Intel S2600WT2, S2600WTT, R1000WT, R2000WT, S2600WT Configuration Manual

Intel® Server Board S2600WT Family Intel® Server Chassis R1000WT & R2000WT Family Intel® Server System R1000WT & R2000WT Family
Product Family Configuration Guide
Revision 2.01
May 2015
Intel® Server Boards and Systems
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
ii
Document Revision History
Date Published
Revision
Revision Change Description
September 2014
1.0
First Public Release
November 2014
1.16
Updates to product illustrations and MM# for Intel®RAID Modules
March 2015 1.17
Content updates:
DC Power Supply option target availability date
New Rail kit options target availability date
Removed I/O Module AXX10GBTWLIOM – Not supported
Added I/O Module AXX10GBTWLIOM3 with target availability date
April 2015 2.0
Document Upgrade
New document format
New product definition/data tables
New graphics
Improved guidance for configuration requirements
Improved descriptions for product family definition
Updated SAS/SATA data cable guide
Updated Disclaimer Statements
May 2015
2.01
Document changes:
Added “Server” reference to product family naming
Corrected 1U riser part number in 1U L6 BOM Lists
Updated Server Board, Chassis only and L6 product weight information
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iii
Disclaimer
Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Learn more at Intel.com, or from the OEM or retailer.
You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein.
No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document.
The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.
Intel disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non­infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade.
Intel, the Intel logo, Xeon, and Xeon Phi are trademarks of Intel Corporation in the U.S. and/or other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2015 Intel Corporation. All Rights Reserved.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iv
Table of Contents
1. INTEL SERVER FAMILY OVERVIEW ........................................................................................................................................................................................................................... 1
1.1 INTEL® S2600WT PRODUCT FAMILY NAMING CONVENTION .................................................................................................................................................................................................................... 3
1.2 PRODUCT FAMILY SUMMARY CHART ............................................................................................................................................................................................................................................................... 6
1.3 INTEL® S2600GZ/GL PRODUCT FAMILY TO INTEL® S2600WT PRODUCT FAMILY TRANSITION GUIDE .......................................................................................................................................... 8
2. SERVER BUILDING BLOCK CONFIGURATION ......................................................................................................................................................................................................... 9
2.1 BUILDING BLOCK RECIPE SUMMARY ............................................................................................................................................................................................................................................................. 10
2.2 INTEL® SERVER BOARD S2600WT PRODUCT FAMILY SKUS ................................................................................................................................................................................................................. 11
iPC – S2600WT2 ................................................................................................................................................................................................................................................................................................... 11
iPC – S2600WTT ................................................................................................................................................................................................................................................................................................... 11
2.3 INTEL® SERVER CHASSIS R1000WT PRODUCT FAMILY SKUS (1U RACK MOUNT CHASSIS) ..................................................................................................................................................... 12
R1304WTXXX ......................................................................................................................................................................................................................................................................................................... 13
R1208WTXXX ......................................................................................................................................................................................................................................................................................................... 14
2.4 INTEL® SERVER CHASSIS R2000WT PRODUCT FAMILY SKUS (2U RACK MOUNT CHASSIS) ..................................................................................................................................................... 15
R2312WTXXX ......................................................................................................................................................................................................................................................................................................... 16
R2000WTXXX ......................................................................................................................................................................................................................................................................................................... 17
3. SERVER SYSTEM CONFIGURATION ....................................................................................................................................................................................................................... 18
3.1 INTEL® SERVER SYSTEM R1000WT PRODUCT FAMILY SKUS (1U RACK MOUNT SYSTEM) ........................................................................................................................................................ 19
R1304WTTGS.......................................................................................................................................................................................................................................................................................................... 20
R1304WT2GS.......................................................................................................................................................................................................................................................................................................... 21
R1208WTTGS.......................................................................................................................................................................................................................................................................................................... 22
R1208WT2GS.......................................................................................................................................................................................................................................................................................................... 23
3.2 INTEL® SERVER SYSTEM R2000WT PRODUCT FAMILY SKUS (2U RACK MOUNT SYSTEM) ........................................................................................................................................................ 24
R2208WT2YS .......................................................................................................................................................................................................................................................................................................... 25
R2208WTTYS .......................................................................................................................................................................................................................................................................................................... 26
R2208WTTYC1 ....................................................................................................................................................................................................................................................................................................... 27
R2308WTTYS .......................................................................................................................................................................................................................................................................................................... 28
R2312WTTYS .......................................................................................................................................................................................................................................................................................................... 29
R2224WTTYS .......................................................................................................................................................................................................................................................................................................... 30
4. SAS / SATA DATA CABLE GUIDE ............................................................................................................................................................................................................................. 31
4.1 SAS / SATA DATA CABLE CONNECTOR TYPES ......................................................................................................................................................................................................................................... 31
4.2 1U / 2U SERVER SYSTEM SAS / SATA CABLE GUIDE ............................................................................................................................................................................................................................. 32
4.2.1 1U 4 x 3.5” – R1304WTxxx SAS / SATA Data Cable Guide .............................................................................................................................................................................................. 34
4.2.2 1U 8 x 2.5” – R1208WTxxx SAS / SATA Data Cable Guide .............................................................................................................................................................................................. 35
4.2.3 2U 8 x 3.5” – R2308WTxxx Cable Guide ................................................................................................................................................................................................................................. 36
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
v
4.2.4 2U 12 x 3.5 – R2312WTxxx Cable Guide ................................................................................................................................................................................................................................. 37
4.2.5 2U 2.5” Front Mount Drive Bay Cable Guide ........................................................................................................................................................................................................................ 41
4.3 INTEL SAS / SATA DATA CABLE KITS ......................................................................................................................................................................................................................................................... 48
5. INTEL 1U / 2U SYSTEM CONFIGURATION OPTIONS .......................................................................................................................................................................................... 52
5.1 1U 8X2.5” COMBO PCIE* SFF (NVME) SSD / SAS BACKPLANE INTEL® ACCESSORY KIT A1U44X25NVMEDK................................................................................................................ 52
5.1.1 1U 8x2.5” – Intel® Accessory Kit A1U44X25NVMEDK Cable Guide ............................................................................................................................................................................. 53
5.2 2U 8X2.5” COMBO PCIE* SFF (NVME) SSD / SAS BACKPLANE INTEL® ACCESSORY KIT A2U44X25NVMEDK ................................................................................................................ 55
5.2.1 2U 8x2.5” – Intel® Accessory Kit A2U44X25NVMEDK SAS/SATA Cable Guide ....................................................................................................................................................... 57
5.2.2 2U 16x2.5” / 24x2.5” –– Intel® Accessory Kit A2U44X25NVMEDK SAS / SATA Cable Guide ........................................................................................................................... 58
5.3 2U REAR MOUNT HOT SWAP DRIVE BAY ACCESSORY KIT IPC A2UREARHSDK .......................................................................................................................................................................... 59
iPC - A2UCBLSSD .................................................................................................................................................................................................................................................................................................. 59
5.4 2U 8X3.5” FRONT MOUNT HOT SWAP BACKPLANE ASSEMBLY - IPC A2U8X35S3HSDK .......................................................................................................................................................... 60
iPC – A2U8X35S3HSDK ...................................................................................................................................................................................................................................................................................... 60
5.5 2U 8X2.5” DRIVE BAY MODULE OPTIONS ................................................................................................................................................................................................................................................. 61
iPC – A2U8X25S3HSDK ..................................................................................................................................................................................................................................................................................... 62
iPC – A2U8X25S3DPDK ...................................................................................................................................................................................................................................................................................... 62
iPC – A2UHANDLKIT ............................................................................................................................................................................................................................................................................................. 63
5.6 LOCKING FRONT BEZEL ACCESSORY KITS ................................................................................................................................................................................................................................................... 64
5.6.1 2U Front Bezel Accessory Kit – iPC A2UBEZEL ..................................................................................................................................................................................................................... 64
5.6.2 1U Front Bezel Accessory Kit – iPC A1UBEZEL ..................................................................................................................................................................................................................... 65
5.7 1U / 2U PCIE* RISER CARD ACCESSORY/SPARE FRU OPTIONS ........................................................................................................................................................................................................... 66
5.7.1 1U Riser Card Options ..................................................................................................................................................................................................................................................................... 66
5.7.2 2U Riser Card Options ..................................................................................................................................................................................................................................................................... 67
5.8 INTEL® I/O EXPANSION MODULES ................................................................................................................................................................................................................................................................ 69
Intel Product Code ................................................................................................................................................................................................................................................................................................ 70
iPC – AXX1P40FRTIOM ....................................................................................................................................................................................................................................................................................... 70
iPC – AXX2P40FRTIOM ....................................................................................................................................................................................................................................................................................... 70
iPC – AXX10GBNIAIOM........................................................................................................................................................................................................................................................................................ 70
iPC – AXX10GBTWLIOM3 ................................................................................................................................................................................................................................................................................... 71
iPC – AXX1FDRIBIOM ........................................................................................................................................................................................................................................................................................... 71
iPC – AXX2FDRIBIOM ........................................................................................................................................................................................................................................................................................... 71
iPC – AXX4P1GBPWLIOM ................................................................................................................................................................................................................................................................................... 72
5.9 INTEL® SAS RAID ADD-IN CARDS, MODULES, AND ACCESSORIES ......................................................................................................................................................................................................... 73
5.9.1 Intel® Integrated RAID Module RMS3 Product Family – SAS 3.0 (12 Gb/s) .............................................................................................................................................................. 73
5.9.2 Intel® RAID Controller Add-in Cards - SAS 3.0 (12Gb/s) ................................................................................................................................................................................................... 75
5.9.3 Intel® RAID Accessory Options ..................................................................................................................................................................................................................................................... 78
5.10 INTEL POWER SUPPLY MODULES AND POWER CORDS ............................................................................................................................................................................................................................. 81
5.11 1U / 2U RACK MOUNT KITS .......................................................................................................................................................................................................................................................................... 82
iPC - AXXPRAIL ....................................................................................................................................................................................................................................................................................................... 82
iPC – AXXELVRAIL.................................................................................................................................................................................................................................................................................................. 82
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
vi
iPC – AXX1U2UCMA ............................................................................................................................................................................................................................................................................................. 82
iPC - AXX2POSTBRCKT ....................................................................................................................................................................................................................................................................................... 83
5.12 INTEL® XEON PHI COPROCESSOR CARD AND NON-INTEL GPGPU SUPPORT .................................................................................................................................................................................... 84
iPC – AWTCOPRODUCT ...................................................................................................................................................................................................................................................................................... 85
iPC – A2UL16RISER2 ............................................................................................................................................................................................................................................................................................ 86
6. 1U / 2U MISCELLANEOUS ACCESSORY OPTIONS .............................................................................................................................................................................................. 87
iPC – A1U2ULCP .................................................................................................................................................................................................................................................................................................... 87
iPC – AXXSATADVDROM .................................................................................................................................................................................................................................................................................... 87
iPC – AXXSATADVDRWROM ............................................................................................................................................................................................................................................................................. 87
iPC - AXXSSDODDKIT .......................................................................................................................................................................................................................................................................................... 88
iPC - AXXRJ45DB93 ............................................................................................................................................................................................................................................................................................. 88
iPC - AXXRMM4LITE ............................................................................................................................................................................................................................................................................................. 89
iPC - AXXTPME5 ..................................................................................................................................................................................................................................................................................................... 89
7. 1U / 2U SPARE AND REPLACEMENT PARTS (FRUS) ........................................................................................................................................................................................... 90
8. EXTENDED WARRANTY ............................................................................................................................................................................................................................................ 94
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
vii
List of Tables
Table 1. Product Family Reference Collaterals ...................................................................................................................... 2
Table 2. Server Board Product Family Summary .................................................................................................................. 6
Table 3. Server Chassis & Server System Product Family Summary ............................................................................ 6
Table 4. 1U / 2U Server System Product Family Generation to Generation Transition Guide ......................... 8
Table 5. 1U / 2U Building Block to Integrated System Recipe Guide ........................................................................ 10
Table 6. 2U 12 x 3.5” – R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander) ............................. 39
Table 7. 2U 8 x 2.5" (Drive Bay #1) - SAS/SATA Data Cable Guid (with no SAS Expander) ............................. 42
Table 8. 2U 8 x 2.5” (Drive Bay #2) – SAS / SATA Data Cable Guide (with no SAS Expander) ....................... 43
Table 9. 2U 8 x 2.5” (Drive Bay #3) – SAS / SATA Data Cable Guide (with no SAS Expander) ....................... 44
Table 10. 2U 2.5” Front Mount Drive Configurations with SAS Expander – SAS Data Cable Guide ........... 46
Table 11. Storage Data Cable Kit Description and Order Information ..................................................................... 49
Table 12. 1U 8x2.5" Combo Backplane SAS/SATA Cable Guide ................................................................................. 54
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
1
1. Intel Server Family Overview
This document is provided to assist Intel customers with identifying the right Intel server system and available accessories to create a unique server platform that meet their unique server requirements.
