Intel SR1520ML - Server System - 0 MB RAM User Manual

Intel® Server System SR1520ML User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Intel Order Number E17409-004
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. All Rights Reserved
ii Intel® Server System SR1520ML User’s Guide
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the
®
Server Deployment Toolkit 2.0 CD and/or at
Intel
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment T oolkit 2.0 CD
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel rendez-vous sur le site
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit 2.0 CD ou bien
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel
http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
®
Server Deployment Toolkit 2.0 CD y/o en
Intel® Server System SR1520ML User’s Guide iii
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm
Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
Warnings
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
上的 Intel
/
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
iv Intel® Server System SR1520ML User’s Guide
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1520ML User’s Guide v
vi Intel® Server System SR1520ML User’s Guide
Contents
Safety Information .....................................................................................................iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Warnings ............................................................................................................................... iv
Preface .....................................................................................................................xvii
About this Manual ...............................................................................................................xvii
Manual Organization ...........................................................................................................xvii
Product Contents ...............................................................................................................xviii
Server System References ................................................................................................. xix
Chapter 1: Server System Features ..........................................................................1
External Component Identification .........................................................................................3
System Front Panel .......................................................................................................3
System Rear ..................................................................................................................6
Peripheral Devices ........................................................................................................7
Internal Components .............................................................................................................8
Server Board Connectors ..............................................................................................8
Configuration Jumpers ................................................................................................10
SATA RAID Support ............................................................................................................11
Rack and Cabinet Mounting ................................................................................................11
Hardware Requirements ......................................................................................................11
Processor ....................................................................................................................12
Memory ........................................................................................................................12
Chapter 2: Hardware Installations and Upgrades .................................................13
Before You Begin .................................................................................................................13
Tools and Supplies Needed ........................................................................................13
System References .....................................................................................................13
Removing and Installing the Server Cover ..........................................................................14
Removing the Server System Cover ...........................................................................14
Installing the Server System Cover .............................................................................15
Installing and Removing a Hard Drive .................................................................................15
Installing a Hard Drive .................................................................................................16
Removing a Hard Drive ...............................................................................................18
Installing an Intel
Installing and Removing the PCI Riser Assembly ...............................................................21
Removing the PCI Riser Assembly .............................................................................21
Intel® Server System SR1520ML User’s Guide vii
®
Z-U130 Value Solid State Drive .............................................................20
Installing the PCI Riser Assembly ............................................................................... 22
Removing and Installing the PCI Riser Card ....................................................................... 24
Removing the PCI Riser Card ..................................................................................... 24
Installing a PCI Riser Card .......................................................................................... 25
Installing and Removing a PCI Add-in Card ........................................................................ 26
Installing a PCI Add-in Card ........................................................................................ 26
Removing a PCI Add-in Card ...................................................................................... 27
Removing and Installing the Processor Air Duct ................................................................. 28
Removing the Processor Air Duct ............................................................................... 28
Installing the Processor Air Duct ................................................................................. 29
Installing and Removing Memory ........................................................................................ 29
Memory Population Rules ........................................................................................... 30
Installing DIMMs .......................................................................................................... 30
Removing DIMMs ........................................................................................................ 32
Replacing the Processor ..................................................................................................... 33
Removing the Heat Sink and Processor ..................................................................... 33
Installing the Processor ............................................................................................... 35
Installing the Heat Sink ............................................................................................... 36
Replacing the Power Supply ............................................................................................... 37
Replacing the Fans .............................................................................................................40
