A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies & Products
Order Number C90879-001
12
1
Disclaimer
Information in this document is provided in connection with Intel. products. No license, express or
implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as
provided in Intel's Terms and Conditions of Sale for such products.
Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale
and/or use of Intel products including liability or warranties relating to fitness for a particular purpose,
merchantability, or infringement of any patent, copyright or other intellectual property right.
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation
where personal injury or death may occur. Intel may make changes to specifications and product
descriptions at any time, without notice.
Intel, Pentium, Itanium and Xeon are trademarks or registered trademarks of Intel Corporation or its
subsidiaries in the United States and other countries.
Getting help and information from the World Wide Web . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
ivIntel Server Compute Blade SBX82 Installation and User’s Guide
Safety and regulatory information
W
✏ NOTE
The service procedures are designed to help you isolate problems. They are written with the
assumption that you have model-specific training on all computers, or that you are familiar
with the computers, functions, terminology, and service information provided in this
manual.
Important Safety Instructions
Read all caution and s afety statements in t his document befo re perfo rming any of the
inst ruct io n s. S e e Intel Server Boards and Server Chass is Safety Infor m ation on the
Resource CD and/or at http:\\support.intel.com
ichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise
zu Intel-Serverp latinen und -Servergehäusen auf der Ressour cen-CD oder unter
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
doc ument avant de suivr e toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site
http:\\support.intel.com
.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de
reali zar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chas s is Safety Information en el CD Resource y/o en http:\\support.intel.com
.
上的I ntel Server Boards and Server
.
v
xx
General Safety
Follow these rules to ensure general safety:
•Observe good housekeeping in the area of the machines during and after maintenance.
•When lifting any heavy object:
1.Ensure you can stand safely without slipping.
2.Distribute the weight of the object equally between your feet.
3.Use a slow lifting force. Never move suddenly, or twist,when you attempt to lift.
4.Lift by standing or by pushing up with you leg muscles; this action removes the strain from the
muscles in your back. Do not attempt to lift any object that weighs more than 16 kg (35lb) or any
object that you think is too heavy for you.
•Do not perform any action that causes hazards to the customer, or makes the equipment unsafe.
•Before you start the machine, ensure that other service representatives and the customer’s
personnel are not in a hazardous position.
•Place removed covers and other parts in a safe place, away from all personnel, while you are
servicing the machine.
•Keep your tool case away from walk areas so that other people will not trip over it.
•Do not wear loose clothing that can be trapped in the moving parts of a machine. Ensure that
your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it.
•Insert the ends of your necktie or scarf inside clothing, or fasten it with a nonconductive clip,
approximately 8 centimeters (3 inches) from the end.
•Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing.
Remember: Metal objects are good electrical conductors.
•Wear safety glasses when you are: hammering, drilling soldering, cutting wire, attaching
springs, using solvents, or working in any other conditions that might be hazardous to your eyes.
•After service, reinstall all safety shields, guards, labels, and ground wires. Replace any safety
device that is worn or defective.
•Reinstall all covers correctly before returning the machine to the customer.
Electrical Safety
CAUTION:
Electrical current from power, telephone, and communication cables can be hazardous. To
avoid personal injury or equipment damage, disconnect the server system power cords,
telecommunication systems, networks, and modems before you open the server covers, unless
instructed otherwise in the installation and configuration procedures.
Important: Disconnect all power before performing a mechanical inspection.
Observe the following rules when working on electrical equipment.
•Use only approved tools and test equipment. Some hand tools have handles covered with a soft
material that does not protect you when working with live electrical currents.
•Many customers have rubber floor mats (near their equipment) that contain small conductive
fibers to decrease electrostatic discharges. Do not use this type of mat to protect yourself from
electrical shock.
viIntel Server Compute Blade SBX82 Installation and User’s Guide
•Find the emergency power-off (EPO) switch, disconnect switch, or electrical outlet in the room.
If an electrical accident occurs, you can quickly turn off the switch or unplug the power cord.
•Do not work alone under hazardous conditions, or near equipment that has hazardous voltages.
•Disconnect all power before:
— Performing a mechanical inspection
— Working near power supplies
— Removing or installing main units
•Before you start to work on the machine, unplug the power cord. If you cannot unplug it, ask the
customer to power-off the wall box (that supplies power to the machine) and to lock the wall box
in the off position.