The Intel® S2600WT product family is offered as both building block options and integrated systems. The product family consists of the following:
Server Building Blocks:
Intel® Server Board S2600WT – Server Board only (Building block option and spare FRU)
Intel® Server Chassis R1000WT product family – 1U Rack Mount Server Chassis only
Intel® Server Chassis R2000WT product family – 2U Rack Mount Server Chassis only
Integrated Server Systems:
Intel® Server System R1000WT product family – 1U Rack Mount Server System integrated with an Intel® Server Board S2600WT
Intel® Server System R2000WT product family – 2U Rack Mount Server System integrated with an Intel® Server Board S2600WT
The Intel® S2600WT product family supports the following processors and memory:
Intel® Xeon® processor E5-2600 v3 product family
o Note: Previous generation Intel® Xeon® processors are not supported.
DDR4 ECC RDIMM 1600, 1866, 2133
DDR4 ECC LRDIMM 1600, 1866, 2133
Intel® Server S2600WT Product Family
Intel® Server Board S2600WT
Intel® Server Chassis R1000WT
Product Family
Intel® Server Chassis R2000WT
Product Family
Intel® Server System R1000WT
Product Family
Intel® Server System R2000WT
Product Family
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
2
Additional Information and Software
For additional information about this family of products or any of their supported accessories, refer to the following resources available at
http://www.intel.com/support.
Table 1. Product Family Reference Collaterals
For this information or software Use this Document or Software
For in-depth technical information about this product family
Intel® Server Board S2600WT Technical Product Specification
Intel
®
Server System R1000WT Product Family Technical Product Specification
Intel
®
Server System R2000WT Product Family Technical Product Specification
Intel® Remote Management Module 4 (Intel® RMM4) and Integrated BMC User Guide
Intel® Remote Management Module 4 Technical Product Specification
Intel® I/O Expansion Modules Hardware Specification
Intel® Server System BIOS Setup Utility Guide
Intel® Server Platform Firmware Specification Update
Product Safety and Regulatory Compliance - Intel® Xeon® Processor E5-2600 v3
http://www.intel.com/p/en_US/support/highlights/server/s2600wt?wapkw=s2600wt+family
For system integration instructions and service guidance
Intel® Server System R1000WT product family System Integration and Service Guide
Intel® Server System R2000WT product family System Integration and Service Guide
http://www.intel.com/p/en_US/support/highlights/server/s2600wt?wapkw=s2600wt+family
For server configuration guidance and compatibility
Intel
®
Server Configurator tool
http://serverconfigurator.intel.com
For system power budget guidance
Intel® Server Board S2600WT Product Family Power Budget Tool and Thermal Configuration Guide
https://downloadcenter.intel.com/product/78562/Intel-Server-Board-S2600WT-Family
For system firmware updates, onboard device drivers, and
software to manage your Intel® Server System.
https://downloadcenter.intel.com/product/78562/Intel-Server-Board-S2600WT-Family
For a complete list of supported processors, memory, add-
in cards, and peripherals:
http://www.intel.com/p/en_US/support/category/server/s2600wt/doc_guide#
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
3
1.1 Intel® Server S2600WT Product Family Naming Convention
Chassis Type
R = RACK MOUNT
Server Board Identifier
WT = Intel® Server Board S2600WT product family supported WT2 = Intel® Server Board S2600WT w/1 GbE LOM – iPC S2600WT2 WTT = Intel® Server Board S2600WT w/10 GbE LOM – iPC S2600WTT
U Height
1 = 1U 2 = 2U
Power Supply Type Included
X = None Included G = 750W
Y = 1100W
Drive Form Factor
(Specific to front drive bays)
0 = No drives supported 2 = 2.5”
3 = 3.5”
# of Power Supplies Included
X = None S = 1 (Non-redundant) C = 2 (Redundant)
# of Drives Supported
(Specific to front drive bays)
00 12 04 16 08 24
Note: 00 product codes have no front mount drive bays. Hot swap drive support can be added with the addition of available
drive bay accessory options.
Special System SKU
# = a sequential number starting with 1 within the product family, identifying a special system SKU that adds a non-standard feature from other offered system SKUs. This last digit may or may not be present on all offered system SKUs.
WTT
2
08 Y C 2 R
Intel® Server Chassis
Chassis
Type
U Height
Drive Form
Factor
# of
Drives
Server
Board
Identifier
Power
Supply
Type
# of Power
Supplies
Included
Intel® Server System
1
Special
System SKU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
4
Figure 1. Intel® Server System R1000WT Feature Set Identification
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5
Figure 2. Intel® Server System R2000WT Feature Set Identification
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
6
1.2 Product Family Summary Chart
The Intel® S2600WT product family is built around either of two Intel® Server Board S2600WT options: S2600WTT and S2600WT2. The feature set of each server board option is identical except for the onboard LAN controller.
The S2600WTT SKU offers a LAN on Motherboard (LOM) option supporting dual RJ45 10Gb Base-T LAN ports. The S2600WT2 SKU offers a LAN on Motherboard (LOM) option supporting dual RJ45 1Gb Base-T LAN ports.
The following tables provides an overview of available Intel product codes for building blocks and systems within the Intel® S2600WT product family. Each line item identifies key features supported in the shipping Intel SKU. Additional order code information and full product descriptions for each option are provided in later sections.
Table 2. Server Board Product Family Summary
Intel Product Code
# of CPU
sockets
# of DIMM
Slots
# of Riser
Slots
Onboard RJ45
LAN ports
# of SATA ports
(6 Gb)
SATA SW
RAID
Support
Intel® I/O
Module Support
Intel® SAS RAID Module
support
Server Board only
S2600WT2
2
24 3 2 (1 Gb)
10
Yes
Yes
Yes
S2600WTT
2
24 3 2 (10 Gb)
10
Yes
Yes
Yes
Table 3. Server Chassis & Server System Product Family Summary
Intel Product Code
Chassis
Form
Factor
Drive
Form
Factor
# of Drives
(front)
1
# of
Drives
(rear)
# of PCIe*
Add-in Card
Slots
3rd Riser
Power Supply
Modules
Rails
SAS
RAID
SAS Expander
Chassis Only (KDK)
R1304WTXXX 1U 3.5” 4 na opt na opt opt opt na
R1208WTXXX
1U
2.5” 8 na
opt
na
opt
opt
opt
na
R2312WTXXX
2U
3.5”
12
opt
opt
opt
opt
opt
opt
opt
R2000WTXXX 2
2U
opt
opt
opt
opt
opt
opt
opt
opt
opt
2x 10G LOM System (L6 BIK)
R1304WTTGS
1U
3.5” 4 na 2 na
1x 750W AC
opt
opt
na
R1208WTTGS
1U 2.5” 8 na 2 na 1x 750W AC opt opt na
R2208WTTYS 2U 2.5” 8 opt 8 yes 1x 1100W AC opt opt na
R2308WTTYS 2U 3.5” 8 opt 8 yes 1x 1100W AC opt opt na
R2312WTTYS 2U 3.5” 12 2 6 opt 1x 1100W AC opt opt opt
R2224WTTYS
2U
2.5”
24 2 6
opt
1x 1100W AC
opt
opt
opt
R2208WTTYC1 3
2U
2.5” 8 opt 6 yes
2x 1100W AC
opt
opt
na
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
7
Intel Product Code
Chassis
Form
Factor
Drive
Form
Factor
# of Drives
(front)
1
# of
Drives
(rear)
# of PCIe*
Add-in Card
Slots
3rd Riser
Power Supply
Modules
Rails
SAS
RAID
SAS Expander
2x 1G LOM System (L6 BIK)
R1304WT2GS 1U 3.5” 4 na 2 na 1x 750W AC opt opt na
R1208WT2GS
1U
2.5” 8 na 2 na
1x 750W AC
opt
opt
na
R2208WT2YS
2U
2.5” 8 opt 8 yes
1x 1100W AC
opt
opt
na
Table Notes:
1 – All front drive bays are 12Gb SAS capable 2 – R2000WTXXX Chassis can support all 8x2.5” drive bay accessory options or 8x3.5” drive bay accessory option 3 – System SKU with included system features to support Intel® Xeon Phi™ Coprocesser cards with passive (no fan) heat sink solutions. High power add­in cards with active cooling solutions are NOT supported in this SKU.
