Intel SR1630GP - Server System - 0 MB RAM, SR1630HGP Service Manual

Intel® Server System SR1630GP / SR1630HGP Service Guide

A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Disclaimer
®
Information in this document is provided in connection with Intel estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability , or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult v endor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. All Rights Reserved
ii Intel® Server System SR1630GP / SR1630HGP Service Guide
products. No license, express or implied, by

Safety Information

Important Safety Instructions

Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Deployment Toolkit CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.

Wichtige Sicherheitshinweise

Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel oder unter
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit CD

Consignes de sécurité

Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel vous sur le site
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit CD ou bien rendez-

Instrucciones de seguridad importantes

Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel
support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit CD y/o en http://support.intel.com/
Intel® Server System SR1630GP / SR1630HGP Service Guide iii
iv Intel® Server System SR1630GP / SR1630HGP Service Guide

Warnings

Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1630GP / SR1630HGP Service Guide v
vi Intel® Server System SR1630GP / SR1630HGP Service Guide

Preface

About this Manual

Thank you for purchasing and using the Intel® Server System SR1630GP/SR1630HGP.
This manual is written for system technicians responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step-by-step instructions on how to add and replace components on the server system. For the latest version of this manual, see http://support.intel.com/support/
motherboards/server/S3420GP/.

Manual Organization

Chapter 1 provides an overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.
Chapter 2 provides instructions on using the utilities shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, perform a BIOS update, and reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Intel Technical Product Specification.
Chapter 3 provides instructions on adding and replacing components. Use this chapter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
At the back of this manual, you will find technical specifications, troubleshooting tips, regulatory information, complete safety information, “getting help” information, and the warranty.
®
Server Board S3420GP
Intel® Server System SR1630GP/SR1630HGP Service Guide vii

Product Contents

The Intel® Server System SR1630GP/SR1630HGP ships with the Intel® Server Board S3420GPLC.
There are two versions of this server system: the Intel® Server System SR1630GP and the
®
Server System SR1630HGP. The contents of each server system are listed below.
Intel

Intel® Server System SR1630GP Contents

Your Int el® Server System SR1630GP ships with the following items:
One Intel
One 350-W power supply module, installed in the server system
Two system blower fans, with attached cables, installed in the server system:
One passive heat sink, mounted in the HDD0 position, next to the blower fans in the
server system
®
Server Board S3420GPLC installed in the server system
One hard disk drive 0 bracket, in the server system product box
One hard disk drive 1 bracket, installed in the server system
One slimline optical drive installation kit, in the server system product box
One PCI-E x 8 low profile riser card with supporting bracket, installed in the server
system.
Screws:
6-32# screws for attaching the slimline optical drive to the chassis. — 6-32# screws for attaching hard disk drives to the hard disk drive brackets and
attaching hard disk drive 0 bracket to the chassis.
Four M2 screws for attaching the brackets to the slimline optical drive
Rack handles, in the server system product box
Standard front panel, installed in the server system
One rail kit, in a separate box
Cables:
Two SATA cables, installed in the server system — One front panel USB cable, installed in the server system — One front panel cable, installed in the server system
Documentation, drivers, and installation CD
viii Intel® Server System SR1630GP/SR1630HGP Service Guide

