A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D92960-003
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation where
personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time,
without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate
airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the system integrator that
chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation
can not be held responsible if components fail or the server board does not operate correctly when used outside any
of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
Thank you for purchasing and using the Intel® Server System SR1560SF.
This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server system. This document provides reference
information, feature information, and step by step instructions on how to add and replace
components on the server system. For the latest version of this manual, see http://
Chapter 1 provides a list of reference resources. In this chapter you will find a list of
technical documents that give additional details on the Intel
and the location where they can be found.
Chapter 2 provides a brief overview of the server system. In this chapter, you will find a
list of the server system features, illustrations of the product, and product diagrams to help
you identify components and their locations.
Chapter 3 provides instructions on adding and replacing components. Use this chapte r for
step-by-step instructions and diagrams for installing or replacing components such as the
fans, power supply, drives, and other components.
Chapter 4 provides instructions on using the utilities that are shipped with the board or
that may be required to update the system. This includes how to navigate through the
BIOS Setup screens, how to perform a BIOS update, and how to reset the password or
CMOS. Information about the specific BIOS settings and screens is available in the Intel
Server Board S5400SF T echnical Product Specification. See “Server System References”
for a link to the Intel
At the back of this manual, you will find technical specifications, regulatory information,
"getting help" information, and the warranty.
®
Server Board S5400SF Technical Product Specification.
®
Server System SR1560SF,
®
Product Contents
The Intel® Server System SR1560SF ships with the Intel® Server Board S5400SF. For
further information, see the following documents:
•Intel
•Intel
There are two versions of the Intel
and SR1560SFHS. The contents of each server system are listed below.
Intel® Server System SR1560SF - Product Code SR1560SF
Contents
Your Intel® Server System SR1560SF ships with the following items:
•Intel
•One 600 W power supply, installed in the server system
•A box of hardware components, referred to below as the "hardwar e box"
•PCIe* riser card assembly, installed in the server system
•Optical drive tray assembly (tray and interposer board), in hardware box
®
Server Board S5400SF Technical Product Specification
®
Server System SR1560SF Technical Product Specification
®
Server System SR1560SF: product codes SR1560SF
®
Server Board S5400SF, installed in the server system
•Optical drive cable, in hardware box
•Attention document, in the server system product box
•Quick Start User's Guide, in the server system product box
•One 32-6mm flat screw for installing the optical drive component, in the hardware
box
•Rack handles, in hardware box
•Slimline peripheral bay filler panel, in the hardware box
•Standard control panel module and cables (I/O and USB), installed in the server
system
•Two fixed mount drive trays and drive filler blanks, installed in the server system
•System fan board and fan board I/O cable, installed in the server system
•System fan assembly, including five dual-rotor fans, installed in the server system
•Two SATA cables, in hardware box
•Processor air duct, installed in the server system
•Blue plastic air baffle, installed in the server system
•Intel
•Intel
®
Server Deployment Toolkit 2.0 CD
®
System Management Software CD
viIntel® Server System SR1560SF Service Guide
Intel® Server System SR1560SF - Product Code
SR1560SFHS Contents
Your Intel® Server System SR1560SF ships with the following items:
•Intel
•One 600 W power supply, installed in the server system
•A box of hardware components, referred to below as the "hardware box"
•PCIe* riser card assembly, installed in the server system
•Optical drive tray assembly (tray and interposer board), in the hardware box
•Bridge board, in the hardware box
•Optical drive cable, in the hardware box
•Attention document, in the server system product box
•Quick Start User's Guide, in the server system product box
•One 32-6mm flat screw for installing the optical drive component, in the hardware
•Rack handles, in the hardware box
•Slimline peripheral bay filler panel, in the hardware box
•Standard control panel module and cable, installed in the server system
®
Server Board S5400SF, installed in the server system
box
•Three hot-swap drive trays and drive filler blanks, installed in the server system
•System fan assembly, including five dual-rotor fans, installed in the server system
•Processor air duct, installed in the server system
•Blue plastic air baffle, installed in the server system
•Intel
•Intel
Note: One of two hot-swap backplane kits must be ordered separately in order to make the
system operational. The following kits are available for purchase.
®
Server Deployment Toolkit 2.0 CD
®
System Management Software CD
•Passive hot-swap backplane. Order code: ASR1500PASBP
•Active hot-swap backplane. Order code: ASR1500SASBP
Intel® Server System SR1560SF Service Guidevii
viiiIntel® Server System SR1560SF Service Guide
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the
instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
Intel-Serverplatinen und Servergehäusen auf der Intel
oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment T oolkit 2.0 CD
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
document avant de suivre toute instruction. Consultez Intel Server Boards and Server
Chassis Safety Information sur le Intel
rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-
010770.htm.
