Intel SR1550AL, SR1550ALSAS User Manual

Intel® Server System SR1550AL/ SR1550ALSAS User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Intel Order Number D31972-002
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others. Copyright © 2006, Intel Corporation. All Rights Reserved
ii Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide iii
§
iv Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Preface
About this Manual
Thank you for purchasing and using the Intel® Server System SR1550AL. This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http://
support.intel.com/support/motherboards/server/chassis/SR1550/.
Manual Organization
Chapter 1 provides a list of reference resources. In this chapter you will find a list of technical documents that give additional details on the Intel and the location where they can be found.
Chapter 2 provides a brief overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.
Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Intel 5000 Series Chipsets Server Board Family Datasheet. See “Server System References” for a link to the Intel
Chapter 4 provides instructions on adding and replacing components. Use this chapte r for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
At the back of this manual, you will find technical specifications, regulatory information, "getting help" information, and the warranty.
®
5000 Series Chipsets Server Board Family Datasheet.
®
Server System SR1550AL,
®
Product Contents
The Intel® Server System SR1550AL ships with the Intel® Server Board S5000PAL. For further information, see the Intel
®
Server Board S5000PAL User’s Guide.
Intel® Server System SR1550AL Contents
Your Intel® Server System SR1550AL ships with the following items:
Intel
One 650 W power supply module, installed in the server system
A box of hardware components, referred to below as the "hardwar e box"
Full and low profile riser, installed in the server system
Optical drive tray assembly
Bridge board, installed in the server system
Fan cable, installed in the server system
Chassis intrusion switch, integrated into the server system riser
Attention document, in the server system product box
Quick Start User's Guide, in the server system product box
Two screws for installing the optical drive component, in the hardware box
Rack handles, in the hardware box
®
Server Board S5000PAL, installed in the server system
USB cable
Peripheral bay filler panel, installed in the server system
Mini control panel, installed in the server system
Active or passive mid-plane, installed in the server system
vi Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/
Intel
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD oder
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD ou bien rendez-vous
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel
support/motherboards/server/sb/cs-010770.htm.
®
Deployment Toolkit 2.0 CD y/o en http://support.intel.com/
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm
上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
viii Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Warnings
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide ix
x Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
List of Figures
Figure 1. Intel® Integrated Server System SR1550AL .............................................................. 3
Figure 2. ChassisComponents.................................................................................................. 6
Figure 3. Server Board Connector and Component Locations ................................................. 7
Figure 4. BIOS Select Jumper................................................................................................... 8
Figure 5. Recovery Jumpers ..................................................................................................... 9
Figure 6. Light Guided Diagnostic LEDs ................................................................................. 10
Figure 7. Back Panel Connectors............................................................................................ 11
Figure 8. Passive SATA Mid-Plane Components.................................................................... 13
Figure 9. Active SAS/SATA Mid-Plane Components .............................................................. 14
Figure 10. Mini Control Panel.................................................................................................. 15
Figure 11. Standard Control Panel.......................................................................................... 17
Figure 12. Intel
Figure 13. Front Panel Features and Peripherals ................................................................... 19
Figure 14. Front Bezel Supporting the Standard Control Panel.............................................. 24
Figure 15. Front Bezel Supporting the Intel
Figure 16. Front Bezel Supporting the Mini Control Panel...................................................... 25
Figure 17. Removing the Front Bezel...................................................................................... 25
Figure 18. Installing the Front Bezel........................................................................................ 26
Figure 19. Removing the Server System Cover...................................................................... 27
Figure 20. Installing the Server System Cover........................................................................ 27
Figure 21. Removing the Processor Air Duct.......................................................................... 28
Figure 22. Removing the Processor 2 Air Dam (Optional - only if two processors are installed). 29
Figure 23. Installing the Processor Air Duct............................................................................ 29
Figure 24. Installing the Memory............................................................................................. 30
Figure 25. Lifting the Processor Socket Handle...................................................................... 32
Figure 26. Installing the Processor.......................................................................................... 32
Figure 27. Removing the Socket Cover .................................................................................. 33
Figure 28. Installing the Heat Sink .......................................................................................... 33
Figure 29. Removing Hot-swap Disk Carrier from the Server System.................................... 35
Figure 30. Installing Hard Drive into Carrier............................................................................ 36
Figure 31. Install Drive Assemby into the Server System ....................................................... 36
Figure 32. Installing the Interposer Board to the Optical Drive................................................ 38
Figure 33. Installing an Optical Drive Assembly into the Server System ................................ 39
Figure 34. Removing the Slimline Optical Drive Assembly from the Server System .............. 40
Figure 35. Removing PCI Riser Assembly from the Server System ....................................... 41
Figure 36. Installing PCI Riser Assembly into the Server System........................................... 42
Figure 37. Removing the PCIe* Riser Card from the Server System...................................... 44
Figure 38. Installing the PCI-X* Riser Card into the Server System ....................................... 45
Figure 39. Installing an Add-In Card........................................................................................ 46
Figure 40. Removing an Add-In Card...................................................................................... 47
Figure 41. Installing the I/O Expansion Module(s) to the Server Board.................................. 48
®
Local Control Panel...................................................................................... 18
®
Local Control Panel.......................................... 24
