Intel SBX82 User Manual

Intel® Server Compute Blade SBX82
Installation and User’s Guide
A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies & Products
Order Number C90879-001
1
Disclaimer
Information in this document is provided in connection with Intel. products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products.
Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right.
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel, Pentium, Itanium and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
© Copyright Intel Corporation 2004
2
ii Intel Server Compute Blade SBX82 Installation and User’s Guide
Contents
Safety and regulatory information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
General Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Handling electrostatic discharge-sensitive devices. . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Regulatory specifications and disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Electromagnetic compatibility notices (USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Electromagnetic compatibility notices (International) . . . . . . . . . . . . . . . . . . . . . . . . . xiii
1 Introducing the Intel
Features and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Reliability, availability, and serviceability features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Intel Server Compute Blade SBX82 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Intel Server Compute Blade SBX82 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Major components of the blade server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Related publications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Notices and statements used in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Using power, controls, jumpers, switches, and indicators . . . . . . . . . . . . . . . . . . . . . . . 11
Turning on the blade server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Turning off the blade server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Understanding the control panel and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
System board illustration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Using system board switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Using switch block 2 (SW2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Using Light Path Diagnostics to troubleshoot the system board . . . . . . . . . . . . . . . . . 17
®
Server Compute Blade SBX82 blade server . . . . . . . . . . . . . . . . . 1
3 Installing options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
System reliability considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Handling static-sensitive devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installing and removing the blade server from the SBCE unit . . . . . . . . . . . . . . . . . . . . . . . 20
Opening the blade server cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Removing the blade server bezel assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Installing a SCSI hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Removing a SCSI hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing memory modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing an additional processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Installing an I/O expansion card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Installing a small form-factor expansion card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Installing a standard form-factor expansion card . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
IInstalling the Intel Blade Server SCSI Expansion Module SBESCSI . . . . . . . . . . . . . . . . . 32
Installing a SCSI storage expansion unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Installing a SCSI disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Opening the expansion unit cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Installing an I/O expansion card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Replacing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Completing the installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Installing the blade server bezel assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Closing the blade server cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
iii
Installing the blade server in the SBCE unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Updating your blade server configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Input/output connectors and devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
4 Configuring the blade server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Using the Configuration/Setup Utility program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Starting the Configuration/Setup Utility program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Configuration/Setup Utility menu choices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Using passwords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Using the PXE boot agent utility program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Firmware updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Configuring the Gigabit Ethernet controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Blade server Ethernet controller enumeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Configuring a SCSI RAID array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Using the LSI Logic Configuration Utility program. . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
5 Solving problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Diagnostic tools overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
POST beep code descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
POST error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Troubleshooting charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Memory problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Processor problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Monitor problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Mouse problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Network connection problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Option problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Power problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Service processor problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Light path diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Diagnosing problems using Light Path Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Light Path Diagnostics LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Light Path Diagnostics table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
A Getting help and technical assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Before you call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Using the documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Getting help and information from the World Wide Web . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
iv Intel Server Compute Blade SBX82 Installation and User’s Guide
Safety and regulatory information
W
NOTE
The service procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that you are familiar with the computers, functions, terminology, and service information provided in this manual.
Important Safety Instructions
Read all caution and s afety statements in t his document befo re perfo rming any of the inst ruct io n s. S e e Intel Server Boards and Server Chass is Safety Infor m ation on the Resource CD and/or at http:\\support.intel.com
ichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverp latinen und -Servergehäusen auf der Ressour cen-CD oder unter
http:\\support.intel.com
重要安全指导
.
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。参见 Resou rce CD(资源光盘) / http:\\support.intel.com Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce doc ument avant de suivr e toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site
http:\\support.intel.com
.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de reali zar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chas s is Safety Information en el CD Resource y/o en http:\\support.intel.com
.
上的 I ntel Server Boards and Server
.
v
xx
General Safety
Follow these rules to ensure general safety:
Observe good housekeeping in the area of the machines during and after maintenance.
When lifting any heavy object:
1. Ensure you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly, or twist,when you attempt to lift.
4. Lift by standing or by pushing up with you leg muscles; this action removes the strain from the muscles in your back. Do not attempt to lift any object that weighs more than 16 kg (35lb) or any object that you think is too heavy for you.
Do not perform any action that causes hazards to the customer, or makes the equipment unsafe.
