Intel SR1680MV - Server System - 0 MB RAM Service Manual

Page 1
Intel® Server System SR1680MV Service Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products
Intel Order Number E74835-005
Page 2
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability , or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult v endor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. All Rights Reserved
ii Intel® Server System SR1680MV Service Guide
Page 3
Preface
About this Manual
Thank you for purchasing and using the Intel® Server System SR1680MV.
This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides a brief overview of the board features, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel
http://support.intel.com/support/motherboards/server/SR1680MV/.
Manual Organization
Chapter 1 provides a brief overview of the Intel® Server System SR1680MV. In this chapter, you will find a list of the system features, photos of the product, and product diagrams to help you identify components and their locations.
®
Server System SR1680MV. For the latest version of this manual, see
Chapter 2 provides instructions on adding and replacing components. Use this chapter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
Chapter 3 provides information on the cable connection. Use this chapter for detailed information on the cable connections and connector locations.
Chapter 4 provides the description of the functions of all server board jumpers, and connectors.
Chapter 5 describes the update process and configure features of the system BIOS.
Chapter 6 provides an overview of the embedded SATA RAID options and how to configure RAID sets.
Chapter 7 provides instructions for installing rail kit to racks.
At the back of this book, you will find an issue report form, troubleshooting information, regulatory information, and safety information.
Intel® Server System SR1680MV Service Guide iii
Page 4
Product Contents, Order Options, and Accessories
Your Int el® Server System SR1680MV ships with the following items:
One 1U chassis
Two Server Boards
Two Riser Cards
Two 2.5-inch SATA HDD backplanes
One left I/O board
One right I/O board
Four Hot-Swap 2.5-inch HDD trays
Two NIC Boards
One Power Distribution Board
Six System Fans
Four CPU Heatsinks
One unit Rack Bracket
Screws for 2.5-inch HDD
One 1100-W power supply
In addition, you may need or want to purchase one or more of the following accessory items for your server:
Processor, memory DIMMs, hard drive, and operating system.
For information about which accessories, memory, processors, and third-party hardware were tested and can be used with your board, and for ordering information for Intel products, see
http://support.intel.com/support/motherboards/server/SR1680MV/compat.htm.
Additional Information and Software
Documentation and software for this server product are available on the Intel Resource CD-ROM that shipped with your Intel server product. You can obtain software updates and additional information at the following Intel website:
http://support.intel.com/support/motherboards/server/SR1680MV/
iv Intel® Server System SR1680MV Service Guide
Page 5
Unless otherwise indicated in the following table, once on this webpage, type the document or software name in the search field at the left side of the screen and select the option to search “This Product.”
Additional Information and Software
For this information or
software
For in-depth technical information about this product, including BIOS settings and chipset information
If you just received this product and need to install it
Accessories or other Intel server products
Hardware (peripheral boards, adapter cards, and so forth) and operating systems that were tested with this product
Processors that were tested with this product
DIMMs that were tested with this product
For drivers Driver (for an extensive list of drivers available)
®
Intel
Server System SR1680MV Technical Product Specification
®
Intel
Server System SR1680MV Quick Start User's Guide in the
product box
Spares and Configuration Guide
Tested Hardware Operating Systems List
Supported Processors List
Supported Memory List
Operating System Driver (for operating system drivers)
Use this Document or Software
For firmware and BIOS updates
To make sure your system falls within the allowed power budget
Intel® Server System SR1680MV Service Guide v
Firmware Update Package
Power Budget Tool
Page 6
vi Intel® Server System SR1680MV Service Guide
Page 7
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Resource CD and/or at http://support.intel.com/support/motherboards/
Intel
server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Resource CD oder unter
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Resource CD ou bien rendez-vous sur le
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel motherboards/server/sb/cs-010770.htm.
®
Server Resource CD y/o en http://support.intel.com/support/
Intel® Server System SR1680MV Service Guide vii
Page 8
䞡㽕ᅝܼᣛᇐ
೼ᠻ㸠ӏԩᣛҸПࠡˈ䇋䯙䇏ᴀ᭛ḷЁⱘ᠔᳝⊼ᛣџ乍ঞᅝܼໄᯢDŽ៪ http://support.intel.com/support/motherboards/server/sb/CS-010770.htmϞⱘ,QWHO 6HUYHU%RDUGVDQG6HUYHU&KDVVLV6DIHW\,QIRUPDWLRQ˄lj,QWHO ᳡ࡵ఼ЏᵓϢ᳡ࡵ఼ᴎㆅᅝֵܼᙃNJ˅DŽ
viii Intel® Server System SR1680MV Service Guide
Page 9
Warnings
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1680MV Service Guide ix
Page 10
x Intel® Server System SR1680MV Service Guide
Page 11
Table of Contents
Preface ........................................................................................................................iii
About this Manual ................................................................................................................. iii
Manual Organization ............................................................................................................. iii
Product Contents, Order Options, and Accessories ............................................................. iv
Additional Information and Software .....................................................................................iv
Safety Information ....................................................................................................vii
Important Safety Instructions ............................................................................................... vii
Wichtige Sicherheitshinweise .............................................................................................. vii
Consignes de sécurité ......................................................................................................... vii
Instrucciones de seguridad importantes .............................................................................. vii
Warnings ...............................................................................................................................ix
Chapter 1: Server System Features ..........................................................................1
System Overview ...................................................................................................................3
Server Chassis Layout ..................................................................................................3
Front View Components ................................................................................................4
Back View Components ................................................................................................4
Buttons and System LEDs .....................................................................................................5
Front Panel Buttons and LEDs ......................................................................................5
Rear Panel Button and LEDs ........................................................................................6
LED Information .............................................................................................................6
Chapter 2: Hardware Installations and Upgrades ...................................................9
Before You Begin ...................................................................................................................9
Tools and Supplies Needed ..........................................................................................9
System References .....................................................................................................10
Power Off .....................................................................................................................10
Mid-Top Cover .....................................................................................................................11
Removing the Mid-Top Cover ......................................................................................11
Central Processing Unit (CPU) ....................................................................................12
Removing the Processor .............................................................................................13
Installing the Processor ...............................................................................................15
Removing the Heatsink ...............................................................................................16
Installing the Heatsink .................................................................................................17
System Memory ...........................................................................................................17
System Memory Channel Population Requirements for Memory RAS Modes ....................19
Independent Channel Mode ........................................................................................19
Mirrored Channel Mode ...............................................................................................19
Lockstep Channel Mode ..............................................................................................19
Intel® Server System SR1680MV Service Guide xi
Page 12
Removing a DIMM ......................................................................................................21
Installing a DIMM ........................................................................................................21
Server Board Cage Module .........................................................................................23
Left and Right I/O Board Cage Modules .............................................................................25
Removing the Left I/O Board Cage Module ................................................................26
Power Supply Module .........................................................................................................27
Removing the Power Supply Module .......................................................................... 27
Installing the Power Supply Module ............................................................................ 28
Power Distribution Board .....................................................................................................28
Removing the Power Distribution Board .....................................................................29
Installing the Power Distribution Board .......................................................................29
Pluggable SATA Drive .........................................................................................................30
2.5-inch Pluggable SATA HDD ...........................................................................................30
Removing a 2.5-inch Pluggable SATA HDD ............................................................... 30
Installing a 2.5-inch Pluggable SATA HDD .................................................................32
2.5-inch Pluggable HDD Backplane .................................................................................... 32
Removing an HDD Backplane ....................................................................................33
Installing a 2.5-inch Pluggable SATA HDD Backplane ...............................................33
System Fans .......................................................................................................................33
Removing a System Fan .............................................................................................34
Installing a System Fan ...............................................................................................35
Air Duct ................................................................................................................................35
Removing the IOB Air Duct ......................................................................................... 35
Installing Air Ducts ......................................................................................................36
PCI-E Cage .........................................................................................................................36
Removing a PCI-E Cage .............................................................................................36
Installing a PCI-E Cage ...............................................................................................38
Daughter Cards (Optional) .......................................................................................... 38
Removing the IO Expansion Module ...........................................................................39
Installing the IO Expansion Module .............................................................................41
Chapter 3: Cable Connections .................................................................................43
Connectors and Pin 1 Locations .................................................................................43
Cable Connections ...................................................................................................... 44
Chapter 4: Connectors, Jumpers, and LEDs ..........................................................47
Connector and Component Locations of Server Board .......................................................47
Connector and Component Locations of IO Board .............................................................49
Connector and Component Locations of NIC Board ........................................................... 50
Connectors and Components of Front Panel ...................................................................... 51
10 GB IO Card (Optional Daughter Card) ...........................................................................52
InfiniBand Card (Optional Daughter Card) ..........................................................................53
Connector and Component Locations of HDD Backplane ..................................................54
Connectors and Component Locations of PDB ...................................................................55
xii Intel® Server System SR1680MV Service Guide
Page 13
Chapter 5: BIOS Setup and Configuration .............................................................59
BIOS Setup Utility ........................................................................................................59
Entering the BIOS Setup Utility ...................................................................................60
Main Menu ...................................................................................................................63
Advanced Menu ...........................................................................................................64
SATA Configuration Submenu ....................................................................................67