Replacing a Blower Fan .............................................................................................. 41
Replacing a Memory Cooling Fan ............................................................................... 44
Replacing a Server Board ................................................................................................... 46
Removing the Server Board ........................................................................................ 46
Installing the Server Board .......................................................................................... 48
Replacing the Front Panel Board ........................................................................................ 50
Replacing the CMOS Battery .............................................................................................. 53
Installing and Removing the Rack Handles ......................................................................... 56
Installing the Rack Handles ......................................................................................... 56
Removing the Rack Handles ....................................................................................... 57
Chapter 3: Server Utilities ........................................................................................59
Using the BIOS Setup Utility ............................................................................................... 59
Starting Setup ............................................................................................................. 59
If You Cannot Access Setup ....................................................................................... 59
Setup Menus ............................................................................................................... 59
Upgrading the BIOS ............................................................................................................ 61
Preparing for the Upgrade ........................................................................................... 61
Upgrading the BIOS .................................................................................................... 62
Recovering the BIOS ........................................................................................................... 62
Clearing the Password ........................................................................................................ 64
Performing an iBMC Force Update ..................................................................................... 66
Using the iBMC Boot Block Write Protect Jumper (J1A4) ................................................... 68
Appendix A: Technical Reference ...........................................................................71
viii Intel® Server System SR1520ML User’s Guide
Cable Routing ......................................................................................................................71
Power Cable Routing ...................................................................................................72
Data Cable Routing .....................................................................................................73
600 W Power Supply Input Voltages ...................................................................................74
600 W Power Supply Output Voltages ................................................................................74
System Environmental Specifications ..................................................................................75
Appendix B: Installation/Assembly Safety Instructions ....................................... 77
English .................................................................................................................................77
Deutsch ................................................................................................................................79
Français ...............................................................................................................................81
Español ................................................................................................................................83
Italiano .................................................................................................................................86
Appendix C: Troubleshooting .................................................................................89
Resetting the System ...........................................................................................................89
Problems following Initial System Installation ......................................................................90
First Steps Checklist ....................................................................................................90
Hardware Diagnostic Testing ...............................................................................................90
Verifying Proper Operation of Key System Lights .......................................................91
Confirming Loading of the Operating System ..............................................................91
Specific Problems and Corrective Actions ...........................................................................91
Power Light Does Not Light .........................................................................................92
No Characters Appear on Screen ...............................................................................92
Characters Are Distorted or Incorrect ..........................................................................93
System Cooling Fans Do Not Rotate Properly ............................................................93
Drive Activity Light Does Not Light ..............................................................................94
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ...............................94
Cannot Connect to a Server ........................................................................................94
Problems with Network ................................................................................................95
System Boots when Installing PCI Card ......................................................................95
Problems with Newly Installed Application Software ...................................................96
Problems with Application Software that Ran Correctly Earlier ...................................96
Devices are not Recognized under Device Manager (Microsoft* Windows* Operating
System) ............................................................................................................97
Hard Drive(s) are not Recognized ...............................................................................97
Bootable CD-ROM Disk Is Not Detected .....................................................................97
Appendix D: Getting Help ........................................................................................99
World Wide Web ..................................................................................................................99
Telephone ............................................................................................................................99
Appendix E: Warranty ............................................................................................ 103
Limited Warranty for Intel® Chassis Subassembly Products ............................................103
Appendix F: Safety Information ............................................................................107
Intel® Server System SR1520ML User’s Guide ix
English ............................................................................................................................... 107
Server Safety Information ......................................................................................... 107