Before you start the machine, ensure that other service representatives and the customer’s personnel are not in a hazardous position.
Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the machine.
Keep your tool case away from walk areas so that other people will not trip over it.
Do not wear loose clothing that can be trapped in the moving parts of a machine. Ensure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it.
Insert the ends of your necktie or scarf inside clothing, or fasten it with a nonconductive clip, approximately 8 centimeters (3 inches) from the end.
Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing.
Remember: Metal objects are good electrical conductors.
Wear safety glasses when you are: hammering, drilling soldering, cutting wire, attaching springs, using solvents, or working in any other conditions that might be hazardous to your eyes.
After service, reinstall all safety shields, guards, labels, and ground wires. Replace any safety device that is worn or defective.
Reinstall all covers correctly before returning the machine to the customer.
Electrical Safety
CAUTION:
Electrical current from power, telephone, and communication cables can be hazardous. To avoid personal injury or equipment damage, disconnect the server system power cords, telecommunication systems, networks, and modems before you open the server covers, unless instructed otherwise in the installation and configuration procedures.
Important: Disconnect all power before performing a mechanical inspection.
Observe the following rules when working on electrical equipment.
Use only approved tools and test equipment. Some hand tools have handles covered with a soft material that does not protect you when working with live electrical currents.
Many customers have rubber floor mats (near their equipment) that contain small conductive fibers to decrease electrostatic discharges. Do not use this type of mat to protect yourself from electrical shock.
vi Intel Server Compute Blade SBX82 Installation and User’s Guide
Find the emergency power-off (EPO) switch, disconnect switch, or electrical outlet in the room. If an electrical accident occurs, you can quickly turn off the switch or unplug the power cord.
Do not work alone under hazardous conditions, or near equipment that has hazardous voltages.
Disconnect all power before:
— Performing a mechanical inspection — Working near power supplies — Removing or installing main units
Before you start to work on the machine, unplug the power cord. If you cannot unplug it, ask the customer to power-off the wall box (that supplies power to the machine) and to lock the wall box in the off position.
If you need to work on a machine that has exposed electrical circuits, observe the following precautions:
— Ensure that another person, familiar with the power-off controls, is near you. Remember:
another person must be there to switch off the power, if necessary.
— Use only one hand when working with powered-on electrical equipment; keep the other
hand in your pocket or behind your back.
— Remember: There must be a complete circuit to cause electrical shock. By observing the
above rule, you may prevent a current from passing through your body.
When using testers, set controls correctly and use the approved probe leads and accessories for that tester.
Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames.
Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of the maintenance information. Use extreme care when measuring high voltages.
Regularly inspect and maintain your electrical hand tools for safe operational condition.
Do not use worn or broken tools and testers.
Never assume that power has been disconnected from a circuit. First, check that it has been powered-off.
Always look carefully for possible hazards in your work area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds.
Do not touch live electrical circuits with the reflective surface of a plastic dental inspection mirror. The surface is conductive; such touching can cause personal injury and machine damage.
When the power is on and power supply units, blowers and fans are removed from their normal operating position in a machine, do not attempt to service the units. This practice ensures correct grounding of the units.
If an electrical accident occurs, use caution:
— Switch power off — Send another person to get help/medical aid
vii
Handling electrostatic discharge-sensitive devices
Any computer part containing transistors or integrated circuits (IC) should be considered sensitive to electrostatic discharge (ESD). ESD damage can occur when there is a difference in charge between objects. Protect against ESD damage by equalizing the charge so that the server, the part, the work mat, and the person handling the part are all at the same charge.
NOTE
Use product-specific ESD procedures when they exceed the requirements noted here.
Make sure that the ESD-protective devices you use have been certified (ISO 9000) as fully effective.
When handling ESD-sensitive parts:
Keep the parts in protective packages until they are inserted into the product.
Avoid contact with other people.
Wear a grounded wrist strap against your skin to eliminate static on your body.
Prevent the part from touching your clothing. Most clothing is insulative and retains a charge even when you are wearing a wrist strap.
Use the black side of a grounded work mat to provide a static-free work surface. The mat is especially useful when handling ESD-sensitive devices.
Select a grounding system, such as those in the following list, to provide protection that meets the specific service requirement.
— Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground. — Use an ESD common ground or reference point when working on a double-insulated or
battery-operated system. You can use coax or connector-outside shells on these systems.
— Use the round ground-prong of the AC plug on AC-operated computers.