Intel® Server System SR1630HGP Contents

Your Intel® Server System SR1630HGP ships with the following items:
One Intel
One 350-W power supply module, installed in the server system
Two system blower fans, with attached cables, installed in the server system:
One passive heat sink, mounted behind the hard drives, next to the blower fans in the
server system
Three hot-swap hard disk drive carriers, installed in the server system.
One air baffle in the server system product box.
One slimline optical drive installation kit, in the server system product box.
One PCI-E x 8 low profile riser card with supporting bracket, installed in the server
system.
Screws:
®
Server Board S3420GPLC installed in the server system
One M2 screw for attaching the bracket to slim optical drive. — One M3 screw for attaching the slim optical drive to the server system. — One 6-32# screw for attaching the air baffle to the serve system.
Rack handles, in the server system product box
Standard front panel, installed in the server system
Standard HDD backplane, installed in the server system.
One rail kit, in a separate box
Cables:
Three SATA cables, installed in the server system — One front panel USB cable, installed in the server system — One front panel cable, installed in the server system — One SPGIO cable, installed in the server system.
Documentation, drivers, and installation CD
Intel® Server System SR1630GP/SR1630HGP Service Guide ix
Server System References
If you need more information about this product or information about the accessories that you can use with this server chassis, use the following resources.
For this Information or
Software
Technical information about the server chassis, including sub-system overviews and mechanical drawings
If you just received this product and need to install it
Accessories or other Intel server products
Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product
Processors that have been tested with this product
Use this Document or Software
Intel® Server System SR1630GP/SR1630HGP Technical Product Specification
http://support.intel.com/support/motherboards/server/S3420GP/
Intel® Server Board S3420GP Technical Product Specification
http://support.intel.com/support/motherboards/server/S3420GP/
Intel® Server System SR1630GP/SR1630HGP Quick Start User's Guide in the product box.
Spares/Parts List & Configuration Guide
This is available from your Intel field representative or on the Server Configurator Tool at:
http://www.intel.com/support/motherboards/server/s3420gp/ howto.htm
For the Tested Hardware Operating Systems List, you can go to the
®
Intel
Server Configurator Tool:
http://serverconfigurator.intel.com/default.aspx
Supported processors can be found at:
http://support.intel.com/support/motherboards/server/S3420GP/
DIMMs that have been tested with this product
T o make sure y our system falls within the allowed power budget
For software to manage your Intel
For drivers Driver (for an extensive list of drivers available)
For firmware and BIOS updates
x Intel® Server System SR1630GP/SR1630HGP Service Guide
®
server
Supported memory can be found at:
http://support.intel.com/support/motherboards/server/S3420GP/
Power Budget Tool
http://support.intel.com/support/motherboards/server/S3420GP/
Intel® System Management
http://support.intel.com/support/motherboards/server/S3420GP/
Operating System Driver (for operating system driv er s)
http://support.intel.com/support/motherboards/server/S3420GP/
Firmware can be found at:
http://support.intel.com/support/motherboards/server/S3420GP/
For this Information or
Software
For diagnostics test software
Use this Document or Software
Diagnostics
http://support.intel.com/support/motherboards/server/S3420GP/
Intel® Server System SR1630GP/SR1630HGP Service Guide xi
xii Intel® Server System SR1630GP/SR1630HGP Service Guide