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide xi
Figure 42. Removing the I/O Expansion Module(s) from the Server Board............................ 49
®
Figure 43. Installing the Intel Figure 44. Removing the Intel
RMM and the Intel® RMM NIC Module to the Server System 50
®
RMM and the Intel® RMM NIC Module from the Server System 51
Figure 45. Removing the Mid-plane from the Server System................................................. 53
Figure 46. Installing the Mid-plane Board into the Server System.......................................... 54
Figure 47. Installing the RAID Activation Key and the RAID Mini DIMM ................................ 55
Figure 48. Removing the Intel
®
Integrated RAID Activation Key and the RAID Mini DIMM ... 56
Figure 49. Installing the RAID Battery Backup Unit ................................................................ 57
Figure 50. Removing the RAID Battery Backup Unit .............................................................. 58
Figure 51. Installing the Server Board .................................................................................... 59
Figure 52. Removing the Server Board .................................................................................. 61
Figure 53. Replacing the Backup Battery ............................................................................... 63
Figure 54. Removing Power Supply Filler Panel from the Server System.............................. 64
Figure 55. Removing Power Supply Module from the Server System.................................... 65
Figure 56. Installing Power Supply Module into the Server System ....................................... 65
Figure 57. Removing the Power Distribution Board Cover ..................................................... 66
Figure 58. Installing the Power Distribution Board Cover ....................................................... 67
Figure 59. Removing Mini Control Panel Module from the Server System............................. 68
Figure 60. Installing Control Panel Module into the Server System........................................ 69
Figure 61. Installing Mini Control Panel Filler into the Server System.................................... 69
Figure 62. Removing the Standard Control Panel from the Server System ........................... 70
Figure 63. Removing Mini Control Panel Filler from the Server System................................. 71
Figure 64. Installing Mini Control Panel into the Server System............................................. 71
Figure 65. Removing a System Fan ....................................................................................... 72
Figure 66. Installing a System Fan ......................................................................................... 73
Figure 67. Removing the Fan Pack ........................................................................................ 74
Figure 68. Installing the Fan Pack .......................................................................................... 75
Figure 69. Installing the Rack Handle..................................................................................... 76
Figure 70. Removing the Rack Handle................................................................................... 77
Figure 71. Clear Password Jumper ........................................................................................ 83
Figure 72. Clear CMOS Jumper ............................................................................................. 84
Figure 73. System Cable Routing........................................................................................... 85
Figure 74. SATA Cable Installation......................................................................................... 86
Figure 75. Diagnostic LED Placement Diagram ................................................................... 106
xii Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Table of Contents
Preface .........................................................................................................................v
About this Manual .................................................................................................................. v
Manual Organization ..............................................................................................................v
Product Contents .................................................................................................................. vi
Safety Information .................................................................................................... vii
Important Safety Instructions ............................................................................................... vii
Wichtige Sicherheitshinweise .............................................................................................. vii
Consignes de sécurité ......................................................................................................... vii
Instrucciones de seguridad importantes .............................................................................. vii
Chapter 1: Server System References .....................................................................1
Chapter 2: Server System Features ..........................................................................3
Chassis Component Identification .........................................................................................6
Configuration Jumpers ...........................................................................................................8
RAID Support .......................................................................................................................12
Front Panel Features and Peripheral Devices .....................................................................19
Advanced Management Options .........................................................................................20
®
Intel
Server System SR1550AL Contents .................................................................. vi
Internal Components .....................................................................................................6
Mini Control Panel .......................................................................................................15
Standard Control Panel ...............................................................................................16
®
Intel
Local Control Panel ...........................................................................................17
Bezels ..........................................................................................................................18
Hard Disk Drives ..........................................................................................................19
Slimline Optical Drive Carrier ......................................................................................19
Intel® Remote Management Module ...........................................................................20
Chapter 3: Hardware Installations and Upgrades .................................................21
Before You Begin .................................................................................................................21
Tools and Supplies Needed ........................................................................................21
System References .....................................................................................................21
Removing and Installing from a Rack ..................................................................................21
Fixed Bracket Rack Mount Removal ...........................................................................21
Fixed Bracket Rack Mount Installation ........................................................................22
Basic Rail Rack Mount Removal .................................................................................23
Basic Rail Rack Mount Installation ..............................................................................23