Super IO Chipset Submenu .........................................................................................74
USB Configuration Submenu ......................................................................................76
USB Mass Storage Device Configuration Submenu ...................................................78
PCI Express* Configuration Submenu ........................................................................80
IPMI Configuration Submenu ......................................................................................81
View BMC System Event Log Submenu .....................................................................83
Remote Access Configuration Submenu .....................................................................84
Boot Menu ...................................................................................................................85
Boot Setting Configuration Submenu ..........................................................................86
Boot Device Priority Submenu .....................................................................................88
Removable Drives Submenu .......................................................................................89
CD/DVD Drives Submenu ...........................................................................................90
Security Menu ..............................................................................................................91
Trusted Computing Submenu ......................................................................................93
Exit Menu .....................................................................................................................95
BIOS Updates ..............................................................................................................96
ROM Flash ..................................................................................................................96
Chapter 6: Embedded SATA RAID ..........................................................................99
Enabling RAID in the BIOS Setup ...............................................................................99
Chapter 7: Installing the Rackmount Rail Kits .....................................................101
Procedure to install the rail kit ............................................................................................102
Appendix A: Intel® Server Issue Report Form .....................................................105
Appendix B: Troubleshooting ...............................................................................111
Resetting the System .........................................................................................................111
Problems following Initial System Installation ....................................................................111
First Steps Checklist ..................................................................................................111
Hardware Diagnostic Testing .............................................................................................112
Verifying Proper Operation of Key System Lights .....................................................113
Confirming Loading of the Operating System ............................................................113
Specific Problems and Corrective Actions .........................................................................113
Power Light Does Not Light .......................................................................................113
No Characters Appear on Screen .............................................................................114
Characters Are Distorted or Incorrect ........................................................................114
System Cooling Fans Do Not Rotate Properly ..........................................................115
Cannot Connect to a Server ......................................................................................115
LED Information .........................................................................................................116
Intel® Server System SR1680MV Service Guide xiii
Page 14
BIOS POST Beep Codes .......................................................................................... 116
Appendix C: Installation/Assembly Safety Instructions .....................................119
English ...............................................................................................................................119
Deutsch .............................................................................................................................121
Français .............................................................................................................................123
Español .............................................................................................................................125
Italiano ...............................................................................................................................127
Appendix D: Safety Information ............................................................................131
English ...............................................................................................................................131
Server Safety Information .........................................................................................131
Safety Warnings and Cautions ..................................................................................131
Intended Application Uses ........................................................................................ 132
Site Selection ............................................................................................................132
Equipment Handling Practices ..................................................................................132
Power and Electrical Warnings .................................................................................133
Access Warnings ......................................................................................................133
Electrostatic Discharge (ESD) ...................................................................................134
Other Hazards ...........................................................................................................134
Deutsch .............................................................................................................................135
Sicherheitshinweise für den Server ...........................................................................135
Sicherheitshinweise und Vorsichtsmaßnahmen .......................................................136
Zielbenutzer der Anwendung ....................................................................................136
Standortauswahl .......................................................................................................136
Handhabung von Geräten .........................................................................................137
Warnungen zu Netzspannung und Elektrizität ..........................................................138
Warnhinweise für den Systemzugang .......................................................................138
Elektrostatische Entladungen (ESD) ......................................................................... 139
Andere Gefahren .......................................................................................................140
Français .............................................................................................................................141
Consignes de sécurité sur le serveur ........................................................................141
Sécurité: avertissements et mises en garde .............................................................141
Domaines d’utilisation prévus ...................................................................................142
Sélection d’un emplacement ..................................................................................... 142
Pratiques de manipulation de l’équipement ..............................................................142
Alimentation et avertissements en matière d’électricité ............................................ 143
Avertissements sur l’accès au système ....................................................................143
Décharges électrostatiques (ESD) ............................................................................144
Autres risques ...........................................................................................................144
Español .............................................................................................................................145
Información de seguridad del servidor ......................................................................145
Advertencias y precauciones sobre seguridad .........................................................145
Aplicaciones y usos previstos ...................................................................................146
Selección de la ubicación ..........................................................................................146
xiv Intel® Server System SR1680MV Service Guide
Page 15
Manipulación del equipo ............................................................................................147
Advertencias de alimentación y eléctricas .................................................................147
Advertencias el acceso al sistema ............................................................................148
Descarga electrostática (ESD) ..................................................................................149
Otros peligros ............................................................................................................149
简体中文 .....................................................................151
Appendix E: Regulatory and Certification Information .......................................157
Product Regulatory Compliance ........................................................................................157
Product Safety Compliance .......................................................................................158
Product EMC Compliance - Class A Compliance ......................................................158
Product Ecology Compliance ....................................................................................159
Certifications / Registrations / Declarations ...............................................................159
Product Regulatory Compliance Markings ................................................................160
Rack Mount Installation Guidelines ...................................................................................165
Power Cord Usage Guidelines ..........................................................................................166
Electromagnetic Compatibility Notices ..............................................................................168
FCC Verification Statement (USA) ............................................................................168
ICES-003 (Canada) ...................................................................................................169
CE Declaration of Conformity (Europe) .....................................................................169
VCCI (Japan) .............................................................................................................169
BSMI (Taiwan) ...........................................................................................................170
KCC (Korea) ..............................................................................................................170
Regulated Specified Components .....................................................................................170
Appendix F: Warranty ............................................................................................173
Appendix G: Getting Help ......................................................................................175
Intel® Server System SR1680MV Service Guide xv
Page 16
xvi Intel® Server System SR1680MV Service Guide
Page 17
List of Figures
Figure 1. Intel® Server System SR1680MV with 2.5-inch Pluggable HDDs.............................. 1
Figure 2. Layout of Server Chassis with 2.5-inch Pluggable HDDs.......................................... 3
Figure 3. Front View of Server with 2.5-inch Pluggable HDDs.................................................. 4
Figure 4. Back View .................................................................................................................. 5
Figure 5. Front Panel Buttons and LEDs of Server................................................................... 5
Figure 6. Back View LEDs and Buttons of Two I/O Boards ...................................................... 6
Figure 7. Pressing the Power Button....................................................................................... 10
Figure 8. Unplugging the Power Cord..................................................................................... 11
Figure 9. Removing the Mid-Top Cover.................................................................................. 12
Figure 10. Location of Processors........................................................................................... 12
Figure 11. Opening the Load Plate ......................................................................................... 13
Figure 12. Lifting the Processor Out of the Socket.................................................................. 14
Figure 13. Placing on the PnP Cap......................................................................................... 14
Figure 14. Closing the Load Plate........................................................................................... 15
Figure 15. Pointing the Golden Corner Toward the Socket..................................................... 16
Figure 16. Removing the Heatsink.......................................................................................... 17
Figure 17. Location of System Memories................................................................................ 18
Figure 18. DIMM Socket Location........................................................................................... 18
Figure 19. Lifting the DIMM Out of the Socket........................................................................ 21
Figure 20. Pressing the Retaining Clips Outward ................................................................... 22
Figure 21. Inserting the DIMM into the Socket........................................................................ 22
Figure 22. Server Board Cage Module with 2.5-inch Pluggable SATA HDD Location............ 23
Figure 23. Releasing the Locking Latch.................................................................................. 23
Figure 24. Pull the Locking Lever to Remove the Server Board Cage Module....................... 24
Figure 25. Left I/O Board Cage Module Location.................................................................... 25
Figure 26. Right I/O Board Cage Module Location................................................................. 25
Figure 27. Slide the Locking Latch.......................................................................................... 26