Table of Contents

Safety Information .....................................................................................................iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Warnings ................................................................................................................................v
Preface .......................................................................................................................vii
About this Manual ................................................................................................................ vii
Manual Organization ............................................................................................................vii
Product Contents .................................................................................................................viii
Server System References ....................................................................................................x
Chapter 1: Server System Features ..........................................................................1
Chassis Component Identification .........................................................................................5
Server Board Connectors / Components .............................................................................13
Configuration Jumpers .........................................................................................................15
Hardware Requirements ...................................................................................................... 17
®
Intel
Server System SR1630GP Contents ................................................................viii
®
Server System SR1630HGP Contents ...............................................................ix
Intel
System Front Panel (SR1630GP) .................................................................................5
System Front Panel (SR1630HGP) ...............................................................................7
System Rear ..................................................................................................................8
Peripheral Devices (SR1630GP) ...................................................................................9
Peripheral Devices (SR1630HGP) ................................................................................9
Hard Disk Drives ............................................................................................................9
Slimline Optical Drive Carrier ......................................................................................10
Internal Components (SR1630GP) ..............................................................................11
Internal Components (SR1630HGP) ...........................................................................12
Processor ....................................................................................................................17
Memory ........................................................................................................................17
Chapter 2: Server Utilities ........................................................................................19
Using the BIOS Setup Utility ................................................................................................19
Starting Setup ..............................................................................................................19
If You Cannot Access Setup ........................................................................................19
Setup Menus ...............................................................................................................19
Upgrading the BIOS .............................................................................................................21
Preparing for the Upgrade ...........................................................................................21
Upgrading the BIOS ....................................................................................................22
Intel® Server System SR1630GP / SR1630HGP Service Guide xiii
Recovering the BIOS ..................................................................................................22
Recovering the BIOS ...........................................................................................................22
Clearing the Password ........................................................................................................23
Clearing the CMOS ................................................................................... ........... .......24
Updating the Integrated BMC ......................................................................................25
Chapter 3: Hardware Installations and Upgrades ..................................................27
Before You Begin ................................................................................................................27
Tools and Supplies Needed ........................................................................................27
System References .....................................................................................................27
Removing and Installing the Front Bezel .............................................................................28
Removing the Front Bezel ...........................................................................................28
Installing the Front Bezel .............................................................................................29
Removing and Installing the Server Cover ..........................................................................30
Removing the Server System Cover ...........................................................................30
Installing the Server System Cover .............................................................................32
Removing and Installing the Processor Air Duct .................................................................33
Removing the Processor Air Duct ............................................................................... 33
Installing the Processor Air Duct ................................................................................. 35
Installing and Removing Memory ........................................................................................ 36
Installing DIMMs ..........................................................................................................37
Removing DIMMs ........................................................................................................37
Replacing the Processor .....................................................................................................39
Removing the Heat Sink and Processor ..................................................................... 39
Installing the Processor ...............................................................................................40
Installing the Heat Sink ...............................................................................................43
Installing and Removing a Hard Drive (SR1630GP) ...........................................................44
Installing a Hard Disk Drive (SR1630GP) ...................................................................44
Removing a Hard Disk Drive (SR1630GP) .................................................................48
Installing and Removing a Hot-Swap SATA Drive (SR1630HGP) ......................................51
Installing a Hot-Swap SATA Drive (SR1630HGP) ......................................................51
Removing a Hot-Swap SATA Drive (SR1630HGP) ....................................................53