Safety Warnings and Cautions .................................................................................. 107
Intended Application Uses ........................................................................................ 108
Site Selection ............................................................................................................ 108
Equipment Handling Practices .................................................................................. 108
Power and Electrical Warnings ................................................................................. 109
System Access Warnings ......................................................................................... 110
Rack Mount Warnings ............................................................................................... 110
Electrostatic Discharge (ESD) ................................................................................... 111
Other Hazards ........................................................................................................... 111
Deutsch ............................................................................................................................. 112
Sicherheitshinweise für den Server ........................................................................... 112
Sicherheitshinweise und Vorsichtsmaßnahmen ....................................................... 112
Zielbenutzer der Anwendung .................................................................................... 113
Standortauswahl ....................................................................................................... 113
Handhabung von Geräten ......................................................................................... 113
Warnungen zu Netzspannung und Elektrizität .......................................................... 114
Warnhinweise für den Systemzugang ....................................................................... 115
Warnhinweise für Racks ........................................................................................... 115
Elektrostatische Entladungen (ESD) ......................................................................... 116
Andere Gefahren ....................................................................................................... 116
Français ............................................................................................................................. 117
Consignes de securite sur le serveur ........................................................................ 117
Séurité: avertissements et mises en garde ............................................................... 117
Domaines d’utilisation prévus ................................................................................... 118
Sélection d’un emplacement ..................................................................................... 118
Pratiques de manipulation de l’équipement .............................................................. 119
Alimentation et avertissements en matiére d’électricité ............................................ 119
Avertissements sur le cordon d’alimentation ............................................................. 120
Avertissements sur l’accés au systéme .................................................................... 120
Avertissements sur le montage en rack .................................................................... 121
Décharges électrostatiques (ESD) ............................................................................ 122
Autres risques ........................................................................................................... 122
Périphériques laser ................................................................................................... 123
Español ............................................................................................................................. 123
Información de seguridad del servidor ...................................................................... 123
Advertencias y precauciones sobre seguridad ......................................................... 123
Aplicaciones y usos previstos ................................................................................... 124
Seleccién de la ubicación .......................................................................................... 124
Manipulacién del equipo ........................................................................................... 125
Advertencias de alimentacién y eléctricas ................................................................ 125
Advertencias sobre el cable de alimentación ............................................................ 125
Advertencias el acceso al sistema ............................................................................ 126
x Intel® Server System SR1520ML User’s Guide
Advertencias sobre el montaje en bastidor ...............................................................128
Descarga electrostática (ESD) ..................................................................................128
Otros riesgos .............................................................................................................129
Appendix G: Regulatory and Compliance Information .......................................131
Product Regulatory Compliance ........................................................................................131
Product Safety Compliance .......................................................................................131
Product EMC Compliance - Class A Compliance ......................................................132
Certifications/Registrations/Declarations ...............................................................133
Product Regulatory Compliance Markings ................................................................133
Electromagnetic Compatibility Notices ..............................................................................136
FCC Verification Statement (USA) ............................................................................136
Industry Canada (ICES-003) .....................................................................................137
Europe (CE Declaration of Conformity) .....................................................................137
VCCI (Japan) .............................................................................................................137
BSMI (Taiwan) ...........................................................................................................137
Korean Compliance (RRL) ........................................................................................138
Regulated Specified Components .............................................................................138
Product Ecology Requirement End-of-L
ife/Product Recycling .........................................................................................140
s .........................................................................................139
Intel® Server System SR1520ML User’s Guide xi
xii Intel® Server System SR1520ML User’s Guide
List of Tables
Table 1. Server System References ...................................................................................... xix
Table 2. Feature Summary ........................................................................................................2
Table 3. NIC LED Descriptions .................................................................................................6
Table 4. Setup Menu Key Use ................................................................................................60
