct I/O Ye s Architecture Fusion-MPT™
Hardware 17
Page 18
1.3.2 Configuration on Disk
Configuration on Disk saves configuration information both in NVRAM on the Intel® RAID Controller SRCU42E and on the disk drives attached to the RAID Controller SRCU42 E. If the RAID Controller SRCU42E is replaced, the new RAID Controller SRCU42E detects the actual RAID configuration from the configuration information on the drives. This maintains the integrity of the data on each drive, even if the drives have changed their target ID.
Note:
1.3.3 Drive Roaming
The RAID Controller SRCU42E supports drive roaming across channels on the same RAID Controller SRCU42E. Drive roaming lets an Intel Raid RAID Controller SRCU42E detect the actual RAID configuration, maintaining the integrity of the data on each disk drive, even if the disk drives have changed channels and/or target ID.
Note:
Configuration on Disk does not work if you change both the RAID Controller
SRCU42E and the SCSI connectors to different connectors on the new RAID
controller. It works only if you make one change at a time.
The RAID Controller SRCU42E does not support drive roaming across
channels when cluster mode is enabled.
Hardware 18
Page 19
Chapter 2 Hardware Installation
This chapter describes the procedures for installing the Intel® RAID Controller SRCU42E. It contains the following sections:
Section 2.1, “Requirements,” page 19
Section 2.2, “Quick Installation,” page 20
Section 2.3, “Detailed Installation,” page 20
Section 2.4, “After You Have Installed the RAID Controller,” page 25
2.1 Requirements
The following items are required to install the RAID controller:
An Intel
A host computer with an available x8 PCI Express* expansion slot
The Resource CD
The necessary internal and/or external SCSI cables. Ensure that the SCSI cables conform
to all SCSI specifications.
Ultra, Ultra2, Ultra160, or Ultra320 SCSI hard disk drives (although backward
compatible, SCSI uses the speed of the slowest device on the bus)
The Intel® Portable Cache Module (optional) or one 128-, 256-, or 512-Mbyte 200 MHz
DDR1 ECC PC2700 DDR333 memory DIMM (your RAID Controller SRCU42E may come with a 128 Mbyte DIMM pre-installed)
®
RAID Controller SRCU42E
Intel strongly recommends using an uninterruptible power supply (UPS).
Intel RAID Controller SRCU42E 19
Page 20
2.2 Quick Installation
The following steps are for for experienced computer users/installers. Section 2.3, “Detailed Installation”, contains detailed steps.
1) Attach the Intel® Portable Cache Module (Optional, required to enable Write Back
Cache) or attach the memory DIMM to the RAID controller if the DIMM is not pre­installed.
2) Turn power off to the server and all hard disk drives, enclosures, and system components
and remove the PC power cord.
3) Follow the instructions in the host system documentation to open the cabinet of the host
system.
4) Determine the SCSI ID and SCSI termination requirements.
5) Install the RAID Controller SRCU42E in the server, connect SCSI devices to it, and set
termination correctly on the SCSI channel(s).
6) Perform a safety check:
Ensure that all cables are properly attached. – Ensure that the RAID Controller SRCU42E is properly installed. – Close the cabinet of the host system.
7) Turn power on after completing the safety check.
2.3 Detailed Installation
This section provides detailed instructions for installing the Intel® RAID Controller SRCU42E.
1) Unpack
Unpack and remove the RAID Controller SRCU42E. Inspect it for damage. If it appears damaged, or if any items listed below are missing, contact your Intel support
representative. The Intel
The Resource CD, which contains Intel RAID drivers for supported operating
systems, an electronic version of this guide, and other related documentation.
A license agre ement
2) Attach the Intel® Portable Cache Module (Optional, required to enable Write Back
Cache) or attach the memory DIMM to the controller if the DIMM is not pre-installed. a. Remove the Intel® Portable Cache Module or memory DIMM from its packaging. b. Open both DIMM socket levers on the RAID controller, noted by letter B in the
figure below.
®
RAID Controller SRCU42E is shipped with:
c. Note the location of the alighment notch and insert the Intel® Portable Cache Module
or memory DIMM, lining up the slot in the Intel® Portable Cache Module or DIMM with the alignment notch.
d. Push the Intel® Portable Cache Module or DIMM firmly into the card. See letter A
in Figure 2.1.
e. Make sure the s ocket levers latch securely.
Quick Installation 20
Page 21
f. Intel® Portable Cache Module only: Insert the screw included with the Intel®
Portable Cache Module from the back of the Intel
®
RAID Controller SRCU42E into
the bracket on the Intel® Portable Cache Module.
