A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products
Order Number: A28554-001
Page 2
Disclaimer
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility
for any errors that may appear in this document. Intel makes no commitment to update nor to keep current the
information contained in this document. No part of this document may be copied or reproduced in any form or
by any means without prior written consent of Intel.
An Intel® product, when used in accordance with its associated documentation, is "Year 2000 Capable" when,
upon installation, it accurately stores, displays, processes, provides, and/or receives date data from, into, and
between the twentieth and twenty-first centuries, including leap year calculations, provided that all other
technology used in combination with said product properly exchanges date data with it.
†
Third party brands and trademarks are the property of their respective owners.
Copyright 2000 Intel Corporation.
Page 3
Contents
1Description
Server Board Features......................................................................................................... 7
Back Panel Connectors............................................................................................... 8
Server Board Connector and Component Locations.................................................... 9
Two PCI-66 MHz/64 bit expansion slots.
One PCI-33 MHz/64 bit expansion slots
SCSI interfaces.
100 Mbps TX Fast Ethernet networks. RJ-45 Ethernet connector at I/O back
panel.
Advanced parallel port, supporting Enhanced Parallel Port (EPP) level 1.7
and 1.9, ECP, compatible 25 pin.
VGA video port, 15 pin.
Two serial ports, 9 pin.
RJ-45 Ethernet port.
Two USB ports.
7
Page 8
Back Panel Connectors
A
C
BD
A. USB connectors
B. Serial port 2 connector
C. Serial port 1 connector
D. NMI switch
E. Keyboard connector
F. Mouse connector
G. Parallel port connector
H. Video connector
I. Network connector
E
F
G
I
H
Figure 1. Back Panel Connectors
OM10424
8Description
Page 9
Server Board Conne ctor and Component Locations
FF
EE
DD
CC
BB
AA
DA BCEK
F H
J
GI
L
M
N
O
P
Q
R
S
T
Z
Y
VW
A. Fan connector
B. Fan connector
C. CPU speed jumper block
D. Primary processor
E. Secondary processor
F. DIMM slot 4
G. DIMM slot 3
H. DIMM slot 2
I. DIMM slot 1
J. Power supply signal connector
K. Auxiliary power connector
L. Front panel connector P27
M. Power connector
N. Front panel connector P26
O. IDE connector
P. Speaker connector
Q. Floppy drive connector
R. Fan connector
S. Fan connector
T. Configuration jumper block
U. Reset switch connector
V. SE SCSI connector
W. LVD SCSI connector
X. Battery
Y. 33 MHz/32-bit PCI connector
Z. 33 MHz/32-bit PCI connector
AA. 33 MHz/32-bit PCI connector
BB. 33 MHz/64-bit PCI connector
CC. 66 MHz/64-bit PCI connector
DD. 66 MHz/64-bit PCI connector
EE. 33 MHz/32-bit PCI connector
FF. I/O ports
Figure 2. Server Board Connector and Component Locations
UX
OM10423
SBT2 Server Board Product Guide 9
Page 10
Processor
NOTE
✏
The SBT2 server board only supports processors with the following product
codes: BX80526KB866256, BX80526KB1000256, BX80526KB8001M.
Future processors may be supported. See the SBT2 support website for more
information.
Each Pentium III Xeon processor is packaged in a cartridge containing the processor core with an
integrated 16 KB primary (L1) cache, a secondary (L2) cache, and a cover. A passive heat sink is
attached to the back cover of the cartridge. The cartridge is secured to the system board by a
retention module and electrically connected to the board through a Slot 2 connector.
The processor external interface operates at a maximum of 133 MHz. The second-level cache is on
the substrate of the processor cartridge.
Memory
The system board contains four 168-pin DIMM sockets. Memory is partitioned as four banks of
registered SDRAM DIMMs (PC133 compatible), each providing 72 bits of noninterleaved memory
(64-bit main memory plus ECC).
Memory should be added in order from slot 1 to slot 4.
The controller automatically detects, sizes, and initializes the memory array, depending on the type,
size, and speed of the installed DIMMs, and reports memory size and allocation to the server via
configuration registers.
NOTE
✏
Use DIMMs that have been tested for compatibility with the server board.
Contact your sales representative or dealer for a current list of approved
memory modules. Check the Intel Customer Support website for the latest
tested memory list:
• Analog VGA monitors (single and multiple frequency, interlaced and noninterlaced) with a
maximum vertical retrace noninterlaced frequency of 100 Hz.
SCSI Controller
The embedded Adaptec AIC-7899 dual function SCSI controller provides both Ultra2 (LVDS)
wide and Ultra wide (SE) SCSI interfaces as two independent PCI functions.
The SCSI bus is terminated on the server board with active terminators that cannot be disabled.
The onboard device must always be at one end of the bus. The device at the end of the cable must
be terminated. LVDS devices generally do not have termination capabilities. Non-LVDS devices
generally are terminated through a jumpe r or resis tor pack.
IDE Controller
The system includes a single channel enhanced IDE 32 bit interface controller for intelligent disk
drives with disk controller electronics onboard. The controller has a connector located on the
system board that supports a master and a slave device.
The device controls:
• PIO and DMA transfer modes
• DMA-33 capable
• Mode 4 timings
• Transfer rates up to 33 MB/s
• Buffering for PCI/IDE burst transfers
• Master/slave IDE mode
• Up to two devices.
12Description
Page 13
Network Controller
NOTE
✏
To ensure EMC product regulation compliance, the end system must be used
with a shielded LAN cable.
The server board includes a 10BASE-T/100BASE-TX network solution based on the Intel 82559
single chip Fast Ethernet PCI Bus Controller. As a PCI bus master, the controller can burst data at
up to 132 MB/s. The controller contains two receive and transmit FIFO buffers that prevent data
overruns or underruns while waiting for access to the PCI bus. The controller has the following:
• 32 bit PCI bus master interface (direct drive of bus), compatible with PCI Bus Specification,
Revision 2.1
• Chained memory structure with improved dynamic transmit chaining for enhanced
performance
• Programmable transmit threshold for improved bus utilization
• Early receive interrupt for concurrent processing of receive data
• Onchip counters for network management
• Autodetect and autoswitching for 10 or 100 Mbps network speeds
• Support for both 10 Mbps and 100 Mbps networks, capable of full or half duplex, with back-to-
back transmit at 100 Mbps
Network Teaming Features
The network controller provides several options for increasing throughput and fault tolerance when
†
running Windows NT
• Adapter Fault Tolerance (AFT) - provides automatic redundancy for your adapter. If the
primary adapter fails, the secondary takes over. AFT works with any hub or switch.
• Adaptive Load Balancing (ALB) - creates a team of 2 - 4 adapters to increase transmission
throughput. Also includes AFT. Works with any 10Base-TX or 100Base-TX switch.
• Fast EtherChannel
reception throughput. Also includes AFT. Requires an FEC-enabled switch.
To set up an option, read the instructions in the Windows NT 4.0 or NetWare 4.1x readme files.
4.0, Windows† 2000 or NetWare† 4.1x or newer:
†
(FEC) - creates a team of 2, 3 or 4 adapters to increase transmission and
SBT2 Server Board Product Guide 13
Page 14
General Configuration Notes
1. Windows NT versions prior to 4.0 don’t support Adapter Teaming options.
2. Adapter Teaming options require NT 4.0 with Service Pack 4.0 or Service Pack 3.0 and Hotfix.
3. In Windows NT, teaming options cannot be implemented on adapters that have been
configured for VLANs. NetWare can support teaming options and VLANs on the same
adapters.
Adapter Fault Tolerance
Adapter Fault Tolerance (AFT) is a simple, effective, and fail-safe approach to increase the
reliability of server connections. AFT gives you the ability to set up link recovery to the server
adapter in case of a cable, port, or network interface card failure. By assigning two PRO/100
Intelligent Server adapters as a team, AFT enables you to maintain uninterrupted network
performance.
AFT is implemented with two PRO/100 Intelligent Server adapters: a primary adapter and a
backup, or secondary, adapter. During normal operation, the backup will have transmit disabled. If
the link to the primary adapter fails, the link to the backup adapte r auto mat ica lly takes ove r.
Preferred Primary Adapter
With multiple adapters installed, you can specify one as the Preferred Primary adapter. For
example if you have a server with a PRO/100 Intelligent Server adapter as the primary adapter and
a PRO/100+ adapter as the secondary, you would want the PRO/100 Intelligent Server adapter to be
the preferred primary. In this scenario, if the PRO/100 Intelligent Server adapter fails, the
PRO/100+ will take over. Then when the PRO/100 Intelligent Server adapter is replaced, it will
automatically revert to being the primary adapter in the team.
If a Preferred Primary is not selected, PROSet will attempt to select the best adapter, based on
adapter model and speed.
Mixed Adapter Teaming
AFT supports up to four PRO/1000 or PRO/100 adapters per team, in any mix.
Adaptive Load Balancing
Adaptive Load Balancing (ALB) is a simple and efficient way to increase your server’s transmit
throughput. With ALB you group PRO/100 Intelligent Server adapters in teams to provide an
increased transmit rate (up to 400 Mbps) using a maximum of four adapters. The ALB software
continuously analyzes transmit loading on each adapter and balances the rate across the adapters as
needed. Adapter teams configured for ALB also provide the benefits of AFT. Receive rates remain
at 100 Mbps.
To use ALB, you must have two, three, or four PRO/100 Intelligent Server adapters installed in
your server or workstation and linked to the same network switch.
14Description
Page 15
Cisco Fast EtherChannel
Fast EtherChannel (FEC) is a performance technology developed by Cisco to increase your server’s
throughput. Unlike ALB, FEC can be configured to increase both transmission and reception
channels between your server and switch. FEC works only with FEC-enabled switches, such as the
Catalyst 5000 series. With FEC, as you add adapters to your server, you can group them in teams
to provide up to 800 Mpbs at full duplex, with a maximum of four PRO/100 Intelligent Server
adapters. The FEC software continuously analyzes loading on each adapter and balances network
traffic across the adapters as needed. Adapter teams configured for FEC also provide the benefits
of AFT.
To use FEC, you must have two or four PRO/100 Intelligent Server adapters installed in your
server and linked to the same FEC-enabled Cisco switch.
Keyboard and Mouse
The keyboard/mouse controller is PS/2-compatible. The server may be locked automatically if
there is no keyboard or mouse activity for a predefined length of time, if specified through the
System Setup Utility (SSU). Once the inactivity (lockout) timer has expired, the keyboard and
mouse do not respond until the previously stored password is entered.
ACPI
The SBT2 supports the Advanced Configuration and Power Interface (ACPI) as defined by the
ACPI 1.0 and PC97 specifications. An ACPI aware operating system can put the system into a
state where the hard drives spin down, the system fans stop, and all processing is halted. However,
the power supply will still be on and the processors will still be dissipating some power, so the
power supply fan and processor fans will still run.