Terms used in the table:
na – Not Applicable opt – Accessory option sold separately yes – Option included KDK – Knock Down Kit – Intel PCSD term for chassis only product BIK – Server Board in KDK – Intel PCSD term for integrated (L6) system product L6 – Integrated system with no processors, memory, or storage devices
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
8
1.3 Intel® S2600GZ/GL Product Family to Intel® Server S2600WT Product Family Transition Guide
If transitioning from the previous generation Intel® S2600GZ/GL product family, the following table can be used to identify an equivalent system within the Intel® S2600WT product family.
Table 4. 1U / 2U Server System Product Family Generation to Generation Transition Guide
Prior
Generation
Product Code
New Generation
1G LOM SKU
Product Code
New Generation
10G LOM SKU Product Code
Required accessories to match configuration Advantages included in current generation
R1208GL4DS R1208WT2GS R1208WTTGS AXXELVRAIL AXXRMM4LITE
750 vs460 PSU, 24 vs16DIMM
R1208GZ4GC
R1208WT2GS
R1208WTTGS
AXXELVRAIL
AXXRMM4LITE
FXX750PCRPS
R1208GZ4GS9 R1208WT2GS R1208WTTGS
R1304GL4DS9
R1304WT2GS
R1304WTTGS
750 vs460 PSU, 24vs16DIMM
R1304GZ4GC R1304WT2GS R1304WTTGS AXXELVRAIL AXXRMM4LITE FXX750PCRPS
R1304GZ4GS9
R1304WT2GS
R1304WTTGS
R2208GL4DS9 R2208WT2YS R2208WTTYS
Rear drives option, 1100W vs 460W PSU, 3rd riser, 24vs16 dimms
R2208GL4GS R2208WT2YS R2208WTTYS AXXELVRAIL AXXRMM4LITE
Rear drives option, 1100W vs 750W PSU, 3rd riser, 24vs16
dimms
R2208GZ4GC R2208WT2YS R2208WTTYS AXXELVRAIL AXXRMM4LITE AXX1100PCRPS Rear drives option, 1100W vs 750W PSU, 3rd riser
R2208GZ4GS9 R2208WT2YS R2208WTTYS
Rear drives option, 1100W vs 750W PSU, 3rd riser
R2224GZ4GC4
R2224WTTYS AXXELVRAIL AXXRMM4LITE
Rear drives included, 1100W vs 750W PSU, 3rd riser optional
R2308GL4GS
R2308WTTYS AXXELVRAIL AXXRMM4LITE
Rear drives option, 1100W vs 750W PSU, 3rd riser, 24vs16 dimms
R2308GZ4GC
R2308WTTYS AXXELVRAIL AXXRMM4LITE AXX1100PCRPS Rear drives option, 1100W vs 750W PSU, 3rd riser
R2308GZ4GS9
R2308WTTYS
Rear drives option, 1100W vs 750W PSU, 3rd riser
R2312GL4GS
R2312WTTYS AXXELVRAIL AXXRMM4LITE
Rear drives included, 1100W vs 750W PSU, 3rd riser optional,
24vs16 dimms
R2312GZ4GC4
R2312WTTYS AXXELVRAIL AXXRMM4LITE AXX1100PCRPS Rear drives included, 1100W vs 750W PSU, 3rd riser optional
R2312GZ4GS9
R2312WTTYS
Rear drives included, 1100W vs 750W PSU, 3rd riser optional
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
9
2. Server Building Block Configuration
Server building blocks are offered to give Intel customers the option to configure and assemble a unique server system from the bare chassis up. Each building block component and optional accessory is purchased seperately. At a minimum, building up a functional server system using building blocks will require the following:
1U or 2U Intel Server Chassis – Intel® Server Chassis R1000WT or R2000WT
Intel® Server Board S2600WT– S2600WT2 or S2600WTT
SAS / SATA Data cables
Power Supply module(s)
Power cord(s)
Rack mount kit – Rails or fixed mount
Processor
Memory
Storage Drives
Optional Intel accessories that can be added include the following: See chapter 5 for available options.
Riser cards options
SAS / SAS RAID support – PCIe* add-in card or module + Appropriate SAS Data cable(s)
Intel® I/O Module
Intel® Remote Management Module 4 Lite
1U – Intel® Server Chassis R1000WT 2U – Intel® Server Chassis R2000WT
Intel® Server Board S2600WT
750W or 1100W Power Supply Module
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
10
2.1 Building Block Recipe Summary
The following table is used to identify the building block options required to assemble an equivalent server system SKU offered within the Intel® Server System R1000WT or R2000WT product families.
The first column in the table identifies the available integrated system SKUs. The columns to the right of a specified system SKU identify the Intel building block kits required to assemble the equivalent system.
Table 5. 1U / 2U Building Block to Integrated System Recipe Guide
Intel L6 System
Product Code
Building blocks needed to assemble an equivalent system
Intel Chassis
Product Code
Server
Board
Front Drive Bay
assembly
Power Supply
Modules
Riser Slot 1 and 2
Riser Cards
Riser Slot 3
Riser Card
Rear Drive Bay
Assembly
SAS cables for 12Gb
R1304WTTGS R1304WTXXX S2600WTT included (1x) FXX750PCRPS (2x) F1UL16RISER2 NA NA
800mm cable
AXXCBL1UHRHD
R1304WT2GS R1304WTXXX S2600WT2 included (1x) FXX750PCRPS (2x) F1UL16RISER2 NA NA
800mm cable
AXXCBL1UHRHD
R1208WTTGS R1208WTXXX S2600WTT included (1x) FXX750PCRPS (2x) F1UL16RISER2 NA NA AXXCBL1UHRHD
R1208WT2GS R1208WTXXX S2600WT2 included (1x) FXX750PCRPS (2x) F1UL16RISER2 NA NA AXXCBL1UHRHD
R2208WTTYS R2000WTXXX S2600WTT A2U8X25S3HSDK (1x) AXX1100PCRPS (2x) A2UL8RISER2 A2UX8X4RISER optional AXXCBL730HDHD
R2208WTTYC1
R2000WTXXX +
AWTCOPRODUCT
S2600WTT A2U8X25S3HSDK (2x) AXX1100PCRPS (2x) A2UL16RISER2 A2UX8X4RISER optional AXXCBL730HDHD
R2208WT2YS R2000WTXXX S2600WT2 A2U8X25S3HSDK (1x) AXX1100PCRPS (2x) A2UL8RISER2 A2UX8X4RISER optional AXXCBL730HDHD
R2224WTTYS
R2000WTXXX +
A2UHANDLKIT
S2600WTT
(3x)
A2U8X25S3HSDK
(1x) AXX1100PCRPS (2x) A2UL8RISER2 optional A2UREARHSDK
AXXCBL730HDHD +
(2) AXXCBL875HDHD
R2308WTTYS R2000WTXXX S2600WTT A2U8X35S3HSDK (1x) AXX1100PCRPS (2x) A2UL8RISER2 A2UX8X4RISER optional
1/2 kit of:
AXXCBL800HDHD &
AXXCBL950HDHD
R2312WTTYS R2312WTXXX S2600WTT included (1x) AXX1100PCRPS (2x) A2UL8RISER2 optional A2UREARHSDK
AXXCBL800HDHD
AXXCBL875HDHD
AXXCBL950HDHD
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
11
2.2 Intel® Server Board S2600WT Product Family SKUs
Intel Product Code
(iPC)
Order Information
Product Description Product Type
iPC – S2600WT2
MM# - 934880
UPC - 00735858288859
EAN - 5032037068130
MOQ - 1
Packaged Gross Weight
3.1 Kgs, 6.8 Lbs
Un-packaged Net Weight
1.7 Kgs, 3.8 Lbs
Intel® Server Board S2600WT2
Support for dual Intel
®
Xeon E5-2600 v3 processor family
Maximum supported TDP for board 145W (not available in all chassis configurations)
Intel
®
C612 chipset
24 DDR4 DIMM Slots
8 AHCI SATA 6Gb ports thru two 4-port SFF-8643 connectors
2 AHCI SATA 6Gb ports for ODD, DOM, SSD thru two 7-pin SATA connectors
2 Integrated 1Gb ports (Intel
®
Ethernet Controller I350)
Integrated Baseboard Management controller with IPMI 2.0 support
Optional advanced management features activated by AXXRMM4LITE key
Dedicated 1Gb management port onboard
Support for up to 3 riser cards with multiple Intel riser card options
o NOTE – 2 CPUs required for riser #2 and riser #3 support
Support for Intel
®
I/O expansion module option
Support for Intel
®
SAS module option
Box includes: one server board Note: All necessary mounting hardware, cabling, and shielding will ship with the Intel chassis
and optional accessory kits.