Figure 2.1 Install the Intel Portable Cache Module
B
A
B
TP00749
3) Power Down the System
Turn off the computer and remove the AC power cord. Remove the system’s cover. See your system documentation for instructions.
4) Check the Jumpers
Ensure that the jumper settings on the your RAID Controller SRCU42E are correct. See
®
Chapter 3, “Intel
RAID Controller SRCU42E Technical Reference,” for diagrams of the
RAID Controller SRCU42Es with their jumpers and connectors.
5) Install the Intel
®
RAID Controller SRCU42E
Select a x8 PCI Express slot, and align the RAID Controller SRCU42E PCI bus connector to the slot. Press down gently but firmly to ensure that the card is properly seated in the slot, as shown in Figure 2.2. Then screw the bracket into the computer chassis.
Detailed Installation 21
Page 22
Figure 2.2 Inserting the Intel® RAID Controller SRCU42E in a x8 PCI Express* Slot
Press Here
Bracket S crew
Press Here
(3.3 V)
64-bit slots (5 V)
Edge of
server board
x8 PCI Express*
32-bit slot
slot
6) Set the Target IDs.
Set target identifiers (TIDs) on the SCSI devices. Each device in a channel must have a unique TID. Provide unique TIDs for non-disk devices (CD-ROM or tapes), regardless
®
of the channel where they are connected. The Intel
RAID Controller SRCU42E automatically occupies TID 7, which is the highest priority. The arbitration priority for a SCSI device depends on its TID.
Ta b l e 2- 1 Ta rg e t I D ’ s
Priority Highest Lowest
TID 7 6 5 . . . 2 1 0 15 14 . . . 9 8
Detailed Installation 22
Page 23
7) Connect SCSI devices to the Intel® RAID Controller SRCU42E. Use SCSI cables to connect SCSI devices to the RAID Controller SRCU42E. To connec t the SCSI devices:
a. Disable termination on any SCSI device that does not sit at the end of the SCSI bus. b. Configure all SCSI devices to supply TERMPWR. c. Connect cables to the SCSI devices. The maximum cable length for Fast SCSI (10
Mbytes/s) devices or SE is 3 meters; it is 1.5 meters for Ultra SCSI devices; it is 12 meters for LVD devices. You can connect up to 15 Ultra SCSI devices to each SCSI channel.
System throughput problems can occur if SCSI cables are not the correct type. To minimize the potential for problems:
Use cables no longer than 12 meters for Ultra160 and Ultra320 devices. – For SE SCSI devices, use the shortest SCSI cables (no longer than 3 meters
for Fast SCSI, no longer than 1.5 meters for an 8-drive Ultra SCSI system,
and no longer than 3 meters for a 6-drive Ultra SCSI system). – Use active termination. – Avoid clustering the cable nodes. – The cable stub length must be no greater than 0.1 meter (4 inch es.) – Use high impedance cables. – Route SCSI cables carefully.
8) Set SCSI Termination The SCSI bus is an electrical transmission line and must be terminated properly to
minimize reflections and losses. Set termination at each end of the SCSI cable(s). For a disk array, set SCSI bus termination so that removing or adding a SCSI device does
not disturb termination. An easy way to do this is to connect the RAID Controller SRCU42E to one end of the SCSI cable and to connect an external terminator module at the other end of the cable. You can then connect SCSI disk drives to the connectors between the two ends of the cable. If necessary, disable termination on the SCSI devices. (This is not necessary for Ultra320 and Ultra160 SCSI drives.)
Set the termination so that SCSI termination and TermPWR are intact when any disk drive is removed from a SCSI channel, as shown in Figure 2.3.
Detailed Installation 23
Page 24
Figure 2.3 Terminating an Internal SCSI Disk Array
Terminator
ID2 – No Termination
ID1 – No Termination
ID0 – Boot Drive No Termination
Intel RAID Controller SRCU42E SCSI ID 7
Host Computer
9) Power On Host System Replace the computer cover, and reconnect the AC power cords. Turn power on to the
host computer. Ensure that the SCSI devices are powered up at the same time as, or before, the host computer. If the computer is powered up before a SCSI device, the de vice might not be recognized.
During boot, a BIOS message appears. The firmware takes several seconds to initialize. During this time, the RAID Controller
SRCU42E scans the SCSI channel(s).