•If you need to work on a machine that has exposed electrical circuits, observe the following
precautions:
— Ensure that another person, familiar with the power-off controls, is near you. Remember:
another person must be there to switch off the power, if necessary.
— Use only one hand when working with powered-on electrical equipment; keep the other
hand in your pocket or behind your back.
— Remember: There must be a complete circuit to cause electrical shock. By observing the
above rule, you may prevent a current from passing through your body.
•When using testers, set controls correctly and use the approved probe leads and accessories for
that tester.
•Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such
as metal floor strips and machine frames.
•Observe the special safety precautions when you work with very high voltages; these
instructions are in the safety sections of the maintenance information. Use extreme care when
measuring high voltages.
•Regularly inspect and maintain your electrical hand tools for safe operational condition.
•Do not use worn or broken tools and testers.
•Never assume that power has been disconnected from a circuit. First, check that it has been
powered-off.
•Always look carefully for possible hazards in your work area. Examples of these hazards are
moist floors, nongrounded power extension cables, power surges, and missing safety grounds.
•Do not touch live electrical circuits with the reflective surface of a plastic dental inspection
mirror. The surface is conductive; such touching can cause personal injury and machine damage.
•When the power is on and power supply units, blowers and fans are removed from their normal
operating position in a machine, do not attempt to service the units. This practice ensures correct
grounding of the units.
•If an electrical accident occurs, use caution:
— Switch power off
— Send another person to get help/medical aid
Any computer part containing transistors or integrated circuits (IC) should be considered sensitive to
electrostatic discharge (ESD). ESD damage can occur when there is a difference in charge between
objects. Protect against ESD damage by equalizing the charge so that the server, the part, the work
mat, and the person handling the part are all at the same charge.
✏ NOTE
Use product-specific ESD procedures when they exceed the requirements noted here.
Make sure that the ESD-protective devices you use have been certified (ISO 9000) as fully effective.
When handling ESD-sensitive parts:
•Keep the parts in protective packages until they are inserted into the product.
•Avoid contact with other people.
•Wear a grounded wrist strap against your skin to eliminate static on your body.
•Prevent the part from touching your clothing. Most clothing is insulative and retains a charge
even when you are wearing a wrist strap.
•Use the black side of a grounded work mat to provide a static-free work surface. The mat is
especially useful when handling ESD-sensitive devices.
•Select a grounding system, such as those in the following list, to provide protection that meets
the specific service requirement.
— Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground.
— Use an ESD common ground or reference point when working on a double-insulated or
battery-operated system. You can use coax or connector-outside shells on these systems.
— Use the round ground-prong of the AC plug on AC-operated computers.
✏ NOTE
The use of a grounding system is desirable but not required to protect against ESD
damage.
DANGER
Electrical current from power, telephone and communication cables is hazardous.
To avoid a shock hazard:
•Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this
product during an electrical storm.
•Connect all power cords to a properly wired and grounded electrical outlet.
•Connect to properly wired outlets any equipment that will be attached to this product.
•When possible, use one hand only to connect or disconnect signal cables.
•Never turn on any equipment when there is evidence of fire, water, or structural damage.
•Disconnect the attached power cords, telecommunications systems, networks, and modems before you
open the device covers, unless instructed otherwise in the installation and configuration procedures.
•Connect and disconnect cables as described in the following table when installing, moving, or opening
covers on this product or attached devices.
viiiIntel Server Compute Blade SBX82 Installation and User’s Guide
xx
xx
To ConnectTo Disconnect
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
5. Turn device ON.
CAUTION:
If your system has a module containing a lithium battery, replace it only with the same or an
equivalent type battery recommended by the manufacturer. If your system has a module
containing a lithium battery, replace it only with the same module type made by the same
manufacturer. The battery contains lithium and can explode if not properly used, handled, or
disposed of.
•Do not:
•Throw or immerse into water
•Heat to more than 100 degrees C (212 degrees F)
•Repair or disassemble
•Dispose of the battery as required by local ordinances or regulations.
CAUTION:
When laser products (such as CD-ROMs, DVD-ROM drives, fiber optic devices, or
transmitters) are installed, note the following:
•Do not remove the covers. Removing the covers of the laser product could result in exposure
to hazardous laser radiation. There are no serviceable parts inside the device.