Installing or Removing a Slimline Optical Drive (SR1630GP) .............................................54
Installing a Slimline Optical Drive ................................................................................54
Removing a Slimline Optical Drive ..............................................................................56
Installing or Removing a Slimline Optical Drive (SR1630HGP) .......................................... 58
Installing a Slimline Optical Drive (SR1630HGP) ........................................................58
Removing a Slimline Optical Drive (SR1630HGP) ......................................................59
Installing and Removing the PCIe* Riser Assembly ............................................................61
Removing the PCIe* Riser Assembly ..........................................................................61
Installing the PCIe* Riser Assembly ............................................................................62
Installing or Replacing a PCIe* Riser Card .........................................................................63
Removing a PCIe* Riser Card ....................................................................................63
Installing a PCIe* Riser Card ......................................................................................64
xiv Intel® Server System SR1630GP / SR1630HGP Service Guide
Installing and Removing a PCI Add-in Card ........................................................................65
Installing a PCI Add-in Card ........................................................................................65
Removing a PCI Add-in Card ......................................................................................66
Replacing the Server Board .................................................................................................68
Removing the Server Board ........................................................................................68
Installing the Server Board ..........................................................................................70
Replacing the CMOS Battery ...............................................................................................72
Replacing the Power Supply (SR1630GP) ..........................................................................74
Replacing the Power Supply (SR1630HGP) .......................................................................79
Replacing the Front Panel Board (SR1630GP) ...................................................................81
Replacing the Front Panel Board (SR1630HGP) ................................................................83
Replacing a System Fan (SR1630GP) ................................................................................87
Replacing the System Blower Fans (SR1630GP) .......................................................87
Replacing a System Fan (SR1630HGP) .............................................................................91
Replacing the System Blower Fans (SR1630HGP) ....................................................91
Installing and Removing the Rack Handles .........................................................................93
Installing the Rack Handles .........................................................................................93
Removing the Rack Handles .......................................................................................95
Appendix A: Technical Reference ..........................................................................97
Cable Routing ......................................................................................................................97
Power Cable Routing (SR1630GP) .............................................................................98
Data Cable Routing (SR1630HGP) .............................................................................99
Cable Routing (SR1630HGP) ....................................................................................100
350-W Single Power Supply Input Voltages ......................................................................101
350-W Single Power Supply Output Voltages ...................................................................101
System Environmental Specifications ................................................................................102
Appendix B: Troubleshooting ...............................................................................103
Resetting the System .........................................................................................................103
Problems following Initial System Installation ....................................................................104
First Steps Checklist ..................................................................................................104
Hardware Diagnostic Testing .............................................................................................105
Verifying Proper Operation of Key System Lights .....................................................105
Confirming Loading of the Operating System ............................................................105
Specific Problems and Corrective Actions .........................................................................105
Power Light Does Not Light .......................................................................................106
No Characters Appear on Screen .............................................................................106
Characters Are Distorted or Incorrect ........................................................................107
System Cooling Fans Do Not Rotate Properly ..........................................................107
Drive Activity Light Does Not Light ............................................................................108
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light .............................108
Cannot Connect to a Server ......................................................................................108
Problems with Network ..............................................................................................109
System Boots when Installing PCI Card ....................................................................110
Intel® Server System SR1630GP / SR1630HGP Service Guide xv
Problems with Newly Installed Application Software .................................................110
Problems with Application Software that Ran Correctly Earlier ................................110
Devices are not Recognized under Device Manager (Microsoft Windows* Operating Sys-
tem) ............................................................................................................... 111
Hard Drive(s) are not Recognized .............................................................................111
Bootable CD-ROM Disk Is Not Detected ..................................................................111
LED Information ........................................................................................................112
BIOS POST Beep Codes .......................................................................................... 112
Appendix C: Installation/Assembly Safety Instructions .....................................113
English ............................................................................................................................... 113
Deutsch .............................................................................................................................115