Server Board only
Building block
option
Spare FRU
iPC – S2600WTT
MM# - 934882
UPC - 00735858288842
EAN - 5032037068123
MOQ - 1
Packaged Gross Weight
3.1 Kgs, 6.8 Lbs
Un-packaged Net Weight
1.7 Kgs, 3.8 Lbs
Intel® Server Board S2600WTT
Support for dual Intel
®
Xeon E5-2600 v3 processor family
Maximum supported TDP for board 145W (not available in all chassis configurations)
Intel
®
C612 chipset
24 DDR4 DIMM Slots
8 AHCI SATA 6Gb ports thru two 4-port SFF-8643 connectors
2 AHCI SATA 6Gb ports for ODD, DOM, SSD thru two 7-pin SATA connectors
2 Integrated 10Gb ports (Intel
®
Ethernet Controller X-540)
Integrated Baseboard Management controller with IPMI 2.0 support
Optional advanced management features activated by AXXRMM4LITE key
Dedicated 1Gb management port
Support for up to 3 riser cards with multiple Intel riser card options
o NOTE – 2 CPUs required for riser #2 and riser #3 support
Support for Intel
®
I/O expansion module option
Support for Intel
®
SAS module option
Box includes: one server board Note: All necessary mounting hardware, cabling, and shielding will ship with the Intel chassis
and optional accessory kits.
Server Board Only
Building block
option
Spare FRU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
12
2.3 Intel® Server Chassis R1000WT Product Family SKUs – (1U Rack Mount Chassis)
The product tables found in this section provide order code information and detailed descriptions for each available 1U Intel server chassis building block option. The lower sections of each table identify:
The ship along components of the specified chassis product code – (product BOM)
Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set
Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis. Additional
accessories can be found in Chapter 5
NOTES:
Each required item and optional accessory is sold seperately from the specified Intel server building block
Items identifed as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by description
and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or accessory.
Figure 3. Intel® Server Chassis R1000WT – 1U Chassis only Building Block (KDK)
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
13
Intel Product Code (iPC):
R1304WTXXX
1U – 4 x 3.5” HDD or 4 x 2.5” SSD front mount drives
Order Code Information:
MM# - 936121
UPC - 00735858287944
EAN - 5032037067492 MOQ - 1
Product Type: Chassis Only Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 19 Kgs, 41.9 Lbs Un-packaged Net Weight: 10.3 Kgs, 22.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements
Intel product code R1304WTXXX includes the following components:
(1) – 1U Chassis with Quick Reference Label affixed to top cover (1) – Air duct (6) – Dual rotor system fans – iPC FR1UFAN10PW (1) – Pre-installed Standard Control Panel assembly (board only –
iPC FXXFPANEL)
(1) – Pre-installed Front I/O Panel assembly (1 x VGA and 2 x USB)
(w/internal attach cables)
(1) – SATA Optical drive bay with filler panel
Includes optical drive mounting latch kit – iPN H19168-00x
Includes optical drive power cable – iPN G95880-00x
(4) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
includes (1) 12 Gb SAS backplane – iPC FR1304S3HSBP
includes (4) 3.5” hot swap drive carriers – iPC
FXX35HSCAR (1) – Server board to backplane power cable – iPN H38458-00x (1) – Server board to backplane I2C cable – iPN H39941-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (2) – Riser card mounting brackets – (riser cards sold separately. See chapter 5.7.1) (1) – Power Supply Bay blank insert (8) – DIMM slot blanks – iPN H43597-00x (2) – Chassis handles (1 set) installed – iPN H19171-00x (2) – AC Power Cord retention strap assembly – iPN H23961-00x Server board and riser card mounting screws Spares for each screw type included
Required Items – Sold Separately:
Intel® Server Board S2600WT (choose one)
o iPC S2600WT2 – with 1G LOM o iPC S2600WTTwith 10G LOM
Power supply module(s) – (Choose one type)
two common modules required for redundancy
o iPC FXX750PCRPS – 750 W AC Power
Supply Module
o iPC AXX750DCCRPS – 750 W DC Power
Supply Module
(Available Late Q2 2015)
Power Cord(s) – See chapter 5.10
Rack Mount Kit – See chapter 5.11
1 or 2 Intel® Xeon® Processor E5-2600 v3
product family
ECC DDR4 memory (RDIMM or LRDIMM)
Optional Intel Accessories – Sold Separately:
iPC F1UL16RISER2 – One x16 PCIe* 3.0 slot
Riser Card – (1 for each riser slot)
Intel® I/O Module – See chapter 5.8 for options
Intel® SAS RAID Card / Module – See section
5.9 for options
SAS/SATA Data cables – Cable selection is
dependant on desired storage option. See Chapter 4.2.1 for available cable options
iPC A1UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE – Intel® Remote
Management Module Lite key. For advanced management features
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
14
Intel Product Code (iPC):
R1208WTXXX
1U – 8 x 2.5” front mount drives
Order Code Information:
MM# - 936187
UPC - 00735858287951
EAN - 5032037067508
MOQ - 1
Product Type: Chassis Only Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 19 Kgs, 41.9 Lbs Un-packaged Net Weight: 10.3 Kgs, 22.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements
Intel product code R1208WTXXX includes the following
components:
(1) – 1U Chassis with Quick Reference Label affixed to top cover (1) – Air duct (6) – Dual rotor system fans – iPC FR1UFAN10PW (1) – Pre-installed Standard control panel assembly (board only iPC
FXXFPANEL)
(1) – Pre-installed Front I/O Panel assembly (1 x VGA and 2 x USB)
(w/internal attach cables)
If removed, can be used as an optical drive bay.
Includes optical drive mounting latch kit – iPN H19168-00x
Includes optical drive power cable – iPN H23851-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC F1U8X25S3HSBP
Includes (8) 2.5” hot swap drive carriers – iPC
FXX25HSCAR2 (1) – Server board to backplane power cable – iPN H38457-00x (1) – Server board to backplane I2C cable – iPN H39941-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (2) – Riser card mounting brackets – (riser cards sold separately. See chapter 5.7.1) (1) – Power Supply Bay blank insert (8) – DIMM slot blanks – iPN H43597-00x (2) – Chassis handles (1 set) installed – iPN H19171-00x (2) – AC Power Cord retention strap assembly – iPN H23961-00x Server board and riser card mounting screws Spares for each screw type included
Required Items – Sold Separately:
Intel® Server Board S2600WT (choose one)
o iPC S2600WT2 – with 1G LOM o iPC S2600WTTwith 10G LOM
Power supply module(s) – (Choose one type)
two common modules required for redundancy
o iPC FXX750PCRPS – 750 W AC Power
Supply Module
o iPC AXX750DCCRPS – 750 W DC Power
Supply Module
(Available Late Q2 2015)
Power Cord(s) – See chapter 5.10
Rack Mount Kit – See chapter 5.11
1 or 2 Intel® Xeon® Processor E5-2600 v3
product family
ECC DDR4 memory (RDIMM or LRDIMM)
Optional Intel Accessories – Sold Separately:
iPC F1UL16RISER2 – One x16 PCIe* 3.0 slot
Riser Card – (1 for each riser slot)
Intel® I/O Module – See chapter 5.8 for options
Intel® SAS RAID Card / Module – See section
5.9 for options
SAS/SATA Data cables – Cable selection is
dependant on desired storage option. See Chapter 4.2.2 for available cable options
iPC A1UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE – Intel® Remote
Management Module Lite key. For advanced management features
iPC A1U44X25NVMEDK – (4) PCIe* SSD SFF
(NVMe*) + (4) SAS support – replaces exising backplane and requires use of one PCIe* slot. See system accessories table or System TPS for details
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
15
2.4 Intel® Server Chassis R2000WT Product Family SKUs – (2U Rack Mount Chassis)
The product tables found in this section provide order code information and detailed descriptions for each available 2U Intel server chassis building block option. The lower sections of each table identify:
The ship along components of the specified chassis product code – (product BOM)
Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set
Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis. Additional
accessories can be found in Chapter 5
NOTES:
Each required item and optional accessory is sold seperately from the specified Intel server building block
Items identifed as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by description
and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or accessory.
