Intel® Server System SR1550AL/
SR1550ALSAS User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D31972-002
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation where
personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time,
without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate
airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the system integrator that
chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation
can not be held responsible if components fail or the server board does not operate correctly when used outside any
of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
iiIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
Intel® Server System SR1550AL/SR1550ALSAS User’s Guideiii
§
ivIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
Preface
About this Manual
Thank you for purchasing and using the Intel® Server System SR1550AL.
This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server system. This document provides reference
information, feature information, and step by step instructions on how to add and replace
components on the server system. For the latest version of this manual, see http://
Chapter 1 provides a list of reference resources. In this chapter you will find a list of
technical documents that give additional details on the Intel
and the location where they can be found.
Chapter 2 provides a brief overview of the server system. In this chapter, you will find a
list of the server system features, illustrations of the product, and product diagrams to help
you identify components and their locations.
Chapter 3 provides instructions on using the utilities that are shipped with the board or
that may be required to update the system. This includes how to navigate through the
BIOS Setup screens, how to perform a BIOS update, and how to reset the password or
CMOS. Information about the specific BIOS settings and screens is available in the Intel
5000 Series Chipsets Server Board Family Datasheet. See “Server System References” for
a link to the Intel
Chapter 4 provides instructions on adding and replacing components. Use this chapte r for
step-by-step instructions and diagrams for installing or replacing components such as the
fans, power supply, drives, and other components.
At the back of this manual, you will find technical specifications, regulatory information,
"getting help" information, and the warranty.
®
5000 Series Chipsets Server Board Family Datasheet.
®
Server System SR1550AL,
®
Product Contents
The Intel® Server System SR1550AL ships with the Intel® Server Board S5000PAL. For
further information, see the Intel
®
Server Board S5000PAL User’s Guide.
Intel® Server System SR1550AL Contents
Your Intel® Server System SR1550AL ships with the following items:
•Intel
•One 650 W power supply module, installed in the server system
•A box of hardware components, referred to below as the "hardwar e box"
•Full and low profile riser, installed in the server system
•Optical drive tray assembly
•Bridge board, installed in the server system
•Fan cable, installed in the server system
•Chassis intrusion switch, integrated into the server system riser
•Attention document, in the server system product box
•Quick Start User's Guide, in the server system product box
•Two screws for installing the optical drive component, in the hardware box
•Rack handles, in the hardware box
®
Server Board S5000PAL, installed in the server system
•USB cable
•Peripheral bay filler panel, installed in the server system
•Mini control panel, installed in the server system
•Active or passive mid-plane, installed in the server system
viIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the
instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
Intel-Serverplatinen und Servergehäusen auf der Intel
unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD oder
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
document avant de suivre toute instruction. Consultez Intel Server Boards and Server
Chassis Safety Information sur le Intel
sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD ou bien rendez-vous
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety
Information en el Intel
support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD y/o en http://support.intel.com/
上的 Intel
Server Boards and Server Chassis Safety Information(《Intel
服务器主板与服务器机箱安全信息》)。
viiiIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
Warnings
Heed safety instructions: Before working with your server product, whether you are
using this guide or any other resource as a reference, pay close attention to the safety
instructions. You must adhere to the assembly instructions in this guide to ensure and
maintain compliance with existing product certifications and approvals. Use only the
described, regulated components specified in this guide. Use of other products /
components will void the UL listing and other regulatory approvals of the product and
will most likely result in noncompliance with product regulations in the region(s) in which
the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To
remove power from system, you must unplug the AC power cord from the wall outlet.