Français ............................................................................................................................. 117
Español ............................................................................................................................. 120
Italiano ............................................................................................................................... 123
Appendix D: Safety Information ............................................................................125
English ............................................................................................................................... 125
Server Safety Information .........................................................................................125
Safety Warnings and Cautions ..................................................................................125
Intended Application Uses ........................................................................................ 126
Site Selection ............................................................................................................126
Equipment Handling Practices ..................................................................................126
Power and Electrical Warnings .................................................................................127
Access Warnings ......................................................................................................127
Electrostatic Discharge (ESD) ...................................................................................128
Other Hazards ...........................................................................................................128
Deutsch .............................................................................................................................129
Sicherheitshinweise für den Server ...........................................................................129
Sicherheitshinweise und Vorsichtsmaßnahmen .......................................................130
Zielbenutzer der Anwendung ....................................................................................130
Standortauswahl .......................................................................................................131
Handhabung von Geräten .........................................................................................131
Warnungen zu Netzspannung und Elektrizität ..........................................................132
Warnhinweise für den Systemzugang .......................................................................132
Elektrostatische Entladungen (ESD) ......................................................................... 133
Andere Gefahren .......................................................................................................134
Français .............................................................................................................................135
Consignes de sécurité sur le serveur ........................................................................135
Sécurité: avertissements et mises en garde .............................................................135
Domaines d’utilisation prévus ...................................................................................136
Sélection d’un emplacement ..................................................................................... 136
Pratiques de manipulation de l’équipement ..............................................................137
Alimentation et avertissements en matière d’électricité ............................................ 138
Avertissements sur l’accès au système ....................................................................138
xvi Intel® Server System SR1630GP / SR1630HGP Service Guide
Décharges électrostatiques (ESD) ............................................................................139
Autres risques ............................................................................................................139
Español ..............................................................................................................................140
Información de seguridad del servidor ......................................................................140
Advertencias y precauciones sobre seguridad ..........................................................140
Aplicaciones y usos previstos ....................................................................................141
Selección de la ubicación ..........................................................................................142
Manipulación del equipo ............................................................................................142
Advertencias de alimentación y eléctricas .................................................................142
Advertencias el acceso al sistema ............................................................................143
Descarga electrostática (ESD) ..................................................................................144
Otros peligros ............................................................................................................144
Appendix E: Regulatory and Compliance Information .......................................153
Product Regulatory Compliance ........................................................................................153
Product Safety Compliance .......................................................................................153
Product EMC Compliance - Class A Compliance ......................................................154
Product Ecology Requirements .................................................................................155
Component Regulatory Requirements Needed to Support System Level Certifications .
156
Certifications / Registrations / Declarations ...............................................................157
Product Regulatory Compliance Markings ................................................................158
Electromagnetic Compatibility Notices ..............................................................................163
FCC Verification Statement (USA) ............................................................................163
Industry Canada (ICES-003) .....................................................................................164
Europe (CE Declaration of Conformity) .....................................................................164
VCCI (Japan) .............................................................................................................164
BSMI (Taiwan) ...........................................................................................................165
Korean Compliance (RRL) ........................................................................................165
End-of-Life / Product Recycling .........................................................................................165
Appendix F: Warranty ............................................................................................167
Limited Warranty for Intel® Chassis Subassembly Products ............................................. 167
Appendix G: Getting Help ......................................................................................171
World Wide Web ................................................................................................................171
Telephone ..........................................................................................................................171
Intel® Server System SR1630GP / SR1630HGP Service Guide xvii
xviii Intel® Server System SR1630GP / SR1630HGP Service Guide