Figure 28. Pull the Locking Lever to Remove the Left I/O Board Cage Module...................... 26
Figure 29. Power Supply Location.......................................................................................... 27
Figure 30. Removing the Power Supply Module..................................................................... 28
Figure 31. Power Distribution Board ....................................................................................... 28
Figure 32. Removing the Power Distribution Board................................................................ 29
Figure 33. 2.5-inch Pluggable SATA HDD Location................................................................ 30
Figure 34. Release the Locking Lever..................................................................................... 31
Figure 35. Pull the Locking Lever to Remove the HDD Carrier............................................... 31
Figure 36. Release Screws and Lift the HDD Up.................................................................... 32
Figure 37. 2.5-inch Pluggable HDD Backplane Location........................................................ 32
Figure 38. Remove the Screws and Lift the Backplane Up..................................................... 33
Figure 39. System Fans Location............................................................................................ 34
Figure 40. Lift a System Fan Up from I/O Board Cage Module............................................... 34
Figure 41. Lift Air Duct Up....................................................................................................... 35
Figure 42. PCI-E Cage Location ............................................................................................. 36
Intel® Server System SR1680MV Service Guide xvii
Page 18
Figure 43. Lifting the PCI Cage from the I/O Board Module................................................... 37
Figure 44. Removing the Expansion Card.............................................................................. 37
Figure 45. Securing the Slot Cover......................................................................................... 38
Figure 46. Removing the Riser Card ...................................................................................... 38
Figure 47. 10 GB IO Card Location .................................................. ...................................... 39
Figure 48. InfiniBand Card Location ................................................. ........... ........................... 39
Figure 49. Lifting the Module Upward from the IO Board....................................................... 40
Figure 50. Removing the Module Upward from the IO Board................................................. 40
Figure 51. Locations of Connectors and Pin 1 on Server Board............................................. 43
Figure 52. Locations of Connectors and Pin 1 on I/O Board.................................................. 44
Figure 53. Connecting the System Fan Cables...................................................................... 45
Figure 54. Connectors and Component Locations of Server Board....................................... 47
Figure 55. Connectors and Component Locations of IO Boards............................................ 49
Figure 56. Connectors and Component Locations of NIC Board............................................ 50
Figure 57. Connectors and Component Locations of Front Panel.......................................... 51
Figure 58. Connectors and Components of 10 GB IO Card................................................... 52
Figure 59. Connectors and Components of InfiniBand Card.................................................. 53
Figure 60. Connectors and Components of 2.5-inch Pluggable HDD Backplane................... 54
Figure 61. Connectors and Component Locations of PDB..................................................... 55
Figure 62. Location of MISC Jumper...................................................................................... 56
Figure 63. Location of ICH Function Jumper.......................................................................... 57
Figure 64. Overview of Rail Kit ............................................................................................. 101
Figure 65. Location Of Spring Screw Holes .......................................................................... 102
Figure 66. Secure screw into the rail hole............................................................................. 103
Figure 67. Secure the Rail to Racks..................................................................................... 103
Figure 68. Slide The Server Into Racks................................................................................ 103
Figure 69. Push The Server To The End Of Racks.............................................................. 104
Figure 70. Secure The Server Ears To Racks...................................................................... 104
xviii Intel® Server System SR1680MV Service Guide
Page 19
List of Tables
Table 1. Intel® Server System SR1680MV Feature Summary ..................................................2
Table 2. LED Information ..........................................................................................................6
Table 3. Ideal DIMM Installation Options for A-C Channels of Processor 1 ............................20
Table 4. Ideal DIMM Installation Options for D-F Channels of Processor 2 ............................20
Table 5. BIOS Setup Utility Screen Descriptions ....................................................................59
Table 6. Keyboard Command Bar Description ........................................................................60
Table 7. Main Menu of BIOS Setup Utility ...............................................................................63
Table 8. Main Menu Fields ......................................................................................................63
Table 9. Advanced Menu of BIOS Setup Utility .......................................................................64
Table 10. CPU Configuration Submenu ..................................................................................65
Table 11. CPU Configuration Submenu Fields .......................................................................65
Table 12. SATA Configuration Submenu1 ..............................................................................67
Table 13. SATA Configuration Submenu2 ..............................................................................68
Table 14. SATA Configuration Submenu3 ..............................................................................69
Table 15. SATA Configuration Submenu4 ..............................................................................70
Table 16. SATA Configuration Submenu Fields ......................................................................71
Table 17. Primary/Secondary IDE Master/Slave .....................................................................72
Table 18. Primary/Secondary IDE Master/Slave Submenu Field ............................................73
Table 19. Super IO Chipset Submenu ....................................................................................74
Table 20. SATA Configuration Submenu Fields ......................................................................75
Table 21. USB Configuration Submenu ..................................................................................76
Table 22. USB Configuration Submenu Fields ........................................................................76
Table 23. USB Mass Storage Device Configuration Submenu ...............................................78
Table 24. USB Mass Storage Device Configuration Submenu Fields ....................................79
Table 25. PCI Express* Configuration Submenu ....................................................................80
Table 26. PCI Express* Configuration Submenu Fields ..........................................................80
Table 27. IPMI Configuration Submenu ..................................................................................81
Table 28. IPMI Configuration Submenu Fields ........................................................................82
Table 29. View BMC System Event Log Submenu .................................................................83
Table 30. Remote Access Configuration Submenu ................................................................84
Table 31. Remote Access Configuration Submenu Fields ......................................................84
Table 32. Boot Menu of BIOS Setup Utility .............................................................................85
Table 33. Boot Setting Configuration Submenu of BIOS Setup Utility ....................................86
Table 34. Boot Setting Configuration Submenu Fields ...........................................................86
Table 35. Boot Device Priority Submenu ................................................................................88
Table 36. Removable Drives Submenu ...................................................................................89
Table 37. CD/DVD Drives Submenu .......................................................................................90
Table 38. Security Menu of BIOS Setup Utility ........................................................................91
Table 39. Security Menu Fields ...............................................................................................92
Table 40. Trusted Computing Submenu .................................................................................93
Table 41. Trusted Computing Submenu Fields .......................................................................94
Table 42. Exit Menu of BIOS Setup Utility ...............................................................................95
Intel® Server System SR1680MV Service Guide xix
Page 20
Table 43. BIOS Requirements Description ............................................................................. 96
Table 44. Recommended screwdrivers ................................................................................101
Table 45. Location and Adapt Depth for Racks ....................................................................102
Table 46. Resetting the System ............................................................................................111
Table 47. LED Information ....................................................................................................116
Table 48. POST Error Beep Codes ...................................................................................... 116
Table 49. Error Beep Codes Generated by Intel
®
Management Module .............................. 117
Table 50. Product Regulatory Compliance Markings ............................................................160
xx Intel® Server System SR1680MV Service Guide
Page 21
1 Server System Features
This chapter briefly describes the main features of the Intel® Server System SR1680MV. This chapter provides a photograph of the product, list of the server system features, and diagrams showing the location of important components and connections on the server system.
Figure 1. Intel
The sever supports two identical motherboards, left and right I/O boards. Two I/O boards have the same function with different placement. Based on the Intel platform, each server board uses high-performance, dual processors of the Intel 5500 Series, Intel can accelerate even the most complicated server tasks. The following highlights are the main features of one server board and one I/O board. For additional information, refer to this user manual.
Note: Except where indicated, all descriptions are based on one server board.
Note: The minimum configuration of the server system is to install the right server board. You
can only access the power supply when the right server board is installed. The corresponding I/O board must be fixed to the server board when powering on the system.
®
Server System SR1680MV with 2.5-inch Pluggable HDDs
®
5500 chipset
®
Xeon® 5600 Series, and Intel® ICH10R chipsets. Two server boards
®
Xeon®
Intel® Server System SR1680MV Service Guide 1
Page 22
Table 1 summarizes the features of the server chassis.
®
Table 1. Intel
Feature Description
Server System SR1680MV Feature Summary
Dimensions
43.2 mm height
448 mm width
714.2 mm depth
Minimum weight: 11.7 kg
Maximum weight: 17.16 kg
Processor
Memory
Support for up to four Intel
Intel® Xeon® 5600 Series (two per server node)
Three channels per processor; up to three DIMMs per channel
72 GB maximum per processor (8 GB DIMM)
Supports DDR3 speeds of 800/1066/1333 MHz
Supports up to three registered DIMMs per channel; 8 GB
maximum per registered DIMM
Supports up to two unbuffered DIMMs per channel; 4 GB
maximum per unbuffered DIMM
Supports single-rank (SR), dual-rank (DR), and quad-rank
(QR) DIMM modules
On-board LAN Dual Gigabit Ethernet ports
Network controllers embedded in Intel
Interface compatible with IEEE/ANSI 802.3
On-board VGA
Server Engines* Pilot II
One front VGA connector
®
Xeon® Processor 5500 Series and
®
82576 chipsets
Integrated Super I/O
Keyboard Style/BT interface for BMC support
Fully Functional Serial Port, compatible with the 16C550
Supports Serial IRQ
Supports SMI/SCI/PME
Apply ACPI compliant
Supports up to 32 shared GPIO ports
Supports Programmable Wake-up Event
Supports Plug and Play (PnP) Register Set
Power Supply Control
Watchdog timer compliant with Microsoft SHDG*
Real-time Clock (RTC) with the external RTC interface
Riser and Expansion Card
One PCI-E x8 slot on each I/O board to support a 25-W
maximum PCI-E riser
Supports a low-profile PCI-E expansion card on each riser
connector
2 Intel® Server System SR1680MV Service Guide
Page 23
System Overview
Server Chassis Layout
1. Power Supply 6. Server boards
2. I/O Boards 7. Pluggable HDD Backplane
3. PCI-E Cage 8. Pluggable HDD Bays
4. System Fans 9. NIC Card
5. Power Distribution Board 10. GB I/O Card or InfiniBand* Card
Figure 2. Layout of Server Chassis with 2.5-inch Pluggable HDDs
Intel® Server System SR1680MV Service Guide 3
(optional)
Page 24
Front View Components
The front view of this 1U server allows easy access to 2.5-inch pluggable SATA HDDs. Some connectors, buttons, and system LEDs of both internal and external devices are located on the front.
The following introduces the front view of the server with 2.5-inch pluggable HDDs:
1. VGA Port 7. UID Button
2. Serial Port 8.UID LED
3. NIC LED 9. Power LED
4. Front Panel USB Port 10. Front Panel USB Port
5. System Health LED 11. HDD LED
6. Power Button 12. 2.5-inch Pluggable HDDs
Figure 3. Front View of Server with 2.5-inch Pluggable HDDs
Back View Components
The server back view includes connectors, buttons, and system LEDs of both internal and external devices.
4 Intel® Server System SR1680MV Service Guide
Page 25
1. PCI-E Cages 4. Rear NIC2 Ports
2. AC Power Outlet 5. Rear UID LEDs
3. Rear NIC1 Ports 6. Rear UID Buttons
Buttons and System LEDs
Front Panel Buttons and LEDs
This server is equipped with system LED indicators, buttons, and two front panel USB ports located on the front panel. The front panel status LEDs allow constant monitoring of basic system functions while the server is operating. These LEDs provide visual cues to the status of NIC link, system health, UID (unique identifier), and power.