The BIOS Configuration utility prompt times out after several seconds. The second portion
®
of the BIOS message displays the Intel
RAID Controller SRCU42E number, firmware version, and cache SDRAM size. The numbering of the controllers follows the PCI slot scanning order used by the host system board.
Press <CTRL><G> to run BIOS Console
Detailed Installation 24
Page 25
2.4 After You Have Installed the RAID Controller
After installation, you must configure the RAID Controller SRCU42E and install the operating system driver. The Intel RAID Software User’s Guide instructs you about the configuration options and how to set them on your RAID Controller SRCU42E.
After You Have Installed the RAID Controller 25
Page 26
Chapter 3 Intel Reference
This chapter describes the characteristics of the Intel® RAID Controller SRCU42E. This chapter contains the following sections:
Section 3.1, “Overview,” page 26
Section 3.2, “Intel
Section 3.3, “Technical Specifications,” page 28
3.1 Overview
The Intel® RAID Controller SRCU42E is used in systems that have a x8 PCI Express* slot with a PCI-standard bracket type.
®
RAID Controller SRCU42E Technical
®
RAID Controller SRCU42E Characteristics,” page 28
PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture for a variety of systems, including desktops, workstations, mobile, server, communications, and embedded devices.
Figure 3.1 Intel® RAID Controller SRCU42E Layout
J12 Channel 0
External
Ultra-High
Density
68-pin SCSI
Connector
J14 Channel 1
External
Ultra-High
Density
68-pin SCSI
Connector
Internal High-Density
J6
J5
68-pin SCSI Connector
J9 Ch 0 Int
J15
J16
Internal High-Density
68-pin SCSI Connector
J10 Ch1 Int
J1 J2J3
J11
J4 J7
Intel RAID Controller SRCU42E 26
Page 27
Table 3-1Intel® RAID Controller SRCU42E Headers and Connectors
Connector Description Type Comments
J1 Write Pending Indicator
(Dirty Cache LED)
2-pin header Connector for enclosure LED to
indicate when data in the cache has yet to be written to the device. Optional.
J2 Onboard BIOS Enable 2-pin header No jumper = Enabled (Default
setting) Jumpered = Disabled
J3 SCSI Activity 2-pin header Connector for enclosure LED to
indicate data transfers. J4 I2C Header 3-pin connector Reserved J5 SCSI Ter mination Enable
Channel 0
3-pin connector Jumper pins 1-2 to enable software
control of SCSI termination via dri ve
detection. J6 SCSI Ter mination Enable
Channel 1
3-pin connector
Jumper pins 2-3 to disable onboard
SCSI termination.
No jumper installed enables onboard
SCSI termination. (See J17 and
J18). This is the default. J7 Serial Port (RS232) 3-pin header Connector is for diagnostic
purposes.
Pin-1 RXD (Receive Data)
Pin-2 TXD (Transmit Data)
Pin-3 GND (Ground) J9 Internal SCSI Channel 0
connector
68-pin header Internal high-density SCSI bus
connector. Connection is optional.
J10 Internal SCSI Channel 1
connector
68-pin header Internal high-density SCSI bus
connector. Connection is optional.
J11 Mode Select 2-pin connector Reserved J12 External SCSI Channel 0
connector
J14 External SCSI Channel 1
connector
68-pin header External very-high density SCSI bus
connector. Connection is optional.
68-pin header External very-high density SCSI bus
connector. Connection is optional.
J15 Ter mination Power 2-pin connector J16 Ter mination Power 2-pin connector
Overview 27
Page 28
3.2 Intel® RAID Controller SRCU42E Characteristics
Table 3-2 shows the general characteristics for the RAID Controller SRCU42E .
Table 3-2 Intel® RAID Controller SRCU42E Characteristics
Flash ROM
Yes Yes 16-bit SE
1. For boot code and firmware
1
Serial
EEPROM
LVD/SE
Signaling
or LVD
interfaces
3.3 Technical Specifications
The design and implementation of the RAID Controller SRCU42E minimizes electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The RAID Controller SRCU42E carries the CE mark, C-Tick mark, FCC Self-Certification logo, Canadian Compliance Statement, Korean MIC, Taiwan BSMI, and Japan VCCI, and they meet the requirements of CISPR Class B.
3.3.1 RAID Controller Specifications
Table 3-3 lists the specifications for the RAID Controller SRCU42E .
Table 3-3 Intel® RAID Controller SRCU42E Specifications
Ultra320 SCSI
Data Transfers
Up to 320 Mbytes/s as well as Fast, Ultra, Ultra2, and Ultra160 speeds; Synchronous offsets up to
62.
