Intel RMS25KB080, RMS25KB040 Quick Start User Manual

Intel® Integrated RAID Module RMS25KB080 and RMS25KB040 Quick Start User's Guide
This guide contains step-by-step instructions for installing the Intel® Integrated RAID Module RMS25KB080 and RMS25KB040
and information on using the BIOS setup utility to configure a single logical
drive array and install the driver into the operating system.
What you will need to begin
SAS 2.0 or SATA III hard disk drives (backward compatible to support SAS 1.0 or SATA II hard
disk drives)
®
Intel
Integrated RAID Module RMS25KB080 or RMS25KB040 (SAS/SATA cables need to be
prepared separately)
SAS/SATA cable accessory kit, which can be ordered from Intel separately. Please see the Tested
Operating System List for available cable accessory kits at:
http://www.intel.com/p/en_US/support/server
Server board with a x8 or x16 PCI Express* slot (this controller is designed to meet the x8 PCI
Express* Generation 3 specification and is backward compatible with generation 2 or 1 slots)
Resource CD, which is shipped with systems or boards
Operating system installation media: Microsoft Windows Server 2003*, Microsoft Windows
Server 2008*, Microsoft Windows Server 2012*, Microsoft Windows 7*, Microsoft Windows Vista*, Red Hat* Enterprise Linux, or SUSE* Linux Enterprise Server, VMware* ESX Server 4, and VMware* ESXi5. Notes: The module will support PCI Express* Revision 3.0 at post launch.
2
Install the RAID Module
Power down the system and disconnect the
A
power cord.
Remove the system cover and any
B
other pieces to access the PCI Express* slot.
Firmly press the RAID module into an available
C
x8 or x16 PCI Express* Slot. Secure the RAID module bracket to the system
D
back panel.
E
The Intel® Integrated RAID Module RMS25KB080 is shown for illustrative purpose.
For more advanced RAID configurations, or to install with other
operating systems, please refer to the Hardware User’s Guide.
These guides and other supporting documents (including a list of supported server boards) are also located on the web at:
http://www.intel.com
If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, see your Hardware Guide for complete ESD
®
procedures. For more details on Intel
RAID controllers, see:
www.intel.com/go/serverbuilder.
Read all cautions and warnings first before starting your RAID Controller
integration.
Intel® Integrated RAID Module RMS25KB080 as shown
*
1
Check the Bracket Height
Determine whether the full-height bracket will fit
A
in the server’s PCI back plate.
Full-height
Bracket
Low-profile
Bracket
Your RAID controller ships with the full-height
B
bracket. If the low-profile bracket is required, unscrew the two fasteners holding the green board to the silver bracket.
Remove the bracket.
C
Line up the low-profile bracket with the board,
D
making sure the two holes align.
Replace and tighten
E
the two screws.
PCI Express* Slot (3.3 V)
Building Value with Intel
Server Products, Programs and Support
Get the high-value server solutions you need by taking advantage of the outstanding value Intel provides to system integrators:
High-quality server building blocks
Extensive breadth of server building blocks
Solutions and tools to enable e-Business
Worldwide 24x7 technical support
(AT&T Country Code + 866-655-6565)
World-class service, including a
three-year limited warranty and Advanced Warranty Replacement
For more information on Intel's added-value server offerings, visit the Intel website at: www.intel.com/go/serverbuilder.
1
®
1
ServerBuilder
Intel shop for information about all of Intel's Server Building Blocks such as:
Product information, including
product briefs and technical product specifications
Sales tools, such as videos and
presentations
Training information, such as the
Intel
Support Information and much more
®
ServerBuilder is your one-stop
®
Online Learning Center
1
Available only to Intel® Channel Program
Members, part of Intel
®
e-Business Network.
Warning
Read all caution and safety
statements in this document before performing any of the instructions. Also see the Intel®
Server Board and Server Chassis Safety Information document at:
http://support.intel.com/support/ motherboards/server/sb/cs-010770 .htm for complete safety information.
Warning
Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.
Caution
Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components.
Tools Required
Intel® Integrated RAID Module RMS25KB080 and RMS25KB040 Reference Diagram
Front View
Bracket Screw(2)
x8 PCI Express* Interface
J4B1 Ports 4-7
(This connector is
not available on
®
Integrated
Intel
RAID Module
RMS25KB040)
J4A1 Ports 0-3
Back View
3
Connect the RAID Module
Connect the wide end of the cable to the up silver connector (ports
A
0-3).The Intel illustrative purpose.
Push the cable into the silver connector until it makes a slight click.
B
If using more than four drives, connect the wide end of the second
C
cable to the down silver connector (ports 4-7). Connect the other ends of the cables to SATA drives or to the ports
D
on a SATA or SAS backplane.
Notes: Both non-expander backplanes (one cable per drive) and expander backplanes (one or two total cables) are supported. Drive power cables (not shown) are required.
®
Integrated RAID Module RMS25KB080 is shown for
Ports 4-7 (This connector is not available on
®
Integrated RAID Module RMS25KB040 )
Intel
A
C
D
4
Use the LSI MPT SAS BIOS Configuration Utility* to Create a RAID Virtual Drive
Note: As necessary, see “Choosing the Right RAID Level” on side 2 of this Quick Start User's Guide for a brief description of RAID levels.
Highlight RAID Properties and press <Enter>.
Power on the system and press <Ctrl> + <C> when the screen
1
below is displayed.
B
In the Adapter List Global Properties window select the controller in
2
the Adapter column and press <Enter>.
3
4
On the Select New Array Type screen, select the appropriate configuration, for example Create IM Volume, and press <Enter>.
Phillips* screwdriver
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2014, Intel Corporation. All rights reserved.