NOTE
The use of a grounding system is desirable but not required to protect against ESD damage.
DANGER
Electrical current from power, telephone and communication cables is hazardous.
To avoid a shock hazard:
Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.
Connect all power cords to a properly wired and grounded electrical outlet.
Connect to properly wired outlets any equipment that will be attached to this product.
When possible, use one hand only to connect or disconnect signal cables.
Never turn on any equipment when there is evidence of fire, water, or structural damage.
Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices.
viii Intel Server Compute Blade SBX82 Installation and User’s Guide
xx
xx
To Connect To Disconnect
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
5. Turn device ON.
CAUTION:
If your system has a module containing a lithium battery, replace it only with the same or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
•Do not:
Throw or immerse into water
Heat to more than 100 degrees C (212 degrees F)
Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
CAUTION:
When laser products (such as CD-ROMs, DVD-ROM drives, fiber optic devices, or transmitters) are installed, note the following:
Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following:
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
ix
xx
xx
xx
xx
18 kg (37 lbs) 32 kg (70.5 lbs) 55 kg (121.2 lbs)
CAUTION:
Use safe practices when lifting.
CAUTION:
2
1
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted devices.
CAUTION:
Do not place any object weighing more then 82 kg (180lbs.) on top of rack-mounted devices.
x Intel Server Compute Blade SBX82 Installation and User’s Guide
xx
xx
CAUTION:
To avoid personal injury, before lifting the unit, remove all the blades to reduce the weight.
CAUTION:
Hazardous energy is present when the blade is connected to the power source. Always replace the blade cover before installing the blade.
Regulatory specifications and disclaimers
Safety compliance
USA: UL 60950 - 3rd Edition/CSA 22.2. No. 60950
Canada: cUL certified - 3rd Edition/CSA 22.2. No. 60950- for
Canada (product bears the single cUL mark for U.S. and Canada)
Europe: Low Voltage Directive, 73/23/EEC
TUV/CB to EN60950 3rd Edition TUC/CB - EMKO-TSE (74-SEC) 207/94
International: TUVCB to IEC 60950, 3rd Edition plus all
international deviations
Australia/New Zealand: CB Report to IEC 60950, 3rd Edition plus
Australia/New Zealand deviations
xi
Electromagnetic compatibility (ECM)
USA: FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada: IC ICES-003 Class A Limit
Europe: EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions EN55024 ITE Specific Immunity Standard EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge) EN61000-4-3 Radiated Immunity (Level 2) EN61000-4-4 Electrical Fast Transient (Level 2) EN61000-4-5 AC Surge EN61000-4-6 Conducted RF EN61000-4-8 Power Frequency Magnetic Fields EN61000-4-11 Voltage Dips and Interrupts EN6100-3-3 Voltage Flicker
Japan: VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 1000-3-2 Limit for Harmonic Current Emissions
Australia/New Zealand:
AS/NZS 3548, Class A Limit
Taiwan: BSMI Approval
Korea: RRL Approval
Russia: GOST Approval
Electromagnetic compatibility notices (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
NOTE
Class A device definition: If a Class A device is installed within the is system, then the system is to be considered a Class A system. In this configuration, operation of this equipment in a residential area is likely to cause harmful interference.
NOTE
This product is intended to be installed with CAT5 cable, or equivalent, to minimize electrical interference.
xii Intel Server Compute Blade SBX82 Installation and User’s Guide
Electromagnetic compatibility notices (International)
Europe (CE Declaration of Conformity): This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.
Japan EMC Compatibility:
English translation of the notice above: This is a Class A product based on the standard of the
Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
ICES-003 (Canada): Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques", NMB-003 édictée par le Ministre Canadian des Communications.
English translation of the notice above: This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of the Canadian Department of Communications.
BSMI (Taiwan): The BSMI Certification number and the following warning is located on the product safety label which is located visibly on the external chassis.
xiii
RRL Korea:
English translation of the notice above:
Device User’s Information
Class A device This device complies with RRL EMC and is operated
in a commercial environment so that distributors or users pay attention to this point.
If this product is sold or purchased improperly, please exchange this product to one that can be used at home.
Class B device This device complies with RRL EMC and is operated
in a residential area so that it can be used at all other location as well as residential area.