Table 5. Power Supply Output Capability ................................................................................74
Table 6. System Environmental Specifications .......................................................................75
Table 7. Resetting the System ................................................................................................89
Table 8. Product Regulatory Compliance Markings ..............................................................133
Intel® Server System SR1520ML User’s Guide xiii
xiv Intel® Server System SR1520ML User’s Guide
List of Figures
Figure 1. Intel® Server System SR1520ML............................................................................... 1
Figure 2. Front Controls and LEDs............................................................................................ 5
Figure 3. Back Panel Connectors.............................................................................................. 6
Figure 4. Optional Peripherals................................................................................................... 7
Figure 5. System Components.................................................................................................. 8
Figure 6. Server Board Connector Locations............................................................................ 9
Figure 7. Configuration Jumpers............................................................................................. 10
Figure 8. Removing the Server System Cover........................................................................ 14
Figure 9. Installing the Server System Cover.......................................................................... 15
Figure 10. Removing Drive Carrier from the Server System................................................... 16
Figure 11. Installing The Hard Drive in the Drive Carrier ........................................................ 17
Figure 12. Installing Drive Assembly....................................................................................... 18
Figure 13. Removing Drive Carrier.......................................................................................... 19
Figure 14. Installing the Drive Carrier...................................................................................... 20
Figure 15. Removing PCI Riser Assembly.............................................................................. 22
Figure 16. Installing PCI Riser Assembly into the Server System........................................... 23
Figure 17. Removing Riser Card from Riser Assembly........................................................... 24
Figure 18. Installing Riser Card onto Riser Assembly............................................................. 25
Figure 19. Installing an Add-In Card........................................................................................ 26
Figure 20. Removing an Add-In Card...................................................................................... 27
Figure 21. Removing the Processor Air Duct.......................................................................... 28
Figure 22. Installing the Processor Air Duct............................................................................ 29
Figure 23. Installing Memory DIMMs....................................................................................... 31
Figure 24. Removing Memory DIMMs..................................................................................... 32
Figure 25. Opening the Processor Socket Handle.................................................................. 34
Figure 26. Opening the Load Plate ......................................................................................... 34
Figure 27. Removing the Processor........................................................................................ 35
Figure 28. Installing the Processor.......................................................................................... 36
Figure 29. Installing the Heat Sink .......................................................................................... 37
Figure 30. Disconnecting Power Cables ................................................................................. 38
Figure 31. Removing Power Supply........................................................................................ 39
Figure 32. Installing Power Supply Module............................................................................. 40
Figure 33. Disconnecting Cables ............................................................................................ 41
Figure 34. Removing Bracket and Fans.................................................................................. 42
Figure 35. Removing Fan from Fan Bracket ........................................................................... 43
Figure 36. Disconnecting Memory Cooling Fan Cable............................................................ 44
Figure 37. Connecting Memory Cooling Fan Cable ................................................................ 45
Figure 38. Removing the Server Board................................................................................... 47
Figure 39. Installing the Server Board..................................................................................... 48
Figure 40. Connecting Cables to Server Board....................................................................... 50
Figure 41. Removing Front Panel Board................................................................................. 52
Figure 42. Installing Front Panel Board................................................................................... 53
Intel® Server System SR1520ML User’s Guide xv
Figure 43. Removing the CMOS Battery ................................................................................ 55
Figure 44. Installing the Rack Handle..................................................................................... 56
Figure 45. Removing the Rack Handle................................................................................... 57
Figure 46. BIOS Recovery Mode Jumper in Recovery Position ............................................. 63
Figure 47. Password Clear Jumper in Clear Password Position ............................................ 64
Figure 48. CMOS Clear Jumper in Clear CMOS Position ...................................................... 65
Figure 49. MiBMC Force Update Jumper in the Write Enable Position.................................. 67
Figure 50. iBMC Boot Block Write Protect Jumper (J1A4) ..................................................... 68
Figure 51. Power Cable Routing............................................................................................. 72
Figure 52. Data Cable Routing ............................................................................................... 73
xvi Intel® Server System SR1520ML User’s Guide
Preface
About this Manual
Thank you for purchasing and using the Intel® Server System SR1520ML. This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http://
support.intel.com/support/motherboards/server/
Manual Organization
Chapter 1 provides an overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.
X38ML/.
Chapter 2 provides instructions on adding and replacing components. Us e this chap ter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the T echnical Product Specifications for the server board and chassis. See T ab le 1 on page xix for a link to the Technical Product Specifications.
At the back of this manual, you will find technical specifications, troubleshooting tips, regulatory information, complete safety information, “getting help” information, and the warranty.
Intel® Server System SR1520ML User’s Guide xvii
Product Contents
Your Intel® Server System SR1520ML ships with the following items.