Tool-less Rail Rack Mount Servicing ...........................................................................24
Removing and Installing the Front Bezel .............................................................................24
Removing the Front Bezel ...........................................................................................25
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide xiii
Installing the Front Bezel ............................................................................................. 26
Removing and Installing the Chassis Cover ........................................................................ 26
Removing the Chassis Cover ...................................................................................... 26
Installing the Server System Cover ............................................................................. 27
Removing and Installing the Processor Air Duct ................................................................. 28
Removing the Processor Air Duct ............................................................................... 28
Installing the Processor Air Duct ................................................................................. 29
Installing and Removing Memory ........................................................................................ 30
Installing DIMMs .......................................................................................................... 30
Removing DIMMs ........................................................................................................ 31
Installing the Processor ............................................................................................... 32
Installing the Heat Sink(s) ........................................................................................... 33
Removing a Processor ................................................................................................ 34
Installing and Removing a Hot-swap Hard Drive ................................................................. 34
Installing a SAS/SATA Hot-swap Hard Disk Drive ...................................................... 35
Removing a SAS/SATA Hot-swap Hard Disk Drive .................................................... 37
Installing or Removing a Slimline Optical Drive or Internal USB Floppy ............................. 37
Installing a Slimline Optical Drive or Internal USB Floppy .......................................... 38
Removing a Slimline Optical Drive or Internal USB Floppy ........................................ 39
Installing and Removing the PCI Riser Assembly ............................................................... 40
Removing the PCI Riser Assembly ............................................................................. 40
Installing the PCI Riser Assembly ............................................................................... 41
Replacing the PCI Express* Riser Card with the PCI-X* Riser Card .................................. 43
Removing the PCI Express* Riser Card ..................................................................... 43
Installing the PCI-X* Riser Card .................................................................................. 45
Installing and Removing a PCI Add-in Card ........................................................................ 46
Installing a PCI Add-in Card ........................................................................................ 46
Removing a PCI Add-in Card ...................................................................................... 47
Installing and Removing the I/O Expansion Module(s) ....................................................... 48
Installing the I/O Expansion Module(s) ....................................................................... 48
Removing the I/O Expansion Module(s) ..................................................................... 49
Installing and Removing the Intel
®
Remote Management Module and the Intel® RMM NIC .. 50 Installing the Intel Removing the Intel
®
RMM and Intel® RMM NIC ........................................................... 50
®
RMM and Intel® RMM NIC ......................................................... 51
Replacing the Mid-plane Board ........................................................................................... 52
Removing the Mid-plane Board ................................................................................... 52
Installing the Mid-plane Board ..................................................................................... 53
Installing and Removing the Intel
®
Integrated RAID Activation Key and the RAID Mini DIMM 55
Installing the Intel Removing the Intel
®
Integrated RAID Activation Key and the RAID Mini DIMM ........... 55
®
Integrated RAID Activation Key and the RAID Mini DIMM ......... 56
Installing and Removing the RAID Battery Backup Unit (BBU) ........................................... 57
Installing the RAID Battery Backup Unit ...................................................................... 57
xiv Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Removing the RAID Battery Backup Unit ....................................................................58
Installing and Removing the Server Board ..........................................................................59
Installing the Server Board ..........................................................................................59
Removing the Server Board ........................................................................................60
Replacing the Backup Battery .............................................................................................62
Replacing or Adding a Power Supply ..................................................................................64
Replacing the Power Distribution Module ............................................................................66
Replacing the Control Panel ................................................................................................68
Reinstalling the Mini Control Panel ......................................................................................70
Reinstalling the Mini Control Panel ..............................................................................70
Removing and Installing the Fan Pack ................................................................................73
Removing the Fan Pack ..............................................................................................73
Installing the Fan Pack ................................................................................................75
Installing and Removing the Rack Handles .........................................................................76
Installing the Rack Handles .........................................................................................76
Removing the Rack Handles .......................................................................................76
Chapter 4: Server Utilities ........................................................................................79
Using the BIOS Setup Utility ................................................................................................79
Starting Setup ..............................................................................................................79
If You Cannot Access Setup ........................................................................................79
Setup Menus ...............................................................................................................79
Upgrading the BIOS .............................................................................................................81
Preparing for the Upgrade ...........................................................................................81
Upgrading the BIOS ....................................................................................................82