The following figures shows the front panel:
Figure 4. Back View
1. NIC LED 5. UID LED
2. System Health LED 6. Power LED
3. Power Button 7. HDD LED
4. UID Button
Intel® Server System SR1680MV Service Guide 5
Figure 5. Front Panel Buttons and LEDs of Server
Page 26
The back view LEDs and buttons information display details regarding the LEDs and buttons of the two I/O boards and AC power LED.
Rear Panel Button and LEDs
1. Rear UID Buttons 4. NIC 1&2 Link LEDs
2. Rear UID LEDs 5. AC Power LED
3. NIC 1&2 Activity LEDs
Figure 6. Back View LEDs and Buttons of Two I/O Boards
The following table provides detailed LED information.
LED Information
Table 2. LED Information
Feature Color Description
Front View LEDs
Pow er LED Amber On: System has AC power but in standby mode .
Green On: System has AC power and is turned on.
- Off: No AC power to the system.
6 Intel® Server System SR1680MV Service Guide
Page 27
Table 2. LED Informat i on
Feature Color Description
System Health LED Red Blinking: System has non-critical errors. After error
condition is cleared, LED is off. On: System has critical errors. LED needs to remain
active until the next power-off and power-on provided that the error condition is cleared.
- Off: System off / System OK.
HDD Activity LED Green Blinking: Drive activity
- Off: No drive activity
NIC 1&2 LED Green Blinking: Linked and activity on the network
On: Linked to network
- Off: LAN not connected
UID LED Blue Blinking: Command trigger
On: Identification
- Off: Disabled
Back View LEDs
NIC 0&1 Activity LED Green Blinking: Linked and activity on the network.
- Off: No connection
NIC 0&1 Link LED GREEN On: Linked to the network.
- Off: No connection
UID LED Blue Blinking: System is being remotely managed
On: Identification
- Off: Disabled
AC Power LED Green On: +12V is output
- Off: No AC on or no main power on
Intel® Server System SR1680MV Service Guide 7
Page 28
8 Intel® Server System SR1680MV Service Guide
Page 29
2 Hardware Installations and
Upgrades
Before You Begin
Before working with your server product, pay close attention to “Safety Information”.
This document provides instructions for adding and replacing system components. For instructions on replacing components on the server board, such as the processor and memory DIMMs, and PCI-E add-in cards.
In addition, this server is also designed with the tool-less feature, which permits to remove or install the components without any tools. The locking tab, retaining clip and so forth provide the convenient method to lock the components on the server chassis. The tool-less components are listed:
Motherboard Cage Modules
I/O Board Cage Modules
Power Supply Module
Power Distribution Board
System Fans
Air Ducts
System Battery
PCI Cage
2.5-inch Pluggable SATA HDDs
Note: The components shown in this chapter are mainly for your reference. Please take the
actual shipment as standard.
Tools and Supplies Needed
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Needle nosed pliers
Antistatic wrist strap and conductive foam pad (recommended)
Intel® Server System SR1680MV Service Guide 9
Page 30
System References
All references to left, right, front, top, and bottom assume the reader is facing the front of the chassis as it would be positioned for normal operation.
Power Off
Before any replacement, you must power off the server completely. Complete the following steps to power off the server completely.
Caution: To reduce the risk of injury from electric shock, remove the power cord to completely
disconnect power from the system.
Warning: Moving the Power On/Off switch to the Off position does not completely remove power
from the system. Some portions of the power supply and some internal circuitry remain active. Disconnect all power cords from the server to completely remove power from the system.
Pressing the Power Button
Press the power button (“1”) to toggle the serve to hibernation. The power LED (“2”) in TBD turns off.
10 Intel® Server System SR1680MV Service Guide
Figure 7. Pressing the Power Button
Page 31
Unplugging the Power Cord
You must first unplug the power cord from the AC outlet and then from the server.
Mid-Top Cover
Figure 8. Unplugging the Power Cord
The server is a 1U form factor designed for easy assembly and disassembly, making the replacement of internal components convenient.
Note: Before you remove or install the rear top cover, follow this step:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
Removing the Mid-Top Cover
1. Release the screw on the mid-top cover.
2. Press down the locking button along the direction of the arrow.
3. Simultaneously slide the mid-top cover forward in the direction of the arrow using the traction pad, and then lift it up.
Intel® Server System SR1680MV Service Guide 11
Page 32
Figure 9. Removing the Mid-Top Cover
Central Processing Unit (CPU)
Each installed server node provides two surface mount LGA 1366 CPU sockets designed for the Intel
®
Xeon® Processor 5500 series and Intel® Xeon® Processor 5600 series. One
server node can be configured to either a single- or dual-processor system.
The following figure shows the location of processors on the motherboard:
Figure 10. Location of Processors
12 Intel® Server System SR1680MV Service Guide
1. Processor 1
2. Processor 2
Page 33
You can install single or dual processors on the motherboard according to your own needs.
1. If a SINGLE processor is intended, it is recommended that you install the processor on the processor 1 socket. Refer to Figure 10.
2. If installing DUAL processors, use the same type of processor running at the same frequency.
Note: Before you remove or install the heatsink, processor or heatsink socket, complete the
following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”
2. Remove the chassis cover. To remove the cover, see “Mid-Top Cover”.
Removing the Processor
1. Unlock the load lever and lift it up.
2. Open the load plate.
3. Lift the processor out of the socket.
Intel® Server System SR1680MV Service Guide 13
Figure 11. Opening the Load Plate
Page 34
Figure 12. Lifting the Processor Out of the Socket
4. Place the PnP cap onto the load plate.
14 Intel® Server System SR1680MV Service Guide
Figure 13. Placing on the PnP Cap
Page 35
5. Close the load plate.
6. Lock the load lever.
Figure 14. Closing the Load Plate
Installing the Processor
Reverse the steps in “Removing the Processor” to install the processor. However, when inserting the processor into the socket, make sure the golden corner on the processor is pointed toward the socket.
Intel® Server System SR1680MV Service Guide 15
Page 36
Figure 15. Pointing the Golden Corner Toward the Socket
Note: When the processor is in place, press it firmly on the socket while you push down the
socket lever to secure the processor. The lever clicks on the socket indicating it is locked.
The processor fits only in one orientation. Do not force the processor into the socket to avoid bending the pins and damaging the processor. If the processor does not fit completely, check its orientation or check for bent pins
Removing the Heatsink
1. Loosen the two securing screws.
2. Lift the heatsink up from the installed processor.
16 Intel® Server System SR1680MV Service Guide
Page 37
Installing the Heatsink
Reverse the steps in “Removing the Heatsink” to install the heatsink. Make sure you put the heatsink in the right direction—you should see the heatsink information when you finish the heatsink installation.
Note: Before you put the heatsink on top of the installed processor, do not forget to check if the
grease is completely on the bottom of the heatsink. Put the two heatsinks with the 16-fin side facing the corresponding DIMM group.
System Memory
Each motherboard supports 18 DDR3 1333/1066/800 DIMMs depending on DIMM population and each processor supports up to three channels, one channel with three slots. Both registered DIMM and unbuffered DIMM modules are supported. One processor supports up to 72GB memory when 8GB DIMM is available.
Mixed memory is neither tested nor supported. Non-ECC memory is not tested and is not recommended for use in a server environment.
Figure 16. Removing the Heatsink
The location of DIMM sockets on the motherboard is shown in Figure 17:
Intel® Server System SR1680MV Service Guide 17
Page 38
Figure 17. Location of System Memories
There are 18 DIMMs on the motherboard to support processor 1 and processor 2. The DIMM sequence of 18 DIMM sockets is respectively shown in Figure 18.
18 Intel® Server System SR1680MV Service Guide
Figure 18. DIMM Socket Location
Page 39
System Memory Channel Population Requirements for Memory RAS Modes
The rules on channel population and channel matching vary by the RAS mode used. There are three different memory RAS modes: Independent Channel Mode, Mirrored Channel Mode, and Lockstep Channel Mode.
Note: Mirrored Channel Mode and Lockstep Channel Mode require matching populations that
the same slot positions across channels must hold the same DIMM type with regards to size and organization.
Independent Channel Mode
Channels can be populated in any order in this mode. All these channels may be populated in any order and have no matching requirements. All channels must run at the same interface frequency but individual channels may run at different DIMM timings (RAS latency, CAS latency, and so forth).
Mirrored Channel Mode
In Mirrored Channel Mode, the memory contents are mirrored between Channel 0 and Channel 1. As a result of the mirroring, the total physical memory available to the system is half of what is populated. Mirrored Channel Mode requires that Channel 0 and Channel 1 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 1 must be populated the same. Channel 2 is unused in Mirrored Channel Mode.
Lockstep Channel Mode
In Lockstep Channel Mode, each memory access is a 128-bit data access that spans Channel 0 and Channel 1. Lockstep Channel mode is the only RAS mode that supports x8 SDDC. Lockstep Channel Mode requires that Channel 0 and Channel 1 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 1 must be populated the same. Channel 2 is unused in Lockstep Channel Mode.
For your reference, Table 3 offers an ideal DIMM population option for A-F channels of processor 1 and 2. The last column in tables marks DIMM installation under Mirrored Channel Mode for your reference.
