Intel SR2600URLX, SR1500, SR1550, SR1600, SR1625 Hardware Installation Manual

...
Page 1
Basic Rail Kit Install Guide for Intel® Server Chassis
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Intel® Server Chassis SR1500
Intel® Server Chassis SR1550
Intel® Server Chassis SR1600
Intel® Server Chassis SR1625
Intel® Server Chassis SR2400
Intel® Server Chassis SR2500
Intel® Server Chassis SR2600
Intel® Server Chassis SR2625
Intel® Server System SR1560SF
Intel Order Number: D59599-003, Rev. 02
Page 2
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel® products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel® server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others.
Copyright © 2008, Intel Corporation. All Rights Reserved
ii Basic Rail Kit Install Guide for Intel® Server Chassis
Page 3
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Deployment Toolkit CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
Consignes de sécurité
®
Server Deployment Toolkit CD
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit CD ou bien rendez-
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
重要安全指导
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit CD y/o en http://support.intel.com/
Basic Rail Kit Install Guide for Intel® Server Chassis iii
Page 4
Safety Information
Warnings
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
iv Basic Rail Kit Install Guide for Intel® Server Chassis
Page 5
Contents
Contents
Safety Information ..................................................................................................... iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Rail Kit Installation Instructions ................................................................................ 1
Before You Begin ...................................................................................................................1
Tools and Supplies Needed ........................................................................................................ 1
Kit Content List (AXXBASRAIL13) .............................................................................................. 2
Installation Instructions ..........................................................................................................3
Remove the Inner Rail from the Rail Assembly .......................................................................... 3
Install Outer Rail Slides to Rack Posts ....................................................................................... 4
Attach Inner Rails to Server Chassis Sidewalls .......................................................................... 5
Install the Server Chassis into the Rack ..................................................................................... 6
Basic Rail Kit Install Guide for Intel® Server Chassis v
Page 6
Contents
vi Basic Rail Kit Install Guide for Intel® Server Chassis
Page 7
List of Figures
List of Figures
Figure 1. Rail Kit Components ...................................................................................................2
Figure 2. Removing the Inner Rail from the Rail Assembly........................................................ 3
Figure 3. Installing the Outer Rail Slides to the Rack Posts....................................................... 4
Figure 4. Attaching the Inner Rails to the Server Chassis Sidewalls ......................................... 5
Figure 5. Installing the Server Chassis into the Rack................................................................. 6
Figure 6. Installing the Server Chassis into the Rack................................................................. 7
Basic Rail Kit Install Guide for Intel® Server Chassis vii
Page 8
List of Figures
viii Basic Rail Kit Install Guide for Intel® Server Chassis
Page 9
1 Rail Kit Installation Instructions
Use the instructions in this installation guide to install the AXXBASRAIL13 rail kit to one of the following Intel® products:
Intel® Server Chassis SR1500
Intel® Server Chassis SR1550
Intel® Server Chassis SR1600
Intel® Server Chassis SR1625
Intel® Server Chassis SR2400
Intel® Server Chassis SR2500
Intel® Server Chassis SR2600
Intel® Server Chassis SR2625
Intel® Server System SR1560SF
Before You Begin
Before installing the rail kit, observe these safety guidelines:
1. Turn off all peripheral devices connected to the server.
2. Turn off the server by pressing the power button on the front of the chassis. Then unplug the AC power cord(s) from the chassis or wall outlet.
3. Label and disconnect all peripheral cables and all telecommunications lines connected to I/O connectors or ports on the back of the chassis.
4. Provide electrostatic discharge (ESD) protection by wearing an anti-static wrist strap attached to a chassis ground - any unpainted metal surface - when handling components.
Tools and Supplies Needed
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Anti-static wrist strap and conductive foam pad (recommended)
Basic Rail Kit Install Guide for Intel® Server Chassis 1
Page 10
Rail Kit Installation Instructions
Kit Content List (AXXBASRAIL13)
Each Rack Mount Kit contains the following:
Note: The two included rail assemblies are NOT interchangeable. Each is installed into the rack
by its orientation (right or left) when standing in front of the rack. The right rail assembly is identified with a BLUE (RH) sticker and the left rail assembly is identified with a GREEN (LH) sticker.
Note: This kit includes two sets of 8-32x1/2” screws. One set of eight has a larger screw head
size than the second set of eight. Use the set of 8-32x1/2” screws that best fits the rack in which the rail kit is being installed.
Outer Rail Slide Assembly (2). See letter “A” in Figure 1.
Inner Rail Slide (2). See letter “B” in Figure 1.
Rail Safety Stop (one each on inner slides). See letter “C” in Figure 1.
Outer Slide Rail Screws (8 #8-32 x 1/2). See letter “D” in Figure 1.
Inner Slide Rail Screw (8 #6-32 x 1/4). See letter “D” in Figure 1.
Rack Screws (2 #8-32 x 3/4). See letter “D” in Figure 1.
D
C
Adjustable Outer Slide
Inner Slide with Safety Stop
A
B
Figure 1. Rail Kit Components
AF000626
2 Basic Rail Kit Install Guide for Intel® Server Chassis
Page 11
Installation Instructions
Remove the Inner Rail from the Rail Assembly
1. Extend the inner rail until it locks. See letter “A” in Figure 2.
2. Depress the spring safety lock to release the inner rail. See letter “B” in Figure 2.
3. Remove the inner rail from the rail assembly. See letter “C” in Figure 2.
Rail Kit Installation Instructions
Figure 2. Removing the Inner Rail from the Rail Assembly
Basic Rail Kit Install Guide for Intel® Server Chassis 3
Page 12
Rail Kit Installation Instructions
Install Outer Rail Slides to Rack Posts
1. Attach the outer rail slides to the rack posts using two #8-32 x 1/2 screws at the front posts, and two #8-32 x 1/2 screws at the rear posts. See letter “A” in Figure 3.
Note: The rail flanges mount to the inside of each post.
Rear of Rack
Front of Rack
Figure 3. Installing the Outer Rail Slides to the Rack Posts
AF000628
4 Basic Rail Kit Install Guide for Intel® Server Chassis
Page 13
Attach Inner Rails to Server Chassis Sidewalls
1. Insert the inner rails over the server chassis sidewall studs. See letter “A” in Figure 4.
2. Slide the inner rails toward the front of the server chassis. See letter “B” in Figure 4.
3. Secure the inner rails with one #6-32 x 1/4 screw for each rail. See letter “C” in
Figure 4.
Rail Kit Installation Instructions
Figure 4. Attaching the Inner Rails to the Server Chassis Sidewalls
Basic Rail Kit Install Guide for Intel® Server Chassis 5
Page 14
Rail Kit Installation Instructions
Install the Server Chassis into the Rack
1. Align the inner rails (attached to the server chassis) with the outer rail assemblies (attached to the rack). See letter “A” in Figure 5.
Note: The inner slides must be positioned all the way forward in the rails to ensure proper
installation of the server.
2. Engage the matching rails and slide the server chassis into the rack (see letter “B” in
Figure 5) until the two safety stops lock into position (see letter “C” in Figure 5).
Figure 5. Installing the Server Chassis into the Rack
6 Basic Rail Kit Install Guide for Intel® Server Chassis
Page 15
Rail Kit Installation Instructions
3. Depress the two safety locks (one on each side). See letter “A” in Figure 6.
4. Slide the server chassis all the way into the rack. See letter “B” in Figure 6.
5. Use the rack screws (#8-32 x 3/4) to secure the chassis and rack handles into the rack. See letter “C” in Figure 6.
Figure 6. Installing the Server Chassis into the Rack