Figure 4. Intel® Server Chassis R2000WT – 2U Chassis only Building Block (KDK)
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
16
Intel Product Code (iPC):
R2312WTXXX
2U – 12 x 3.5” HDD or 12 x 2.5” SSD front mount drives
Order Code Information:
MM# - 936022
UPC - 00735858288729
EAN - 5032037068000
MOQ - 1
Product Type: Chassis only Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 21.2 Kgs, 46.7 Lbs Un-packaged Net Weight: 14.4 Kgs, 32.0 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements
Intel product code R2312WTXXX includes the following
components:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (2) – Chassis Handles (1 set) installed, with Integrated control panel
& USB Port - iPC A2UHANDLKIT
(12) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC
F2U12X35S3HSBP – (SAS Data cables sold seperately)
Includes (12) 3.5” hot swap drive carriers – iPC
FXX35HSCAR (1) – Backplane I2C cable – iPN G92510-00x (1) – Backplane power cable – iPN G92685-00x (1) – Internal fixed mount SSD power cable – iPN H23901-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (2) – Riser Card mouting brackets supporting up to 3 riser cards –
(risers cards sold seperately – See chapter 5.7.2) (1) – Power Supply Bay blank insert (16) – DIMM slot blanks - iPN H43597-00x (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x (2) – AC Power Cord retention strap assembly – iPN H23961-00x Server Board and Riser Card mounting screws Spares for each screw type included
Required Items – Sold Separately:
Intel® Server Board S2600WT (choose one)
o iPC S2600WT2 – with 1G LOM o iPC S2600WTTwith 10G LOM
Power supply module(s) – (Choose one
type) two common modules required for redundancy
o iPC AXX1100PCRPS – 1100W AC
Power Supply Module
o iPC FXX750PCRPS – 750 W AC
Power Supply Module
o iPC AXX750DCCRPS – 750 W DC
Power Supply Module
(Available Late
Q2 2015)
Power Cord(s) – See chapter 5.10
Rack Mount Kit – See chapter 5.11
1 or 2 Intel® Xeon® Processor E5-2600 v3
product family
ECC DDR4 memory (RDIMM or LRDIMM)
Optional Intel Accessories – Sold Separately:
Riser Cards – Up to three riser cards can be
installed concurrently – See chapter 5.7
o Risers Slots #1 and #2 – Available riser cards
include:
- iPC A2UL8RISER2 – (3) x8 PCIe* 3.0 slots
- iPC A2UL16RISER2 – (1) x16 PCIe* 3.0 slot + (1) x8 PCIe* 3.0 slot
o Riser Slot #3 – Available riser cards include:
- iPC A2UX8X4RISER – (1) Low profile x8 PCIe*
3.0 slot + (1) LP x8 PCIe* 2.0 slot
Rear Storage Bay Option – See chapter 5.3 o iPC A2UREARHSDK – Up to (2) hot swap SATA
SSDs
Intel® I/O Module – See chapter 5.8 for options
Intel® SAS RAID Card / Module – See section 5.9 for
options
SAS/SATA Data cables – Cable selection is
dependant on desired storage option. See Chapter
4.2.4 for available cable options
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE – Intel® Remote Management
Module Lite key. For advanced management features
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
17
Intel Product Code (iPC):
R2000WTXXX
2U – No front mount drives
Order Code Information:
MM# - 936021
UPC - 00735858287968
EAN - 5032037067515
MOQ - 1
Product Type: Chassis only Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 19 Kgs, 41.9 Lbs Un-packaged Net Weight: 13.3 Kgs, 29.3 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements
Intel product code R2000WTXXX includes the following components:
(1) – 2U Chassis with Quick Reference Label affixed to top
cover (1) – Air duct (6) – Hot swap system fans – iPC
FR2UFAN60HSW
(1) – Pre-installed Standard control panel assembly – (board
only iPC FXXFPANEL (1) – Pre-installed Front I/O Panel assembly (1 x VGA and 2 x
USB) (w/internal attach cables) (1) – SATA Optical drive bay with filler panel and optical
drive mounting latch (1) – I2C cable - server board to backplane – iPN G41809-
00x (backplane sold separately) (1) – Internal fixed mount SSD / optical drive power cable -
iPN H23901-xxx (2) – Riser Card mouting brackets supporting up to 3 riser
cards (riser cards sold seperately – see chapter 5.7.2) (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (1) – Power supply bay blank insert (16) – DIMM slot blanks – iPN H43597-00x (2) – Rack chassis handles (1 set) installed – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x (2) – AC Power Cord retention strap assembly – iPN
H23961-00x Server Board and Riser Card mounting screws Spares for each screw type included
Required Items – Sold Separately:
Intel® Server Board S2600WT (choose
one)
o iPC S2600WT2 – with 1G LOM o iPC S2600WTTwith 10G LOM
Power supply module(s) – (Choose one
type) two common modules required for redundancy
o iPC AXX1100PCRPS – 1100W AC
Power Supply Module
o iPC FXX750PCRPS – 750 W AC
Power Supply Module
o iPC AXX750DCCRPS – 750 W DC
Power Supply Module
(Available
Late Q2 2015)
Power Cord(s) – See chapter 5.10
Rack Mount Kit – See chapter 5.11
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or LRDIMM)
Optional Intel Accessories – Sold Separately
Front storage bay option
o Upto (3) 8 x 2.5” drive bay modules can be installed:
iPC A2U8X25S3HSDK – SAS/SATA iPC A2U8X25S3DPDK – Dual port SAS iPC A2U44X25NVMEDK – PCIe* SSD SFF (NVMe) + SAS (Note) for a 24 x 2.5” drive configuration, system will
lose front video and optical drive support, and system must include the 2U storage front panel in Storage handle kit iPC A2UHANDLKIT
o iPC A2U8X35S3HSDK – 8 x 3.5” drive + Optical drive bay
Re-uses control panel and front I/O panel. Includes
SAS/SATA data cables and peripheral power cable
Rear Storage Bay Option
o iPC A2UREARHSDKUp to (2) hot swap SATA SSDs
Riser Cards – Up to three riser cards can be installed
concurrently
o Risers Slots #1 and #2 – Available riser cards include:
- iPC A2UL8RISER2 – (3) x8 PCIe* 3.0 slots
- iPC A2UL16RISER2 – (1) x16 PCIe* slot + (1) x8 PCIe* slot
o Riser Slot #3 – Available riser cards include:
- iPC A2UX8X4RISER – (1) Low profile x8 PCIe* 3.0 slot + (1) LP x8 PCIe* 2.0 slot
SAS/SATA Data cables – Cable selection is dependant on
desired storage option. See Chapter 4 for available cable options
Intel® SAS RAID Card / Module – See section 5.9 for options
Intel® I/O Module – See chapter 5.8 for options
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE – Intel® Remote Management Module Lite
key. For advanced management features
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
18
3. Server System Configuration
Intel makes available L6 integrated server systems that include a specific server board, power supply module, and hot swap drive bays options. At a minimum, building up a functional L6 server system will require the following:
Rack mount kit option – Rails or fixed mount
Power Cord(s)
Processor(s)
Memory
Storage Drives
Optional Intel accessories that can be added include the following: See chapter 5 for available options.
2
nd
power supply module to add power redundancy
SAS / SAS RAID support – PCIe* add-in card or module + Appropriate SAS Data cable(s)
Intel® I/O Module
Intel® Remote Management Module Lite
Intel®Server System
R1000WT Product Family
*R1208WT configuration shown
Intel® Server System
R2000WT Product Family
*R2312WT configuration shown
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
19
3.1 Intel® Server System R1000WT Product Family SKUs – (1U Rack Mount System)
The product tables found in this section provide order code information and detailed descriptions for the specified L6 integrated 1U Intel server system. The lower sections of each table identify:
The ship along components of the specified chassis product code – (product BOM)
Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set
Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis. Additional
accessories can be found in Chapter 5
NOTES:
Each required item and optional accessory is sold seperately from the specified Intel L6 server system
Items identifed as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by description
and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or accessory.
Figure 5. Intel® Server System R1000WT – L6 Integrated 1U System
*R1208WTxxx shown
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
20
Intel Product Code (iPC):
R1304WTTGS
1U – 4 x 3.5” HDD or 4 x 2.5” SSD front mount drives
Order Code Information:
MM# - 934967
UPC – 00735858288736
EAN – 5032037068017
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 21.3 Kgs, 47.0 Lbs Un-packaged Net Weight: 12.3 Kgs, 27.1 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R1304WTTGS includes the following components:
(1) –1U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (2) – Riser card assembly with single x16 PCIe* slot riser card – iPC
F1UL16RISER2
(1) – 750W power supply module - iPC FXX750PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (4) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC FR1304S3HSBP
Includes (4) 3.5” hot swap drive trays – iPC FXX35HSCAR
(1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL1UHRHD (1) – 350mm Backplane power cable – iPN H38458-00x (1) – 150mm Backplane I2C cable – iPN H39941-00x (1) – Air duct (6) – Dual rotor system fans – iPC FR1UFAN10PW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 550mm optical drive power cable – iPN G95880-00x
(2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H19171-00x Spares for each screw type included
Required Items – Sold
Separately:
Rack Mount Kit – See chapter
5.11 for available options
1 or 2 Intel® Xeon® Processor E5-
2600 v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC FXX750PCRPS – 2nd 750W AC Power supply module
– to support power redundancy
Intel® 12G SAS RAID module + RMFBU - See chapter 5.9
for available options
SAS Data cable – Depending on the location of the SAS
Data controller, a new data cable may be necessary. See chapter 4.2.1
Intel® I/O Module - See chapter 5.8 for available options
iPC A1UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management Module
4 Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID 5
support key
Storage Drives See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
21
Product Code (iPC):
R1304WT2GS
1U – 4 x 3.5” HDD or 4 x 2.5” SSD front mount drives
Order Code Information:
MM# – 935059
UPC – 00735858288743
EAN – 5032037068024
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 21.3 Kgs, 47.0 Lbs Un-packaged Net Weight: 12.3 Kgs, 27.1 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R1304WT2GS includes the following components:
(1) –1U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 1GbE – iPC S2600WT2 (2) – Riser card assembly with single x16 PCIe* slot riser card – iPC
F1UL16RISER2
(1) – 750W power supply module - iPC FXX750PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (4) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC FR1304S3HSBP
Includes (4) 3.5” hot swap drive trays – iPC FXX35HSCAR
(1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL1UHRHD (1) – 350mm Backplane power cable – iPN H38458-00x (1) – 150mm Backplane I2C cable – iPN H39941-00x (1) – Air duct (6) – Dual rotor system fans – iPC FR1UFAN10PW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 550mm optical drive power cable – iPN G95880-00x
(2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle installed (1 set) – iPN H19171-00x Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC FXX750PCRPS – 2nd 750W AC Power supply
module – to support power redundancy
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cable – Depending on the location of the
SAS Data controller, a new data cable may be necessary. See chapter 4.2.1
Intel® I/O Module - See chapter 5.8 for available
options
iPC A1UBEZEL – Lockable front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module 4 Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID
5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
22
Product Code (iPC):
R1208WTTGS
1U – 8 x 2.5” front mount drives
Order Code Information:
MM# – 934968
UPC – 00735858289429
EAN – 5032037068406
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 21.1 Kgs, 46.5 Lbs Un-packaged Net Weight: 12.9 Kgs, 28.4 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R1208WTTGS includes the following components:
(1) –1U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (2) – Riser card assembly with single x16 PCIe* 3.0 slot riser card -
F1UL16RISER2
(1) – 750W power supply module - iPC FXX750PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (1) – Air duct (6) – Dual rotor system fans – iPC FR1UFAN10PW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB)
If removed, can be used as an optical drive bay.