List of Figures

Figure 1. Intel® Server System SR1630GP .............................................................................. 1
Figure 2. Intel
Figure 3. Front Controls and LEDs (SR1630GP)...................................................................... 5
Figure 4. Front Controls and LEDs (SR1630HGP) ................................................................... 7
Figure 5. Back Panel Connectors.............................................................................................. 8
Figure 6. System Components (SR1630GP).......................................................................... 11
Figure 7. System Components (SR1630HGP)........................................................................ 12
Figure 8. S3420GP Connector and Component Locations..................................................... 14
Figure 9. Configuration Jumper Descriptions.......................................................................... 16
Figure 10. BIOS Recovery Jumper ......................................................................................... 23
Figure 11. Password Recovery Jumper.................................................................................. 24
Figure 12. CMOS Recovery Jumper....................................................................................... 25
Figure 13. BMC Force Update Jumper ................................................................................... 25
Figure 14. Removing the Front Bezel...................................................................................... 28
Figure 15. Installing the Front Bezel........................................................................................ 29
Figure 16. Removing the Server System Cover (SR1630GP)................................................ 30
Figure 17. Removing the Server System Cover (SR1630HGP).............................................. 31
Figure 18. Installing the Server System Cover (SR1630GP).................................................. 32
Figure 19. Installing the Server System Cover (SR1630HGP)................................................ 33
Figure 20. Removing the Processor Air Duct (SR1630GP) .................................................... 34
Figure 21. Removing the Processor Air Duct (SR1630HGP).................................................. 34
Figure 22. Installing the Processor Air Duct (SR1630GP) ...................................................... 35
Figure 23. Installing the Processor Air Duct (SR1630HGP).................................................... 36
Figure 24. Installing the Memory............................................................................................. 37
Figure 25. Lifting the Processor Socket Handle...................................................................... 40
Figure 26. Opening the Load Plate ......................................................................................... 41
Figure 27. Removing the Shipping Cover ............................................................................... 41
Figure 28. Installing the Processor.......................................................................................... 42
Figure 29. Removing the Protective Socket Cover ................................................................. 42
Figure 30. Installing the Heat Sink .......................................................................................... 43
Figure 31. Locating Drive Positions (SR1630GP)................................................................... 45
Figure 32. Removing Drive Carrier from the Server System (SR1630GP)............................. 45
Figure 33. Installing Drive into Drive Carrier (SR1630GP)...................................................... 46
Figure 34. Install Drive Assembly into the Server System (SR1630GP)................................. 46
Figure 35. Connecting Hard Drive Power and Data Cables (SR1630GP).............................. 48
Figure 36. Removing Drive Carrier from the Server System (SR1630GP)............................. 49
Figure 37. Locating Drive Positions (SR1630HGP) ................................................................ 51
Figure 38. Removing the Drive Carrier (SR1630HGP)........................................................... 52
Figure 39. Installing Drive into Drive Carrier (SR1630HGP)................................................... 52
Figure 40. Install Drive Assembly into the Server System (SR1630HGP).............................. 53
Figure 41. Removing the Knock-out from the Sheet Metal Panel........................................... 55
Figure 42. Attaching the Optical Drive to the Brackets............................................................ 55
®
Server System SR1630HGP............................................................................ 2
Intel® Server System SR1630GP / SR1630HGP Service Guide xix
Figure 43. Installing the Optical Drive into the System........................................................... 56
Figure 44. Removing the Optical Drive from the Server System............................................ 57
Figure 45. Removing the Optical Drive Brackets.................................................................... 57
Figure 46. Attaching the Optical Drive to the Attachment Bracket.......................................... 58
Figure 47. Installing the Optical Drive into the System........................................................... 59
Figure 48. Removing the Optical Drive from the System........................................................ 60
Figure 49. Removing the Optical Drive from the Attachment Bracket .................................... 60
Figure 50. Removing PCIe* Riser Assembly from the Server System ................................... 61
Figure 51. Installing PCIe* Riser Assembly into the Server System....................................... 62
Figure 52. Removing Riser Card from Riser Assembly.......................................................... 63
Figure 53. Installing Riser Card onto Riser Assembly ............................................................ 64
Figure 54. Installing an Add-In Card....................................................................................... 66
Figure 55. Removing a Full Height Add-In Card..................................................................... 67
Figure 56. Removing the Server Board .................................................................................. 69
Figure 57. Installing the Server Board .................................................................................... 71
Figure 58. Replacing the CMOS Battery................................................................................. 73
Figure 59. Disconnecting Power Cables (SR1630GP)........................................................... 75
Figure 60. Removing Power Supply from the Server System (SR1630GP)........................... 76
Figure 61. Installing Power Supply Module into the Server System (SR1630GP).................. 77
Figure 62. Connecting Power Cables (SR1630GP)................................................................ 78
Figure 63. Removing Power Supply from the Server System (SR1630HGP)........................ 79
Figure 64. Installing Power Supply Module into the Server System (SR1630HGP)............... 80
Figure 65. Removing Front Panel Board from the Server System (SR1630GP).................... 81
Figure 66. Installing Front Panel Board into the Server System (SR1630GP) ....................... 82
Figure 67. Removing Front Panel Board from the Server System (SR1630HGP)................. 83
Figure 68. Removing Light Pipes from the Front Panel Board (SR1630HGP)....................... 84
Figure 69. Installing Front Panel Board into the Server System (SR1630HGP)..................... 85
Figure 70. Installing Light Pipes on the Front Panel Board (SR1630HGP)............................ 86
Figure 71. Disconnecting System Blower Fans (SR1630GP)................................................. 87
Figure 72. Removing Bracket and System Blower Fans from Server System (SR1630GP).. 88
Figure 73. Removing Fan from Fan Bracket (SR1630GP)..................................................... 89
Figure 74. Connecting System Blower Fans (SR1630GP)..................................................... 90
Figure 75. Removing Fan from the Server System (SR1630HGP) ........................................ 92
Figure 76. Installing Fan into the Server System (SR1630HGP)............................................ 93
Figure 77. Installing the Rack Handle..................................................................................... 94
Figure 78. Removing the Rack Handle................................................................................... 95
Figure 79. Power Cable Routing (SR1630GP)....................................................................... 98
Figure 80. Data Cable Routing (SR1630HGP)....................................................................... 99
Figure 81. Cable Routing (SR1630HGP).............................................................................. 100
xx Intel® Server System SR1630GP / SR1630HGP Service Guide