Make sure the AC power cord is unplugged before you open the chassis, add, or remove
any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the server and
disconnect the power cord, telecommunications systems, networks, and modems attached
to the server before opening it. Otherwise, personal injury or equipment damage can
result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
boards, and other parts. We recommend that you perform all procedures in this chapter
only at an ESD workstation. If one is not available, provide some ESD protection by
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to ESD. Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded,
static free surface. Use a conductive foam pad if available but not the board wrapper. Do
not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that you can grip with your
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,
take care when using needle nosed pliers to remove or install a jumper; grip the narrow
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with the function
controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool
you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1550AL/SR1550ALSAS User’s Guideix
xIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
List of Figures
Figure 1. Intel® Integrated Server System SR1550AL .............................................................. 3
Server System SR1550AL Feature Summary ...................................................4
®
Remote Management Module ..................99
Intel® Server System SR1550AL/SR1550ALSAS User’s Guidexix
xxIntel® Server System SR1550AL/SR1550ALSAS User’s Guide
1Server System References
If you need more information about this product or information about the accessories that
can be used with this server chassis, use the following resources.
Table 1. Server System References
For this information or
software
For in-depth technical
information about the
server chassis, including
sub-system overviews
and mechanical drawings
For in-depth technical
information about the
server board, including
board layout, connector
pin-outs, timing
information, mechanical
drawings and LED
information
For basic BIOS settings
and chipset information
For in-depth BIOS
information
For in-depth firmware
information on the
Baseboard Management
Controller (BMC)
For in-depth information
®
on Intel
Technology
I/O Acceleration
Use this Document or Software
®
Intel
Server Chassis SR1550 Technical Product Specification
Found at:
http://support.intel.com/support/motherboards/server/chassis/
SR1550/
®
Intel
Server Board S5000PAL Technical Product Specification
2Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
2Server System Features
This chapter briefly describes the main features of the server system. This chapter
provides a illustrations of the product, a list of the server system features, and diagrams
showing the location of important components and connections on the server system.
TP02211
Figure 1. Intel
®
Integrated Server System SR1550AL
Table 2 summarizes the features of the server system.
• One full height riser slot supporting 1U PCI-X* and PCI
Express* riser cards
Hard Drives
4Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
• Up to eight 2.5 inch hot-swap SATA / SAS drives
Table 2. Intel® Server System SR1550AL Feature Summary
FeatureDescription
Peripherals
Control Panel (dependent
on option selected)
LEDs and displays
(dependent on option
selected)
• Slimline bay for IDE optical drive
• PCI riser card bracket
• Standard control panel
®
• Intel
Local Control Panel
• Mini control panel
With standard control panel:
• NIC1 Activity
• NIC2 Activity
• Power / Sleep
• System Status
• System Identification
• Hard Drive Activity
®
With Intel
Local Control Panel:
• NIC1 Activity
• NIC2 Activity
• Power / Sleep
• System Status
• System Identification
• Hard Drive Activity
• LCD Display
Power SupplyUp to two 650W power supply modules
Fans
• Six 4-pin fan headers supporting two processor fans, and four
system fans
• Dedicated non-redundant power supply fan (one per module)
USB
• One front panel USB port
• One internal USB header providing two USB ports
System ManagementIntel
®
System Management Software
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide5
Chassis Component Identification
This section helps you identify the components of your server system. If you are near the
system, you can also use the Quick Reference Label provided on the inside of the chassis
cover to assist in identifying components.