Includes optical drive mounting latch kit – iPN H19168-00x
Includes optical drive power cable – iPN H23851-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC F1U8X25S3HSBP
Includes (8) 2.5” hot swap drive trays – iPC FXX25HSCAR2
(1) – 730mm SAS/SATA Multiport data cable – iPC AXXCBL730HRHD (1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL800HRHD (1) – Backplane power cable – iPN H38458-00x (1) – 200mm Backplane I2C cable – iPN H23846-00x (2) – CPU heatsink – iPC FXXCA84X106HS (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed - iPN H19171-00x Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-
2600 v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC FXX750PCRPS – 2nd 750W AC Power supply
module – to support power redundancy
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.2
Intel® I/O Module - See chapter 5.8 for available
options
iPC A1U44X25NVMEDK – (4) PCIe* SSD SFF (NVMe*)
+ (4) SAS support – replaces exising backplane and requires use of one PCIe* slot. See chapter 5.1 and/or System TPS for details
iPC A1UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID
5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
23
Product Code (iPC):
R1208WT2GS
1U – 8 x 2.5” front mount drives
Order Code Information:
MM# - 935060
UPC – 00735858288897
EAN – 5032037068178
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 1U rack mount Chassis dimensions: L=712mm, W=439mm, H=43.2mm
Packaged Gross Weight: 21.1 Kgs, 46.5 Lbs Un-packaged Net Weight: 12.9 Kgs, 28.4 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260
Product Definition and Configuration Requirements/Options
Intel product code R1208WT2GS includes the following components:
(1) – 1U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 1GbE – iPC S2600WT2 (2) – Riser card assembly with single x16 PCIe* 3.0 slot riser card -
F1UL16RISER2
(1) – 750W power supply module - iPC FXX750PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (1) – Air duct (6) – Dual rotor system fan – iPC FR1UFAN10PW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB)
If removed, can be used as an optical drive bay.
Includes optical drive mounting latch kit – iPN H19168-00x
Includes optical drive power cable – iPN H23851-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC F1U8X25S3HSBP
Includes (8) 2.5” hot swap drive trays – iPC FXX25HSCAR2
(1) – 730mm SAS/SATA Multiport data cable – iPC AXXCBL730HRHD (1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL800HRHD (1) – Server board to backplane power cable – iPN H38458-00x (1) – Server board to backplane I2C cable – iPN H39941-00x (2) – CPU heatsink – iPC FXXCA84X106HS (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H19171-00x Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-
2600 v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC FXX750PCRPS – 2nd 750W AC Power supply
module – to support power redundancy
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.2
Intel® I/O Module - See chapter 5.8 for available
options
iPC A1U44X25NVMEDK – (4) PCIe* SSD SFF (NVMe*)
+ (4) SAS support – replaces exising backplane and requires use of one PCIe* slot. See chapter 5.1 and/or System TPS for details
iPC A1UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID
5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
24
3.2 Intel® Server System R2000WT Product Family SKUs – (2U Rack Mount System)
The product tables found in this section provide order code information and detailed descriptions for the specified L6 integrated 2U Intel server system. The lower sections of each table identify:
The ship along components of the specified chassis product code – (product BOM)
Required Items – The options required to be installed to the base system to achieve basic functionality using the default system feature set
Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis. Additional
accessories can be found in Chapter 5
NOTES:
Each required item and optional accessory is sold seperately from the specified Intel L6 server system
Items identifed as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by description
and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or accessory.
Figure 6. Intel® Server System R2000WT – L6 Integrated 2U System
*R2312WTxxx shown
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
25
Product Code (iPC):
R2208WT2YS
2U – 8 x 2.5” front mount drives
Order Code Information:
MM# – 936032
UPC – 00735858289436
EAN – 5032037068413
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 22.9 Kgs, 50.5 Lbs Un-packaged Net Weight: 16.2 Kgs, 35.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2208WT2YS includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 1GbE – iPC S2600WT2 (1) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 3-slot PCIe* riser cards – iPC A2UL8RISER2 o Includes (1) 2-slot low profile PCIe* riser card – iPC A2UX8X4RISER
(1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 300mm optical drive / internal mount SSD power cable –
iPN H23901-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12Gb SAS backplane – iPC A2U8X25S3HSDK
Includes (8) 2.5” hot swap drive trays – iPC FXX25HSCAR2
(2) – Multiport 730mm SAS/SATA data cables – iPC AXXCBL730HDHD (1) – Backplane 250mm I2C cable – iPN G41809-00x (1) – Backplane power cable – iPN H23927-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x
Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC AXX1100PCRPS – 1100W AC Power Supply
Module – to support power redundancy
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.5
iPC A2U44X25NVMEDK – (4) PCIe* SSD SFF (NVMe*)
+ (4) SAS support – requires use of one PCIe* slot. See chapter 5.2 and/or System TPS for details
8x2.5” Drive Bay Module upgrade kit. See chapter 5.5
for available options.
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW
RAID-5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
26
Product Code (iPC):
R2208WTTYS
2U – 8 x 2.5” front mount drives
Order Code Information:
MM# – 936023
UPC – 00735858289450
EAN – 5032037068437
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 22.9 Kgs, 50.5 Lbs Un-packaged Net Weight: 16.2 Kgs, 35.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2208WTTYS includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (1) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 3-slot PCIe* riser cards – iPC A2UL8RISER2 o Includes (1) 2-slot low profile PCIe* riser card – iPC A2UX8X4RISER
(1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 300mm optical drive / internal mount SSD power cable
iPN H23901-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12Gb SAS backplane – iPC A2U8X25S3HSDK
Includes (8) 2.5” hot swap drive trays – iPC FXX25HSCAR2
(2) – Multiport 730mm SAS/SATA data cables – iPC AXXCBL730HDHD (1) – Backplane 250mm I2C cable – iPN G41809-00x (1) – Backplane power cable – iPN H23927-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x
Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC AXX1100PCRPS – 1100W AC Power Supply
Module – to support power redundancy
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.5
iPC A2U44X25NVMEDK – (4) PCIe* SSD SFF (NVMe*)
+ (4) SAS support – requires use of one PCIe* slot. See chapter 5.2 and/or System TPS for details
8x2.5” Drive Bay Module upgrade kit. See chapter 5.5
for available options.
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW
RAID-5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
27
Product Code (iPC):
R2208WTTYC1
2U – 8 x 2.5” front mount drives
Order Code Information:
MM# – 936033
UPC – 00735858289443
EAN – 5032037068420
MOQ – 1
Product Type: L6 Integrated System
Special - Features to support passive Intel® Xeon Phi™ coprocessor
NOTE: Intel® Xeon Phi™ cards with Active heat sinks are NOT supported in this SKU.
Chassis Form Factor: 2U Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 22.9 Kgs, 50.5 Lbs Un-packaged Net Weight: 16.2 Kgs, 35.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2208WTTYC1 includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (2) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 2-slot PCIe* riser cards – iPC A2UL16RISER2 o Includes (1) 2-slot low profile PCIe* riser card – iPC A2UX8X4RISER
(1) – High air flow air duct (iPC AWTCOPRODUCT) (1) – Intel® Xeon Phi™ / GPGPU Secure Mount Adapter Bracket kit (2) – 12V-Auxiliary Power Cables – iPC AXXGPGPUCABLE (6) – Hot swap system fans – iPC FR2UFAN60HSW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 300mm optical drive / internal mount SSD power cable –
iPN H23901-00x
(8) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC A2U8X25S3HSDK
Includes (8) 2.5” hot swap drive trays – iPC FXX25HSCAR2
(2) – Multiport 730mm SAS/SATA data cables – iPC AXXCBL730HDHD (1) – Backplane 250mm I2C cable – iPN G41809-00x (1) – Backplane power cable – iPN H23927-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x
Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (2) AC power cords
Optional Intel Accessories – Sold Separately
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.5
iPC A2U44X25NVMEDK – (4) PCIe* SSD SFF (NVMe*)
+ (4) SAS support – requires use of one PCIe* slot. See chapter 5.2 and/or System TPS for details
8x2.5” Drive Bay Module upgrade kit. See chapter 5.5
for available options.