List of Tables

Table 1. Intel® Server System SR1630GP / SR1630HGP Feature Summary ..........................3
Table 2. Intel
Table 3. Intel® Server System SR1630HGP Control Panel LED Functions .............................7
Table 4. NIC LED Descriptions .................................................................................................8
Table 5. Channel Slot Configuration .......................................................................................17
Table 6. Setup Menu Key Use ................................................................................................20
Table 7. Power Supply Output Capability ..............................................................................101
Table 8. System Environmental Specifications .....................................................................102
Table 9. Resetting the System ..............................................................................................103
Table 10. LED Information ....................................................................................................112
Table 11. POST Error Beep Codes .......................................................................................112
Table 12. .Product Regulatory Compliance Markings ...........................................................158
®
Server System SR1630GP Control Panel LED Functions ................................5
Intel® Server System SR1630GP / SR1630HGP Service Guide xxi
xxii Intel® Server System SR1630GP / SR1630HGP Service Guide

1 Server System Features

This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system.
Figure 1. Intel® Server System SR1630GP
Note: Figure 1 is shown with an optional optical drive installed.
Intel® Server System SR1630GP / SR1630HGP Service Guide 1
Figure 2. Intel® Server System SR1630HGP
Note: Figure 2 is shown with an optional optical drive installed.
2 Intel® Server System SR1630GP / SR1630HGP Service Guide
Table 1 summarizes the features of the server system.
Table 1. Intel® Server System SR1630GP / SR1630HGP Feature Summary
Feature Description
Dimensions (SR1630GP) 1.70 inches high (4.30 centimet ers)
16.93 inches wide (43.00 centimeters)
20 inches deep (50.80 centimeters)
22 pounds (9.979 kilograms)
Dimensions (Sr1630HGP) 1.69 inches high (4.29 centimet ers)
16.9 inches wide (43.00 centimeters)
25.5 inches deep (64.8 centim et ers)
23 pounds (10.43 kilograms)
Server Board Intel® Server Board S3420GPLC Processor Supports for one Intel® Xeon® 3400 Series Processor in FC-LGA
1156 socket package.
2.5 GT/s point-to-point DMI interface to PCH
LGA 1156 pin socket
Memory Two memory channels with support for 1066 / 1333 Unbuffered
Chipset Support for Intel® Ibexpeak Platform Controller Hub (PCH)
Peripherals Slimline bay for slimline SAT A optical drive.
I/O Control External connections:
(UDIMM) or 800/1066/1033 MHz Registered (RDIMM) DDR3. Up to two UDIMMs or three RDIMMs per channel. 32 GB maximum
with x8 ECC RDIMM (2 Gb DRAM) and 16 GB maximum with x8 ECC UDIMM.
ServerEngines* LLC Pilot II BMC controller (Integrated BMC)
One PCI Express* x8 add-in card slot (Gen 2).
DB-15 video connectors
DB-9 serial Port A connector
Four USB 2.0 connectors
One USB 2.0 connector (front)
Expansion Capabilities (optional accessory
required) Fans Supports two system fans. Video On-board ServerEngines* LLC Pilot II BMC Controller
One low-profile riser slot supporting one low-profile half-length PCI Express* 2.0 x8 add-in card.
Integrated 2D Video Controller with 8 MB video memory
64 MB DDR2 667 MHz memory
Intel® Server System SR1630GP / SR1630HGP Service Guide 3
Table 1. Intel® Server System SR1630GP / SR1630HGP Feature Summary
Feature Description
LAN One Gigabit Ethernet device 82574L connect to PCI-E x1
interfaces on the PCH
One Gigabit Ethernet PHY 82578DM connected to PCH
through PCI-E x1 interface
Hard Drives SATA support, 3 Gb/s: capable of supporting up to two drives
Peripherals Slimline bay for SATA optical drive (optional). Front panel Standard front panel Power Supply One 350-watt power supply module. System Management On-board LLC Pilot II Controller (iBMC)
(SR1630GP) or three drives (SR1630HGP).
Integrated Baseboard Management Controller (Integrated
BMC), IPMI 2.0 compliant
4 Intel® Server System SR1630GP / SR1630HGP Service Guide
AF001000
BA
D
E
F
GC