•Use of controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the
following:
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments,
and avoid direct exposure to the beam.
ix
xx
xx
xx
xx
≥18 kg (37 lbs)≥32 kg (70.5 lbs)≥55 kg (121.2 lbs)
CAUTION:
Use safe practices when lifting.
CAUTION:
2
1
CAUTION:
The power control button on the device and the power switch on the power supply do not
turn off the electrical current supplied to the device. The device also might have more than
one power cord. To remove all electrical current from the device, ensure that all power cords
are disconnected from the power source.
Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted devices.
CAUTION:
Do not place any object weighing more then 82 kg (180lbs.) on top of rack-mounted devices.
xIntel Server Compute Blade SBX82 Installation and User’s Guide
xx
xx
CAUTION:
To avoid personal injury, before lifting the unit, remove all the blades to reduce the weight.
CAUTION:
Hazardous energy is present when the blade is connected to the power source. Always
replace the blade cover before installing the blade.
Regulatory specifications and disclaimers
Safety compliance
USA:UL 60950 - 3rd Edition/CSA 22.2. No. 60950
Canada:cUL certified - 3rd Edition/CSA 22.2. No. 60950- for
Canada (product bears the single cUL mark for U.S.
and Canada)
Europe:Low Voltage Directive, 73/23/EEC
TUV/CB to EN60950 3rd Edition
TUC/CB - EMKO-TSE (74-SEC) 207/94
International:TUVCB to IEC 60950, 3rd Edition plus all
international deviations
Australia/New Zealand:CB Report to IEC 60950, 3rd Edition plus
Australia/New Zealand deviations
xi
Electromagnetic compatibility (ECM)
USA:FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada:IC ICES-003 Class A Limit
Europe:EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions
EN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
EN6100-3-3 Voltage Flicker
Japan:VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 1000-3-2 Limit for Harmonic Current Emissions
Australia/New
Zealand:
AS/NZS 3548, Class A Limit
Taiwan:BSMI Approval
Korea:RRL Approval
Russia:GOST Approval
Electromagnetic compatibility notices (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his/her own expense.
✏ NOTE
Class A device definition: If a Class A device is installed within the is system, then the
system is to be considered a Class A system. In this configuration, operation of this
equipment in a residential area is likely to cause harmful interference.
✏ NOTE
This product is intended to be installed with CAT5 cable, or equivalent, to minimize
electrical interference.
xiiIntel Server Compute Blade SBX82 Installation and User’s Guide
Europe (CE Declaration of Conformity): This product has been tested in accordance too, and
complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The
product has been marked with the CE Mark to illustrate its compliance.
Japan EMC Compatibility:
English translation of the notice above: This is a Class A product based on the standard of the
Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this
equipment is used in a domestic environment, radio disturbance may arise. When such trouble
occurs, the user may be required to take corrective actions.
ICES-003 (Canada): Cet appareil numérique respecte les limites bruits radioélectriques
applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur:
"Appareils Numériques", NMB-003 édictée par le Ministre Canadian des Communications.
English translation of the notice above: This digital apparatus does not exceed the Class A limits
for radio noise emissions from digital apparatus set out in the interference-causing equipment
standard entitled "Digital Apparatus," ICES-003 of the Canadian Department of Communications.
BSMI (Taiwan): The BSMI Certification number and the following warning is located on the
product safety label which is located visibly on the external chassis.
xiii
RRL Korea:
English translation of the notice above:
DeviceUser’s Information
Class A deviceThis device complies with RRL EMC and is operated
in a commercial environment so that distributors or
users pay attention to this point.
If this product is sold or purchased improperly, please
exchange this product to one that can be used at
home.
Class B deviceThis device complies with RRL EMC and is operated
in a residential area so that it can be used at all other
location as well as residential area.
✏ NOTE
Class A device: operated in a commercial area. Class B device: operated in a
residential area.
xivIntel Server Compute Blade SBX82 Installation and User’s Guide
1 Introducing the Intel® Server Compute Blade
SBX82 blade server
These high-performance blade servers are ideally suited for networking environments that require
superior processor performance, efficient memory management, flexibility, and reliable data storage.
This Installation and User Guide provides information about:
•Setting up the blade server
•Starting and configuring the blade server
•Installing hardware options
•Installing the operating system
•Performing basic troubleshooting of the blade server
Record information about your Intel Server Compute Blade SBX82 in the following table.