The SBT2 supports sleep states s0, s1, s4, and s5. With future versions of Microsoft Windows 9X
that support ACPI, the BIOS will only support sleep states s0, s1, and s5. With future versions of
Microsoft Windows NTx that support ACPI, the BIOS will support sleep states s0, s1, s4, and s5.
• s0: Normal running state.
• s1: Processor sleep state. No context will be lost in this state and the processor caches will
maintain coherency.
• s4: Hibernate or Save to Disk: The memory and machine state are saved to disk. Pressing the
power button or other wakeup event will restore the system state from the disk and resume
normal operation. This assumes that no hardware changes have been made to the system while
it was off.
• s5: Soft off: Only the RTC section of the PIIX4 and the BMC are running in this state.
CAUTION
The system is off only when the AC power is disconnected.
SBT2 Server Board Product Guide 15
Page 16
Security
To help prevent unauthorized entry or use of the server, Intel® Server Control server management
software monitors the system intrusion switch.
Security with Mechanical Locks and Monitoring
If installed, you can activate the chassis intrusion alarm switch. When the side door is opened, the
switch transmits an alarm signal to the server board, where BMC firmware and server management
software process the signal. The system can be programmed to respond to an intrusion by
powering down or by locking the keyboard, for example.
Software Locks
The BIOS Setup and the System Setup Utility (SSU) provide a number of security features to
prevent unauthorized or accidental access to the system. Once the security measures are enabled,
you can access the system only after you enter the correct password(s). For example:
• Enable the keyboard lockout timer so that the server requires a password to reactivate the
keyboard and mouse after a specified time out period1 to 120 minutes.
• Set and enable an supervisor password.
• Set and enable a user password.
• Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset
and power switches.
• Activate a hot key combination to enter secure mode quickly.
• Disable writing to the diskette drive when secure mode is set.
• Disable access to the boot sector of the operating system hard disk drive.
Using Passwords
You can set either the user password, the supervisor password, or both passwords. If only the user
password is set, you:
• Must enter the user password to enter BIOS Setup or the SSU.
• Must enter the user password to boot the server if Password on Boot is enabled in either the
BIOS Setup or SSU.
• Must enter the user password to exit secure mode.
If only the supervisor password is set, you:
• Must enter the supervisor password to enter BIOS Setup or the SSU.
• Must enter the supervisor password to boot the server if Password on Boot is enabled in either
the BIOS Setup or SSU.
• Must enter the supervisor password to exit secure mode.
If both passwords are set, you:
• May enter the user password to enter BIOS Setup or the SSU. However, you will not be able to
change many of the options.
• Must enter the supervisor password if you want to enter BIOS Setup or the SSU and have
access to all of the options.
16Description
Page 17
• May enter either password to boot the server if Password on Boot is enabled in either the BIOS
Setup or SSU.
• May enter either password to exit secure mode.
Secure Mode
Configure and enable the secure boot mode by using the SSU. When secure mode is in effect:
• You can boot the server and the operating system will run, but you must enter the user
password to use the keyboard or mouse.
• You cannot turn off system power or reset the server from the front panel switches.
Secure mode has no effect on functions enabled via the Server Manager Module or power control
via the real time clock.
Taking the server out of secure mode does not change the state of system power. That is, if you
press and release the power switch while secure mode is in effect, the system will not be powered
off when secure mode is later removed. However, if the front panel power switch remains
depressed when secure mode is removed, the server will be powered off.
Summary of Software Security Features
The table below lists the software security features and describes what protection each offers. In
general, to enable or set the features listed here, you must run the SSU and go to the Security
Subsystem Group, menu. The table also refers to other SSU menus and to the Setup utility.
Table 2.Software Security Features
FeatureDescription
Secure modeHow to enter secure mode:
• Setting and enabling passwords automatically places the system in secure
mode.
• If you set a hot-key combination (through Setup), you can secure the
system simply by pressing the key combination. This means you do not
have to wait for the inactivity time-out period.
When the system is in secure mode:
The server can boot and run the opera ting system, but mouse and keyboard
input is not accepted until the user password is entered.
At boot time, if a CD is detected in the CD-ROM drive or a diskette in drive A,
the system prompts for a password. When the password is entered, the
server boots from CD or diskette and disables the secure mode.
If there is no CD in the CD-ROM drive or diskette in drive A, the server boots
from drive C and automatically goes into secure mode. All enabled secure
mode features go into effect at boot time.
To leave secure mode: Enter the correct password(s).
Disable writing to disketteIn secure mode, the server will not boot from or write to a diskette unless a
password is entered.
To write protect access to diskette whether the server is in secure mode or
not, use the Setup main menu, Floppy Options, and specify Floppy Access as
read only.
continued
SBT2 Server Board Product Guide 17
Page 18
Table 2.Software Security Features (continued)
FeatureDescription
Set a time out period so
that keyboard and mouse
input are not accepted
Also, screen can be
blanked, and writes to
diskette can be inhibited
Specify and enable an inactivity time out period of from 1 to 120 minutes.
If no keyboard or mouse action occurs for the specified period, attempted
keyboard and mouse input will not be accepted.
The monitor display will go blank, and the diskette drive will be write protected
(if these security features are enabled through Setup).
To resume activity: Enter the correct password(s).
Control access to using
the SSU: set supervisor
password
To control access to setting or changing the system configuration, set an
supervisor password and enable it through Setup.
If both the supervisor and user passwords are enabled, either can be used to
boot the server or enable the keyboard and/or mouse, but only the supervisor
password will allow Setup to be changed.
To disable a password, change it to a blank entry or press CTRL-D in the
Change Password menu of the Supervisor Password Option menu found in
the Security Subsystem Group.
To clear the password if you cannot access Setup, change the Clear
Password jumper (see Chapter 5).
Control access to the
system other than SSU:
set user password
To control access to using the system, se t a user password and enable it
through Setup.
To disable a password, change it to a blank entry or press CTRL-D in the
Change Password menu of the User Password Option menu found in the
Security Su bsystem Group.
To clear the password if you cannot access Setup, change the Clear
Password jumper (see Chapter 5).
Boot without keyboardThe system can boot with or without a keyboard. During POST, before the
system completes the boot sequence, the BIOS automatically detects and
tests the keyboard if it is present and displays a message.
Specify the boot sequence The sequence that you specify in setup will determine the boot order. If
secure mode is enabled (a user password is set), then you will be prompted
for a password before the server fully boots. If secure mode is enabled and
the “Secure Boot Mode” option is also enabled, the server will fully boot but
will require a password before accepting any keyboard or mouse input.
18Description
Page 19
2Upgrading
Tools and Supplies Needed
• Phillips (cross head) screwdriver (#1 bit and #2 bit)
• Jumper removal tool or needle nosed pliers
• Pen or pencil
• Antistatic wrist strap and conductive foam pad (recommended)
Cautions
These warnings and cautions apply throughout this chapter. Only a technically qualified person
should configure the server board.
CAUTIONS
System power on/off: The power button DOES NOT turn off the system
AC power. To remove power from system, you must unplug the AC power
cord from the wall outlet. Make sure the AC power cord is unplugged before
you open the chassis, add, or remove any components.
Hazardous conditions, devices & cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the server and disconnect the power cord, telecommunications
systems, networks, and modems attached to the server before opening it.
Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) & ESD protection: ESD can damage
disk drives, boards, and other parts. We recommend that you perform all
procedures in this chapter only at an ESD workstation. If one is not
available, provide some ESD protection by wearing an antistatic wrist strap
attached to chassis groundany unpainted metal surfaceon your server
when handling parts.
ESD and handling boards: Always handle boards carefully. They can
be extremely sensitive to ESD. Hold boards only by their edges. After
removing a board from its protective wrapper or from the server, place the
board component side up on a grounded, static free surface. Use a
conductive foam pad if available but not the board wrapper. Do not slide
board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased
conductor that slips over two jumper pins. Some jumpers have a small tab on
top that you can grip with your fingertips or with a pair of fine needle nosed
pliers. If your jumpers do not have such a tab, take care when using needle
nosed pliers to remove or install a jumper; grip the narrow sides of the
19
Page 20
jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with
the function controlled by that jumper. Take care to grip with, but not
squeeze, the pliers or other tool you use to remove a jumper, or you may
bend or break the stake pins on the board.
Memory
Only PC133-compliant SDRAM is supported by the server board. Install from 64 MB to 4 GB of
registered memory, using up to four single- or double-banked DIMMs.
DIMMs must be installed in order from slot 1 to slot 4, no empty slots between installed DIMMs.
Slot 1 is the slot farthest from the processors.
Installed DIMMs must be the same speed and must all be registered. For a list of supported
memory, call your service representative or visit the Intel Support website:
If the server has been running, any installed processor and heat sink on
the processor board(s) will be hot. To avoid the possibility of a burn, be
careful when removing or installing server board components that are
located near processors.
CAUTIONS
Processor must be appropriate: You may damage the server if you
install a processor that is inappropriate for your server. Make sure your
server can handle a newer, faster processor (thermal and power
considerations). For exact information about processor interchangeability,
contact your customer service representative or visit the Intel Customer
Support website:
http://support.intel.com/support/motherboards/server/SBT2
Heat sink must be appropriate: You must use an Intel boxed processor
with one of the following product codes: BX80526KB866256,
BX80526KB1000256, BX80526KB8001M
ESD and handling processors: Reduce the risk of electrostatic
discharge (ESD) damage to the processor by doing the following: (1) Touch
the metal chassis before touching the processor or server board. Keep part of
your body in contact with the metal chassis to dissipate the static charge
while handling the processor. (2) Avoid moving around unnecessarily.
SBT2 Server Board Product Guide 21
Page 22
Adding or Replacing a Processor
If you are adding a second processor to your system, you must first remove the termination card
from the secondary processor slot. The second processor must be compatible with the first
processor (within one stepping, sa me voltage, see the Int el suppo rt w ebs ite fo r speci fics).
1. Observe the safety and ESD precautions at the beginning of this chapter and the additional
cautions given here.
2. Remove the side cover (see your system or chassis documentation for instructions).
3. Remove the top piece of epac covering the processors
A
22Upgrading
OM10615
A. Epac
Figure 4. Remove the Top Epac
Page 23
4.Remove the auxiliary cooling fans from their brackets. Do not disconnect them from the board.
A
A. Fans
Figure 5. Remove Auxiliary Fans
OM10419
SBT2 Server Board Product Guide 23
Page 24
5.Remove the bottom piece of foam epac. It lifts straight out; do not tilt it.
A
A. Epac
Figure 6. Remove Bottom Epac
OM10616
24Upgrading
Page 25
6.Lift the plastic ejectors on the processor or termination card to disengage the retention wires.
A
B
OM10617
A. Retention wires
B. Ejectors
Figure 7. Disengage Retention Wires
7.Pull the processor or termination card from the system.
SBT2 Server Board Product Guide 25
Page 26
8. Clip two plastic ejectors (Figure 8, A) to the new processor (Figure 8, B).
9. Slide the new processor into the processor slot. Push down firmly, with even pressure on both
sides of the top, until the processor is seated in the processor connector on the server board.