Intel® Server System SR1680MV Service Guide 19
Page 40
Table 3. Ideal DIMM Installation Options for A-C Channels of Processor 1
DIMM A3 A2 A1 B3 B2 B1 C3 C2 C1
1--V-- - ­2--V--V- ­3--V--V- - V 4-VV- V- V 5-VV-VV- V 6-VV-VV- V V 7VVV VV V V 8VVVVVV V V 9VVVVVVV V V
Table 4. Ideal DIMM Installation Options for D-F Channels of Processor 2
DIMM D3 D2 D1 E3 E2 E1 CF F2 F1
1--V-- - ­2--V--V- ­3--V--V- - V 4-VV- V- V 5-VV-VV- V 6-VV-VV- V V 7VVV VV V V 8VVVVVV V V 9VVVVVVV V V
Note: The empty DIMM socket is marked as “-” and installed DIMM socket is marked as “V”.
It is recommended to insert DIMM equally for each CPU so as to give maximizes system performance.
It is highly recommended that all DIMMs with same part number be used within one motherboard.
For Unbuffered DIMMs or Quad-rank Registered DIMMs, only configuration 1~6 could be supported.
Optional Note: For other Registered DIMMs, configuration 1~9 could be supported.
20 Intel® Server System SR1680MV Service Guide
Page 41
Before you remove or install any DIMMs, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the chassis cover. To remove the cover, see “Mid-Top Cover”.
Removing a DIMM
1. Unlock a DIMM socket by pressing the retaining clips outward. This action releases the module and partially lifts it out of the socket.
2. Lift out the DIMM.
Installing a DIMM
1. Unlock a DIMM socket by pressing the retaining clips outward.
Intel® Server System SR1680MV Service Guide 21
Figure 19. Lifting the DIMM Out of the Socket
Page 42
Figure 20. Pressing the Retaining Clips Outward
2. Align the notch on the DIMM to the break on the socket. Carefully insert the DIMM into the socket until the retaining clips snap back in place.
22 Intel® Server System SR1680MV Service Guide
Figure 21. Inserting the DIMM into the Socket
Page 43
Note: DIMMs fit in only one direction. DO NOT force a DIMM into the socket to avoid
damaging the DIMM.
Server Board Cage Module
This section explains how to replace the server board cage module from the chassis.
Figure 22. Server Board Cage Module with 2.5-inch Pluggable SATA HDD Location
Warning: When installing the server board cage module, make sure that you place it into the chassis
correctly. The edge with the external ports goes to the back panel of the chassis. When handling the server board cage module, avoid touching any metal leads or
connectors.
Removing the Server Board Cage Module
1. Slide the locking latch along the direction of the arrow.
2. The cage locking lever springs open by itself.
Intel® Server System SR1680MV Service Guide 23
Figure 23. Releasing the Locking Latch
Page 44
3. Pull the cage tray lever along the direction of the arrow to remove the module.
Figure 24. Pull the Locking Lever to Remove the Server Board Cage Module
Installing the Server Board Cage Module
Reverse the “Removing the Server Board Cage Module” steps to install the server board cage module.
24 Intel® Server System SR1680MV Service Guide
Page 45
Left and Right I/O Board Cage Modules
The left and right I/O board cage modules share the same steps during the removal and installation procedures. For your reference, this section takes the steps of removing and installing the left I/O board cage module as an example.
The location of the left and right I/O board cage modules on the server chassis is shown in the following figures:
Figure 25. Left I/O Board Cage Module Location
Note: Before you remove or install the server board, complete these steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Disconnect all necessary cable connections.
3. When removing and installing I/O board cage module, keep the handle of the power supply in the horizontal direction to avoid damage on it.
Intel® Server System SR1680MV Service Guide 25
Figure 26. Right I/O Board Cage Module Location
Page 46
Removing the Left I/O Board Cage Module
1. Slide the locking latch along the direction of the arrow.
2. The cage tray lever springs open by itself.
Figure 27. Slide the Locking Latch
3. Pull the cage tray lever along the direction of the arrow to remove the module.
Figure 28. Pull the Locking Lever to Remove the Left I/O Board Cage Module
Installing the Left I/O Board Cage Module
Reverse the above steps to install the left I/O board cage module.
26 Intel® Server System SR1680MV Service Guide
Page 47
Power Supply Module
This section introduces the replacement procedure for the power supply module. The following figure shows the location of power supply module on the server chassis:
Note: Before you remove or install the power supply, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
Figure 29. Power Supply Location
2. Disconnect all necessary cable connections.
Removing the Power Supply Module
1. Pull down the power supply handle in the horizontal direction.
2. Press the retaining clip on the left side of the power supply along the direction of the arrow.
3. Simultaneously pull out the power supply by using its handle. (The power supply takes considerable force to remove.)
Intel® Server System SR1680MV Service Guide 27
Page 48
Figure 30. Removing the Power Supply Module
Installing the Power Supply Module
Reverse the “Removing the Power Supply Module” steps to install the power supply module.
Power Distribution Board
This section introduces the replacement procedures of the power distribution board. Figure 31 shows the location of the power distribution board on the server chassis.
Note: Before you remove or install the power distribution board, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
28 Intel® Server System SR1680MV Service Guide
Figure 31. Power Distribution Board
Page 49
2. Remove the mid-top cover. To remove the cover, see “Mid-Top Cover”.
3. Disconnect all necessary cable connections.
Removing the Power Distribution Board
1. Lift the power distribution board from the chassis.
Figure 32. Removing the Power Distribution Board
Installing the Power Distribution Board
Reverse the “Removing the Power Distribution Board” steps to install the power distribution board.
Intel® Server System SR1680MV Service Guide 29
Page 50
Pluggable SATA Drive
2.5-inch Pluggable SATA HDD
The sever supports up to four 2.5-inch pluggable SATA HDDs, two on each server board module. Four HDDs share the same removal and installation procedure. For your reference, this section provides the steps of removing and installing one 2.5-inch pluggable SATA HDD as an example.
Figure 33 shows the location of the 2.5-inch pluggable SATA HDD on the server chassis:
Figure 33. 2.5-inch Pluggable SATA HDD Location
Note: Before you remove or install the pluggable HDD, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Disconnect all necessary cable connections.
3. Remove the HDD blank if the HDD blank is installed.
Removing a 2.5-inch Pluggable SATA HDD
1. Turn the lock counter-clockwise.
2. Slide the locking latch along the direction of the arrow.
3. The HDD carrier locking lever springs open by itself.
30 Intel® Server System SR1680MV Service Guide
Page 51
Figure 34. Release the Locking Lever
4. Pull the HDD carrier locking lever out along the direction of the arrow.
Figure 35. Pull the Locking Lever to Remove the HDD Carrier
5. Loosen and remove the four securing screws.
6. Lift the HDD up from the HDD carrier.
Intel® Server System SR1680MV Service Guide 31
Page 52
Figure 36. Release Screws and Lift the HDD Up
Installing a 2.5-inch Pluggable SATA HDD
Reverse the “Removing a 2.5-inch Pluggable SATA HDD” steps to install the 2.5-inch pluggable SATA HDD.
2.5-inch Pluggable HDD Backplane
Each server board module supports one 2.5-inch pluggable HDD backplane; two HDD backplanes share the same removal and installation procedure. For your reference, this section provides the steps of removing and installing one 2.5-inch pluggable HDD backplane as an example.
Figure 37 shows the location of a 2.5-inch pluggable HDD backplane on the server chassis:
32 Intel® Server System SR1680MV Service Guide
Figure 37. 2.5-inch Pluggable HDD Backplane Location
Page 53
Note: Before you remove or install the power supply, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the motherboard cage module. To remove the cover, see “Removing the
Server Board Cage Module”.
3. Disconnect all necessary cable connections.
Removing an HDD Backplane
1. Loosen the two securing screws on the backplane.
2. Lift the backplane up from motherboard.
Figure 38. Remove the Screws and Lift the Backplane Up
Installing a 2.5-inch Pluggable SATA HDD Backplane
Reverse the “Removing an HDD Backplane” steps to install the 2.5-inch pluggable SATA HDD backplane.
System Fans
Each I/O board cage module includes three system fans. The six system fans on the server system share the same removal and installation procedures. For your reference, this section provides the steps for replacing one system fan on the right I/O board cage module as an example.
The following figure shows the location of the system fan on the right I/O board cage module:
Intel® Server System SR1680MV Service Guide 33
Page 54
Note: Before you remove or install the power supply, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the left and right I/O board cage modules. To remove the cover, see “Left
and Right I/O Board Cage Modules”.
3. Disconnect all necessary cable connections.
Removing a System Fan
1. Lift the system fan up from the I/O board cage module.
Figure 39. System Fans Location
Figure 40. Lift a System Fan Up from I/O Board Cage Module
34 Intel® Server System SR1680MV Service Guide
Page 55
Installing a System Fan
Reverse the “Removing a System Fan” steps to install the system fan.
Air Duct
Note: Before you remove or install the air duct, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the left and right IO board cage modules. To remove the cover, see “Left
and Right I/O Board Cage Modules”.
3. Disconnect all necessary cable connections.
Removing the IOB Air Duct
1. Lift the air duct up from the I/O board cage module.
Figure 41 shows the air duct located on I/O board.
Intel® Server System SR1680MV Service Guide 35
Figure 41. Lift Air Duct Up
Page 56
Installing Air Ducts
Reverse the “Removing the IOB Air Duct” steps to install the air duct.
PCI-E Cage
The left and right I/O board cage modules each include one PCI-E cage. Two PCI-E cages on the server share the same removal and installation procedures. For your reference, this section provides the steps of removing and installing one PCI-E cage on the right I/O board cage module as an example.