✏ NOTE
The model number and serial number are on the ID label that is behind the control panel
door on the front of the blade server, and on a label on the right side of the blade server that
is visible when the blade server is not in the SBCE unit.
Product nameIntel® Server Compute Blade SBX82
Product code
Model number_____________________________________________
Serial number_____________________________________________
Your Intel Server Compute Blade SBX82 will have one of the bezels shown in the following
illustration.
✏ NOTE
The illustrations in this document might differ slightly from your hardware.
1
Figure 1. Blade server release levers.
Release
levers
Release
button
A set of user labels comes with the Intel Server Compute Blade SBX82. When you install the blade
server in the SBCE unit, write identifying information on a label and place the label on the SBX82
unit bezel.
Figure 2 shows the placement of the label, just below the blade server, on the SBCE unit.
2Intel Server Compute Blade SBX82 Installation and User’s Guide
Figure 2. Label placement on the SBCE unit.
Important: Do not place the label on the blade server itself or in any way block the ventilation holes
on the blade server.
3
Features and specifications
This section provides a summary of the features and specifications of your blade server. Use the
Configuration/Setup Utility program to determine the specific type of processor that is in the blade
server.
Reliability, availability, and serviceability features
Three of the most important features in server design are reliability, availability, and serviceability
(RAS). These RAS features help to ensure the integrity of the data stored on the blade server; that
the blade server is available when you want to use it; and that should a failure occur, you can easily
diagnose and repair the failure with minimal inconvenience.
The blade server has the following RAS features:
•Advanced Configuration and Power Interface (ACPI)
•Automatic error retry or recovery
•Automatic server restart
•Built-in monitoring for temperature, voltage, hard disk drives, and flash drives
•Chipkill* memory for DIMMs with a capacity of 512 MB or greater
•Customer upgradeable basic input/output system (BIOS) code
•Diagnostic support of Ethernet controllers
•Error codes and messages
•ECC protection on the L2 cache
•ECC memory
•Failover Ethernet support
•Hot-swap drives on optional small computer system interface (SCSI) storage expansion unit
•Light Path Diagnostics* feature
•Power-on self-test (POST)
•Predictive Failure Analysis* (PFA) alerts
•Processor serial number access
•Service processor that communicates with the management module to enable remote blade
server management
•SDRAM with serial presence detect (SPD) and vital product data (VPD)
•System error logging
•VPD (includes information stored in nonvolatile memory for easier remote viewing)
•Wake on LAN* capability
4Intel Server Compute Blade SBX82 Installation and User’s Guide
Intel Server Compute Blade SBX82 features
The design of your blade server takes advantage of advancements in memory management and data
storage. Your blade server uses the following features and technologies:
•Disk drive support
The blade server supports up to two 2.5-inch SCSI disk drives.
scalable, reliable Intel-processor-based servers. The technology includes features such as Light
Path Diagnostics, Predictive Failure Analysis (PFA), and Advanced System Management.
•Impressive performance using the latest processor technology
Your blade server supports up to two Intel
least one processor installed; you can install an additional processor to further enhance
performance and symmetric multiprocessing (SMP) capability.
•Integrated network environment support
The blade server comes with two integrated dual Gigabit Ethernet controllers. Each Ethernet
controller has an interface for connecting to 10/100/1000-Mbps networks through an Ethernet-
compatible switch module on the SBCE unit. The blade server automatically selects between
10BASE-T and 100/1000BASE-TX environments. Each controller provides full-duplex (FDX)
capability, which enables simultaneous transmission and reception of data on the Ethernet local
area network (LAN). The controllers support Wake on LAN technology.
®
Xeon™ processors. The blade server comes with at
•I/O expansion
The blade server comes with two connectors on the system board for an optional expansion card,
such as the Intel
®
Blade Server Fibre Channel Expansion Card or the Intel® Blade Server
Ethernet Expansion Card, for adding more network communication capabilities to the blade
server.
•Large system memory
The memory bus in your blade server supports up to 8GB of system memory. The memory
controller provides support for up to four industry-standard 1.8 V, 184-pin, double-data-rate
(DDR2-400), PC3200, registered synchronous dynamic random-access memory (SDRAM) with
error correcting code (ECC) DIMMs.
•Light Path Diagnostics
The Light Path Diagnostics feature provides light-emitting diodes (LEDs) to assist in isolating
problems with the blade server. An LED on the blade server control panel is lit if an unusual
condition or a problem occurs. If this happens, you can look at the LEDs on the system board to
locate the source of the problem.