NOTE
Class A device: operated in a commercial area. Class B device: operated in a residential area.
xiv Intel Server Compute Blade SBX82 Installation and User’s Guide
1 Introducing the Intel® Server Compute Blade
SBX82 blade server
These high-performance blade servers are ideally suited for networking environments that require superior processor performance, efficient memory management, flexibility, and reliable data storage.
This Installation and User Guide provides information about:
Setting up the blade server
Starting and configuring the blade server
Installing hardware options
Installing the operating system
Performing basic troubleshooting of the blade server
Record information about your Intel Server Compute Blade SBX82 in the following table.
NOTE
The model number and serial number are on the ID label that is behind the control panel door on the front of the blade server, and on a label on the right side of the blade server that is visible when the blade server is not in the SBCE unit.
Product name Intel® Server Compute Blade SBX82
Product code
Model number _____________________________________________
Serial number _____________________________________________
Your Intel Server Compute Blade SBX82 will have one of the bezels shown in the following illustration.
NOTE
The illustrations in this document might differ slightly from your hardware.
1
Figure 1. Blade server release levers.
Release levers
Release button
A set of user labels comes with the Intel Server Compute Blade SBX82. When you install the blade server in the SBCE unit, write identifying information on a label and place the label on the SBX82 unit bezel.
Figure 2 shows the placement of the label, just below the blade server, on the SBCE unit.
2 Intel Server Compute Blade SBX82 Installation and User’s Guide
Figure 2. Label placement on the SBCE unit.
Important: Do not place the label on the blade server itself or in any way block the ventilation holes on the blade server.
3
Features and specifications
This section provides a summary of the features and specifications of your blade server. Use the Configuration/Setup Utility program to determine the specific type of processor that is in the blade server.
Reliability, availability, and serviceability features
Three of the most important features in server design are reliability, availability, and serviceability (RAS). These RAS features help to ensure the integrity of the data stored on the blade server; that the blade server is available when you want to use it; and that should a failure occur, you can easily diagnose and repair the failure with minimal inconvenience.
The blade server has the following RAS features:
Advanced Configuration and Power Interface (ACPI)
Automatic error retry or recovery
Automatic server restart
Built-in monitoring for temperature, voltage, hard disk drives, and flash drives
Chipkill* memory for DIMMs with a capacity of 512 MB or greater
Customer upgradeable basic input/output system (BIOS) code
Diagnostic support of Ethernet controllers
Error codes and messages
ECC protection on the L2 cache
ECC memory
Failover Ethernet support
Hot-swap drives on optional small computer system interface (SCSI) storage expansion unit
Light Path Diagnostics* feature
Power-on self-test (POST)
Predictive Failure Analysis* (PFA) alerts
Processor serial number access
Service processor that communicates with the management module to enable remote blade server management
SDRAM with serial presence detect (SPD) and vital product data (VPD)
System error logging
VPD (includes information stored in nonvolatile memory for easier remote viewing)
Wake on LAN* capability
4 Intel Server Compute Blade SBX82 Installation and User’s Guide
Intel Server Compute Blade SBX82 features
The design of your blade server takes advantage of advancements in memory management and data storage. Your blade server uses the following features and technologies:
Disk drive support The blade server supports up to two 2.5-inch SCSI disk drives.
Intel Architecture Intel architecture technology leverages proven innovative technologies to build powerful,
scalable, reliable Intel-processor-based servers. The technology includes features such as Light Path Diagnostics, Predictive Failure Analysis (PFA), and Advanced System Management.
Impressive performance using the latest processor technology
Your blade server supports up to two Intel least one processor installed; you can install an additional processor to further enhance performance and symmetric multiprocessing (SMP) capability.
Integrated network environment support The blade server comes with two integrated dual Gigabit Ethernet controllers. Each Ethernet controller has an interface for connecting to 10/100/1000-Mbps networks through an Ethernet-
compatible switch module on the SBCE unit. The blade server automatically selects between 10BASE-T and 100/1000BASE-TX environments. Each controller provides full-duplex (FDX) capability, which enables simultaneous transmission and reception of data on the Ethernet local area network (LAN). The controllers support Wake on LAN technology.
®
Xeon™ processors. The blade server comes with at
I/O expansion The blade server comes with two connectors on the system board for an optional expansion card, such as the Intel
®
Blade Server Fibre Channel Expansion Card or the Intel® Blade Server Ethernet Expansion Card, for adding more network communication capabilities to the blade server.