Figure 42 shows the location of the PCI-E cage on the right I/O board cage module:
Figure 42. PCI-E Cage Location
Note: Before you remove or install the PCI-E cage, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the left and right I/O board cage modules. To remove the cover, see “Left
and Right I/O Board Cage Modules”.
3. Disconnect all necessary cable connections.
Removing a PCI-E Cage
1. Lift the PCI cage up from the I/O board cage module along the direction of the arrow.
36 Intel® Server System SR1680MV Service Guide
Page 57
Figure 43. Lifting the PCI Cage from the I/O Board Module
2. Loosen and remove the securing screw.
3. Pull out the expansion card with the slot cover from the PCI-E cage.
Figure 44. Removing the Expansion Card
4. Insert the slot cover to the right position along the arrow.
5. Secure the slot cover to the PCI-E cage with one screw as shown in Figure 45.
Intel® Server System SR1680MV Service Guide 37
Page 58
6. Loosen and remove the two securing screws as shown in Figure 46.
7. Pull the riser card out from the PCI-E cage along the direction of the arrow.
Installing a PCI-E Cage
Figure 45. Securing the Slot Cover
Figure 46. Removing the Riser Card
Reverse the “Removing a PCI-E Cage” steps to install the PCI-E cage.
Daughter Cards (Optional)
There are two optional daughter cards supported by each IO board. The 10 GB IO card and the InfiniBand card share the same removal and installation procedure. For your reference, this section takes the steps of removing and installing 10GB IO card as example.
Figure 47 shows the location of the 10 GB IO card.
38 Intel® Server System SR1680MV Service Guide
Page 59
Figure 47. 10 GB IO Card Location
Figure 48 shows the location of the InfiniBand card.
Figure 48. InfiniBand Card Location
Note: Before you remove or install the 10 GB IO card, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off the server, see “Power Off”.
2. Remove the left and right IO board cage modules. To remove the cover, see “Left
and Right I/O Board Cage Modules”.
3. Disconnect all necessary cable connections.
Removing the IO Expansion Module
1. Separate guide pins of the module from the holes on the IO Board and lift the module upward.
Intel® Server System SR1680MV Service Guide 39
Page 60
Figure 49. Lifting the Module Upward from the IO Board
2. Remove the I/O Expansion module out of the IO board module.
Figure 50. Removing the Module Upward from the IO Board
40 Intel® Server System SR1680MV Service Guide
Page 61
Installing the IO Expansion Module
Reverse the steps in the “Removing the IO Expansion Module”to install the IO Expansion module.
Intel® Server System SR1680MV Service Guide 41
Page 62
42 Intel® Server System SR1680MV Service Guide
Page 63
3 Cable Connections
Connectors and Pin 1 Locations
Figure 51 shows the different locations of the connectors and their pin 1 locations, which can help you connect the cables.
Figure 51. Locations of Connectors and Pin 1 on Server Board
Intel® Server System SR1680MV Service Guide 43
Page 64
Cable Connections
You can get a clear picture on how to connect the cables from the following figures.
Before connecting the cables, you must make sure there are no existing bent pins because they will affect signal transmission. With the Pin 1 location and fool-proof feature, you can link these cables correctly and conveniently. There are two ways for you to judge how to connect the cables:
1. When there is no fool-proof feature on this connector, you should connect the red margin of the cable to the pin 1 location on the connector.
2. When there is a fool-proof feature on the connector, you can connect the cable according to the fool-proof feature.
This section contains figures showing cable locations and descriptions of the connection procedures.
System Fan Cables
System Fan Cables
Figure 52. Locations of Connectors and Pin 1 on I/O Board
Connect the 6-pin system fan cables from the system fans to the corresponding system fan connectors on the I/O board.
44 Intel® Server System SR1680MV Service Guide
Page 65
Figure 53. Connecting the System Fan Cables
Intel® Server System SR1680MV Service Guide 45
Page 66
46 Intel® Server System SR1680MV Service Guide
Page 67
4 Connectors, Jumpers, and LEDs
Connector and Component Locations of Server Board
Figure 54. Connectors and Component Locations of Server Board
1. System Battery (BH1) 2. ICH Functions Jumper (J30)
3. HDD Backplane Connector
5. Server board SATA4 Connector (J29)
7. Processor 1 (CPU 1) 8. DIMM Socket Group (J7, J8, J9,
9. Server board Power Connector4 (J5)
11. Server board IO Connector (J1)
13. Server board Power Connector1 (J2)
15. DIMM Socket Group 2 (J17, J18, J19, J20, J21, J22, J23, J24, J25)
4. SATA Power Connector (J47)
6. Server board SATA3 Connector (J31)
J10, J11, J12, J13, J14, J15)
10. Server board Power Connector3 (J4)
12. Server board Power Connector2 (J3)
14. Processor 2 (CPU 2)
16. MISC Jumper
Intel® Server System SR1680MV Service Guide 47
Page 68
17. Front UID LED 18. Front UID Button
19.Power Button 20.System Health LED
21. Power LED 22. Front USB Ports
23. NIC LED 24. HDD LED
25. Serial Port 26. VGA Port
48 Intel® Server System SR1680MV Service Guide
Page 69
Connector and Component Locations of IO Board
Figure 55. Connectors and Component Locations of IO Boards
Description Location Description Location
Left Right Left Right
1. PCI-E x8 Slots J5 J5 2. IO Board IO Connector
3. System Fan1
Connectors
5. System Fan3
Connectors
7. PCI-E 1
Connectors
9. Rear UID LEDs CR6 CR6 10. Rear UID
J6 J7 4. System Fan2
Connectors
J7 J8 6. PCI-E 2
Connectors
J3 J3 8. IO Board NIC
Connectors
Buttons
J10 J10
J8 J9
J2 J2
J4 J4
SW2 SW2
Intel® Server System SR1680MV Service Guide 49
Page 70
Connector and Component Locations of NIC Board
Figure 56. Connectors and Component Locations of NIC Board
1. Connector 2. Rear NIC2 Port
3. Rear NIC1 Port
50 Intel® Server System SR1680MV Service Guide
Page 71
Connectors and Components of Front Panel
Figure 57. Connectors and Component Locations of Front Panel
1. Front VGA Port 2. Front Serial Port
3. NIC LED 4. Front USB Port
5. System Health LED 6. Power Button
7. Front UID Button 8. UID LED
9. Power LED 10. Front USB Port
11. SATA LED
Intel® Server System SR1680MV Service Guide 51
Page 72
10 GB IO Card (Optional Daughter Card)
Figure 58. Connectors and Components of 10 GB IO Card
1. PCI-E 2 Connector 2. PCI-E 1 Connector
3. 10 GB IO Port1 4. 10 GB IO Port2
52 Intel® Server System SR1680MV Service Guide
Page 73
InfiniBand Card (Optional Daughter Card)
Figure 59. Connectors and Components of InfiniBand Card
1. PCI-E 2 Connector 2. PCI-E 1 Connector
3. InfiniBand CX4 Port
Intel® Server System SR1680MV Service Guide 53
Page 74
Connector and Component Locations of HDD Backplane
Figure 60. Connectors and Components of 2.5-inch Pluggable HDD Backplane
1. HDD 0 Fail LED (CR4) 2. HDD 1 Fail LED (CR2)
3. HDD 1 Active LED (CR1)
5. HDD 0 Active LED (CR3)
7. Golden Fingers (J1)
4. SATA 1 Connector (J3)
6. SATA 0 HDD Connector (J2)
54 Intel® Server System SR1680MV Service Guide
Page 75
Connectors and Component Locations of PDB
Figure 61. Connectors and Component Locations of PDB
1. Power Supply Slot (J1) 2. Power Connector 1 (J5)
3. Power Connector 2 (J4)
5. Power Connector 4 (J2)
4. Power Connector 3 (J3)
The server board involves two system maintenance jumpers. One is MISC jumper, and the other is an ICH functions jumper. Two jumpers are divided into five pin groups (refer to
Figure 62 “Location of MISC Jumper” on page -56 and Figure 63 “Location of ICH Function Jumper” on page -57.
The location of two system maintenance jumpers on the motherboard is shown in the following figure:
Intel® Server System SR1680MV Service Guide 55
Page 76
Figure 62. Location of MISC Jumper
Jumper Function
A Reserved B Clear BMC Password C Reserved D Reserved E Reserved F Reserved G Reserved H Reserved
56 Intel® Server System SR1680MV Service Guide
Page 77
Figure 63. Location of ICH Function Jumper
Jumper Function
A Clear CMOS B Clear Password C Recovery RWH D BIOS Protect E RTC Reset
Intel® Server System SR1680MV Service Guide 57
Page 78
58 Intel® Server System SR1680MV Service Guide
Page 79
5 BIOS Setup and Configuration
This section describes the BIOS Setup Utility options. You can run the BIOS setup with or without an operating system present. Onboard devices are configured with the BIOS Setup utility that is embedded in flash ROM.
The configuration utilities allow you to modify the CMOS RAM and NVRAM. The actual hardware configuration is accomplished by the BIOS POST routines and the BIOS Plug­N-Play auto-configuration manager. The configuration utilities update a checksum for both areas, so potential data corruption is detected by the BIOS before the hardware configuration is saved. If the data is corrupted, the BIOS requests that the user reconfigure the system and reboot.