Two Intel
One 600-watt power supply module, installed in the server chassis
One power cable to connect to AC power (North America only)
Four cooling fans, with attached cables, installed in the server system:
Two memory cooling fans — Two system blower fans
Two passive heat sinks, in the server system product box
Two hard drive brackets, in the server system product box
Two PCI Express* x16 risers, installed in the server system
Two processor/memory air ducts
Rack handles, in the server system product box
One front control panel board with front panel controls for two server boards,
installed in the server system
One basic slide rail kit, in a separate box
®
Server Boards X38ML installed in the server chassis
Cables:
Two SATA cables, installed in the server system — Two front pa
One front panel Y-cable, installed in the server system
Intel
Intel
®
Server Deployment To olkit 2.0 CD that contains documentation, drivers, and
utilities
®
System Management Software 2.0 CD set (two CDs)
nel/Z-U130 USB Y-cables, installed in the server system
xviii Intel® Server System SR1520ML User’s Guide
Server System References
If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources.
Table 1. Server System References
For this Information or
Software
Technical information about the server chassis, including sub-system overviews and mechanical drawings
Technical information about the server board, including board layout, connector pin-outs, timing information, mechanical drawings and LED information
Technical information about the server system, including connector pin­outs, timing information, mechanical drawings and LED information
If you just received this product and need to install it
Accessories or other Intel server products
Use this Document or Software
Intel® Server System SR1520MLTechnical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML/
®
Intel
Server Board X38ML Technical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML
®
Intel
Server System SR1520ML Technical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML/
®
Intel
Server System SR1520ML Quick Start User's Guide
In the product box
Spares and Configuration Guide Available from your Intel field representative or on the Server
Configurator Tool at http://indigo.intel.com/serverconfiguratortool/ default.aspx
Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product
Processor and DIMMs that have been tested with this produc
For drivers Search for the word “driver” (for an extensive list of available
For firmware and BIOS updates, or for BIOS recovery
Intel® Server System SR1520ML User’s Guide xix
Tested Hardware and Operating Systems List At http://support.intel.com/support/motherboards/server/X38ML/
See http://support.intel.com/support/motherboards/server/X38ML/
drivers) Search for “operating system driver” (for operating system drivers)
Firmware Updates
Table 1. Server System References
For this Information or
Software
For software to manage your Intel® server
To make sure your system falls within the allowed power budget
For diagnostics test software
Use this Document or Software
®
Intel
System Management Software Software 2.0
At http://support.intel.com/support/motherboards/server/X38ML/
Search for the phrase “Power Budget Tool” At http://support.intel.com/support/motherboards/server/X38ML/
Search for the word “Diagnostics”
xx Intel® Server System SR1520ML User’s Guide
1 Server System Features
This chapter briefly describes the main features of the server system. It prov ides product illustrations, a list of the server system features, and diagrams that show the location of important components and connections.
®
The Intel installed in it. Each server board operates as a fully functioning server system with it’s own control panel, BIOS setup configuration, processor, memory, drives, add-in card, keyboard/mouse, and video monitor. These items are not shared by the two server boards. The two server boards share the chassis and power supply.
Since the server boards function independently, the processor and DIMM rules apply to each board independently. The two server boards do not need to use identical processors or DIMMs.
Intel® Server System SR1520ML User’s Guide 1
Server System SR1520ML ships with two Intel® Server Boards X38ML
Figure 1. Intel
®
Server System SR1520ML
Table 2 summarizes the features of the server system.
Table 2. Feature Summary
Feature Description
Dimensions
1.67 inches high (42.42 mm)
16.93 inches wide (430.02 mm)
20 inches deep (508.00 mm)
Server board Intel
Processors Processor and Front Side Bus (FSB) support
®
Server Board X38ML. Two per system.