•PCI Express*
PCI Express* is a fully serial interface that can be used for universal connectivity for use as a
chip-to-chip interconnect, I/O interconnect for adapter cards, and an I/O attachment point to
Gigabit networking devices. PCI Express bridges a PCI Express bus to a PCI-X bus and converts
the transactions on the PCI bus to transactions on the PCI-X bus. Using the expansion card
connector you can add additional LAN interfaces. The expansion card connector supports PCIX 133 and bridges PCI Express into PCI-X 133.
5
•Power throttling
Each blade server is powered by two SBCE unit redundant 2000 W power supply modules. By
enforcing a power policy known as oversubscription, the SBCE unit can load-share power
between two power modules to ensure efficient power for each device in the SBCE unit. This
policy is enforced when the initial power is applied to the SBCE unit or when a blade server is
inserted into the SBCE unit.
The possible settings for this policy are:
— Redundant without performance impact
— Redundant with performance impact
— Non-redundant
You can configure and monitor the power environment using the management module. For more
information about configuring and using power throttling, refer to your management module
manual.
Intel Server Compute Blade SBX82 specifications
The following table provides a summary of the features and specifications of the Intel Server
Compute Blade SBX82.
✏ NOTE
Power, cooling, removable-media drives, external ports, and advanced system management
are provided by the SBCE unit.
✏ NOTE
The operating system in the blade server must provide USB support for the blade server to
recognize and use the keyboard, mouse, CD-ROM drive, and diskette drive. The SBCE unit
uses USB for internal communications with these devices.
6Intel Server Compute Blade SBX82 Installation and User’s Guide
Processor:
Supports up to two processors
®
•Intel
•Intel
Xeon™ processors with
an 800 MHz FSB at speeds
up to 3.6GHz
®
E7520 chipset
Memory:
•Dual channel 400 MHz
(DDR2) with four DIMM slots
(8 GB maximum)
Support for two internal small
form-factor SCSI drives
Size:
•Height: 24.5 cm (9.7 inches)
•Depth: 44.6 cm (17.6 inches)
•Width: 2.9 cm (1.14 inches)
•Maximum weight: 5.4 kg
(12 lb)
Integrated functions:
•Dual Gigabit Ethernet
controllers
•Expansion card interface
•BMC with IPMI firmware
•ATI* 7000M video controller
•LSI* 1020 SCSI controller
•Light Path Diagnostics
•Local service processor
•RS-485 interface for
communication with the
management module
•Four USB buses for
communication with
keyboard, mouse, diskette
drive, and CD-ROM drive
Predictive Failure Analysis
(PFA) alerts:
•Processor
•Memory
Electrical Input:
12 V dc
Environment:
•Air temperature:
— Blade server on: 10° to 35°
C (50° to 95° F). Altitude: 0
to 914 m (2998.69 ft)
— Blade server on: 10° to 32°
C (50° to 89.6° F). Altitude:
914 m to 2134 m (2998.69
ft to 7000 ft)
— Blade server off: -40° to
60° C (-40° to 140° F)
•Humidity:
— Blade server on: 8% to
80%
— Blade server off: 5% to
80%
7
Major components of the blade server
You must remove the blade server from the SBCE unit and remove the cover to see the components.
✏ NOTE
The illustrations in this document might differ slightly from your hardware.
Figure 3 shows the major components of the SBX82 unit.
Figure 3. SBX82 unit major components.
DIMM
Blade expansion
unit connector
Heat sink
Processor
SCSI hard
disk drives
Bezel
Processor
heat sink filler
assembly
Related publications
In addition to this Installation and User’s Guide, the following documentation is provided in
Portable Document Format (PDF) on the Intel Server Compute Blade SBX82 Resource CD that came
with your blade server.
•Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide
This document contains information to help you solve problems yourself. It also contains
information for service technicians.
•Intel Server Compute Blade SBX82 Installation and User’s Guide
This document contains instructions for setting up and configuring the SBX82 unit and basic
instructions for installing some options. It also contains general information about the SBX82
unit.
8Intel Server Compute Blade SBX82 Installation and User’s Guide
Notices and statements used in this document
The following notices and statements are used in the documentation:
•Note: These notices provide important tips, guidance, or advice.