Clearing the Password .........................................................................................................82
Clearing the CMOS ..............................................................................................................83
Appendix A: Technical Reference ..........................................................................85
Cable Routing ......................................................................................................................85
750W Single Power Supply Input Voltages .........................................................................86
750W Single Power Supply Output Voltages ......................................................................87
System Environmental Specifications ..................................................................................88
Appendix B: Troubleshooting .................................................................................89
Resetting the System ...........................................................................................................89
Problems following Initial System Installation ......................................................................90
First Steps Checklist ....................................................................................................90
Hardware Diagnostic Testing ...............................................................................................91
Verifying Proper Operation of Key System Lights .......................................................91
Confirming Loading of the Operating System ..............................................................91
Specific Problems and Corrective Actions ...........................................................................92
Power Light Does Not Light .........................................................................................92
No Characters Appear on Screen ...............................................................................93
Characters Are Distorted or Incorrect ..........................................................................93
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide xv
System Cooling Fans Do Not Rotate Properly ............................................................ 94
Drive Activity Light Does Not Light .............................................................................. 94
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light .............................. 94
Cannot Connect to a Server ........................................................................................ 95
Problems with Network ............................................................................................... 95
System Boots when Installing PCI Card ..................................................................... 96
Problems with Newly Installed Application Software ................................................... 96
Problems with Application Software that Ran Correctly Earlier .................................. 96
Devices are not Recognized under Device Manager (Microsoft* Windows* Operating
System) ........................................................................................................... 97
Hard Drive(s) are not Recognized ............................................................................... 97
Bootable CD-ROM Disk Is Not Detected .................................................................... 97
LED Information .......................................................................................................... 98
BIOS POST Beep Codes ............................................................................................ 98
Appendix C: Intel® Server Issue Report Form .....................................................101
Appendix D: LED Decoder .....................................................................................105
Appendix E: Getting Help .......................................................................................111
World Wide Web ............................................................................................................... 111
Telephone ......................................................................................................................... 111
Appendix F: Regulatory and Compliance Information ........................................115
Product Regulatory Compliance ........................................................................................ 115
Product Safety Compliance ....................................................................................... 115
Product EMC Compliance - Class A Compliance ..................................................... 116
Certifications / Registrations / Declarations .............................................................. 117
Product Regulatory Compliance Markings ................................................................ 117
Electromagnetic Compatibility Notices .............................................................................. 118
FCC Verification Statement (USA) ............................................................................ 118
Industry Canada (ICES-003) ..................................................................................... 119
Europe (CE Declaration of Conformity) ..................................................................... 120
VCCI (Japan) ............................................................................................................ 120
BSMI (Taiwan) .......................................................................................................... 120
Korean Compliance (RRL) ........................................................................................ 120
CNCA (CCC-China) .................................................................................................. 121
Regulated Specified Components ............................................................................. 121
Restriction of Hazardous Substances (RoHS) Compliance .............................................. 122
End-of-Life / Product Recycling ......................................................................................... 122
Appendix G: Warranty ............................................................................................123
Limited Warranty for Intel® Chassis Subassembly Products ............................................ 123
Appendix H: Installation/Assembly Safety Instructions .....................................127
English ............................................................................................................................... 127
Deutsch ............................................................................................................................. 129
xvi Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Français .............................................................................................................................131
Español ..............................................................................................................................133
Italiano ...............................................................................................................................136
Appendix I: Safety Information .............................................................................139
English ...............................................................................................................................139
Server Safety Information ..........................................................................................139
Safety Warnings and Cautions ..................................................................................139
Intended Application Uses .........................................................................................140
Site Selection .............................................................................................................140