A
B
C
A. Ejectors
B. Processor
C. Retention wires
D. Retention Mechanism
Figure 8. Installing a Processor
D
OM10413
26Upgrading
Page 27
10.Move the retention wires over the plastic ejectors to hold the processor in place.
A
B
OM10415
A. Ejectors
B. Retention wires
Figure 9. Engage Retention Wires
11. After you have installed the processor(s), you must configure the speed jumpers. See the CPU
Clock Speed table on page 67.
SBT2 Server Board Product Guide 27
Page 28
12. Place the bottom piece of epac into the chassis as shown. Make sure it is fully seated in the
chassis. If it isn’t, the cover will not fit properly.
✏ NOTE
The epac drops straight in. Do not tilt it in; trying to straighten in will break
the epac.
A
28Upgrading
OM10425
A. Epac
Figure 10. Install Bottom Epac
Page 29
13. Clip the fans into place. Make sure that the label on the fan faces the air holes in the ch as sis
(away from the processors).
A
A. Fans
Figure 11. Install Fans
OM10419
SBT2 Server Board Product Guide 29
Page 30
14.Place the top piece of foam epac into the chassis as shown.
A. Epac
Figure 12. Install Top Epac
A
OM10420
30Upgrading
Page 31
Replacing the Back up Battery
The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the
absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer
service representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with
the same or equivalent type recommended by the equipment
manufacturer. Discard used batteries according to manufacturer’s
instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri
som anbefalt av apparatfabrikanten. Brukt batteri returneres
apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller
en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera
använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty
paristo valmistajan ohjeiden mukaisesti.
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Open the chassis.
3. Insert the tip of a small flat bladed screwdriver, or equivalent, under the tab in the plastic
retainer. Gently push down on the screwdriver to lift the battery.
4. Remove the battery from its socket.
5. Dispose of the battery according to local ordinance.
6. Remove the new lithium battery from its package, and, being careful to observe the correct
polarity, insert it in the battery socket.
7. Reinstall the plastic retainer on the lithium battery socket.
8. Close the chassis.
9. Run Setup to restore the configuration settings to the RTC.
SBT2 Server Board Product Guide 31
Page 32
32Upgrading
Page 33
3Configuration Software and Utilities
This chapter describes the Power On Self Test (POST) and server configuration utilities. The table
below briefly describes the utilities.
Table 3.Configuration Utilities
UtilityDescription and brief procedurePage
BIOS SetupIf the system does not have a diskette drive, or the drive is disabled or
misconfigured, use Setup to enable it.
Or, you can move the CMOS jumper on the server board from the default
setting (Protect CMOS memory) to the Clear setting; this will allow most server
configurations to boot. For the procedure to do this, see the section “CMOS
Jumper” in Chapter 5 in this manual. Then run the SSU to configure the
server.
System Setup
Utility (SSU)
FRUSDR Load
Utility
BIOS Upgrade
Utility
Firmware Update
Utility
Using the Adaptec
SCSI Utility
Use for viewing and clearing the system event log, viewing th e system
management FRU information, or viewing the system management SDR
repository.
Use to update the Field Replacement Unit (FRU), Sensor Data Record (SDR),
and SM BIOS (SMB) flash components.
Use to upgrade the BIOS.55
Use to update the Firmware.56
Use to configure or view the settings of the SCSI host adapters and onboard
SCSI devices in the server.
35
44
50
56
Hot Keys
Use the keyboard’s numeric pad to enter numbers and symbols.
Table 4.Hot Keys
To do this:Press these keys
Clear memory and reload the operating
systemthis is a system reset.
Secure your system immediately.<Ctrl+Alt>+hotkey (Set your hot key combination with
<Ctrl+Alt+Del>
Setup.)
33
Page 34
Power-On Self Test (POST)
Each time you turn on the system, POST starts running. POST checks the server board, processor,
memory, keyboard, and most installed peripheral devices. During the memory test, POST displays
the amount of memory that it is able to access and test. The length of time needed to test memory
depends on the amount of memory installed. POST is stored in flash memory.
1. Turn on your video monitor and server. After a few seconds POST begins to run.
2. After the memory test, these screen prompts and messages appear:
Press <F2> key if you want to run SETUP
3. If you do not press <F2> and do NOT have a device with an operating system loaded, the
above message remains for a few seconds while the boot process continues, and the system
beeps once. Then this message appears:
Operating system not found
If you do not press <F2> and DO have an operating system loaded, the boot process continues,
and this message appears:
Press <Ctrl><A> to enter SCSI Utility
4. Press <Ctrl+A> if there are SCSI devices installed. When the utility opens, follow the
displayed instructions to configure the onboard SCSI host adapter settings and to run the
SCSI utilities. Also see “Using the Adaptec SCSI Utility” on page 56. If you do not enter the
SCSI utility, the boot process continues.
5. Press <Esc> during POST to pop up a boot menu when POST finishes. From this menu you
can choose the boot device or enter BIOS Setup.
After POST completes, the system beeps once.
What appears on the screen after this depends on whether you have an operating system loaded and
if so, which one.
If the system halts before POST completes running, it emits a beep code indicating a fatal system
error that requires immediate attention. If POST can display a message on the video display screen,
it causes the speaker to beep twice as the message appears.
Note the screen display and write down the beep code you hear; this information is useful for your
service representative. For a listing of beep codes and error messages that POST can generate, see
the “Solving Problems” chapter in this manual.
34Configuration Software and Utilities
Page 35
Using BIOS Setup
This section describes the BIOS Setup options. Use Setup to change the server configuration
defaults. You can run Setup with or without an operating system being present. Setup stores most
of the configuration values in battery backed CMOS; the rest of the values are stored in flash
memory. The values take effect when you boot the server. POST uses these values to configure
the hardware; if the values and the actual hardware do not agree, POST generates an error message.
You must then run Setup to specify the correct configuration.
Record Your Setup Settings
If the default values ever need to be restored (after a CMOS clear, for example), you must run
Setup again. Referring to the worksheets could make your task easier.
If You Cannot Access Setup
If the diskette drive is misconfigured so that you cannot access it to run a utility from a diskette,
you may need to clear CMOS memory. You will need to open the server, change a jumper setting,
use Setup to check and set diskette drive options, and change the jumper back. For a step-by-step
procedure, see Chapter 5, under the heading, “CMOS Jumper.”
Starting Setup
You can enter and start Setup under several conditions:
• When you turn on the server, after POST completes the memory test
• When you reboot the server by pressing <Ctrl+Alt+Del> while at the DOS operating system
prompt
• When you have moved the CMOS jumper on the server board to the “Clear CMOS” position
(enabled); for the procedure, see Chapter 5, under the heading “CMOS Jumper”
In the three conditions listed above, after rebooting, you will see this prompt:
Press <F2> to enter SETUP
NOTE
✏
If the BIOS setup option “POST Diagnostic Screen” is enabled (Default),
you will not see the message “Press <F2> to enter SETUP”. This message is
hidden by the Manufacturer’s Splash screen. To see the message, press the
<ESC> key while the splash screen is displayed. This will temporarily
disable the splash screen allowing you to see the message.
In a fourth condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not
the <F2> prompt:
Warning: cmos checksum invalid
Warning: cmos time and date not set
In this condition, the BIOS will load default values for CMOS and attempt to boot.
SBT2 Server Board Product Guide 35
Page 36
Setup Menus
To:Press
Get general help<F1> or <Alt+H>
Move between menus
Go to the previous item
Go to the next Item
Change the value of an item+ or Select an item or display a submenu<Enter>
Leave a submenu or exit Setup<Esc>
Reset to Setup defaults<F9>
Save and exit Setup<F10>
When you see this:What it means
On screen, an option is shown but you
cannot select it or move to that field.
On screen, the phrase Press Enter
appears next to the option.
The rest of this section lists the features that display onscreen after you press <F2> to enter Setup.
Not all of the option choices are described, because (1) a few are not user selectable but are
displayed for your information, and (2) many of the choices are relatively self explanatory.
← →
↑
↓
You cannot change or configure the option in that menu screen.
Either the option is autoconfigured or autodetected, or you must
use a different Setup screen.
Press <Enter> to display a submenu that is either a separate full
screen menu or a popup menu with one or more choices.
Main Menu
You can make the following selections on the Main Menu itself. Use the submenus for other
selections.
FeatureChoicesDescription
System TimeHH:MM:SSSets the system time.
System DateMM/DD/YYYYSets the system date .
Diskette ANot Installed
1.44/1.25 MB
Diskette BNot Installed
1.44/1.25 MB
Hard Disk Pre-Delay
Primary MasterEnters submenu.
Primary SlaveEnters submenu.
Processor SpeedN/AThis field is informational only.
Cache RAMN/AThis field is informational only.
System MemoryN/AThis field is informational only.
Extended MemoryN/AThis field is informational only.
LanguageEnglish (US)
Disabled
Enabled
Français
Deutsch
Italiano
Español
Selects the diskette type.
Selects the diskette type.
Adds a delay before first access of the hard drive.
Selects which language BIOS displays.
36Configuration Software and Utilities
Page 37
Primary Master/Slave Submenu
FeatureChoicesDescription
TypeUser
Auto
CD ROM
ATAPI
Removable
Multimode TransfersDisabled
Enabled
LBA Mode Control
32 Bit I/ODisabled
Transfer ModeTransfer Mode is automatically selected
Ultra DMA ModeDMA mode is automatically selected
Disabled
Enabled
Enabled
User defines parameters
Auto type selection
CD ROM is installed
Removable disk is installed
Enables large block addressing
Advanced Menu
You can make the following selections on the Advanced Menu itself. Use the submenus for the
three other selections that appear on the Advanced Menu.
Select Yes if you want to clear the server configuration
data during the next boot. The system automatically resets
this field to No during the next boot.
Select PnP O/S if you are booting a Plug and Play capable
operating system.
SBT2 Server Board Product Guide 37
Page 38
Memory Reconfiguration Submenu
FeatureChoicesDescription
DIMM Group #1
Status
DIMM Group #2
Status
DIMM Group #3
Status
DIMM Group #4
Status
Clear DIMM
Error
DIMM Error
Pause
N/AThis field is informational only.
N/AThis field is informational only.
N/AThis field is informational only.
N/AThis field is informational only.
Press <Enter>Clears the memory error status.
Enabled
Disabled
Enabled causes the system to pause at the end of POST if a
memory error occurred.
CPU Reconfiguration Submenu
FeatureChoicesDescription
CPU #1 StatusN/AThis field is informational only.
CPU #2 StatusN/AThis field is informational only.
Clear CPU
278, IRQ 5
278, IRQ 7
3BC, IRQ 5
3BC, IRQ 7
AutoAuto forces BIOS to configure the port.