The system supports one processor on each server board. For
supported Intel processors, see http://support.intel.com/
support/motherboards/server/X38ML
Supports 800/1066/1333 MHz FSB
Memory
Four DIMM sockets per server board supporting stacked
DDR2 667/800 MHz unbuffered ECC memory or non-ECC memory
Each server board has two memory channels with two DIMM
sockets per channel
Support for up to 8 GB of total system memory on each server
board
Chipset Intel® X38 chipset on each server board, consisting of:
®
Intel
Intel
Peripheral Interfaces External connections on each server board:
X38 Memory Controller Hub (MCH)
®
I/O Controller Hub (ICH9R)
DB9 Serial A port
Two RJ45 NIC connectors for 10/100/1000 Mb connections
Two USB 2.0 ports
VGA header for video output
Internal connections on each server board:
One USB port header, which supports two USB 2.0 ports
One DH10 Serial B header
Four Serial ATA connectors with embedded RAID 0/1/10
support
Video Each server board has an on-board video controller with 32 MB
LAN Two Intel® 10/100/1000 82573E Gigabit Ethernet controllers on
Expansion capabilities One low-profile PCI Express* riser card for each server board.
Hard drives
2 Intel® Server System SR1520ML User’s Guide
DDR2 667 video memory
each server board
Each supports one low-profile x1, x4, x8, or x16 adapter.
Support for up to two 2.5-inch drives. SATA (3.0 Gb/s) support
Support for two Intel
®
Z-U130 Value Solid State Drives
Table 2. Feature Summary
Feature Description
Control panel Each server board has a control panel. Each control panel includes:
One USB port
Power / sleep button
Reset button
Power Supply LED
Status LED
Hard drive activity LED
NIC1 activity LED
NIC2 activity LED
Power supply One 600-watt power supply module
Fans
Two memory cooling fans. Each server board controls one fan.
Two system blower fans. Each server board controls one fan.
USB
Each server board has two USB ports on the back panel
Each server board has one internal USB header, which
supports two USB ports
System management Intel® System Management 2.0 Software
External Component Identification
This section helps you identify the components of your server system. If you are near the system, you can also use the quick reference label on the inside of the chassis cover to assist in identifying components.
System Front Panel
Each server board has its own control panel at the front of the server system. Each control panel includes the following buttons and LEDs.
Intel® Server System SR1520ML User’s Guide 3
A B C D
G
Item Feature Description
Front Panel Connector
A USB connector 2.0 port, 4-pin connectors
Front Panel Buttons and LED Indicators
E
F
AF002495
B Server board power /
sleep button
C Power Supply LED Green LED for system power supply status
Press to turn the system power on or off
LED State Power State
Green On DC Power is ready to be
applied to the board
Green Blink Board is in sleep state S1
Off DC Power supply is in the
‘Off’ state
4 Intel® Server System SR1520ML User’s Guide
Item Feature Description
D System status / fault
LED
E LAN1, LAN 2 Status
LEDs
Green / amber LED for system status.
LED State System State
Green On Board is ‘ON’ with no alarm
Green Blink Board is ‘ON’ but degraded:
some CPU fault, DIMM killed
Amber On Critical alarm: Critical power
module failure, critical fan failure, voltage (power supply), Voltage and thermal fault
Amber Blink Non-Critical failure: Non-
critical power and voltage
Off Board is off with no alarm
Green LEDs that show the status of each LAN port
LED State LAN State
Green Off Idle
Green On LAN link / no access
Green Blink Active
F Hard drive activity
LED
G System reset button Press to reset the system
Green LED that indicates hard drive activity
LED State Drive State
Green blink Drive is active
Off Drive is not active
Figure 2. Front Controls and LEDs
Intel® Server System SR1520ML User’s Guide 5
System Rear
Except for the shared AC power supply, each server board has its own back panel connectors.
A
A. AC power connector (one per
system)
B. PCI Express* add-in card slot
location (one for each server board)
C. NIC 1 (10 / 100 / 1000 Mb) (one for
each server board)
D. Video connector (one for each server
board)
B B
E
D
Figure 3. Back Panel Connectors
C
D
G
F
E. Serial port (one for each server
board)
F. NIC 2 (10 / 100 / 1000 Mb) (one for
each server board)
G. USB ports 0-1 (one sets of two ports
for each server board)
E
C
G
F
AF002496
The LEDs at the right and left of each NIC provide the following information.