Equipment Handling Practices ..................................................................................140
Power and Electrical Warnings ..................................................................................141
System Access Warnings ..........................................................................................142
Rack Mount Warnings ...............................................................................................142
Electrostatic Discharge (ESD) ...................................................................................143
Other Hazards ...........................................................................................................143
Deutsch ..............................................................................................................................144
Sicherheitshinweise für den Server ...........................................................................144
Sicherheitshinweise und Vorsichtsmaßnahmen ........................................................144
Zielbenutzer der Anwendung .....................................................................................145
Standortauswahl ........................................................................................................145
Handhabung von Geräten .........................................................................................145
Warnungen zu Netzspannung und Elektrizität ..........................................................146
Warnhinweise für den Systemzugang .......................................................................147
Warnhinweise für Racks ............................................................................................147
Elektrostatische Entladungen (ESD) .........................................................................148
Andere Gefahren .......................................................................................................148
Français .............................................................................................................................149
Consignes de securite sur le serveur ........................................................................149
Séurité: avertissements et mises en garde ...............................................................149
Domaines d’utilisation prévus ....................................................................................150
Sélection d’un emplacement .....................................................................................150
Pratiques de manipulation de l’équipement ...............................................................151
Alimentation et avertissements en matiére d’électricité .............................................151
Avertissements sur le cordon d’alimentation .............................................................152
Avertissements sur l’accés au systéme .....................................................................152
Avertissements sur le montage en rack ....................................................................153
Décharges électrostatiques (ESD) ............................................................................154
Autres risques ............................................................................................................154
Périphériques laser ....................................................................................................155
Español ..............................................................................................................................155
Información de seguridad del servidor ......................................................................155
Advertencias y precauciones sobre seguridad ..........................................................155
Aplicaciones y usos previstos ....................................................................................156
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide xvii
Seleccién de la ubicación .......................................................................................... 156
Manipulacién del equipo ........................................................................................... 157
Advertencias de alimentacién y eléctricas ................................................................ 157
Advertencias sobre el cable de alimentación ............................................................ 157
Advertencias el acceso al sistema ............................................................................ 158
Advertencias sobre el montaje en bastidor ............................................................... 159
Descarga electrostática (ESD) .................................................................................. 159
Otros riesgos ............................................................................................................. 160
xviii Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
List of Tables
Table 1. Server System References .........................................................................................1
Table 2. Intel
Table 3. NIC LED Descriptions ...............................................................................................12
Table 4. Setup Menu Key Use ................................................................................................80
Table 5. Power Supply Output Capability ................................................................................87
Table 6. System Environmental Specifications .......................................................................88
Table 7. Resetting the System ................................................................................................89
Table 8. LED Information ........................................................................................................98
Table 9. POST Error Beep Codes ...........................................................................................98
Table 10. Error Beep Codes Generated by Intel
Table 11. POST Progress Code LED Example .....................................................................105
Table 12. Diagnostic LED POST Code Decoder ...................................................................106
Table 13. Product Regulatory Compliance Markings ............................................................117
®
Server System SR1550AL Feature Summary ...................................................4
®
Remote Management Module ..................99
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide xix
xx Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
1 Server System References
If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources.
Table 1. Server System References
For this information or
software
For in-depth technical information about the server chassis, including sub-system overviews and mechanical drawings
For in-depth technical information about the server board, including board layout, connector pin-outs, timing information, mechanical drawings and LED information
For basic BIOS settings and chipset information
For in-depth BIOS information
For in-depth firmware information on the Baseboard Management Controller (BMC)
For in-depth information
on Intel Technology
I/O Acceleration
Use this Document or Software
®
Intel
Server Chassis SR1550 Technical Product Specification
Found at: http://support.intel.com/support/motherboards/server/chassis/
SR1550/
®
Intel
Server Board S5000PAL Technical Product Specification
Found: http://support.intel.com/support/motherboards/server/S5000PAL/
®
Intel
5000 Series Chipsets Server Board Family Datasheet
Found: http://support.intel.com/support/motherboards/server/S5000PAL/
®
S5000 Server Board Family Server BIOS External Product
Intel Specification
Found: available to order by contacting your Intel field representative; Intel reference number 19953
ESB2 Baseboard Management Controller Core External Product Specification for the Intel
Found: available to order by contacting your Intel field representative; Intel reference number 19692.