Parallel ModeOutput only
Bi-directional
EPP
ECP, DMA 1
ECP, DMA 3
Diskette ControllerDisabled
Enabled
MouseDisabled
Enabled
Auto Detect
SCSI ControllerDisabled
Enabled
LAN ControllerDisabled
Enabled
VGA ControllerEnabled
Disabled
USB ControllerDisabled
Enabled
Selects parallel port mode.
Enables onboard diskette controller.
Enables the mouse.
Enables the onboard SCSI controller.
Enables the onboard LAN controller.
Enables the on board VGA controller.
Enables the onboard USB controller.
SBT2 Server Board Product Guide 39
Page 40
PCI Device Submenu
FeatureChoicesDescription
PCI IRQ 1-14Disabled
Option ROM Submenu
FeatureChoicesDescription
On Board SCSIEnabled
On Board LANEnabled
PCI Slot1-7Enabled
Auto Select
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
IRQ9
IRQ10
IRQ11
IRQ12
Disabled
Disabled
Disabled
Configure which IRQ resource to allocate for 14 interrupt
signal in PCI bus.
Enables option ROM scan of the onboard SCSI chip.
There are 2 SCSI channels that are controlled by the same
option ROM.
Enables option ROM scan of the onboard LAN controller.
Enables option ROM scan of the PCI slots.
Numlock Submenu
FeatureChoicesDescription
NumlockAuto
Key ClickDisabled
Keyboard auto-repeat rate2/sec
Keyboard auto-repeat delay1/4 sec
On
Off
Enabled
6/sec
10/sec
13.3/sec
18.5/sec
21.8/sec
26.7/sec
30/sec
1/2 sec
3/4 sec
1 sec
Selects the power on state for Num Lock.
Enables or disables the audible key click.
Sets the numbers of time per second a key will repeat
while it is held down.
Sets the delay before a key starts to repeat when it is
held down.
40Configuration Software and Utilities
Page 41
Security Menu
You can make the following selections on the Security Menu itself. Enabling the Supervisor
Password field requires a password for entering Setup. The passwords are not case-sensitive.
FeatureChoicesDescription
Supervisor Password isClear
Set
User Password isClear
Set
Set Supervisor
Password
Set User PasswordPress EnterWhen the <Enter> key is pressed, you are prompted for a
Password on BootDisabled
Secure ModeEnters Submenu. This is only available if both the user and
Diskette Acces sEveryone
Power Switch MaskUnmasked
Option ROM Menu
Mask
Processor serial numberDisabled
Press EnterWhen the <Enter> key is pressed, you are prompted for a
Enabled
Supervisor
Masked
Unmasked
Masked
Enabled
Status only; user cannot modify.
Status only; user cannot modify. Once set, this can be disabled
by setting it to a null string, or by clearing password jumper on
server board.
password; press ESC key to abort. Once set, this can be cleared
by setting it to a null string, or by clearing password jumper on
server board (see Server Board Jumpers in Chapter 5).
password; press ESC key to abort. Once set, this can be cleared
by setting it to a null string, or by clearing password jumper on
server board (see Server Board Jumpers in Chapter 5).
Requires password entry before boot. System will remain in
secure mode until password is entered. Password on Boot takes
precedence over Secure Mode Boot.
supervisor passwords are set.
Limits the use of the diskette drive to system supervisors.
Supervisor password must be set to enable this feature.
If set to Masked, you cannot turn off the power using the power
switch after rebooting the OS.
If set to masked, you cannot enter the Adaptec BIOS
configuration by pressing CNTL A.
Enables the processor serial number feature.
Secure Mode Submenu
FeatureChoicesDescription
Secure Mode TimerDisabled
Secure Mode Hot KeyDisabled
Ctrl-Alt-[ ][ ]
Secure Mode BootDisabled
Floppy Write ProtectDisabled
1 min
2 min
5 min
10 min
20 min
1 hr
2 hr
Enabled
[0-9, A, B, ..., Z]
Enabled
Enabled
Period of keyboard/PS/2 mouse inactivity specified for secure
mode to activate. A password is required for secure mode to
function. Cannot be enabled unless at least one password is
enabled.
Enables Quicklock feature Cannot be enabled unless at least
one password is enabled.
Key assigned to start the Quicklock feature.
System will boot in secure mode. You must enter a
password to unlock the system. Cannot be enabled unless at
least one password is enabled.
When secure mode is activated, the diskette drive is write
protected. You must enter a password to disable. Cannot be
enabled unless at least one password is enabled.
SBT2 Server Board Product Guide 41
Page 42
System Hardware Menu
You can make the following selections on the Server Menu itself.
FeatureChoicesDescription
Wake On EventEnters submenu.
AC-LINKStay Off
Last State
Power On
Error Log InitializationPress <Enter> keyClears the SEL.
Console RedirectionEnters submenu.
Wake on Event Submenu
FeatureChoicesDescription
Wake On LAN
Wake On RingDisabled
†
Disabled
Enabled
Enabled
Console Redirection Submenu
Sets what happens when AC power is lost and restored.
Stay Off means the server will not power up. Last State
means the server will power up if it was powered when
AC was lost. Power On means the server will always
power up when AC is regained.
Enables remote power on via network command.
Enables remote power on via serial port.
FeatureChoicesDescription
COM Port AddressDisabled
Baud Rate57.6K
Flow ControlNo Flow Control
Console ConnectionDirect
Boot Menu
FeatureDeviceDescription
Boot Diagnostics ScreenEnabled
Boot Device PriorityEnters submenu.
Hard DriveEnters submenu.
Removable DevicesEnters submenu.
Serial Port 2 (3F8/IRQ4)
Serial Port 2 (2F8/IRQ3)
19.2k
XON/XOFF
Via modem
Disabled
When enabled, console redirection uses the I/O port
specified. All keyboard/mouse and video will be
directed to this port. This is designed to be used only
under DOS in text mode.
When console redirection is enabled, specifies the baud
rate to be used.
None disallows flow control.
XON/XOFF is software-flow control.
Sets what the console connection is.
42Configuration Software and Utilities
Page 43
Boot Device Priority Submenu
Use the up or down arrow keys to select a device; then press the <+> or <-> keys to move the
device higher or lower in the boot priority list.
Boot PriorityDeviceDescription
1. Diskette DriveAttempts to boot from the diskette drive.
2. ATAPI CD-ROM DriveAttempts to boot from an ATAPI CD-ROM drive.
3. Hard DriveAttempts to boot from a hard drive device.
4. Intel UNDI, PXE-2.0Attempts to boot from a network connection.
Requires the presence of a PXE server.
Hard Drive Submenu
ChoicesDescription
Hard Drive 1Autodetected hard drive.
Hard Drive 2Autodetected hard drive.
Hard Drive 3Autodetected hard drive.
Bootable Add in CardAutodetected Add-in card.
Removable Devices
ChoicesDescription
Diskette AAutodetected diskette drive.
Exit Menu
You can make the following selections on the Exit Menu. Select an option using the up or down
arrow keys; then press <Enter> to execute the option. Pressing <Esc> does not exit this menu.
You must select one of the items from the menu or menu bar to exit.
ChoicesDescription
Save Changes & ExitExits after writing all modified Setup item values to NVRAM.
Exit Without Saving ChangeExits leaving NVRAM unmodified.
Get Default ValuesLoads default values for all Setup items.
Load Previous ValuesLoads values of all Setup items from previously saved custom defaults.
Save ChangesWrites all Setup item values to NVRAM.
SBT2 Server Board Product Guide 43
Page 44
Using the System Setup Utility
The System Setup Utility (SSU) is on the Server Board Resource software CD shipped with the
server board. The SSU provides a graphical user interface (GUI) over an extensible framework for
server configuration. The SSU framework supports the following functions and capabilities:
• allows viewing and clearing of the system’s critical event log
• allows the viewing of the system management FRU information
• allows the viewing of the system management SDR repository
What You Need to Do
The SSU may be run directly from the Server Resource CD (by booting the server system to the CD
and selecting “Utilities”) or from a set of DOS diskettes.
If you choose to run the SSU from a set of DOS diskettes, you must create the SSU diskettes from
the Server Resource CD by booting to the CD and selecting “Create Diskettes.” Alternatively, if
you have a Windows 95 or Windows NT workstation, you can insert the CD into that system and
create diskettes from the “Utilities” menu of the graphical user interface.
If your diskette drive is disabled, or improperly configured, you must use the flash resident Setup
utility to enable it so that you can use the SSU. If necessary, you can disable the drive after you
exit the SSU. Information entered using the SSU overrides any entered using Setup.
Running the SSU from the CD
Running the ssu.bat file provided on the SSU media starts the SSU. If the server boots directly
from the SSU media, the ssu.bat file is automatically run. If it boots from a different media, the
SSU can be started manually or by another application. When the SSU starts in the local execution
mode (the default mode), the SSU accepts input from the keyboard and/or mouse. The SSU
presents a VGA based Graphical User Interface (GUI) on the primary monitor.
The SSU runs from writable, nonwritable, removable, and nonremovable media. If the SSU is run
from nonwritable media, user preference settings (such as screen colors) can not be saved.
The SSU supports the ROM-DOS V6.22 operating system. It may run on other ROM-DOScompatible operating systems but they are not supported. The SSU will not operate from a “DOS
box” running under an operating system such as Windows.
44Configuration Software and Utilities
Page 45
Running the SSU Remotely via an Emergency Management Card
Using graphical hardware redirection via the emergency management card 2, you can see the SSU
Console in VGA graphics mode, control the mouse, and control the keyboard from a local system
connected to a remote server by a network or modem.
The emergency management card 2 provides video memory, keyboard, and mouse redirection
support. Video memory and user input are sent to a remote location through either a modem or
Ethernet link and displayed by the Remote Control console. This solution requires an emergency
management card 2 card installed in the remote server and the Remote Control software available
on the local system. The SSU will execute exclusively on the remote server. Any files required for
the SSU to execute must be on the remote server.
Starting the SSU
SSU consists of a collection of task oriented modules plugged into a common framework called the
Application Framework (AF). The Application Framework provides a launching point for
individual tasks and a location for setting customization information. For full functionality the SSU
requires the availability of the AF.INI, AF.HLP, plus any .ADN files and their associated .HLP and
.INI files.
1. Turn on your video monitor and your system.
2. There are two ways to start the SSU.
a. After creating set of three SSU diskettes from the CD: Insert the first SSU diskette in
drive A, and press the reset button or <Ctrl+Alt+Del> to reboot your server from the
diskette. Insert the second diskette when prompted.
b. Directly from the Server Resource CD: Insert the Server Resource CD into your
CD ROM drive and press the reset button or <Ctrl-Alt-Del> to reboot. When prompted to
do so, press <F2> to enter BIOS Setup. From the Boot Menu, select the Boot Device
Priority option and then select CD-ROM as your primary boot device. Save those settings
and exit BIOS Setup. The server will boot from the CD-ROM and display a menu of
options. Follow the instructions in the menu to start the SSU.