G42745-004
Anti-static wrist strap
For more information on the jumpers referenced in this diagram, refer to user guide located on the web at:
http://support.intel.com/support/motherboards/server.
D
Rear view of four SATA drives or backplane connected to ports
on the Intel
®
Integrated RAID Module RMS25KB080.
4
(Cont.) Use the LSI MPT SAS BIOS Configuration Utility* to Create a RAID Virtual Drive
Side 2
In the RAID Disk column highlight No and press <Space>.
5
After the RAID array is created, the following screen will appear. Press <Esc> to
9
return to the main menu.
In the RAID Disk column highlight No and press <Space>.
6
Choose Exit the Configuration Utility and Reboot and press <Enter> to
10
reboot the system.
When the RAID Disk status is listed as shown below, press <C> to create an array.
7
During system reboot, verify that Logical Volume is displayed in the Product
11
column.
Select Save changes then exit this menu, then press <Enter>.
8
5
Install the Operating System Drivers
Note: Below section lists the general driver loading process for frequently used operating systems. For more details, and for other supported operating systems, refer to the corresponding driver release notes to get latest information.
Microsoft
Windows 2003*
Create installation media (floppy disk required for Microsoft Windows 2003*; removable
1
media, such as a floppy disk, USB device, or CD/DVD-ROM, required for Microsoft Windows 2008*). See the instructions at the right.
Boot the server and start the OS installation.
2
Press the <F6> key as soon as the first
3
screen appears.
4
When prompted to specify a mass storage controller:
a. Press <S> to specify additional storage devices.
b. Insert the installation driver disk that you created in step 1 above.
c. Press the <Enter> key to select the “Installation Driver” and continue with the Windows installation.
Follow the on-screen instructions to complete the Windows installation.
5
OR
Windows 2008*/2012*
When you see: “Where do you want to install windows?”, select Load Driver, and then click Next.
When prompted by the Load Driver dialog:
a. Insert the removable installation media that you created in step 1 above.
b. Press the <Enter> key to select the “Installation Driver” and continue with the Windows installation.
Microsoft
Red Hat*
OR
1
2
3
4
5
Enterprise Linux
Create installation media (removable media, such as a floppy disk, USB device, or CD/DVD-ROM, required). See the instructions at the right.
Boot the system with Red Hat* Enterprise Linux CD-ROM.
At the boot prompt, insert the Linux installation disk that you created in step 1.
Type Linux dd, and press the <Enter> key.
Follow the on-screen instructions to complete the installation. The RAID controller driver is automatically detected and installed.
OR
SuSE* Linux
Enterprise Server
Boot the system with SuSE* Linux Enterprise Server (SLES) CD-ROM.
When the first screen displays, insert the Linux installation disk that you created step 1.
Press the <F5> key for SLES 10 or the <F6> key for SLES 11 to load the driver, and then select an installation menu option.
Create Installation Media
Obtain the drivers either from the resource CD or the Intel web site.
1
If using the Resource CD, insert the resource CD. Browse to \Drivers and then the matching OS folder.
2
OR
Go to http://downloadcenter.intel.com and locate your product under Server Products in the left menu.
Microsoft Windows* Linux*
Extract the files from the zip file to your
3
hard drive. Copy the appropriate files to a floppy disk (for Microsoft Windows 2003*) or removable media (for Microsoft
Windows 2008*).
Copy the matching .sys, .cat, .oem, and .inf driver files to a floppy disk or removable media.
Extract the driver update disk (DUD) image (file extension .img) from the zip file to your hard drive. If you have a system with Microsoft Windows*, you will need a third-party utlity such as ‘rawrite’ to extract the DUD image to a floppy disk. For a system under Linux or Sun Solaris*, use the ‘dd’ command as follows:
dd if=<image_file_name> of=<path-to-media>
‘path-to-media’ is usually /dev/fd0, but may differ if you are using a USB floppy drive.
Choosing the Right RAID Level
D1
RAID 0 (IS)
Disk 1
D2
Disk 2
Creation of a RAID volume is now complete.
Minimum Disks: 2
Read performance: Excellent Write performance: Excellent Fault tolerance: None
Striping of data across multiple drives in an array. This provides high performance, but no data protection.
To manage a RAID array, install Intel® RAID Web Console 2
Install the Intel® RAID Web Console 2 package from the Resource CD.
Extract the contents of the ZIP file and run Setup.exe from the Disk1 folder.
Choose one of four installation modes: Complete (installs all features), Client (administrative machine only), Server (can be managed remotely), or StandAlone (only manages itself).
To start Intel® RAID Web Console 2 from within the OS: Choose Start | Programs | RAID WebConsole | RAID WebConsole 2. For additional details, see the Intel® RAID Software User’s Guide.
Install the Intel® RAID Web Console 2 package from the Resource CD.
Unpack Linux_rwc2_**tar.gz. Remove any line breaks and allow permissions by typing $> tr -d ‘\15\32’ < existing_file_name > new_file_name $> chmod a+x new_file_name Run ./install.sh
RAID 1 (IM)
RAID 1E (IME)
D1 D2
Disk 1
D1 D3 D4 D6
Disk 1
D1 D2
Disk 2
D2 D1
D5 D4
Disk 2
D3 D2 D6 D5
Disk 3
Number of Disks: 2
Read performance: Excellent Write performance: Good Fault tolerance: Excellent
Minimum Disks: 3
Read performance: Excellent Write performance: Good Fault tolerance: Excellent
Disk mirroring, meaning that all data on one disk is duplicated on another disk. This is a high availability solution, but only half the total disk space is usable.
Enhanced disk mirroring, meaning that all data on one disk is duplicated on other disks. This is a high availability solution, but only half the total disk space is usable.
Loading...