®
Server Deployment Toolkit 2.0 CD ou bien
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety
Information en el Intel
上的 Intel
Server Boards and Server Chassis Safety Information(《Intel
服务器主板与服务器机箱安全信息》)。
xIntel® Server System SR1560SF Service Guide
Warnings
Heed safety instructions: Before working with your server product, whether you are
using this guide or any other resource as a reference, pay close attention to the safety
instructions. You must adhere to the assembly instructions in this guide to ensure and
maintain compliance with existing product certifications and approvals. Use only the
described, regulated components specified in this guide. Use of other products /
components will void the UL listing and other regulatory approvals of the product and
will most likely result in noncompliance with product regulations in the region(s) in which
the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To
remove power from system, you must unplug the AC power cord from the wall outlet.
Make sure the AC power cord is unplugged before you open the chassis, add, or remove
any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the server and
disconnect the power cord, telecommunications systems, networks, and modems attached
to the server before opening it. Otherwise, personal injury or equipment damage can
result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
boards, and other parts. We recommend that you perform all procedures in this chapter
only at an ESD workstation. If one is not available, provide some ESD protection by
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to ESD. Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded,
static free surface. Use a conductive foam pad if available but not the board wrapper. Do
not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that you can grip with your
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,
take care when using needle nosed pliers to remove or install a jumper; grip the narrow
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with the function
controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool
you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1560SF Service Guidexi
xiiIntel® Server System SR1560SF Service Guide
Table of Contents
Preface ......................................................................................................................... v
About this Manual ..................................................................................................................v
Manual Organization .............................................................................................................. v
Product Contents .................................................................................................................. vi
Safety Information .....................................................................................................ix
Important Safety Instructions ................................................................................................ ix
Wichtige Sicherheitshinweise ............................................................................................... ix
Consignes de sécurité ..........................................................................................................ix
Instrucciones de seguridad importantes ............................................................................... ix
Chapter 1: Server System References ..................................................................... 1
Chapter 2: Server System Features ..........................................................................3
Table 10. Other Markings ........................................................................................................90
®
Server System SR1560SF Feature Summary ...................................................4
Intel® Server System SR1560SF Service Guidexxi
xxiiIntel® Server System SR1560SF Service Guide
1Server System References
If you need more information about this product or information about the accessories that
can be used with this server system, use the following resources.
Table 1. Server System References
For this information or
software
For in-depth technical
information about the
server system, including
sub-system overviews
and mechanical drawings
For basic BIOS settings
and chipset information
For in-depth BIOS
information
For in-depth firmware
information on the
Baseboard Management
Controller (BMC)
For in-depth information
®
on Intel
Technology
I/O Acceleration
Use this Document or Software
®
Intel
Server System SR1560SF Technical Product Specification
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
and available on the Intel
Intel® Server Board S5400SF Technical Product Specification
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
and available on the Intel
®
Intel
Server Board S5400SF Technical Product Specification
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
®
Intel
5400 Chipset Server Board Family Server BIOS External
Product Specification
Found: available to order by contacting your Intel field
representative.
Found: available to order by contacting your Intel field
representative.
®
Intel
I/O Acceleration Technology Improves Intel Server Platform
Network Performance, Reliability, and Efficiency whitepaper
Found: available from your Intel field representative.
®
Server Deployment Toolkit 2.0 CD.
®
Server Deployment Toolkit 2.0 CD.
If you just received this
product and need to
install it
Accessories or other Intel
server products
Intel® Integrated Server System SR1560SF Quick Start User's
Guide
®
Found: in the product box and available on the Intel
Deployment Toolkit 2.0 CD.
Spares and Configuration Guide
Found: available from your Intel field representative or on the
Server Configurator Tool at http://indigo.intel.com/
serverconfiguratortool/default.aspx
Server
Table 1. Server System References
For this information or
software
Hardware (peripheral
boards, adapter cards)
and operating systems
that have been tested with
this product
To make sure your system
falls within the allowed
power budget
For software to manage
your Intel
®
server
For diagnostics test
software
Use this Document or Software
Tested Hardware Operating Systems List
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
Power Budget Tool
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
®
System Management Software
Intel
Found: available on the Intel® System Management Software CD
that ships with your system.
Diagnostics: Platform Confidence Test (PCT)
Found at:
http://support.intel.com/support/motherboards/server/S5400SF/
and available on the Intel
®
Server Deployment Toolkit 2.0 CD.
2Intel® Server System SR1560SF Service Guide
2Server System Features
This chapter briefly describes the main features of the server system. This chapter
provides illustrations of the product, a list of the server system features, and diagrams
showing the location of important components and connections on the se rv er sy s t em .