•Important: These notices provide information or advice that might help you avoid inconvenient
or problem situations.
•Attention: These notices indicate possible damage to programs, devices, or data. An attention
notice is placed just before the instruction or situation in which damage could occur.
•Caution: These statements indicate situations that can be potentially hazardous to you. A
caution statement is placed just before the description of a potentially hazardous procedure step
or situation.
•Danger: These statements indicate situations that can be potentially lethal or extremely
hazardous to you. A danger statement is placed just before the description of a potentially lethal
or extremely hazardous procedure step or situation.
9
10Intel Server Compute Blade SBX82 Installation and User’s Guide 11
2 Using power, controls, jumpers, switches, and
indicators
This chapter describes the power features, how to turn on and turn off the blade server, what the
controls and indicators mean, and where the system board jumpers and switches are located and how
to use them.
Turning on the blade server
After you connect the blade server to power through the SBCE unit, the blade server can start in any
of the following ways:
•You can press the power-control button on the front of the blade server (behind the control panel
door) to start the server.
✏ NOTE
Wait until the power-on LED on the blade server flashes slowly before pressing the blade
server power-control button. During this time, the service processor in the management
module is initializing; therefore, the power-control button on the blade server does not
respond.
✏ NOTE
While the blade server is powering up, the power-on LED on the front of the server is lit.
See “Understanding the control panel and LEDs” on page 13 for the power-on LED states.
•If a power failure occurs, the SBCE unit and then the blade server can start automatically when
power is restored if the blade server is configured through the management module to do so.
•You can turn on the blade server remotely by means of the service processor in the management
module.
•If your operating system supports the Wake on LAN feature and the blade server power-on LED
is flashing slowly, the Wake on LAN feature can turn on the blade server, if the Wake on LAN
feature has not been disabled through the management-module Web interface.
Turning off the blade server
When you turn off the blade server, it is still connected to power through the SBCE unit. The blade
server can respond to requests from the service processor, such as a remote request to turn on the
blade server. To remove all power from the blade server, you must remove it from the SBCE unit.
Shut down your operating system before you turn off the blade server. See your operating-system
documentation for information about shutting down the operating system.
The blade server can be turned off in any of the following ways:
•You can press the power-control button on the blade server behind the control panel door. See
“Understanding the control panel and LEDs” on page 13. This starts an orderly shutdown of the
operating system, if this feature is supported by your operating system.
✏ NOTE
After turning off the blade server, wait at least 5 seconds before you press the powercontrol button to turn on the blade server again.
•If the operating system stops functioning, you can press and hold the power-control button for
more than 4 seconds to turn off the blade server.
•The management module can turn off the blade server.
✏ NOTE
After turning off the blade server, wait at least 30 seconds for its hard disk drives or flash
drives to stop before you remove the blade server from the SBCE unit.
12Intel Server Compute Blade SBX82 Installation and User’s Guide
Understanding the control panel and LEDs
This section describes the controls and LEDs on your SBCE unit.
✏ NOTE
The illustrations in this document might differ slightly from your hardware.
✏ NOTE
The control panel door is shown in the closed (normal) position in the illustration. To access
the power-control button, you must open the control panel door.
CD/diskette/USB
select button
eyboard/mouse/video
elect button
Activity LED
Location LED
Information LED
Blade-error LED
NMI
Power-control button
Power-on LED
Keyboard/mouse/video (KVM) select button: Press this button to associate the keyboard port,
mouse port, and video port with this blade server. The LED on this button flashes while the request
is being processed, then is lit when the ownership of the keyboard, mouse, and video has been
transferred to this blade server. It can take approximately 20 seconds to switch the keyboard, video,
and mouse control to the blade server.
Although the keyboard that is attached to the SBCE unit is a PS/2*-style keyboard, communication
with it is through the USB. The operating system in the blade server must provide USB support for
the blade server to recognize and use the keyboard and mouse. The SBCE unit uses USB for internal
communication with these devices. When you are running an operating system that does not have
USB device drivers, such as in the following situations, the keyboard responds very slowly:
•Running the blade server integrated diagnostics
•Running a BIOS update diskette on a blade server
•Updating the diagnostics on a blade server
•Running the Broadcom firmware CD for a blade server
If there is no response when you press the keyboard/mouse/video select button, you can use the
management-module Web interface to determine whether local control has been disabled on the
blade server.