Large system memory
The memory bus in your blade server supports up to 8GB of system memory. The memory controller provides support for up to four industry-standard 1.8 V, 184-pin, double-data-rate (DDR2-400), PC3200, registered synchronous dynamic random-access memory (SDRAM) with error correcting code (ECC) DIMMs.
Light Path Diagnostics
The Light Path Diagnostics feature provides light-emitting diodes (LEDs) to assist in isolating problems with the blade server. An LED on the blade server control panel is lit if an unusual condition or a problem occurs. If this happens, you can look at the LEDs on the system board to locate the source of the problem.
PCI Express*
PCI Express* is a fully serial interface that can be used for universal connectivity for use as a chip-to-chip interconnect, I/O interconnect for adapter cards, and an I/O attachment point to Gigabit networking devices. PCI Express bridges a PCI Express bus to a PCI-X bus and converts the transactions on the PCI bus to transactions on the PCI-X bus. Using the expansion card connector you can add additional LAN interfaces. The expansion card connector supports PCI­X 133 and bridges PCI Express into PCI-X 133.
5
Power throttling
Each blade server is powered by two SBCE unit redundant 2000 W power supply modules. By enforcing a power policy known as oversubscription, the SBCE unit can load-share power between two power modules to ensure efficient power for each device in the SBCE unit. This policy is enforced when the initial power is applied to the SBCE unit or when a blade server is inserted into the SBCE unit.
The possible settings for this policy are: — Redundant without performance impact — Redundant with performance impact — Non-redundant You can configure and monitor the power environment using the management module. For more
information about configuring and using power throttling, refer to your management module manual.
Intel Server Compute Blade SBX82 specifications
The following table provides a summary of the features and specifications of the Intel Server Compute Blade SBX82.
NOTE
Power, cooling, removable-media drives, external ports, and advanced system management are provided by the SBCE unit.
NOTE
The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard, mouse, CD-ROM drive, and diskette drive. The SBCE unit uses USB for internal communications with these devices.
6 Intel Server Compute Blade SBX82 Installation and User’s Guide
Processor:
Supports up to two processors
®
Intel
Intel
Xeon™ processors with an 800 MHz FSB at speeds up to 3.6GHz
®
E7520 chipset
Memory:
Dual channel 400 MHz (DDR2) with four DIMM slots (8 GB maximum)
Type: 2-way interleaved, DDR2, PC3200, ECC SDRAM registered x4 (Chipkill*) DIMMs only
Supports 256 MB, 512 MB, 1 GB, and 2 GB DIMMs (four DIMM slots)
Service Processor:
Renassas 2166 supports:
RS-485 interface
Serial over LAN (SOL)
•IPMI
Drives:
Support for two internal small form-factor SCSI drives
Size:
Height: 24.5 cm (9.7 inches)
Depth: 44.6 cm (17.6 inches)
Width: 2.9 cm (1.14 inches)
Maximum weight: 5.4 kg (12 lb)
Integrated functions:
Dual Gigabit Ethernet controllers
Expansion card interface
BMC with IPMI firmware
ATI* 7000M video controller
LSI* 1020 SCSI controller
Light Path Diagnostics
Local service processor
RS-485 interface for communication with the management module
Four USB buses for communication with keyboard, mouse, diskette drive, and CD-ROM drive
Predictive Failure Analysis (PFA) alerts:
Processor
Memory
Electrical Input:
12 V dc
Environment:
Air temperature: — Blade server on: 10° to 35°
C (50° to 95° F). Altitude: 0 to 914 m (2998.69 ft)
— Blade server on: 10° to 32°
C (50° to 89.6° F). Altitude: 914 m to 2134 m (2998.69 ft to 7000 ft)
— Blade server off: -40° to
60° C (-40° to 140° F)
•Humidity: — Blade server on: 8% to
80%
— Blade server off: 5% to
80%
7
Major components of the blade server
You must remove the blade server from the SBCE unit and remove the cover to see the components.
NOTE
The illustrations in this document might differ slightly from your hardware.
Figure 3 shows the major components of the SBX82 unit.
Figure 3. SBX82 unit major components.
DIMM
Blade expansion unit connector
Heat sink
Processor
SCSI hard disk drives
Bezel
Processor heat sink filler
assembly
Related publications
In addition to this Installation and User’s Guide, the following documentation is provided in Portable Document Format (PDF) on the Intel Server Compute Blade SBX82 Resource CD that came with your blade server.
Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide
This document contains information to help you solve problems yourself. It also contains information for service technicians.