3. When the SSU title appears on the screen, press <Enter> to continue.
4. The mouse driver loa ds if it is avai lab le ; press <Enter > to continu e.
5. This message appear s:
Please wait while the Application Framework loads....
6. When the main window of the SSU appears, you can customize the user interface before
continuing.
SBT2 Server Board Product Guide 45
Page 46
Figure 13. System Setup Utility Main Window
46Configuration Software and Utilities
Page 47
Customizing the SSU
The SSU lets you customize the user interface according to your preferences. The AF sets these
preferences and saves them in the AF.INI file so that they take effect the next time you start the
SSU. There are four user customizable settings:
•Color - this button lets you change the default colors associated with different items on the
screen with predefined color combinations. The color changes are instantaneous.
• Mode - this button lets you set the desired expertise level.
novice
intermediate
expert
The expertise level determines which tasks are visible in the Available Tasks section and what
actions each task performs. For a new mode setting to take effect, you must exit the SSU and
restart it.
•Language - this button lets you change the strings in the SSU to strings of the appropriate
language. For a new language setting to take effect, you must exit the SSU and restart it.
•Other - this button lets you change other miscellaneous options in the SSU. The changes take
effect immediately.
To change the interface default values:
Use the mouse to click on the proper button in the Preferences section of the SSU Main
window.
or
Use the tab and arrow keys to highlight the desired button, and press the spacebar or <Enter>.
or
Access the menu bar with the mouse or hot keys (Alt + underlined letter).
NOTE
✏
If you run the SSU from nonwritable media (like a CD-ROM), these
preferences will be lost when you exit the SSU.
Launching a Task
It is possible to have many tasks open at the same time, although so me task s may require complete
control to avoid possible conflicts. The tasks achieve complete control by keeping the task as the
center of operation until you close the task window.
To launch a task:
In the SSU Main window, double-click on the task name under Available Tasks to display the
main window for the selected task.
or
Highlight the task name, and click on OK.
or
Use the tab and arrow keys to highlight the desired button, and press the spacebar or <Enter>.
SBT2 Server Board Product Guide 47
Page 48
SEL Manager Add-in
Clicking on the SEL Manager Add-in task brings up the Server Event Log (SEL) viewer. You can
load and view the current SEL data stored in the BMC, save the currently loaded SEL data to a file,
view previously saved SEL data, or clear the SEL.
When the SEL Manager is first invoked, it loads the System Event Log entries from the server. If
there are no SEL entries, a message box is displayed.
The SEL Manager main window is based on a multi-column format. All SEL entries are displayed
in this window, one system event per row. Each column can be sorted by clicking on the column
heading. The event number is tied to the particular event even if any other column sorts the list.
The following keyboard keys are used to scroll the event columns. The F4 key shifts the event
columns left, while the F5 key shifts the event columns right.
The SEL Manager has the following menus:
File Menu
The File menu has the following options:
• Open Open a SEL data file for viewing.
• Save As… Save the currently loaded SEL data to a file.
• Exit Quits the SEL Viewer.
SEL Menu
The SEL menu has the following options:
• Properties Displays information about the SEL. These fields are display only.
• Clear SEL Clears the SEL entries from the NV storage area and from the SEL Manager main
window.
•Reload Reloads the SEL entries from the NV storage area.
Help
The Help menu has the following option:
•Help Topics Displays the help information for the SEL Manager Add-in.
SDR Manager Add-in
Clicking on the SDR Manager Add-in task brings up the Sensor Data Record (SDR) viewer. You
can load and view the current SDR data stored in the NV storage area, save the currently loaded
SDR data to a file, or view previously saved SDR data. The SDR Manager main window provides
access to all the features of the add-in through menus. The F4 key shifts the SDR columns left,
while the F5 key shifts the SDR columns right.
48Configuration Software and Utilities
Page 49
The SDR Viewer has the following menus:
File Menu
The File menu has the following options:
• Open Open a SDR data file for viewing.
• Save As… Save the currently loaded SDR data to a file.
• Exit Quits the SDR Viewer.
SDR Menu
The SDR menu has the following options:
• Properties Displays SDR information from the BMC. These fields are display only.
• Reload Reloads the SDR entries from the server.
Help
The Help menu has the following option:
•Help Topics Displays the help information for the SDR Manager Add-in.
FRU Manager Add-in
Clicking on the FRU Manager Add-in task brings up the Sensor Data Record (FRU) viewer. You
can load and view the current FRU data stored in the NV storage area, save the currently loaded
FRU data to a file, or view previously saved FRU data. The FRU Manager main window provides
access to all the features of the add-in through menus. The F4 key shifts the FRU columns left,
while the F5 key shifts the FRU columns right.
The FRU Viewer has the following menus:
File Menu
The File menu has the following options:
• Open Open a FRU data file for viewing.
• Save AS… Save the currently loaded FRU data to a file.
• Exit Quits the FRU Viewer.
FRU Menu
The FRU menu has the following options:
• Properties Displays FRU information from the BMC. These fields are display only.
• Reload Reloads the FRU entries from the server.
Help
The Help menu has the following option:
•Help Topics Displays the help information for the FRU Manager Add-in.
SBT2 Server Board Product Guide 49
Page 50
Exiting the SSU
Exiting the SSU causes all windows to close.
1. Exit the SSU by opening the menu bar item File in the SSU Main window.
2. Click on Exit.
or
Highlight Exit, and press <Enter>.
FRUSDR Load Utility
The Field Replacement Unit (FRU) and Sensor Data Record (SDR) Load Utility is a DOS-based
program used to update the server management subsystem’s product level FRU, SDR, and the SM
BIOS (SMB) nonvolatile storage components (EEPROMs). The load utility
• discovers the product configuration based on instructions in a master configuration file
• displays the FRU information
• updates the nonvolatile storage device (EEPROM) associated with the Baseboard Management
Controller (BMC) that holds the SDR and FRU area
• updates the SMB area located in the BIOS nonvolatile storage device
• generically handles FRU devices that may not be associated with the BMC
When to Run the FRUSDR Load Utility
You should run the FRUSDR Load Utility each time you upgrade or replace the hardware in your
server, excluding add-in boards, hard drives, and RAM. For example, if you replace an array of
fans, you need to run the utility. It programs the sensors that need to be monitored for server
management.
Because the firmware must reload to properly initialize the sensors after programming, turn the
server off and remove the AC power cords from the server. Wait approximately 30 seconds, and
reconnect the power cords.
What You Need to Do
The FRUSDR Load Utility may be run directly from the Configuration Software CD or from a
diskette you create from the CD. It can be extracted from the CD by booting to the CD and
selecting “Make Diskettes” or by inserting the CD into a PC running Windows 95 or NT and
selecting the “Utilities” secti on.
NOTE
✏
If your diskette drive is disabled, or improperly configured, you must use
BIOS Setup to enable it. If necessary, you can disable the drive after you are
done with the FRUSDR utility.
50Configuration Software and Utilities
Page 51
How You Use the FRUSDR Load Utility
†
This utility is compatible with ROM-DOS Ver. 6.22, MS-DOS
utility accepts CFG, SDR and FRU load files. The executable file for the utility is frusdr.exe. The
utility requires the following supporting files:
• one or more .fru files describing the system’s field replaceable units
• a .cfg file describing the system configuration
• a .sdr file describing the sensors in the system
frusdrIs the name of the utility.
/? or /hDisplays usage information.
/d {smb, fru, sdr}Only displays requested area.
/cfg filename.cfgUses custom CFG file.
/pPause between blocks of data.
Parsing the Command Line
Ver. 6.22, and later versions. The
The FRUSDR Load Utility allows only one command line function at a time. A command line
function may consist of two parameters; for example, cfg filename.cfg. Any invalid parameters
result in displaying an error message and exiting the program. You can use either a slash (/) or a
minus sign (-) to specify command line options. The /p flag may be used in conjunction with any
of the other options.
Displaying Usage Information
When the utility is run with the /? or /h command line flags, the following message is displayed:
FRU & SDR Load Utility Version 4.0
Usage:frusdrIs the name of the utility.
/? Or /hDisplays usage information.
/d {smb,fru,sdr}Only displays requested area.
/cfg filename.cfgUses custom CFG file.
/pPause between blocks of data.
Displaying a Given Area
When the utility is run with the /d SMB, /d FRU, or /d SDR command line flag, the indicated area
is displayed. Each area represents a sensor; one sensor for each instrumented device in the server.
If the given display function fails because of an inability to parse the data present or a hardware
failure, the utility displays an error message and exits.
SBT2 Server Board Product Guide 51
Page 52
Displaying SM BIOS Area
The SM BIOS area is displayed in ASCII format when the field is ASCII or as a number when the
field is a number. Each SM BIOS area displayed is headed with the SM BIOS area designated
name. Each field has a field name header followed by the field in ASCII or as a number.
Displaying FRU Area
The FRU area is displayed in ASCII format when the field is ASCII or as a number when the field
is a number. Each FRU area displayed is headed with the FRU area designated name. Each field
has a field name header followed by the field in ASCII or as a number. The Board, Chassis, and
Product FRU areas end with an END OF FIELDS CODE that indicates there is no more data in this
area. The Internal Use area is displayed in hex format, 16 bytes per line.
Displaying SDR Area
The SDR nonvolatile storage area is displayed in the following hex format. The data is separated
by a Sensor Record Number X header, where X is the number of that sensor record in the
SDR area. The next line after the header is the sensor record data in hex format delineated by
spaces. Each line holds up to 16 bytes. The data on each line is followed by the same data in
ASCII format; nonprintable characters are substituted by a period (.).
Using Specified CFG File
The utility can be run with the command line parameter of -cfg filename.cfg. The filename can be
any DOS accepted, eight-character filename string. The utility loads the specified CFG file and
uses the entries in the configuration file to probe the hardware and to select the proper SDRs to load
into nonvolatile storage.
Displaying Utility Title and Version
The utility displays its title:
FRU & SDR Load Utility, Version 4.0
Where X.XX is the revision number for the utility.
Configuration File
The configuration file is in ASCII text. The utility executes commands formed by the strings
present in the configuration file. These commands cause the utility to perform various tasks needed
to ultimately load the proper SDRs into the nonvolatile storage of the BMC and possibly generic
FRU devices. Some of the commands may be interactive and require you to make a choice.
Prompting for Product Level FRU Information
Through the use of a Configuration File, the utility may prompt you for FRU information.
Filtering Sensor Data Record From the SDR File
The MASTER.SDR file has all the possible SDRs for the system. These records may need to be
filtered based on the current product configuration. The configuration file directs the filtering of
the SDRs.
52Configuration Software and Utilities
Page 53
Updating the SDR Nonvolatile Storage Area
After the utility validates the header area of the supplied SDR file, it updates the SDR repository
area. Before programming, the utility clears the SDR repository area. The SDR file is loaded via
the .cfg File. Then the utility filters all tagged SDRs depending on the product configuration set in
the Configuration File. Nontagged SDRs are automatically programmed. The utility also copies all
written SDRs to the SDR.TMP file. It contains an image of what was loaded, and the TMP file is
also useful for debugging the server.