AF002374
Figure 1. Intel
®
Server System SR1560SF
Table 2 summarizes the features of the server system.
®
Table 2. Intel
FeatureDescription
Server System SR1560SF Feature Summary
Dimensions
• 1.703 inches (43.25 mm) high
• 16.930 inches (430 mm) wide
• 27.25 inches (692 mm) deep
• 31 pounds (14.1 kg) - max chassis weight
®
Server BoardIntel
Processor Support for up to two Multi-Core Intel
Server Board S5400SF
sequence.
For a complete list of supported processors, see:
VideoOn-board ATI* ES1000 video controller with 16 MB DDR SDRAM
4Intel® Server System SR1560SF Service Guide
Table 2. Intel® Server System SR1560SF Feature Summary
FeatureDescription
LANIntel
Ethernet LAN connectivity
®
82563EB dual port controller for 10/100/1000 Mbit/sec
Expansion Capabilities
Hard Drive Options
• One PCI Express* x16 GEN2 add-in card slot
• Fixed drive system:
– Two SATA drives
• Hot-swap drive system:
– Three SATA/SAS drives
®
• Intel
Embedded Server RAID Technology II with SW RAID
levels 0/1/10
• Optional support for SW RAID 5 with enablement key
Peripherals
• Slimline bay for IDE optical drive
• Optional USB floppy drive (product code SR1560SFHS)
Control Panel
LEDs and displaysWith standard control panel:
• Standard control panel
• NIC1 Activity
• NIC2 Activity
• Power / Sleep
• System Status
• System Identification
• Hard Drive Activity
Internal light guided diagnostics:
• Fan Fault
• Memory Fault
• CPU Fault
• 5VSB
• System Status
• System Identification
Power SupplySingle 600 W power supply
Fans
USB
System ManagementIntel
Intel® Server System SR1560SF Service Guide5
• Five non-redundant, monitored and controlled system fans
• Two non-redundant fans in power supply
• One front panel USB 2.0 port
• Two back I/O USB 2.0 ports
®
System Management Software
Cable Routing (Hot-Swap Drive System)
When you add or remove components from your server system, make sure your cables are
routed correctly before reinstalling the server system cover. Use caution to make sure no
cables or wires are pinched and that the airflow from the fans is not blocked. Use the
figures below to determine the correct cable routing for a hot-swap drive system.
Intel® Remote Management
A
B
C
D
E
F
(optional)
Module
Intel® RMM NIC Module
I/O Module
Power Supply
Bridge Board
Backplane Board
(optional)
D
Power
Supply
I
J
(optional)
(passive shown)
BC
A
Server
Board
G
H
Power to Server Board
G
Power to Server Board
H
Power to Server Board
I
Power to Backplane Board (P3)
J
Control Panel USB
K
Control Panel Data
L
Fan Power Cables
M
E
CPU2
CPU1
Fan Module
(Aux. - P4)
(Main - P1)
(CPU - P2)
Figure 2. Cable Routing for Hot-Swap Drive System
6Intel® Server System SR1560SF Service Guide
F
Optical
Drive
Module
Drive Bays
M
L
K
Control
Panel
Module
AF002352
Cable Routing (Fixed Drive System)
When you add or remove components from your server system, make sure your cables are
routed correctly before reinstalling the server system cover. Use caution to make sure no
cables or wires are pinched and that the airflow from the fans is not blocked. Use the
figures below to determine the correct cable routing for a fixed drive system.
Power to Fan Board (P3)
I
Intel® Remote Management
A
(optional)
Module
Intel® RMM NIC Module
B
I/O Module
C
Power Supply
D
Fan Board
E
Power to Server Board
F
Power to Server Board
G
Power to Server Board
H
(optional)
BC
(optional)
(Aux. - P4)
(Main - P1)
(CPU - P2)
A
Fan Power Cables
J
Control Panel Data
K
Control Panel USB
L
Power to Fixed HDD
M
SATA Data to HDD 1
N
Power to Fixed HDD
O
SATA Data to HDD 0
P
Optical Drive Data
Q
D
Power
Supply
H
I
Q
Optical
Drive
Module
Server
Board
CPU1
F
G
NP
Drive Bays
CPU2
Fan Module
J
MO
E
K
L
Control
Panel
Module
AF002353
Figure 3. Cable Routing for Fixed Drive System
Intel® Server System SR1560SF Service Guide7
Chassis Component Identification
This section helps you identify the components of your server system. If you are near the
system, you can also use the Quick Reference Label provided on the inside of the chassis
cover to assist in identifying components.
Internal Components
C
B
A
M
D
E
F
G
L
H
K
J
A.Rack handlesH.Fan module
B.Air baffleI.Fan board (fixed drive system) or