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW
RAID-5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
28
Product Code (iPC):
R2308WTTYS
2U – 8 x 3.5” HDD or 8 x 2.5” SSD front mount drives
Order Code Information:
MM# – 936035
UPC – 00735858283854
EAN – 5032037064866
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 23.5 Kgs, 51.8 Lbs Un-packaged Net Weight: 16.1 Kgs, 35.5 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2308WTTYS includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (1) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 3-slot PCIe* riser cards – iPC A2UL8RISER2 o Includes (1) 2-slot low profile PCIe* riser card – iPC A2UX8X4RISER
(1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (1) – Standard control panel assembly (board only – iPC FXXFPANEL) (1) – Front I/O Panel assembly (1 x VGA and 2 x USB) (1) – SATA Optical drive bay with filler panel – (optical drive sold seperately)
Includes optical drive mounting latch kit – iPN H19168-00x
Includes 500mm optical drive / internal mount SSD power cable –
iPN G95878-00x
(8) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC F2U8X35S3HSBP
Includes (8) 3.5” hot swap drive carriers – iPC FXX35HSCAR
(1) – Backplane power cable – iPN H38457-00x (1) – Multiport 800mm SAS/SATA data cables – iPC AXXCBL800HDHD (1) – Multiport 950mm SAS/SATA data cables – iPC AXXCBL950HDHD (1) – Backplane I2C cable – iPN G92510-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (8) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) installed – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x
Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC AXX1100PCRPS – 1100W AC Power Supply
Module – to support power redundancy
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.3
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
iPC RKSATA4R5 – Embedded SATA ESRT2 SW
RAID-5 support key
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
29
Product Code (iPC):
R2312WTTYS
2U – 12 x 3.5” HDD or 12 x 2.5” SSD front mount drives
Order Code Information:
MM# – 936036
UPC – 00735858289474
EAN – 5032037068451
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 2U rack mount Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 24.4 Kgs, 53.8 Lbs Un-packaged Net Weight: 17.0 Kgs, 37.5 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2312WTTYS includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (1) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 3-slot PCIe* riser cards – iPC A2UL8RISER2
(1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (2) – Chassis Handles (1 set) installed – includes Integrated control panel &
USB Port - iPC A2UHANDLKIT (1) – 500mm internal mount SSD power cable – iPN G95878-00x (12) – 3.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (1) 12 Gb SAS backplane – iPC F2U12X35S3HSBP
Includes (12) 3.5” hot swap drive carriers – iPC FXX35HSCAR
(1) – Multiport 800mm SAS/SATA data cable – iPC AXXCBL800HDHD (1) – Multiport 875mm SAS/SATA data cable – iPC AXXCBL875HDHD (1) – Multiport 950mm SAS/SATA data cable – iPC AXXCBL950HDHD (1) – Backplane I2C cable – iPN G92510-00x (1) – Backplane power cable – iPN G92685-00x (2) – 2.5” Rear Mount Hot Swap Drive Bays with drive carriers, drive blanks,
SATA data/SGPIO cable harness, and I2C cable (Intel Accessory Kit – iPC
A2UREARHSDK) (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (16) – DIMM slot blanks – iPN G75158-00x (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x
Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC AXX1100PCRPS – 1100W AC Power Supply
Module – to support power redundancy
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
Intel® SAS Expander – See Chapter 4.6.2 for available
options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.4
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
30
Product Code (iPC):
R2224WTTYS
2U – 24 x 2.5” front mount drives
Order Code Information:
MM# – 936037
UPC – 00735858289467
EAN – 5032037068444
MOQ – 1
Product Type: L6 Integrated System Chassis Form Factor: 2U Chassis dimensions: L=712mm, W=439mm, H=89mm
Packaged Gross Weight: 25.0 Kgs, 55.1 Lbs Un-packaged Net Weight: 18.3 Kgs, 40.3 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
Product Definition and Configuration Requirements/Options
Intel product code R2224WTTYS includes the following:
(1) – 2U Chassis with Quick Reference Label affixed to top cover (1) – Intel® Server Board S2600WT w/ Dual 10GbE – iPC S2600WTT (1) – 1100W AC Power Supply Module – iPC AXX1100PCRPS (1) – Power supply bay blank insert (2) – AC Power Cord retention strap assembly – iPN H23961-00x (2) – PCIe Riser card brackets
o Includes (2) 3-slot PCIe* riser cards – iPC A2UL8RISER2 (1) – Air duct (6) – Hot swap system fans – iPC FR2UFAN60HSW (2) – Chassis Handles (1 set) installed – includes Integrated control panel &
USB Port - iPC A2UHANDLKIT (24) – 2.5” Hot-swap drive bays with drive carriers and drive blanks
Includes (3) 12 Gb SAS backplanes – iPC A2U8X25S3HSDK
Includes (24) 2.5” hot swap drive trays – iPC FXX25HSCAR2
Includes (2) backplane to backplane I2C jumper cables – iPN
G17347-00x (1) – Backplane power cable – iPN H23927-00x (2) – 2.5” Rear Mount Hot Swap Drive Bays with drive carriers, drive blanks,
SATA data/SGPIO cable harness, and I2C cable (Intel Accessory Kit – iPC
A2UREARHSDK) (2) – Multiport 730mm SAS/SATA data cables – iPC AXXCBL730HDHD (4) – Multiport 875mm SAS/SATA data cables – iPC AXXCBL875HDHD (1) – Backplane 250mm I2C cable – iPN G41809-00x (1) – Rear Backplane power cable – iPN H24615-00x (2) – CPU heatsinks – iPC FXXCA84X106HS (2) – CPU heat sink Mylar Spacer inserts – iPN H28618-00x (16) – DIMM slot blanks – iPN G75158-00x (2) – Chassis handle (1 set) – iPN H18229-xxx (1) – 3x RMFBU Mounting Bracket – iPN H18238-00x Spares for each screw type included
Required Items – Sold Separately:
Rack Mount Kit – See chapter 5.11 for
available options
1 or 2 Intel® Xeon® Processor E5-2600
v3 product family
ECC DDR4 memory (RDIMM or
LRDIMM)
Power Cord(s) – See chapter 5.10 NOTE: L6 Systems shipping from Intel to North America will include (1) AC power cord
Optional Intel Accessories – Sold Separately
iPC AXX1100PCRPS – 1100W AC Power Supply
Module – to support power redundancy
Intel® I/O Module - See chapter 5.8 for available
options
Intel® 12G SAS RAID module + RMFBU - See chapter
5.9 for available options
Intel® SAS Expander – See Chapter 4.7.4 for available
options
SAS Data cables – Depending on the location of the
SAS Data controller, new data cables may be necessary. See chapter 4.2.5
iPC A2UBEZEL – Lockable
front system bezel
iPC AXXRMM4LITE - Intel® Remote Management
Module Lite key – For advanced management features
Storage Drives
See Chapter 5 for all available accessory options.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
31
4. SAS / SATA Data Cable Guide
By default, all L6 integrated system will include SAS / SATA data cables routed from the front hot swap backplane to the on-board SATA controller connectors. SAS data cables may need to be ordered seperately when adding a SAS RAID module or SAS RAID PCIe* add-in card to an integrated system SKU.
SAS / SATA data cables are NOT included with any of the chassis only building block SKUs. They must be ordered seperately to match the desired system configuration.
4.1 SAS / SATA Data Cable Connector Types
There are three storage interface connector types used within this product family:
Single Port SATA Connector
Image
Description
7-pin Single Port SATA Support for up to 6 GB/sec SATA devices
Where used:
- On the server board – (2) single port SATA connectors (SATA 4, SATA 5)
- 2U Rear Mount Hot-Swap Backplane (iPC A2UREARHSDK)
- SATA Optical Drive – CD/DVD
- SATA DOM
Multiport MiniSAS HD Connectors
Image
Description
SFF-8643
Support for up to 12 Gb/Sec SAS and 6 Gb/sec SATA devices
PCIe* (NVMe) SFF support associated with Intel Accessory Kits A1U44X25NVMEDK &
A2U44X25NVMEDK
Where used:
- On the server board – (2) 4-port SATA connectors (SATA 0-3, sSATA 0-3)
- All 12 Gb/sec SAS capable hot swap backplanes
- All 12 Gb/sec SAS RAID Controllers
- All 12 Gb/sec SAS Expander Cards
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
32
Multiport MiniSAS Connector
Image
Description
SFF-8087 Support for up to 6 Gb/Sec SAS / SATA devices
Where used:
- All 6 Gb/sec SAS RAID Controllers
- All 6 Gb/sec SAS Expander Cards
When connecting a 6Gb/sec SAS Controller or SAS Expander to a 12 Gb/sec capable hot swap backplane, the data cables used will need a SFF-8643 connector on one end of the cable and a SFF-8087 connector on the other. See Table 11. Storage Data Cable Kit Description and Order Information for appropriate cable kits.
4.2 1U / 2U Server System SAS / SATA Cable Guide
Product tables in this section will reference SAS/SATA cables using different connector types to meet the connection and routing requirements for the specified system configuration. Each cable reference and product code will identify the connector type at each end of the cable using the following identifiers: HR, HD, and
MS. The following table identifies the three cable connector types and their identifiers.
HR = Right Angle SFF-8643 Mini SAS HD Connector
HD = Straight SFF-8643 Mini SAS HD Connector
MS = Straight SFF-8087 Mini SAS Connector (compatible with 6Gb/sec SAS controllers and expanders)
Cable Kit Product Code Example - AXXCBL950HDMS AXXCBL – Identifies an accessory cable kit 950 – identifies the length of the cable HD – identifies that one end of cable connector supports SFF-8643 connector
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
33
System illustrations in each of the following sections will denote drive numbering as shown below:
Drive numbering in the system illustrations is for general reference only. Actual drive numbering will be dependant on SAS / SATA controller configuration and how they are cabled to the backplane. Each installed backplane will include a multi-port data connector for each set of four drives. Example) for an 8 drive configuration (as shown above), the backplane will include 2 four port data connectors. In the illustration, drives showing a common color for the Drive ID label will share a common data connector on the backside of the baclplane.
Each table in the following sections identify the cable connections and recommended cable lengths for each supported storage controller option in the specified system. Each “recommended” cable length for a given connector pair provides enough cable to attach the two devices and provides the least amount of access cable, providing the cleanest cable routing.
In the given server system, no cables should be routed in front of the system fans or in between the processors and memory slots. All cables that require routing from the front of the system to the back, are routed within the cable channels along the chassis sidewalls.