Updating FRU Nonvolatile Storage Area
After the configuration is determined, the utility updates the FRU nonvolatile storage area. First it
verifies the Common Header area and checksum from the specified FRU file. The Internal Use
Area is read out of the specified .FRU file and is programmed into the nonvolatile storage. The
Chassis, Board, Product and MultiRecord areas are read out of the specif ied .FRU file, if they exist,
then those areas are programmed into the FRU nonvolatile storage. All the areas are also written to
the FRU.TMP file, which is useful for debugging the server.
Updating SMB FRU Nonvolatile Storage Area
After programming the BMC FRU area, the corresponding SMB fields are automatically updated
when the server is re-booted.
Cleaning Up and Exiting
If an update was successfully performed, the utility displays an appropriate message and then exits
with a DOS exit code of zero.
If the utility fails, it immediately exits with an error message and a non-zero DOS exit code.
Upgrading the BIOS
Preparing for the Upgrade
Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings,
obtaining the upgrade utility, and making a copy of the current BIOS.
Recording the Current BIOS Settings
1. Boot the computer and press <F2> when you see the message:
Press <F2> Key if you want to run SETUP
2. Write down the current settings in the BIOS Setup program.
NOTE
✏
Do not skip step 2. You will need these settings to configure your computer
at the end of the procedure.
SBT2 Server Board Product Guide 53
Page 54
Obtaining the Upgrade Utility
You can upgrade to a new version of the BIOS using the new BIOS files and the BIOS upgrade
utility, PHLASH.EXE. You can obtain the BIOS upgrade file and the PHLASH.EXE utility
through your computer supplier or from the Intel Customer Support website:
Please review the instructions distributed with the upgrade utility before
attempting a BIOS upgrade.
This upgrade utility allows you to:
• Upgrade the BIOS in flash memory.
• Update the language section of the BIOS.
The following steps explain how to upgrade the BIOS.
Creating a Bootable Floppy Diskette
1. Use a DOS or Windows 95 system to create the floppy disk.
2. Insert a floppy disk in floppy drive A.
3. At the C:\ prompt, for an unformatted floppy disk, type:
format a:/s
or, for a formatted floppy disk, type:
sys a:
4. Press <Enter>
Creating the BIOS Upgrade Floppy Diskette
The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to
upgrade the BIOS.
1. Copy the BIOS upgrade file to a temporary directory on your hard disk.
2. From the C:\ prompt, change to the temporary directory.
3. To extract the file, type the name of the BIOS upgrade file, for example:
10006BI1.EXE
4. Press <Enter>. The extracted file contains the following files:
LICENSE.TXT
README.TXT
BIOS.EXE
5. Read the LICENSE.TXT file, which contains the software license agreement and the
README.TXT file, which contains the instructions for the BIOS upgrade.
54Configuration Software and Utilities
Page 55
6. Insert the bootable floppy disk into drive A.
7. To extract the BIOS.EXE file to the floppy disk, change to the temporary directory that holds
the BIOS.EXE file and type:
BIOS A:
8. Press <Enter>.
9. The floppy disk now holds the BIOS upgrade and recovery files.
Upgrading the BIOS
1. Boot the computer with the floppy disk in drive A. The BIOS upgrade utility screen appears.
2. When you are prompted to reboot the server, remove the floppy disk and reboot.
3. As the computer boots, check the BIOS identifier (version number) to make sure the upgrade
was successful.
4. To enter the Setup program, press <F2> when you see the message:
Press <F2> Key if you want to run SETUP
5. For proper operation, load the Setup program defaults.
6. Set the options in the Setup program to the settings you wrote down before the BIOS upgrade.
7. Save the settings and exit.
Recovering the BIOS
It is unlikely that anything will interrupt the BIOS upgrade; however, if an interruption occurs, the
BIOS could be damaged. The following steps explain how to recover the BIOS if an upgrade fails.
The following procedure use recovery mode for the Setup program.
NOTE
✏
Because of the small amount of code available in the nonerasable boot block
area, there is no video support. You will not see anything on the screen
during the procedure. Monitor the procedure by listening to the speaker and
looking at the floppy drive LED.
1. Turn off all peripheral devices connected to the computer. Turn off the computer.
2. Remove the computer cover.
3. Locate jumper block 3N7.
4. Jumper pins 9-10 (see Figure 14 on page 67).
5. Insert the bootable BIOS upgrade floppy disk into floppy drive A.
6. Replace the cover, turn on the computer, and allow it to boot. The recovery process will take a
few minutes.
7. Listen to the speaker.
8. Two beeps and the end of activity in drive A indicate successful BIOS recovery.
9. A series of continuous beeps indicates failed BIOS recovery.
10. If recovery fails, return to step 1 and repeat the recovery process.
11. If recovery is successful, turn off the computer. Remove the computer cover and continue with
the following steps.
SBT2 Server Board Product Guide 55
Page 56
12. Remove the jumper from pins 9-10.
13. Replace the computer cover. Leave the upgrade disk in drive A and turn on the computer.
14. Continue with the BIOS upgrade (see page 55).
Changing the BIOS Language
You can use the BIOS upgrade utility to change the language the BIOS uses for messages and the
Setup program. Use a bootable floppy disk containing the Intel flash utility and language files.
1. Boot the computer with the bootable floppy disk in drive A. The BIOS upgrade utility screen
appears.
2. Select
3. Select
4. Select drive A and use the arrow keys to select the correct
5. When the utility asks for confirmation that you want to flash the new language into memory,
select
6. When the utility displays the message
<Enter>.
7. The computer will reboot and the changes will take effect.
Update Flash Memory From a File.
Update Language Set. Press <Enter>.
.lng file. Press <Enter>.
Continue with Programming. Press <Enter>.
upgrade is complete, remove the floppy disk. Press
Using the Firmware Update Utility
The Firmware Update Utility is a DOS-based program used to update the Baseboard Management
Controller’s firmware code. You only need to run the Firmware Update Utility if new firmware
code becomes necessary.
Running the Firmware Update Utility
1. Create a DOS bootable diskette. The version of DOS must be 6.0 or higher.
2. Copy the file ANSI.SYS to the diskette. Without this file, the procedure will run correctly, but
the screen will not be readable.
3. Expand the file (for example, SBT2FWSDR.ZIP) to the diskette.
4. Insert the diskette into the drive and boot to it. The utility will run automatically.
5. Shut the system down and remove any floppy disks that may be in the system.
6. Disconnect the AC power cord from the system and wait 60 seconds.
7. Connect the AC power cord and power up the system.
Using the Adaptec SCSI Utility
The Adaptec SCSI utility detects the SCSI host adapters on the server board. The utility runs out of
BIOS and is used to
• Change default values
• Check and/or change SCSI device settings that may conflict with those of other devices in the
server
56Configuration Software and Utilities
Page 57
Running the SCSI Utility
1. When this message appears on the video monitor:
Press Ctrl-A to run SCSI Utility...
2. Press <Ctrl+A> to run this utility. When it appears, choose the host adapter that you want to
configure.
Another Adaptec utility that is available on the SBT2 Resource CD is the Adaptec EZ SCSI utility.
It is designed to be installed from diskettes on to a DOS or Windows operating system.
SBT2 Server Board Product Guide 57
Page 58
58Configuration Software and Utilities
Page 59
4Solving Problems
This chapter helps you identify and solve problems that might occur while you are using the
system.
Resetting the System
To do this:Press:
Soft boot reset, which clears system memory and reloads the
operating system.
Clear system memo ry, restart POST, and reload the operating
system.
Cold boot reset. Turn the system power off and then on. This
clears system memory, restarts POST, reloads the operating
system, and halts power to all peripherals.
Initial System Startup
Problems that occur at initial system startup are usually caused by incorrect installation or
configuration. Hardware failure is a less frequent cause.
<Ctrl+Alt+Del>
Reset button
Power off/on
Checklist
q Are the power supplies turned on? Check the switches on the back of the chassis.
q Are all cables correctly connected and secured?
q Are the processors or processor termination board fully seated in their slots on the server
board?
q Are all add-in PCI boards fully seated in their slots on the server board?
q Are all jumper settings on the server board correct?
q Are all jumper and switch settings on add-in boards and peripheral devices correct? To check
these settings, refer to the manufacturer’s documentation that comes with them. If applicable,
ensure that there are no conflicts—for example, two add-in boards sharing the same interrupt.
q Are all DIMMs installed correctly?
q Are all peripheral devices installed correctly?
q If the system has a hard disk drive, is it properly formatted or configured?
q Are all device drivers properly installed?
q Are the configuration settings made in Setup correct?
q Is the operating system properly loaded? Refer to the operating system documentation.
q Did you press the system power on/off switch on the front panel to turn the server on (power on
light should be lit)?
q Is the syst em power cord proper ly connected to the sys tem and plugged int o a
NEMA 5-15R outlet for 100-120 V∼ or a NEMA 6-15R outlet for 200-240 V∼?
59
Page 60
q Is AC power available at the wall outlet?
q Are all integrated components from the tested components lists? Check the tested memory, and
chassis lists, as well as the supported hardware and operating system list on the Intel Customer
Support website.
Running New Application Software
Problems that occur when you run new application software are usually related to the software.
Faulty equipment is much less likely, especially if other software runs correctly.
Checklist
q Does the system meet the minimum hardware requirements for the software? See the software
documentation.
q Is the software an authorized copy? If not, get one; unauthorized copies often do not work.
q If you are running the software from a diskette, is it a good copy?
q If you are running the software from a CD-ROM disk, is the disk scratched or dirty?
q If you are running the software from a hard disk drive, is the software correctly installed? Were
all necessary procedures followed and files installed?
q Are the correct device drivers installed?
q Is the software correctly configured for the system?
q Are you using the software correctly?
If the problems persist, contact the software vendor’s customer service representative.
After the System Has Been Running Correctly
Problems that occur after the system hardware and software have been running correctly often
indicate equipment failure. Many situations that are easy to correct, however, can also cause such
problems.
Checklist
q If you are running the software from a diskette, try a new copy of the software.
q If you are running the software from a CD-ROM disk, try a different disk to see if the problem
occurs on all disks.
q If you are running the software from a hard disk drive, try running it from a diskette. If the
software runs correctly, there may be a problem with the copy on the hard disk drive. Reinstall
the software on the hard disk, and try running it again. Make sure all necessary files are
installed.
q If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard
input is incorrect), a marginal power supply, or other random component failures.
q If you suspect that a transient voltage spike, power outage, or brownout might have occurred,
reload the software and try running it again. (Symptoms of voltage spikes include a flickering
video display, unexpected system reboots, and the system not responding to user commands.)
60Solving Problems
Page 61
NOTE
✏
Random errors in data files: If you are getting random errors in your data
files, they may be getting corrupted by voltage spikes on your power line. If
you are experiencing any of the above symptoms that might indicate voltage
spikes on the power line, you may want to install a surge suppressor between
the power outlet and the system power cord.