Intel
I/O Acceleration Technology Improves Intel Server Platform
Network Performance, Reliability, and Efficiency whitepaper
Found: available from your Intel field representative
®
S5000 Server Board Family
If you just received this product and need to install it
For virtual system tours and interactive repair information
Intel® Integrated Server System SR1550AL Quick Start User's Guide
Found: in the product box
A link to the SMaRT Tool is available under "Other Resources" at the right side of the screen at
http://support.intel.com/support/motherboards/server/chassis/ SR1550
Table 1. Server System References
For this information or
software
Accessories or other Intel server products
Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product
To make sure your system falls within the allowed power budget
For software to manage your Intel
server
For diagnostics test software
Use this Document or Software
Spares and Configuration Guide Found: available from your Intel field representative or on the
Server Configurator Tool at http://indigo.intel.com/ serverconfiguratortool/default.aspx
Tested HardwareOperating Systems List Found: http://support.intel.com/support/motherboards/server/S5000PAL/
Power Budget Tool Found: http://support.intel.com/support/motherboards/server/S5000PAL/
Intel
System Management Software Found: http://support.intel.com/support/motherboards/server/S5000PAL/
Diagnostics Found: http://support.intel.com/support/motherboards/server/S5000PAL/
2 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
2 Server System Features
This chapter briefly describes the main features of the server system. This chapter provides a illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system.
TP02211
Figure 1. Intel
®
Integrated Server System SR1550AL
Table 2 summarizes the features of the server system.
®
Table 2. Intel
Feature Description
Server System SR1550AL Feature Summary
Dimensions
1.700 inches (43.2mm) high
16.930 inches (430.0mm) wide
25.76 inches (654.4mm) deep
37pounds (16.8 kg) - base chassis weight
Server Board Intel
Processor Support for up to two Dual-Core Intel
Memory Eight DIMM slots supporting stacked DDR2 533/667 MHz
Server Board S5000PAL
sequence
FBDIMM memory
Xeon® processors 5000
Support for up to 32 GB DDR2 533/667 MHz FBDIMM memory
Chipset Intel
Peripheral Interfaces External connections:
5000P chipset, consisting of:
®
Intel
Intel
5000P Memory Controller Hub (MCH)
®
6321ESB I/O Controller Hub
Stacked PS/2* ports for keyboard and mouse
RJ45 Serial B port
Two RJ45 NIC connectors for 10/100/1000 Mb connections
Two USB 2.0 ports
Internal connections:
One USB port header, which supports two USB 2.0 ports
One DH10 Serial A header
Six Serial ATA 150 connectors with integrated RAID 0/1
support
One ATA-100 44-pin connector for optical drive support
SSI-compliant 24-pin control panel header
SSI-compliant 24-pin main power connector, supporting the
ATX-12V standard on the first 20 pins
I/O Controll National Semiconductor* PC87427 controller
Video On-board ATI* ES1000 video controller with 16 MB DDR SDRAM
LAN Intel
Expansion Capabilities
82563EB dual port controller for 10/100/1000 Mbit/sec Ethernet LAN connectivity
One low profile riser slot supporting 1U PCI Express* riser
cards
One full height riser slot supporting 1U PCI-X* and PCI
Express* riser cards
Hard Drives
4 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Up to eight 2.5 inch hot-swap SATA / SAS drives
Table 2. Intel® Server System SR1550AL Feature Summary
Feature Description
Peripherals
Control Panel (dependent on option selected)
LEDs and displays (dependent on option selected)
Slimline bay for IDE optical drive
PCI riser card bracket
Standard control panel
Intel
Local Control Panel
Mini control panel
With standard control panel:
NIC1 Activity
NIC2 Activity
Power / Sleep
System Status
System Identification
Hard Drive Activity
With Intel
Local Control Panel:
NIC1 Activity
NIC2 Activity
Power / Sleep
System Status
System Identification
Hard Drive Activity
LCD Display
Power Supply Up to two 650W power supply modules
Fans
Six 4-pin fan headers supporting two processor fans, and four
system fans
Dedicated non-redundant power supply fan (one per module)
USB
One front panel USB port
One internal USB header providing two USB ports
System Management Intel
System Management Software
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide 5
Chassis Component Identification
This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components.