Intel Server Compute Blade SBX82 Installation and User’s Guide
This document contains instructions for setting up and configuring the SBX82 unit and basic instructions for installing some options. It also contains general information about the SBX82 unit.
8 Intel Server Compute Blade SBX82 Installation and User’s Guide
Notices and statements used in this document
The following notices and statements are used in the documentation:
Note: These notices provide important tips, guidance, or advice.
Important: These notices provide information or advice that might help you avoid inconvenient
or problem situations.
Attention: These notices indicate possible damage to programs, devices, or data. An attention
notice is placed just before the instruction or situation in which damage could occur.
Caution: These statements indicate situations that can be potentially hazardous to you. A
caution statement is placed just before the description of a potentially hazardous procedure step or situation.
Danger: These statements indicate situations that can be potentially lethal or extremely
hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.
9
10 Intel Server Compute Blade SBX82 Installation and User’s Guide 11
2 Using power, controls, jumpers, switches, and
indicators
This chapter describes the power features, how to turn on and turn off the blade server, what the controls and indicators mean, and where the system board jumpers and switches are located and how to use them.
Turning on the blade server
After you connect the blade server to power through the SBCE unit, the blade server can start in any of the following ways:
You can press the power-control button on the front of the blade server (behind the control panel door) to start the server.
NOTE
Wait until the power-on LED on the blade server flashes slowly before pressing the blade server power-control button. During this time, the service processor in the management module is initializing; therefore, the power-control button on the blade server does not respond.
NOTE
While the blade server is powering up, the power-on LED on the front of the server is lit. See “Understanding the control panel and LEDs” on page 13 for the power-on LED states.
If a power failure occurs, the SBCE unit and then the blade server can start automatically when power is restored if the blade server is configured through the management module to do so.
You can turn on the blade server remotely by means of the service processor in the management module.
If your operating system supports the Wake on LAN feature and the blade server power-on LED is flashing slowly, the Wake on LAN feature can turn on the blade server, if the Wake on LAN feature has not been disabled through the management-module Web interface.
Turning off the blade server
When you turn off the blade server, it is still connected to power through the SBCE unit. The blade server can respond to requests from the service processor, such as a remote request to turn on the blade server. To remove all power from the blade server, you must remove it from the SBCE unit.
Shut down your operating system before you turn off the blade server. See your operating-system documentation for information about shutting down the operating system.
The blade server can be turned off in any of the following ways:
You can press the power-control button on the blade server behind the control panel door. See “Understanding the control panel and LEDs” on page 13. This starts an orderly shutdown of the operating system, if this feature is supported by your operating system.
NOTE
After turning off the blade server, wait at least 5 seconds before you press the power­control button to turn on the blade server again.
If the operating system stops functioning, you can press and hold the power-control button for more than 4 seconds to turn off the blade server.
The management module can turn off the blade server.
NOTE
After turning off the blade server, wait at least 30 seconds for its hard disk drives or flash drives to stop before you remove the blade server from the SBCE unit.
12 Intel Server Compute Blade SBX82 Installation and User’s Guide
Understanding the control panel and LEDs
This section describes the controls and LEDs on your SBCE unit.
NOTE
The illustrations in this document might differ slightly from your hardware.
NOTE
The control panel door is shown in the closed (normal) position in the illustration. To access the power-control button, you must open the control panel door.
CD/diskette/USB select button
eyboard/mouse/video
elect button
Activity LED
Location LED
Information LED
Blade-error LED
NMI
Power-control button
Power-on LED
Keyboard/mouse/video (KVM) select button: Press this button to associate the keyboard port, mouse port, and video port with this blade server. The LED on this button flashes while the request is being processed, then is lit when the ownership of the keyboard, mouse, and video has been transferred to this blade server. It can take approximately 20 seconds to switch the keyboard, video, and mouse control to the blade server.
Although the keyboard that is attached to the SBCE unit is a PS/2*-style keyboard, communication with it is through the USB. The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard and mouse. The SBCE unit uses USB for internal communication with these devices. When you are running an operating system that does not have USB device drivers, such as in the following situations, the keyboard responds very slowly:
Running the blade server integrated diagnostics
Running a BIOS update diskette on a blade server
Updating the diagnostics on a blade server
Running the Broadcom firmware CD for a blade server
If there is no response when you press the keyboard/mouse/video select button, you can use the management-module Web interface to determine whether local control has been disabled on the blade server.
13