Table 3. NIC LED Descriptions
LED LED State Description
Left Off No network connection
Solid amber Network connection in place
Blinking amber Transmit/receive activity
Right Off 10 Mbps connection (if left LED is on or blinking)
Solid amber 100 Mbps connection
Solid green 1000 Mbps connection
6 Intel® Server System SR1520ML User’s Guide
Peripheral Devices
The server system provides locations for installing up to two fixed 2.5-inch SATA hard drives and up to two Intel
®
Z-U130 Value Solid State Drive (Intel® VSSD). Each server board controls one of each of these drives. No optical or floppy drive bays are available, but these devices are supported through an external USB connection. The drives must be purchased separately. The following figure shows the available options.
B
.
A
AF002494
A. Two 2.5-inch hard drive bays, stacked on top of each other B. Two Intel® Z-U130 Value Solid State Drive bays
Figure 4. Optional Peripherals
For instructions on installing a hard drive, see “Installing and Removing a Hard Drive” on
page 15.
For instructions on installing the Intel titled Intel
®
Z-U130 Value Solid State Drive Mounting Kit Installation Guide for Intel®
®
Z-U130 Value Solid State Drive, see the document
Server Systems.
Note: Drives can consume up to 17 watts of power each. Drives must be specified to run at a
maximum ambient temperature of 45
®
Note: The Intel
Server System SR1520ML does not support all Serial ATA (SATA) hard drives.
o
C.
See “Server System References” on page xix for an Internet link to a list of supported hardware.
Intel® Server System SR1520ML User’s Guide 7
Internal Components
C
B
D
A
E
H
F
G
AF002493
A. Memory cooling fans (two) E. Power supply B. Processor and memory air duct (two) F. Hard drive bracket (one bracket for two
2.5-inch drives) C. Processor and heat sink (two) G. Front control panel (two) D. PCI add-in card bracket (two) H. System blower fans (two)
Server Board Connectors
The two Intel® Server Boards X38ML have the same connectors / components.
Figure 5. System Components
8 Intel® Server System SR1520ML User’s Guide
W
DCFEAB
G
X
V
U
T
S
H
R
Q
P
O
I
NMKJ
L
AF002498
A. NIC1 RJ45 connector (top) I. Processor socket Q. DIMM socket B1
B. USB port 0 (bottom)
USB port 1 (center)
C. NIC2 RJ45 connector K. System fan 3 S. SATA port 0
D. CMOS battery L. System fan 2 T. SATA port 1
E. Serial A DB9 connector M. System fan 1 U. SATA port 2
F. VGA connector N. Main power connector V. SATA port 3
G. POST LEDs O. DIMM socket A1 W. USB header for USB 2 and 3
H. PCI Express* x16 riser slot P. DIMM socket A2 X. Chassis intrusion header
J. Front panel connector R. DIMM socket B2
Figure 6. Server Board Connector Locations
Intel® Server System SR1520ML User’s Guide 9
Configuration Jumpers
The two Intel® Server Boards X38ML have the same jumpers.
A
B
D
C
E
Callout Location Jumper Name Jumper Purpose
A J1A4 iBMC Boot
Block Write Protect
B J1A2 BIOS
Recovery Mode
C J1A3 CMOS Clear When pins 2-3 are jumpered, the CMOS settings
When pins 2-3 are jumpered, the iBMC boot block is write enabled. When pins 1-2 are jumpered, the iBMC boot block is write protected. Pins 1-2 should be jumpered for normal operation.
When pins 2-3 are jumpered, the BIOS will be recovered on the next boot. Pins 1-2 should be jumpered for normal operation.
will be cleared on the next boot. Pins 1-2 should be jumpered for normal operation.
D J3A1 iBMC Force
Update Mode
E J6B1 Password
Clear
When pins 2-3 are jumpered, the iBMC firmware will be updated on the next boot. Pins 1-2 should be jumpered for normal operation.
When pins 2-3 are jumpered, the administrator and user passwords will be reset on the next boot. Pins 1-2 should be jumpered for normal operation.
Figure 7. Configuration Jumpers
10 Intel® Server System SR1520ML User’s Guide