Internal Components
F
E
D
C
B
A
P
O
A. Rack Handle I. PCI Riser Assembly B. Slimline Optical Drive Bay (Optical Drive
Shown)
C. SR1550ALSAS RAID Battery Pack
(Optional) D. Power Distribution Board L. Bridge Board E. Power Supply Air Duct M. Mid-plane Board (Active Shown) F. Power Supply Filler (Second Power Supply
if Installed) G. Power Supply Module O. Rack Handle H. Server Board P. Hard Drive Bays
J. Processor Air Duct
K. Fan Assembly
N. Mini Control Panel Bay
G
H
I
J
K
L
M
N
TP02212
Figure 2. ChassisComponents
6 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Server Board Connector and Component Locations
QQ
OO NN
GG
DD CC
PP
KK
HH
FF EE
BB AA
B
A
MM
LL
JJ
II
Z
Y
X
C
W
V UST
F
ED
I
G
H
J
K L
M
N
O
P
Q
R
TP02071
Figure 3. Server Board Connector and Component Locations
A. BIOS Bank Select Jumper B. Intel® 6321ESB IO Controller Hub C. I/O Expansion Module Connector
D. POST Code Diagnostic LEDs E. Intel
®
Adaptive Slot - Full Height F. PCI Express* Riser Slot - Low
Profile
G. System Identification LED - Blue H. Back Panel I/O Ports I. Status LED - Green/Amber
J. Serial B Configuration Jumper K. System Fan 4 Header L. System Fan 3Header
M. DIMM Sockets N. Intel
®
5000P MCH O. Processor 1 Socket
P. Processor 2 Socket Q. Processor Fan 1 Header R. Voltage Regulator Heat Sink
S. Processor Fan 2 Header T. Bridge Board Connector U. ATA-100 Optical Drive Connector
(Power + IO)
V. System Fan 2 Header W. CPU Power Connector X. Main Power Connector
Y. Battery Z. Power Supply Management
AA. Dual Port USB 2.0 Header
Connector
BB. System Fan 1 Header CC. 24-pin SSI Control Panel
Connector
DD. SATA Port 0
EE. SATA Port 1 FF. SATA Port 2 GG. SATA Port 3
HH. SATA Port 4 II. SATA Port 5 JJ. SATA SW RAID 5 Activation Key
Connector
KK. Intel
NN. 3-pin IPMB Header OO. Intel
QQ. Intel
®
Remote Management
Module (RMM) Connector
®
RMM NIC Connector
LL. System Recovery Jumpers MM. Chassis Intrusion Switch Header
®
Local Control Panel Header PP. Serial A Header
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide 7
Configuration Jumpers
BIOS Select
J3H1
3
3
1-2: Force Lower Bank
2-3: Normal Operation (Default)
TP02087
Jumper Name Jumper Purpose
BIOS Select If pins 1-2 are jumpered, the BIOS in the lower bank will be selected
on the next reset. These pins should be jumpered on 2-3 for normal operation.
Figure 4. BIOS Select Jumper
8 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
BMC Force
Update Mode
2
3
J1D2
Password Reset
2
3
J1D3
Clear CMOS
2
3
J1D1
Disable
Enable
TP02080
Jumper Name Jumper Purpose
CMOS Clear If pins 2-3 are jumpered, the CMOS settings will be cleared on the
next reset. These pins should be jumpered on 1-2 for normal operation.
Password Clear If pins 2-3 are jumpered, administrator and user passwords will be
cleared on the next reset. These pins should be jumpered on 1-2 for normal operation.
BMC Force Update Mode If pins 2-3 are jumpered, BMC Force Update Mode is enabled.
These pins should be jumpered on 1-2 for normal operation.
Figure 5. Recovery Jumpers
Intel® Server System SR1550AL/SR1550ALSAS User’s Guide 9
Intel® Light Guided Diagnostics
The server board contains diagnostic LEDs to help you identify failed and failing components, and to help you identify the server from among several servers. Except for the ID LED, the status LED, and the 5V standby LED, the LEDs turn on (amber) only if a failure occurs.
A
POST
Code LEDs
D
E
N
CPU 2
Socket
C
Light Guided Diagnostics Legend
through
A
F
DIMM A1
DIMM A2
DIMM B1
DIMM B2
JH K
DIMM C1
DIMM C2
DIMM D1
DIMM D2
I
G
L
M
CPU 1
Socket
A. POST Code LEDs B. ID LED C. Status LED D. DIMM A1 Fault E. DIMM A2 Fault F. DIMM B1 Fault G. DIMM B2 Fault H. DIMM C1 Fault I. DIMM C2 Fault J. DIMM D1 Fault K. DIMM D2 Fault L. CPU 1 Fault M. CPU 2 Fault N. 5V Standby
N
B
AF000644
Figure 6. Light Guided Diagnostic LEDs
10 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
Loading...
+ 152 hidden pages