More Problem Solving Procedures
This section provides a more detailed approach to identifying a problem and locating its source.
Preparing the System for Diagnostic Testing
CAUTION
Turn off devices before disconnecting cables: Before disconne ct ing any
peripheral cables from the system, turn off the system and any external
peripheral devices. Failure to do so can cause permanent damage to the
system and/or the peripheral devices.
1. Turn off the system and all external peripheral devices. Disconnect all of them from the
system, except the keyboard and video monitor.
2. Make sure the system power cord is plugged into a properly grounded AC outlet.
3. Make sure your video display monitor and keyboard are correctly connected to the system.
Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their
maximum ranges (see the documentation supplied with your video display monitor).
4. If the operating system normally loads from the hard disk drive, make sure there is no diskette
in drive A. Otherwise, place a diskette containing the operating system files in drive A.
5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on
page 62.
Monitoring POST
See Chapter 3.
Verifying Proper Operation of Key System Lights
As POST determines the system configuration, it tests for the presence of each mass storage device
installed in the system. As each device is checked, its activity light should turn on briefly. Check
for the following:
q Does the diskette drive activity light turn on briefly? If not, see “Diskette Drive Activity Light
Does Not Light” on page 64.
q If a second diskette drive is installed, does its activity light turn on briefly? If not, see “Diskette
Drive Activity Light Does Not Light” on page 64.
q The hard disk and network activity lights are not connected to the SBT2 server board. They
will not light up.
SBT2 Server Board Product Guide 61
Page 62
Confirming Loading of the Operating System
Once the system boots up, the operating system prompt appears on the screen. The prompt varies
according to the operating system. If the operating system prompt does not appear, see “Ini tia l
System Startup” on page 59.
Specific Problems and Corrective Actions
This section provides possible solut ions for these spec ifi c prob le ms :
• Power light does not light.
• There is no beep or an incorrect beep pattern.
• No characters appear on screen.
• Characters on the screen appear distorted or incorrect.
• System cooling fans do not rotate.
• Diskette drive activity light does not light.
• CD-ROM drive activity light does not light.
• There are problems with application software.
• The bootable CD-ROM is not detected.
Try the solutions in the order given. If you cannot correct the problem, contact your service
representative or authorized dealer for help.
Power Light Does Not Light
Check the following:
q Is the system operating normally? If so, the power LED is probably defective or the cable from
the front panel to the server board is loose.
q Are there other problems with the system? If so, check the items listed under “System Cooling
Fans Do Not Rotate Properly.”
If all items are correct and problems persist, contact your service representative or authorized dealer
for help.
No Characters Appear on Screen
Check the following:
q Is the keyboard functioning? Check to see that the “Num Lock” light is functioning.
q Is the video monitor plugged in and turned on?
q Are the brightness and contrast controls on the video monitor properly adjusted?
q Are the video monitor switch settings correct?
q Is the video monitor signal cable properly installed?
q Is the onboard video controller enabled?
62Solving Problems
Page 63
If you are using an add-in video controller board, do the following:
1. Verify that the video controller board is fully seated in the server board connector.
2. Reboot the system for changes to take effect.
3. If there are still no characters on the screen after you reboot the system and POST emits a beep
code, write down the beep code you hear. This information is useful for your service
representative.
4. If you do not receive a beep code and characters do not appear, the video display monitor or
video controller may have failed. Contact your service representative or authorized dealer
for help.
Characters Are Distorted or Incorrect
Check the following:
q Are the brightness and contrast controls properly adjusted on the video monitor? See the
manufacturer’s documentation.
q Are the video monitor signal and power cables properly installed?
If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact
your service representative or authorized dealer for help.
System Cooling Fans Do Not Rotate Properly
If the system cooling fans are not operating properly, system components could be damaged.
Check the following:
q Is AC power available at the wall outlet?
q Is the system power cord properly connected to the system and the wall outlet?
q Did you press the power button?
q Is the power on light lit?
q Have any of the fan motors stopped (use the server management subsystem to check the fan
status)?
q Are the fan power connectors properly connected to the server board?
q Is the cable from the front panel board connected to the server board?
q Are the power supply cables properly connected to the server board?
q Are there any shorted wires caused by pinched cables or power connector plugs forced into
power connector sockets the wrong way?
If the switches and connections are correct and AC power is available at the wall outlet, contact
your service representative or authorized dealer for help.
SBT2 Server Board Product Guide 63
Page 64
Diskette Drive Activity Light Does Not Light
Check the following:
q Are the diskette drive power and signal cables properly installed?
q Are all relevant switches and jumpers on the diskette drive set correctly?
q Is the diskette drive properly configured?
q Is the diskette drive activity light always on? If so, the signal cable may be plugged in
incorrectly.
If you are using the onboard diskette controller, use the SSU to make sure that “Onboard Floppy” is
set to “Enabled.” If you are using an add-in diskette controller, make sure that “Onboard Floppy”
is set to “Disabled.” To run the SSU, see Chapter 3.
If the problem persists, there may be a problem with the diskette drive, server board, or drive signal
cable. Contact your service representative or authorized dealer for help.
Hard Disk Drive Activity Light Does Not Light
The hard disk drive activity light is not connected to the SBT2 server board.
CD-ROM Drive Activity Light Does Not Light
Check the following:
q Are the power and signal cables to the CD-ROM drive properly installed?
q Are all relevant switches and jumpers on the drive set correctly?
q Is the drive properly configured?
q Is the onboard IDE controller enabled?
Cannot Connect to a Server
q Make sure you are using the drivers that are shipped on the system Configuration Software CD
for the onboard network controller.
q Make sure the driver is loaded and the protocols are bound.
q Make sure the network cable is securely attached to the connector at the system back panel. If
the cable is attached but the problem persists, try a different cable.
q Make sure the hub port is configured for the same duplex mode as the network controller.
q Check with your LAN administrator about the correct networking software that needs to be
installed.
q If you are directly connecting two servers (no hub), you will need a crossover cable (see your
hub documentation for more information on crossover cables).
q Check the network controller LEDs that are visible through an opening at the system back
panel.
64Solving Problems
Page 65
Problems with Network
The server hangs when the drivers are loaded.
q Change the PCI BIOS interrupt settings. Try the “PCI Installation Tips” below.
Diagnostics pass, but the connection fails.
q Make sure the network cable is securely attached.
q Make sure you specify the correct frame type in your NET.CFG file.
The Activity LED doesn’t light.
The network activity light is not connected to the SBT2 server board.
The controller stopped working when an add-in adapter was installed.
q Make sure the cable is connected to the port from the onboard network controller.
q Make sure your PCI BIOS is current. Try the “PCI Installation Tips” below.
q Make sure the other adapter supports shared interrupts. Also, make sure your operating system
supports shared interrupts; OS/2
†
does not.
q Try reseating the add in adapter.
The add-in adapter stopped working without apparent cause.
q Try reseating the adapter first; then try a different slot if necessary.
q The network driver files may be corrupt or deleted. Delete and then reinstall the drivers.
q Run the diagnostics.
PCI Installation Tips
Some common PCI tips are listed here.
q Reserve interrupts (IRQs) and/or memory addresses specifically for ISA adapters. This
prevents PCI cards from trying to use the same settings ISA cards are using. Use the SSU to
keep track of ISA adapter resources.
q Certain drivers may require interrupts that are not shared with other PCI drivers. The SSU can
be used to adjust the interrupt numbers for PCI devices. For certain drivers, it may be
necessary to alter settings so that interrupts are not shared.
SBT2 Server Board Product Guide 65
Page 66
Problems with Application Software
If you have problems with application software, do the following:
q Verify that the software is properly configured for the system. See the software installation and
operation documentation for instructions on setting up and using the software.
q Try a different copy of the software to see if the problem is with the copy you are using.
q Make sure all cables are installed correctly.
q Verify that the server board jumpers are set correctly. See Chapter 5.
q If other software runs correctly on the system, contact your vendor about the failing software.
If the problem persists, contact the software vendor’s customer service representative for help.
Bootable CD-ROM Is Not Detected
Check the following:
qIs the BIOS set to allow the CD-ROM to be the first bootable device?
66Solving Problems
Page 67
5Technical Reference
Server Board Jumpers
7C10
87
65
43
1
2
3N7
1211
109
87
65
43
1
2
OM10428
Figure 14. Jumper Locations
Table 5.CPU Clock Speed (7C10) Jumper
CPU SpeedPin 1-2Pins 3-4Pins 5-6Pins 7-8
866
933
1000
áá
áá
á
Table 6.Configuration Jumper (3N7)
Jumper NamePinsWhat it does at system reset
Configuration
Jumper
BIOS Recovery9-10For normal operation, these pins should not be jumpered.
Reserved7-8Reserved. These pins should not be jumpered.
Reserved5-6Reserved. These pins should not be jumpered.
Password
Disable
CMOS clear1-2If these pins are jumpered, the CMOS settings will be cleared on the next
11-12Normal operation. These pins should always be jumpered.
3-4If these pins are jumpered, the password will be cleared on the next reset.
These pins should not be jumpered for normal operation.
reset. These pins should not be jumpered for normal operation.
67
Page 68
General Procedur e to Change Jumper Setting
The short general procedure for changing a configuration setting is the same for most of the jumper
functions, so we will describe it here.
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Turn off all connected peripherals, turn off system power, and disconnect the AC power cord.
3. Remove the side cover. You do not need to remove the server board from the chassis, and you
probably do not need to remove any add-in boards.
4. Put a jumper on the pins specified for the desired setting.
5. Reinstall the side cover, connect the power cord, and turn on the system for the change to take
effect.
6. You will need to remove the jumper back to its original setting to restore proper functionality.
CMOS Jumper
The jumper at pins 1-2 controls whether settings stored in CMOS nonvolatile memory (NVRAM)
are retained during a system reset.
Procedure to restore the system’s CMOS and RTC to default values:
1. See “General Procedure to Change Jumper Setting” on page 68.
2. Install a jumper on pins 1 and 2 (the Clear CMOS memory position).
3. Reinstall the side cover for your saf ety, and connect the power cord to the sys te m.
4. Turn the system on. Wait for POST to complete and for the messages
jumper”
and “Press F2 to enter Setup” to appear. This automatically reprograms CMOS
and RTC to their default settings.
5. Enter Setup and make any changes necessary (for example, changing the boot device). Press
<F10> to save the new Setup configuration and exit Setup.
6. Turn off the system, and disconne ct the power cord from the sys te m.
7. Remove the side cover.
8. Remove the jumper from pins 1-2.
9. Reinstall the side cover, and connect the power cord to the system.
10. Run BIOS Setup or the SSU to verify the correct settings. See Chapter 3.
“NVRAM cleared by
68Technical Reference
Page 69
Password Jumper
The jumper at pins 3-4 control whether the user and supervisor passwords are retained or cleared
during a system reset.