Note: Because the BIOS code is the most often changed part of the server board design, the
BIOS information described in this section may be a little different compared to the actual BIOS that contained in your server board.
BIOS Setup Utility
This section describes the ROM-resident setup utility that provides the means to configure the platform. The BIOS Setup utility is part of the system BIOS and allows limited control over onboard resources.
The user can disable embedded PCI devices through the setup menus. When these devices are disabled through setup, their resources are freed.
Note: The BIOS options described in this section may or may not be present in pre-production
versions of the system BIOS. This section describes the BIOS utility as it is planned to be at production and is subject to change. Option locations, in a given menu of the BIOS Setup utility as described in this section, may be different from those observed on any one pre-production version of the system BIOS.
The BIOS Setup utility screen is divided into four functional areas.
Table 5. BIOS Setup Utility Screen Descriptions
Functional Area Description
Keyboard Command Bar Located at the bottom of the right screen or as part of the help
screen. This bar displays the keyboard commands supported by the setup utility.
Menu Selection Bar Located at the top of the screen. Displays the various major menu
selections available to the user . The Server Setup utility major menus are: Main Menu, Advanced Menu, Boot Menu, Security Menu, and Exit Menu.
Intel® Server System SR1680MV Service Guide 59
Page 80
Table 5. BIOS Setup Utility Screen Descriptions
Functional Area Description
Options Menu Each Option Menu occupies the left and center sections of the
screen. Each menu contains a set of features. Selecting certain features within a major Option Menu drops you into sub-menus.
Item-Specific Help Screen An item-specific Help screen is located at the upside of the ri ght
side of the screen.
Entering the BIOS Setup Utility
During the BIOS POST operation, the user is prompted to use the Del function key to enter Setup as follows:
Press <F2> to run <Setup>.
Press <F11> to enter BBS POPUP.
A few seconds might pass before Setup is entered. This is the result of POST completing test and initialization functions that must be completed before Setup can be entered. When Setup is entered, the Main Menu options page displays.
Keyboard Command Bar
The right portion of the Setup screen provides a list of commands that are used to navigate through the Setup utility. These commands display at all times.
Each menu page contains a number of configurable options and/or informational fields. Depending on the level of security in affect, configurable options may or may not be changed. If an option cannot be changed due to the security level, its selection field is made inaccessible.
The Keyboard Command Bar supports the following:
Table 6. Keyboard Command Bar Description
Key Option Description
Enter Execute Command The Enter key is used to activate sub-menus when the selected
feature is a sub-menu, or to display a pick list if a selected option has a value field, or to select a sub-field for multi-valued features like time and date. If a pick list is displayed, the Enter key will undo the pick list, and allow another selection in the parent menu.
60 Intel® Server System SR1680MV Service Guide
Page 81
Table 6. Keyboard Command Bar Description
Key Option Description
ESC Exit The ESC key provides a mechanism for backing out of any field.
This key will undo the pressing of the Enter key. When the ESC key is pressed while editing any field or selecting features of a menu, the parent menu is re-entered.
When the ESC key is pressed in any sub-menu, the parent menu is re-entered. When the ESC key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be discarded. If "No" is selected and the Enter key is pressed, or if the ESC key is pressed, the user is returned to where they were before ESC was pressed without affecting any existing settings. If "Yes" is selected and the Enter key is pressed, Setup is exited and the BIOS continues with POST.
Select Item The up arrow is used to select the previous value in a pick list, or
Select Item The down arrow is used to select the next value in a menu item's
Select Menu The left and right arrow keys are used to move between the
Tab Select Field The Tab key is used to move between fields. For example, Tab
- Change Value The minus key on the keypad is used to change the value of the
+ Change Value The plus key on the keypad is used to change the value of the
the previous options in a menu item's option list. The selected item must then be activated by pressing the Enter key.
option list, or a value field's pick list. The selected item must then be activated by pressing the Enter key.
major menu pages. The keys hav e no aff ect if a sub-menu or pick list is displayed.
can be used to move from hours to minutes in the time item in the main menu.
current item to the previous value. This key scrolls through the values in the associated pick list without displaying the full list.
current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list. On 106-key Japanese keyboards, the plus key has a different scan code than the plus key on the other keyboard, but will have the same effect.
F9 Load Optimal Defaults Pressing F9 causes the following to display:
Intel® Server System SR1680MV Service Guide 61
Setup Confirmation Load Optimal Defaults? [OK] [Cancel] If “OK” is selected and the Enter key is pressed, all Setup fields
are set to their default values. If “Cancel” is selected and the Enter key is pressed, or if the ESC key is pressed, the user is returned to where they were before F9 was pressed without affecting any existing field values.
Page 82
Table 6. Keyboard Command Bar Description
Key Option Description
F10 Save and Exit Pressin g F10 causes the following message to display:
Setup Confirmation Save Configuration changes and exit setup? [OK] [Cancel] If “OK” is selected and the Enter key is pressed, all changes are
saved and Setup is exited. If “Cancel” is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned to where they were before F10 was pressed without affecting any existing values.
BIOS Setup Utility Menu
The Setup Utility menu bar displays the five primary menu selections. For detailed information and screenshots of these Setup Utility menus and their related submenus, refer to the following sections.
Note: Settings with * in tables are BIOS Setup defaults of BIOS Setup Utility Menu.
62 Intel® Server System SR1680MV Service Guide
Page 83
Main Menu
Main Advanced Boot Security Exit
Table 7. Main Menu of BIOS Setup Utility
BIOS Setup Utility
System Overview AMIBIOS Version :08.00.15 Build Date :02/16/09 ID :MARBLE VALLEY105 Processor Intel(R) Xeon(R) CPU E5540
@ 2.53 GHz Speed :2533 MHz Count :2 System Memory Size :6144 MB System Time [09:52:34] System Date [Fri 11/14/2008]
Use [ENTER], [TAB], or [SHIFT-TAB] to select a field.
Select Screen
Select Item + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
Menu Fields Settings Description
System time Current Time User [ENTER], [TAB] or [SHIFT-TAB] to select a field.
System date Current date User [ENTER], [TAB] or [SHIFT-TAB] to select a field.
Intel® Server System SR1680MV Service Guide 63
Table 8. Main Menu Fields
Use [+] or [-] to configure system Time.
Use [+] or [-] to configure system Time.
Page 84
Advanced Menu
Table 9. Advanced Menu of BIOS Setup Utility
BIOS Setup Utility
Main
Advanced Settings
WARNING: Setting wrong values in below sections may cause system to malfunction.
CPU Configuration
Memory Configuration
SATA Configuration
Super IO Configuration
USB Configuration
PCI Configuration
IPMI Configuration
Remote Access
Advanced
Configuration
Boot Security Exit
Configure CPU
Select Screen
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
64 Intel® Server System SR1680MV Service Guide
Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
Page 85
Table 10. CPU Configuration Submenu
BIOS Setup Utility
Main Advanced Boot Security Exit
Configure advanced CPU settings Module Version:3F.13
Manufacturer: :Intel Intel® Xeon® CPU :E5540 @ 2.53 GHz CPU Revision :D0 Frequency 2.53 GHz BCLK Speed : 133 MHz Cache L1 : 128 KB Cache L2 : 1024 KB Cache L3 : 8192 KB QPI Frequency [Auto] Hardware Prefetcher [Enabled] Adjacent Cache Line Prefetch [Enabled]
®
Intel
Virtualization Tech [Disab led] Execute-Disable Bit Capacity [Enabled] Active Processor Cores [All]
®
Intel
SpeedStep(tm) tech [Enabled] Intel® C-STA T E tech [Disabled]
V02.61 © Copyright 1985-2009, American Megatrends, Inc.
For UP platforms, leave it enabled. For DP/MP servers, it may use to tune performance to the specific application.
Select Screen
Select Item + - Change Option F1 General Help ESC Exit
Table 11. CPU Configuration Submenu Fields
Menu Fields Settings Comments
Advanced/Configure advanced CPU settings
QPI Frequency Auto *
4.800GT
5.866GT
6.400GT
Hardware Prefetcher Disabled
Enabled*
Intel® Server System SR1680MV Service Guide 65
Transition the links to the specified speed when transitioning the links to full-speed. (if supported by all components).
For UP platforms, leave it enabled. For DP/MP servers, it may use to tune performance to the specific application.
Page 86
Table 11. CPU Configuration Submenu Fields
Menu Fields Settings Comments
Adjacent Cache Line Prefetch
®
Intel
Virtualization Tech Disabled*
Disabled Enabled*
Enabled
Execute-Disable Bit Capability
Disabled Enabled
Active Processor Cores All*
1 2
®
Intel
SpeedStep(tm)
tech
®
C-STATE tech Disabled*
Intel
Disabled Enabled*
Enabled
For UP platforms, leave it enabled. For DP/MP servers, it may use to tune performance to the specific application.
When enabled, a VMM can utilize the additional HW Caps. Provided by Intel
®
Virtualization Tech. Note: A full reset is required to change the setting.
When disabled, force the XD feature flag to always return 0.
Number of cores to enable in each processor package.