SCSI
Features
Plug n Play
Scatter/Gather
Activity LED
SCSI
Termination
Active: Single
Ended or LVD
Specification Description
Processor (PCI Controller)
Operating Voltage 3.3 V, +12 V Card Size Half-length PCI RAID controller size (6.875" X 4.2") Array Interface to
Host PCI Bus Data
Tr ans f er R ate Serial Port
SCSI Controller(s) SCSI Connectors
SCSI Bus Termination
Term ination Disable Automatic through cable and device detection
Intel® 80332 I/O processor @ 500 MHz
x8 PCI Express*
x8 PCI Express host data transfer rate
3-pin RS232C-compatible connector (for manufacturing use only)
One LSI* 53C1030 Dual SCSI controller Two 68-pin inter nal high-density connectors for SCSI
devices. Two very high-density 68-pin external connectors for Ultra320 and Wide SCSI.
Active: single-ended or LVD
Intel® RAID Controller SRCU42E Characteristics 28
Page 29
Table 3-3 Intel® RAID Controller SRCU42E Specifications (Cont.)
Specification Description
Cache Configuration 128-, 2 56-, or 512 Mbyte DDR1 ECC PC2700 DDR333 Double-Sided Dual
Inline Memory Modules (DIMMs)
Size of Flash ROM for Firmware
Nonvolatile Random Access Memory (RAM)
Yes
1 Mbyte flash ROM
32 Kbyte for storing RAID configuration
3.3.2 Array Performance Features
Table 3-4 shows the RAID Controller SRCU42E array performance features:
Ta ble 3-4 Array Performance Features
Specification Intel RAID Controller SRCU42E
x8 PCI Express Host Data Transfer Rate
Drive Data Transfer Rate
Maximum Scatter/Gathers
2 Gbytes/second full duplex (4 Gbyte/second total) theoretical
320 Mbytes/second per SCSI channel
26 elements
Maximum Size of I/O Requests
Maximum Queue Tags per Drive
Stripe Sizes 2, 4, 8, 16, 32, 64, or 128 Kbyte Maximum Number of
Concurrent Commands
Support for Multiple Initiators
6.4 Mbytes in 64 Kbyte stripes
As many as the drive can accept
255
Yes
Technical Specifications 29
Page 30
3.3.3 Fault Tolerance
Table 3-5 shows the RAID Controller SRCU42E fault tolerance features:
Ta ble 3-5 Fault Tolerance Features
Specification Intel Raid Controller SRCU42E
Support for SMART
1
Yes
Optional Battery Backup for Cache Memory
Drive Failure Detection
Drive Rebuild Using Hot Spares
Parity Generation and Checking
1. The Self Monitoring Analysis and Repor ting Tech nology (SMART) detects up to 70 percent of all predictable disk drive failures. SMART also monitors the internal performance of all motors, heads, and drive electronics.
3.3.4 Electrical Characteristics
This section provides the power requirements for the Intel® RAID Controller SRCU42E. Table 3-6 lists the maximum power requirements, which include SCSI TERMPWR, under normal operation.
Table 3-6 Maximum Power Requirements
RAID Controller
PCI Express +3.3 V
Yes. Up to 72 hours of data retention for 128 Mbyte
Automatic
Automatic
Yes
PCI Express 12 V
PCI PRSNT1#/ PRSNT2# Power
Over the Operating Range
®
Intel
RAID Controller SRCU42E
1.5 A 1.4 A without batter y
1.6 A when battery is charging
3.3.5 Thermal and Atmospheric Characteristics
The Intel® RAID Controller SRCU42E has the following thermal, atmospheric, and safety characteristics.
Temperature range: 0°C to 55°C (dry bulb)
Relative humidity range: 5% to 90% noncondensing
Maximum dew point temperature: 32°C
Airflow must be sufficient to keep the heat sink temperature below 80°C
The following parameters define the storage and transit environment for the Intel Controller SRCU42E:
Temperature range: −40°C to +105°C (dry bulb)
Relative humidity range: 5% to 90% noncondensing
Technical Specifications 30
25 W 0 °C to 55 °C
®
RAID
Page 31
3.3.6 Safety Characteristics
The Intel® RAID Controller SRCU42E meets or exceeds the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier’s name or trademark, type, and UL flammability rating. Since these boards are installed in a PCI bus slot, all voltages are below the SELV 42.4 V limit.