Chassis Component Identification

This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label on the inside of the chassis cover to assist in identifying components.

System Front Panel (SR1630GP)

The front of the server system includes the following buttons and LEDs.
A. USB Port E. Hard Disk Drive Activity LED B. Power Button F. NIC1 LED C. System Status LED G. NIC2 LED D. System Power LED
Figure 3. Front Controls and LEDs (SR1630GP)
Table 2. Intel® Server System SR1630GP Control Panel LED Functions
LED Color State Description
NIC 1 / NIC 2 Activity
Power / Sleep
Green On NIC Link / AC is on / no access Green Blink LAN access Green On Power on Off Off Power Off / ACPI S4 state
Intel® Server System SR1630GP / SR1630HGP Service Guide 5
Table 2. Intel® Server System SR1630GP Control Panel LED Functions
LED Color State Description
System Status (on standby power)
Disk Activity Green Random
Green On Running / normal operation
Blink System ready, but degraded
Amber On Critical or non-recoverable condition. Possible critical
Blink Non-critical condition
Off Off POST / system stop. System not ready.
blink
Off Off No hard disk drive activity
power module failure, critical fan failure , voltage (power supply), voltage and thermal fault
HDD access
6 Intel® Server System SR1630GP / SR1630HGP Service Guide
C
A
B
E
G F
AF001573
D

System Front Panel (SR1630HGP)

The front of the server system includes the following buttons and LEDs.
A. NIC1 LED E. HDD Activity LED B. NIC2 LED F. USB Port C. Power LED G. Power Button D. System Status LED
Figure 4. Front Controls and LEDs (SR1630HGP)
Table 3. Intel® Server System SR1630HGP Control Panel LED Functions
LED Color State Description
NIC 1 / NIC 2 Activity
Power / Sleep
System Status (on standby power)
Green On NIC Link / System is On Green Blink LAN access Green On Power on
Blink Sleep / ACPI S1 state Off Off Power Off / ACPI S4 state N/A N/A N/A
Disk Activity Green Random
blink Off Off No hard disk drive activity
Intel® Server System SR1630GP / SR1630HGP Service Guide 7
HDD access

System Rear

A. AC Power Connector E. NIC 2 Connector (10/100/1000 MB) B. Serial Port A F. USB Ports 6 and 7 C. Video Connector G. USB Ports 8 and 9 D. NIC 1 Connector (10/100/1000 MB) H. PCI Express* Slot
Figure 5. Back Panel Connectors
The NIC LEDs at the right and left of each NIC provide the following information.
Table 4. NIC LED Descriptions
LED LED State LED State NIC State
Left Green Off LAN link is not established.
On LAN link is established. Blinking LAN activity is occurring.
Red N/A Off 10 Mbit / sec data rate is
Green On 100 Mbit / sec data is
Yellow On 1000 Mbit / sec data rate is
selected
selected
selected
8 Intel® Server System SR1630GP / SR1630HGP Service Guide
Loading...
+ 166 hidden pages