Disable: Disable GV3 Enable: Enable GV3
CState: CPU idle is set to C2/C3/C4
66 Intel® Server System SR1680MV Service Guide
Page 87
SATA Configuration Submenu
Table 12. SATA Configuration Submenu1
BIOS Setup Utility
Main Advanced Boot Security Exit
SATA Configuration SATA Configuration
Primary IDE Master
Primary IDE Slave
Secondary IDE Master
Hard Disk Write Protect
IDE Detect Time Out (Sec)
:[Compatible] Configure the IDE device(s). :[Not
Detected] :[Not
Detected] :[Not
Detected]
[Disabled] [35]
NOTE1: As Compatible only support IDE mode,
“Configure SATA AS” will be hidden when “SATA Configuration” is compatible.
Select Screen
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
Intel® Server System SR1680MV Service Guide 67
Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
Page 88
Table 13. SATA Configuration Submenu2
BIOS Setup Utility
Main Advanced Boot Security Exit
SATA Configuration [Enhanced] Configure SATA AS
Primary IDE Master
Primary IDE Slave
Secondary IDE Master
Secondary IDE Slave
Hard Disk Write Protect
IDE Detect Time Out (Sec)
[IDE] Configure the IDE device(s). :[Not
Detected] :[Not
Detected] :[Not
Detected] :[Not
Detected]
[Disabled] [35]
Options Disabled Compatible Enhanced
Select Screen
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
68 Intel® Server System SR1680MV Service Guide
Select Item + - Change Field Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
Page 89
Table 14. SATA Configuration Submenu3
BIOS Setup Utility
Main Advanced Boot Security Exit
Configure SATA AS
SATA PORT 1
Hot Plug
SATA PORT 2
SATA PORT 3
SATA PORT 4
Hard Disk Write Protect IDE Detect Time Out (Sec) ATA(PI) 80Pin Cable
Detection
[RAID] Configure the IDE device(s). :[Not
Detected] :[Not
Detected] :[Not
Detected] :[Not
Detected] [Disabled]
[Disabled] [35] [Host &
Device]
Select Screen
Select Item + - Change Field Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
Intel® Server System SR1680MV Service Guide 69
Page 90
Table 15. SATA Configuration Submenu4
BIOS Setup Utility
Main Advanced Boot Security Exit
SATA Configuration [Enhanced] Configure SATA AS
AHCI PORT1
AHCI PORT2
AHCI PORT3
AHCI PORT4
Hot Plug
Hard Disk Write Protect
IDE Detect Time Out (Sec)
[AHCI] Configure the IDE device(s). :[Not
Detected] :[Not
Detected] :[Not
Detected] :[Not
Detected] [Disabled]
[Disabled] [35]
Select Screen
Select Item + - Change Field Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
70 Intel® Server System SR1680MV Service Guide
Page 91
Table 16. SATA Configuration Submenu Fields
Menu Fields Settings Comments
SATA Configuration
SATA Configuration Disabled
Compatible* Enhanced
Configure SATA as IDE*
RAID AHCI
Hot Plug Enable
Disabled*
Hard Disk Write Protect Disabled*
Enable
IDE Detect Time Out (Sec)
0 5 10 15 20 25 30 35*
Options Disabled Compatible Enhanced
Options IDE RAID AHCI
Options Enable Disabled
Disable/Enable device write protection. This will effective only if device is accessed through BIOS.
Select the time out value for detecting ATA/ATAPI device(s).
Intel® Server System SR1680MV Service Guide 71
Page 92
Table 17. Primary/Secondary IDE Master/Slave
BIOS Setup Utility
Main Advanced Boot Security Exit
Primary IDE Master
Device
Type Drive Write Cache Block (Multi-Sector Transfer) LBA/Large Mode PIO Mode DMA Mode[Auto] S.M.A.R.T: 32Bit Data Transfer
:[Not Detected]
:[Auto] :[Disabled] :[Auto] :[Auto] :[Auto] :[Auto] :[Enabled]
Select Screen
Select Item + - Change Option Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
V02.67 © Copyright 1985-2009, American Megatrends, Inc.
72 Intel® Server System SR1680MV Service Guide
Page 93
Table 18. Primary/Secondary IDE Master/Slave Submenu Field
Menu Fields Settings Comments
Advanced/Primary IDE Master
Type Not Installed
Auto* CD/DVD ARMD
Drive Write Cache Disabled*
Enabled
LBA/Large Mode Disabled*
Auto
Block(Multi-Sector Transfer)
PIO Mode Auto
Disabled* Auto
0 1 2 3 4
Select the type of device Connected to the system.
Enabled: Drive Write Cache feature to be enabled to Improve performance.
Disabled: Drive Write Cache feature disabled to avoid the Possibility of data loss due to a power failure.
Disabled: Disables LBA Mode. Auto: Enables LBA Mode if the device supports it and the
device is not already formatted with LBA Mode disabled. Disabled: The Data transfer from and to the device occurs
one sector at a time. Auto: The Data transfer from and to the device Occurs
multiple sectors at a time if the device supports it. Select PIO Mode.
DMA Mode Auto Select DMA Mode.
S.M.A.R.T Auto*
Disabled Enables
32 Bit Data Transfer D isabled*
Enabled
Intel® Server System SR1680MV Service Guide 73
Auto: Auto detected. S.M.A.R.T. stands for Self-Monitoring, Analysis and
Reporting Technology.
Enable/Disable 32-bit Data Transfer.
Page 94
Super IO Chipset Submenu
Table 19. Super IO Chipset Submenu
BIOS Setup Utility
Main
Configure PILOT Super IO Chipset Serial Port Address [3F8/IRQ4] Configure Super IO Chipset PILOT
Advanced
Boot Security Exit
Select Screen
Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
V02.61 © Copyright 1985-2006, American Megatrends, Inc.
74 Intel® Server System SR1680MV Service Guide
Page 95
Table 20. SATA Configuration Submenu Fields
Menu Fields Settings Description
Advanced/Super IO Configuration
Serial Port Address Disabled
3F8/IRQ4 2F8/IRQ3 3F8/IRQ4 2F8/IRQ3
Allows BIOS to select Serial Port1 Base Address.
Intel® Server System SR1680MV Service Guide 75
Page 96
USB Configuration Submenu
Table 21. USB Configuration Submenu
BIOS Setup Utility
Main
USB Configuration Module Version - 2.24.3-13.4
USB Devices Enabled 2 Keyboards, 3 Mice, 1 Hub, 2 Drives Legacy USB Support [Enabled] USB 2.0 Controller mode [HiSpeed] BIOS EHCI Hand-Off [Enabled] Hotplug USB FDD Support [Auto]
Advanced
USB Mass Storage Device
Configuration
BootSecurity Exit
Configure the USB support.
Select Screen
Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
V02.61 © Copyright 1985-2006, American Megatrends, Inc.
Table 22. USB Configuration Submenu Fields
Menu Fields Settings Description
Advanced/USB Configuration
Legacy USB Support Disabled
Enabled* Auto
76 Intel® Server System SR1680MV Service Guide
Enables support for legacy USB. AUTO option disables legacy support if no USB devices are connected.
Page 97
Table 22. USB Configuration Submenu Fields
Menu Fields Settings Description
USB 2.0 Controller mode FullSpeed
HiSpeed*
BIOS EHCI Hand-Off Disabled
Enabled*
Hotplug USB FDD Support
Disabled Enabled Auto*
Configures the USB 2.0 controller in HiSpeed (480 Mbps) or FullSpeed (12Mbps)
This is a workaround for operating systems without EHCI hand-off support. The EHCI ownership change should claim by EHCI driver.
A dummy FDD device is created that will be associated with the hotplugged FDD later. Auto option creates this dummy device only if there is no FDD present.
Intel® Server System SR1680MV Service Guide 77
Page 98
USB Mass Storage Device Configuration Submenu
Table 23. USB Mass Storage Device Configuration Submenu
BIOS Setup Utility
Main
USB Mass Device Storage Configuration USB Mass Storage Reset Delay [20 Sec]
Device #1 AMI Virtual CDROM Emulation Type [Auto] Device #1 AMI Virtual Floppy #N Emulation Type [Auto]
Advanced
Boot Security Exit
Configure the USB Mass Storage Device Classes.
Select Screen
Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
V02.61 © Copyright 1985-2006, American Megatrends, Inc.
78 Intel® Server System SR1680MV Service Guide
Page 99
Table 24. USB Mass Storage Device Configuration Submenu Fields
Menu Fields Settings Description
Advanced/USB Configuration
USB Mass Storage Reset Delay
Emulation Type Auto*
10 Sec 20 Sec* 30 Sec 40 Sec
Floppy Forced FDD Hard Disk CDROM
Number of seconds POST waits for the USB mass storage device after start unit command.
If Auto, USB devices less than 530 MB will be emulated as Floppy and remaining as hard drive. Forced FDD option can be used to force a HDD-formatted drive to boot as FDD (for example, a zip drive).
Intel® Server System SR1680MV Service Guide 79
Page 100
PCI Express* Configuration Submenu
Table 25. PCI Express* Configuration Submenu
BIOS Setup Utility
Main
PCI Express Configuration Active State Power-Management [Disabled] Configure PCI Express* support.
Advanced
BootSecurity Exit
Select Screen
Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
V02.61 © Copyright 1985-2006, American Megatrends, Inc.
Table 26. PCI Express* Configuration Submenu Fields
Menu Fields Settings Description
Advanced/USB Configuration
Active State Power­Management
80 Intel® Server System SR1680MV Service Guide
Disabled* Enabled
Enable/Disable PCI Express* L0s and L1 link power states.
Loading...