Technical Specifications 31
Page 32
Chapter A Glossary of Terms and Abbreviations
Active Termination
The electrical connection required at each end of the SCSI bus, composed of active voltage regulation and a set of termination resistors. Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, and Ultra320 SCSI require active termination.
BIOS Basic Input/Output System. Software that provides basic read/write capability. Usually kept
as firmware (ROM based). The system BIOS on the mainboard of a computer is used to boot and control the system. The SCSI BIOS on your host controller acts as an extension of the system BIOS.
Configuration Refers to the way a computer is setup; the combined hardware components (computer,
monitor, keyboard, and peripheral devices) that make up a computer system; or the software settings that allow the hardware components to communicate with each other.
Device Driver A program that allows a microprocessor (through the operating system) to direct the operation
of a peripheral device.
Differential SCSI
A hardware configuration for connecting SCSI devices. It uses a pair of lines for each signal transfer (as opposed to Single-Ended SCSI which references each SCSI signal to a common ground).
Domain Validation
EEPROM Electronically Erasable Programmable Read Only Memory.
Domain Validation is a software procedure in which a host queries a device to determine its ability to communicate at the negotiated Ultra320 data rate.
External SCSI Device
Fusion-MPT Architecture
A SCSI device installed outside the computer cabinet. These devices are connected together using specific types of shielded cables.
Fusion-MPT (Message Passing Technology) architecture consists of several main elements: Fusion-MPT firmware, the Fibre Channel and SCSI hardware, and the operating system level drivers that support these architectures. Fusion-MPT architecture offers a single binary, operating system driver that supports both Fibre Channel and SCSI devices now.
Host The computer system in which the RAID controller is installed. It uses the RAID controller
to transfer information to and from devices attached to the SCSI bus.
Host Adapter Board (HAB)
Internal SCSI Device
Main Memory The part of a computer’s memory which is directly accessible by the CPU (usually
A circuit board or integrated circuit that provides a device connection to the computer system.
A SCSI device installed inside the computer cabinet. These devices are connected together using an unshielded ribbon cable.
synonymous with RAM).
NVRAM NonVolatile Random Access Memory.
32
Page 33
PCI Express* Peripheral Component Interconnect. A high performance local bus specification that allows
connection of devices directly to computer memory. The PCI Local Bus allows transparent upgrades from 32-bit data path at 33 MHz to 64-bit data path at 33 MHz, and from 32-bit data path at 66 MHz to 64-bit data path at 66 MHz.
Peripheral Devices
A piece of hardware (such as a video monitor, disk drive, printer, or CD-ROM) used with a computer and under the computer’s control. SCSI peripherals are controlled through a SCSI RAID controller (host controller).
SCSI Bus A RAID controller (host controller) and one or more SCSI peripherals connected by cables
in a linear configuration. The controller may exist anywhere on the bus, allowing connection of both internal and external SCSI devices. A system may have more than one SCSI bus by using a multi-channel controller or by using multiple controllers.
SCSI Device Any device that conforms to the SCSI standard and is attached to the SCSI bus by a SCSI
cable. This includes SCSI RAID controllers (host controllers) and SCSI peripherals.
SCSI ID A way to uniquely identify each SCSI device on the SCSI bus. Each SCSI bus has eight
available SCSI IDs numbered 0 through 7 (or 0 through 15 for Wide SCSI). The RAID controller (host controller) usually gets the highest ID (7 or 15) giving it priority to control the bus.
Single-Ended SCSI
A hardware specification for connecting SCSI devices. It references each SCSI signal to a common ground. This is the most common method (as opposed to differential SCSI, which uses a separate ground for each signal).
TolerANT A technology developed and used by Intel to improve data integrity, data transfer rates, and
noise immunity through the use of active negation and input signal filtering.
Ultra SCSI A standard for SCSI data transfers. It allows a transfer rate of up to
20 Mbytes/s over an 8-bit SCSI bus and up to 40 Mbytes/s over a 16-bit SCSI bus.
Ultra2 SCSI A standard for SCSI data transfers. It allows a transfer rate of up to
40 Mbytes/s over an 8-bit SCSI bus, and up to 80 Mbytes/s over a 16-bit SCSI bus.
Ultra160 SCSI A standard for SCSI data transfers. It allows a transfer rate of up to 160 Mbytes/s over a 16-
bit SCSI bus.
Ultra320 SCSI A standard for SCSI data transfers. It allows a transfer rate of up to 320 Mbytes/s over a 16-
bit SCSI bus.
VHDCI Very High-Density Cable Interconnect. This cable is used to connect external connectors to
your RAID controller.
33
Loading...