Internal Components
F
E
D
C
B
A
P
O
A.Rack HandleI.PCI Riser Assembly
B.Slimline Optical Drive Bay (Optical Drive
Shown)
C.SR1550ALSAS RAID Battery Pack
(Optional)
D.Power Distribution BoardL.Bridge Board
E.Power Supply Air DuctM. Mid-plane Board (Active Shown)
F.Power Supply Filler (Second Power Supply
if Installed)
G. Power Supply ModuleO.Rack Handle
H.Server BoardP.Hard Drive Bays
J.Processor Air Duct
K.Fan Assembly
N.Mini Control Panel Bay
G
H
I
J
K
L
M
N
TP02212
Figure 2. ChassisComponents
6Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Server Board Connector and Component
Locations
QQ
OO
NN
GG
DD
CC
PP
KK
HH
FF
EE
BB
AA
B
A
MM
LL
JJ
II
Z
Y
X
C
W
V UST
F
ED
I
G
H
J
K
L
M
N
O
P
Q
R
TP02071
Figure 3. Server Board Connector and Component Locations
Adaptive Slot - Full HeightF.PCI Express* Riser Slot - Low
Profile
G.System Identification LED - BlueH.Back Panel I/O PortsI.Status LED - Green/Amber
J.Serial B Configuration JumperK.System Fan 4 HeaderL.System Fan 3Header
M.DIMM SocketsN.Intel
®
5000P MCHO.Processor 1 Socket
P.Processor 2 SocketQ.Processor Fan 1 HeaderR.Voltage Regulator Heat Sink
S.Processor Fan 2 HeaderT.Bridge Board ConnectorU.ATA-100 Optical Drive Connector
(Power + IO)
V.System Fan 2 HeaderW. CPU Power ConnectorX.Main Power Connector
Y.BatteryZ.Power Supply Management
AA. Dual Port USB 2.0 Header
Connector
BB. System Fan 1 HeaderCC. 24-pin SSI Control Panel
Connector
DD. SATA Port 0
EE. SATA Port 1FF. SATA Port 2GG. SATA Port 3
HH. SATA Port 4II.SATA Port 5JJ. SATA SW RAID 5 Activation Key
Connector
KK. Intel
NN. 3-pin IPMB HeaderOO. Intel
QQ. Intel
®
Remote Management
Module (RMM) Connector
®
RMM NIC Connector
LL. System Recovery JumpersMM. Chassis Intrusion Switch Header
®
Local Control Panel HeaderPP. Serial A Header
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide7
Configuration Jumpers
BIOS Select
J3H1
3
3
1-2: Force
Lower Bank
2-3: Normal
Operation (Default)
TP02087
Jumper NameJumper Purpose
BIOS SelectIf pins 1-2 are jumpered, the BIOS in the lower bank will be selected
on the next reset. These pins should be jumpered on 2-3 for normal
operation.
Figure 4. BIOS Select Jumper
8Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
BMC Force
Update Mode
2
3
J1D2
Password
Reset
2
3
J1D3
Clear
CMOS
2
3
J1D1
Disable
Enable
TP02080
Jumper NameJumper Purpose
CMOS ClearIf pins 2-3 are jumpered, the CMOS settings will be cleared on the
next reset. These pins should be jumpered on 1-2 for normal
operation.
Password ClearIf pins 2-3 are jumpered, administrator and user passwords will be
cleared on the next reset. These pins should be jumpered on 1-2 for
normal operation.
BMC Force Update ModeIf pins 2-3 are jumpered, BMC Force Update Mode is enabled.
These pins should be jumpered on 1-2 for normal operation.
Figure 5. Recovery Jumpers
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide9
Intel® Light Guided Diagnostics
The server board contains diagnostic LEDs to help you identify failed and failing
components, and to help you identify the server from among several servers. Except for
the ID LED, the status LED, and the 5V standby LED, the LEDs turn on (amber) only if a
failure occurs.
A
POST
Code LEDs
D
E
N
CPU 2
Socket
C
Light Guided
Diagnostics
Legend
through
A
F
DIMM A1
DIMM A2
DIMM B1
DIMM B2
JHK
DIMM C1
DIMM C2
DIMM D1
DIMM D2
I
G
L
M
CPU 1
Socket
A. POST Code LEDs
B. ID LED
C. Status LED
D. DIMM A1 Fault
E. DIMM A2 Fault
F. DIMM B1 Fault
G. DIMM B2 Fault
H. DIMM C1 Fault
I. DIMM C2 Fault
J. DIMM D1 Fault
K. DIMM D2 Fault
L. CPU 1 Fault
M. CPU 2 Fault
N. 5V Standby
N
B
AF000644
Figure 6. Light Guided Diagnostic LEDs
10Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Loading...
+ 152 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.