Procedure to clear the current password and then enter a new one:
1. See “General Procedure to Change Jumper Setting” on page 68.
2. Install a jumper on pins 3-4.
3. Reinstall the side cover for your saf ety, and connect the power cord to the syst e m.
4. Turn the system on, and wait for POST to complete. This automatically clears the password.
5. Turn off the system, and disconnect the power cord.
6. Remove the side cover.
7. Remove the jumper from pins 3 and 4.
8. Reinstall the side cover, and connect the power cord to the system.
9. Run Setup to specify a new password. See Chapter 3.
SBT2 Server Board Product Guide 69
Page 70
70Technical Reference
Page 71
6Regulatory and Integration Information
Product Regulatory Compliance
The SBT2 complies with the following safety regulations, and has been verified to comply with the
following electromagnetic compatibility (EMC) regulations when installed in a compatible host
Intel product.
Product Safety Complia nce
• UL 1950 - CSA 950 (US/Canada)
• EN 60 950 (European Union)
• IEC60 950 (International)
• CE – Low Voltage Directive (73/23/EEC) (European Union)
• EMKO-TSE (74-SEC) 207/94 (Nordics)
Product EMC Compliance
NOTE
✏
To ensure EMC product regulation compliance, the end system must be used
with a shielded LAN cable.
• EN61000-3-2 & -3 (Power Harmonics & Fluctuation and Flicker)
• CE – EMC Directive (89/336/EEC) (European Union)
• VCCI (Class A) – Radiated & Conducted Emissions (Japan)
• AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand)
• RRL (Class A) (Korea)
• BSMI (Class A) (Taiwan)
Product Regulatory Compliance Markings
This product is provided with the following Product Certification Markings.
• UL / cUL Listing Mark
• CE Mark
• German GS Mark
• Russian GOST Mark
• FCC, Class A Verification Marking
71
Page 72
• ICES-003 (Canada EMC Compliance Marking)
• VCCI, Class A Mark
• Australian C-Tick Mark
• Taiwan BSMI Class A Certification Marking
Electromagnetic Compatibility Notices
USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, inc luding inte rf eren ce tha t may cause unde si red opera tion.
For questions related to the EMC performance of this product, contact:
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124
1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit other than the one to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the
user’s authority to operate the equipment.
the modified product.
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC
Class B limits may be attached to this computer product. Operation with noncompliant peripherals
is likely to result in interference to radio and TV reception.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables,
connected to peripherals, that are not shielded and grounded may result in interference to radio and
TV reception.
72Regulatory and Integration Information
The customer is responsible for ensuring compliance of
Page 73
FCC Verification Statement
Product Type: 133-659719; SBT2
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
For questions related to the EMC performance of this product, contact:
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124-6497
Phone: 1 (800)-INTEL4U or 1 (800) 628-8686
ICES-003 (Canada )
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils
Numériques”, NMB-003 édictée par le Ministre Canadian des Communications.
(English translation of the notice above) This digital apparatus does not exceed the Class A limits
for radio noise emissions from digital apparatus set out in the interference-causing equipment
standard entitled “Digital Apparatus,” ICES-003 of the Canadian Department of Communications.
Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to
illustrate its complian ce.
This is a Class A product based on the standard of the Voluntary Control Council For Interference
(VCCI) from Information Technology Equipment. If this is used near a radio or television receiver
in a domestic environment, it may cause radio interference. Install and use the equipment
according to the instruction manual .
SBT2 Server Board Product Guide 73
Page 74
BSMI (Taiwan)
The BSMI Certification number and the following warning is located on the product safety label
which is located on the bottom side (pedestal orientation) or side (rack mount configuration).
Replacing the Back up Battery
The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the
absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer
service representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with
the same or equivalent type recommended by the equipment
manufacturer. Discard used batteries according to manufacturer’s
instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri
som anbefalt av apparatfabrikanten. Brukt batteri returneres
apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller
en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera
använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty
paristo valmistajan ohjeiden mukaisesti.
74Regulatory and Integration Information
Page 75
7Equipment Log and Power Consumption
Worksheets
Equipment Log
Use the blank equipment log provided here to record information about your system. You will
need some of this information when you run the SSU.
Manufacturer Name and
Item
System
Server board
Primary Processor speed
and cache
Secondary Processor speed
and cache
Video display
Model NumberSerial NumberDate Installed
Keyboard
Mouse
Diskette drive A
Diskette drive B
Tape drive
CD-ROM drive
Hard disk drive 1
Hard disk drive 2
Hard disk drive 3
Hard disk drive 4
Hard disk drive 5
continued
75
Page 76
Equipment Log (continued)
Item
Manufacturer Name and
Model NumberSerial NumberDate Installed
76Equipment Log and Power Consumption Worksheets
Page 77
Current Usage
NOTE
✏
Both processors pull power from +5V. This may limit the number of drives
and/or add-in cards you may install.
As an overall current usage limitation on the power supply, do not exceed a combined power output
of 195 watts for the +5 and +3.3 volt outputs.
The PCI slots on the server board are rated at a maximum of 5 amperes per slot. The maximum
power allowed for each slot is 20 watts at +5 volts. The average current usage per slot should not
exceed 3.0 amperes per slot; that is, 15 watts.
The cooling efficiency varies per slot; the re fore, en sure th at adequ ate coo ling is avail able in the
target slot—especially in an expansion slot drawing more than 2.0 amperes.
Calculating Power Consumption
The total combined wattage for the system configuration must be less than the output of your power
supply. Use the two worksheets in this section to calculate the power used by your server boards.
For current and voltage requirements of add-in boards and peripherals, see your vendor documents.
SBT2 Server Board Product Guide 77
Page 78
Worksheet, Calculating DC Power Usage
1. List the current for each board and device in the appropriate voltage level column.
2. Add the currents in each column. Then go to the next worksheet.
Table 7.Power Usage Worksheet 1
Current (maximum) at voltage level:
Device+3.3 V+5 V5 V Standby+12 V–12 V
Server board4.24 A6.46 A.5 A
Primary Processor
Secondary Processor (if present)
Terminator card, if no second
processor
Memory (four 64 MB DIMMs)1.22 A
PCI slot 11.0 A
PCI slot 21.0 A
PCI slot 31.0 A
PCI slot 41.0 A
PCI slot 51.0 A
PCI slot 61.0 A
Pci slot 71.0 A
1st 3.5-inch hard disk drive
2nd 3.5-inch hard disk drive
3rd 3.5-inch hard disk drive
4th 3.5-inch hard disk drive
5th 3.5-inch hard disk drive
6th 3.5-inch hard disk drive
7th 3.5-inch hard disk drive
3.5-inch diskette drive
CD-ROM drive
Cooling fan 1.43 A
Cooling fan 2.43 A
Cooling fan 3.43 A
Cooling fan 4.43 A
Total Current
78Equipment Log and Power Consumption Worksheets
Page 79
Worksheet, Total Combined Power Used by the System
1. From the previous worksheet, enter the total current for each column.
2. Multiply the voltage by the total current to get the total wattage for each voltage level.
3. Add the total wattage for each voltage level to arrive at a total combined power usage on the
power supply.
Table 8.Power Usage Worksheet 2
Voltage level and total current
(V X A = W)
(+3.3 V) X (______ A)________ W
(+5 V) X (______ A)________ W
(–5 V) X (______ A)________ W
(+12 V) X (______ A)________ W
(–12 V) X (______ A)________ W
Total Combined Wattage________ W
Total Watts
for each voltage level
SBT2 Server Board Product Guide 79
Page 80
80Equipment Log and Power Consumption Worksheets
Page 81
Index
A
Adapter Fault Tolerance, 13, 14
Adaptive Load Balancing, 13, 14
Add-in boards, IDE bus slots, 11
administrative password, 16
limiting access to SCU, 18
Advanced Menu, configuring in Setup, 37
AFT. See Adapter Fault Tolerance
agency certification, 73
ALB. See Adaptive Load Balancing
audible beep error codes, 34
B
Back Panel Connectors, 8
battery
disposing of sa fely, 31, 74
installing, 31
removing, 31, 74
beep codes, 34
BIOS
changing the language, 56
recovering, 55
upgrading, 5 3
language, cha nging in BIOS, 56
lithium backup battery
disposing of sa fely, 31, 74
installing, 31
removing, 31, 74
M
Memory, 10
amount tested, POST, 34
capacity, 7
DIMM requirements, 10
video amou nt, 7
what type to install, 7
mouse
compatibility, 15
inactivity timer, 15
network, controller, 7, 13
Network Teaming, 13
P
password, 16
administrative, 16
administrator, 16
entering to unblank screen, 18
retaining at system reset, 69
user, 16
using to reactivate keyboard/mouse, 18
using to reactivate keyboard/mouse, 15
bootable media required, 34
memory, amount tested, 34
power supply
calculating power usage, 77
current usage, 77
worksheet, calculating DC power, 78
problems
after runnin g new application software, 60
after system has be en running correctly,
60
application software, 66
bootable CD-ROM not detected, 66
cannot connect to network server, 64
CD-ROM drive activity light, 64
confirm OS loa ding, 62
diskette drive light, 64
hard drive light, 64
initial system startup, 59
network, 65
no characters on screen, 62
PCI installation tips, 65
power light, 62
preparing syste m for diagnostic testing, 61
random error in data files, 61
screen characters incorrect, 63
system cooling fans do not rotate, 63
system lights, 61
82Index
Page 83
processor, 21
features, 10
removing, 22
selecting the correct processor, 21
R
real time clock, r unning SCU to configure
settings, 31
reset system, 33, 59
S
SCSI, bus termination requirements, 12
SCSI controller, 12
SCU
administrative password limits access
to, 18
changing co nfiguration, 33
inactivity (lockout) timer, 15
software locking feature, 16
secure mode, 17
affects boot sequence, 18
enter by setting passwords, 17
no booting from diskette without
password, 17
using hot keys to enter, 33
security, 16, 17
alarm switches, 16
boot sequence, 18
enabling/disabling floppy writes, 17
locking mouse, keyboard with tim er,
15, 18
password, 18
secure mode, 17
secure mode, setting in SCU, 17
software lock, SCU, 16
unattended start, 18
using hot key combination, 33
video blanking, 18
Security menu, configuring, Setup, 41
server board
CMOS settings, jumper, 68
component locations, figure, 9
configuratio n jum per s, 68
configuratio ns, 67
password jumper, 69
server management, intrusion detection, 16
Server menu, configuring in Setup, 42
Setup
Advanced menu, 37
Boot Device Pri ority menu, 43
Boot menu, 42
cannot enter, need to reconfigure
diskette, 35
changing co nfiguration, 33
Console Redirec tion menu, 42
description, 35
Exit menu, 43
Main menu, 36
PCI Configura tion menu, 41
recording settings, 35
security menu contents, 41
server menu contents, 42
soft boot, 59
SSU. See system setup utility
switches
alarm, 16
DC power, 59
reset, 59
System Configuration Utility. See SCU