Intel® Server System R1000WT
product family cable routing
Intel® Server System R2000WT
product family cable routing
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
34
4.2.1 1U 4 x 3.5” – R1304WTxxx SAS / SATA Data Cable Guide
System
Configuration
Drive Support
Cables for On-board
Multi-port SATA
Ports to Baclpane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for 12 Gb SAS
RAID PCIe* add-in card
to Backplane
Cables for 6 Gb SAS
RAID PCIe* add-in card
to Backplane
R1304WTxxx R1304WTTGS R1304WT2GS
4 x 3.5”
12 Gb SAS capable
Cable Connections:
SATA -> BP 0-3
800 mm HR --- HD
From data above, select appropriate cable kit from list below:
AXXCBL1UHRHD
Cable included with L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
800 mm HD --- HD
From data above, select appropriate cable kit from list below:
AXXCBL800HDHD
Cable Connections:
SAS Mezz -> BP 0-3
800 mm HD --- MS
From data above, select appropriate cable kit from list below:
AXXCBL800HDMS
From Riser #1
Cable Connections:
SAS PCIe -> BP 0-3 **
875 or 950 mm HD --- HD
From Riser #2
Cable Connections:
SAS PCIe -> BP 0-3 **
730 or 875 mm HD --- HD
From data above, select appropriate cable kits from list below: See ** note below
AXXCBL730HDHD AXXCBL875HDHD AXXCBL950HDHD
From Riser #1
Cable Connections:
SAS PCIe -> BP 0-3 **
875 or 950 mm HD --- MS
From Riser #2
Cable Connections:
SAS PCIe -> BP 0-3 **
730 or 875 mm HD --- MS
From data above, select appropriate cable kits from list below: See ** note below
AXXCBL730HDMS AXXCBL875HDMS AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
35
4.2.2 1U 8 x 2.5” – R1208WTxxx SAS / SATA Data Cable Guide
Note: For data cable information associated with Intel® Accessory Kit A2U44X25NVMEDK, see section 5.1.1
System
Configuration
Drive Support
Cables for On-board
Multi-port SATA
Ports to Backplane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for 12 Gb SAS
RAID PCIe* add-in card
to Backplane
Cables for 6 Gb SAS
RAID PCIe* add-in card
to Backplane
R1208WTxxx R1208WTTGS R1208WT2GS
8 x 2.5”
12 Gb SAS capable
Cable Connections:
SATA -> BP 0-3
730 mm HR --- HD
sSATA -> BP 4-7
800 mm HR --- HD
From data above, select appropriate cable kits from list below:
AXXCBL1UHRHD
1 of each cable included with L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
650 mm HD --- HD
SAS Mezz -> BP 4-7
800 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL650HDHD AXXCBL800HDHD
Cable Connections:
SAS Mezz -> BP 0-3
650 mm HD --- MS
SAS Mezz -> BP 4-7
800 mm HD --- MS
From data above, select appropriate cable kits from list below:
AXXCBL650HDMS AXXCBL800HDMS
From Riser #1
Cable Connections:
SAS PCIe -> BP 0-3
650 mm HD --- HD
SAS PCIe -> BP 4-7 **
730 or 800 mm HD --- HD
From Riser #2
Cable Connections:
SAS PCIe -> BP 0-3 **
650 or 730mm HD --- HD
SAS PCIe – BP 4-7 **
800 or 875 mm HD --- HD
From data above, select appropriate cable kits from list below: See ** notes below
AXXCBL650HDHD AXXCBL730HDHD AXXCBL800HDHD
AXXCBL875HDHD
From Riser #1
Cable Connections:
SAS PCIe -> BP 0-3
650 mm HD --- MS
SAS PCIe -> BP 4-7 **
730 or 800 mm HD --- MS
From Riser #2
Cable Connections:
SAS PCIe -> BP 0-3 **
650 or 730mm HD --- MS
SAS PCIe – BP 4-7 **
800 or 875 mm HD --- MS
From data above, select appropriate cable kits from list below: See ** notes below
AXXCBL650HDMS AXXCBL730HDMS AXXCBL800HDMS
AXXCBL875HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
36
4.2.3 2U 8 x 3.5” – R2308WTxxx Cable Guide
System
Configuration
Drive Support
Cables for On-
board Multi-port
SATA Ports to
Backplane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for 12 Gb SAS RAID
PCIe* add-in card to
Backplane
Cables for 6 Gb SAS RAID
PCIe* add-in card to
Backplane
R2308WTTYS
8 x 3.5”
12 Gb SAS
Capable
Cable Connections:
SATA -> BP 0-3
800 mm HD --- HD
sSATA -> BP 4-7
950 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL950HDHD
1 of each cable included with L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
800 mm HD --- HD
SAS Mezz -> BP 4-7
950 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL950HDHD
1 of each cable included with L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
800 mm HD --- MS
SAS Mezz -> BP 4-7
950 mm HD --- MS
From data above, select appropriate cable kits from list below:
AXXCBL800HDMS AXXCBL950HDMS
From Riser #1:
Cable Connections:
SAS PCIe -> BP 0-3 **
650 or 730 mm HD --- HD
SAS PCIe -> BP 4-7 **
800 or 950 mm HD --- HD
From Riser #2:
Cable Connections:
SAS PCIe -> BP 0-3 **
730 or 800 mm HD --- HD
SAS PCIe -> BP 4-7 **
730 or 800 mm HD --- HD
From data above, select appropriate cable kits from list below: See ** Notes below
AXXCBL650HDHD AXXCBL730HDHD AXXCBL800HDHD
(1) 800mm Included in L6
AXXCBL950HDHD
(1) 950mm Included in L6
From Riser #1
Cable Connections:
SAS PCIe -> BP 0-3 **
650 or 730 mm HD --- MS
SAS PCIe -> BP 4-7 **
800 or 950 mm HD --- MS
From Riser #2:
Cable Connections:
SAS PCIe -> BP 0-3 **
730 or 800 mm HD --- MS
SAS PCIe -> BP 4-7 **
730 or 800 mm HD --- MS
From data above, select appropriate cable kits from list below: See ** Notes below
AXXCBL650HDMS AXXCBL730HDMS AXXCBL800HDMS AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
37
4.2.4 2U 12 x 3.5 – R2312WTxxx Cable Guide
R2312WTxxx SAS / SATA Data Cable Guide (with No SAS Expander)
System
Configuration
Drive
Support
Cables for On-board
Multi-port SATA
Ports to Backplane
Cables for Onboard
SATA controller +
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for Onboard
SATA Controller +
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for Onboard SATA
controller + 12 Gb SAS
RAID PCIe* add-in card to
Backplane
Cables for Onboard SATA
controller + 6 Gb SAS
RAID PCIe* add-in card to
Backplane
R2312WTxxx
R2312WTTYS
With no SAS
Expander installed
12 x 3.5”
12 Gb SAS
Capable
Cable Connections:
SATA -> BP 0-3
800mm HD --- HD
sSATA Cntrl -> BP 4-7
875 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL875HDHD
1 of each cable included with L6 Integrated systems
Cable Connections:
SATA -> BP 0-3
800mm HD --- HD
SAS Mezz -> BP 4-7
875 mm HD --- HD
SAS Mezz -> BP 8-11
950 mm HD ---HD
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL875HDHD AXXCBL950HDHD
1 of each cable included with L6 Integrated systems
Cable Connections:
SATA -> BP 0-3
800mm HD --- HD
SAS Mezz -> BP 4-7
875 mm HD --- MS
SAS Mezz -> BP 8-11
950 mm HD ---MS
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD
(1) 800mm Included in L6 AXXCBL875HDMS AXXCBL950HDMS
Cable Connections:
SATA -> BP 0-3
800mm HD --- HD
From Riser #1
SAS PCIe -> BP 4-7 **
800 or 875 mm HD --- HD
SAS PCIe -> BP 8-11
875 mm HD ---HD
From Riser #2
SAS PCIe -> BP 4-7 **
730 or 875 mm HD --- HD
SAS PCIe -> BP 8-11 **
650 or 800 mm HD --- HD
From data above, select appropriate cable kits: See ** Notes below
AXXCBL650HDHD AXXCBL730HDHD AXXCBL800HDHD
(1) 800mm Included in L6
AXXCBL875HDHD
(1) 875mm Included in L6
AXXCBL950HDHD
(1) 950mm included in L6)
Cable Connections:
SATA -> BP 0-3
800mm HD --- HD
From Riser #1
SAS PCIe -> BP 4-7 **
800 or 875 mm HD --- HD
SAS PCIe -> BP 8-11
875 mm HD ---HD
From Riser #2
SAS PCIe -> BP 4-7 **
730 or 875 mm HD --- HD
SAS PCIe -> BP 8-11 **
650 or 800 mm HD --- HD
From data above, select appropriate cable kits from list below: See ** Notes below
AXXCBL650HDMS AXXCBL730HDMS AXXCBL800HDMS AXXCBL875HDMS AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
38
2U 12 x 3.5” – R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander)
SAS drive configurations consisting of more than 8 drives may require the addition of a SAS Expander card. In the 2U 12x3.5” system configuration, the SAS expander must be installed in any available PCIe add-in slot. Intel provides two SAS expander options to support this drive configuration:
Intel Product Code Order Information
Product Description Product Type
iPC – RES3FV288
Intel
®
RAID Expander
RES3FV288
MM# – 932895
UPC – 00735858287548
EAN – 5032037067287
MOQ = 5
SAS 3.0 12 Gb/s expander
Featuring 6Gbps data aggregation for 12Gbps data transfer with 6Gb/s devices
Low Profile MD2 PCIe* add-in card form factor
28 internal ports and 8 external ports
Redundant dual-port capable for HA and high performance systems
Power from PCIe x1
HD Mini-SAS 8643 Connectors
Kit includes: (1) SAS Expander card, (2) HD-HD 250mm Expander-to-RAID card cables, PCI brackets for Low profile and Full height
Required (sold separately): HD-HD SAS DATA Cables – Expander to backplane – See
Table 6
2U Accessory Kit
iPC – RES2SV240
Intel® RAID Expander
RES2SV240
MM# – 908137
UPC – 00735858216289
EAN – 5032037017053
MOQ - 5
SAS 2.0 6 Gb/s expander
Low Profile MD2 PCIe* add-in card form factor
24 Port 6Gb expander card with ports configurable for input or output
Power from PCIe x1 or 4-pin connector
Mini-SAS 8087 connectors
Kit includes: (1) 6 Gb/s SAS Expander card, (2) MS-MS 300mm Expander-to-6Gb/s RAID card cables, PCI brackets for Low profile and Full height , (4) MS-MS 650mm Expander-to-Backplane cables (cables not compatible in R2312WTxxx system)
Required (sold separately): MS-HD SAS Data Cables – See
Table 6
2U Accessory Kit
iPC – RES2SV240NC
Intel® RAID Expander
RES2SV240NC
MM# – 915431
UPC – 00735858221375
MOQ - 5
SAS 2.0 6 Gb/s expander
Low Profile MD2 PCIe* add-in card form factor
24 Port 6Gb expander card with ports configurable for input or output
Power from PCIe x1 or 4-pin connector
Mini-SAS 8087 connectors
Kit includes: (1) 6 Gb/s SAS Expander card (with no cables), PCI brackets for Low profile and Full height
Required (sold separately): MS-HD SAS Data Cables – See
Table 6
2U Accessory Kit
Note: The onboard SATA ports are not compatible with SAS Expander cards. The onboard SATA ports can only be cabled directly to a specified backplane.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
39
Table 6. 2U 12 x 3.5” – R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander)
System
Configuration
Drive Support
On-board Multi-
port SATA Ports
Mezzanine 12Gb
SAS ROC Module +
12 Gb SAS Expander
to Backplane
Mezzanine 6 Gb SAS
ROC module + 6 Gb
SAS Expander to
Backplane
12Gb SAS RAID PCIe*
add-in card + 12 Gb
SAS Expander to
Backplane
6Gb SAS RAID PCIe*
add-in card + 6 Gb
SAS Expander to
Backplane
R2312WTxxx
R2312WTTYS
With SAS Expander
installed
12 x 3.5”
12 Gb SAS Capable
Onboard SATA
controllers do not support SAS expanders.
If attaching the onboard SATA controller to the Backplane, then use cables that are included in the System SKUs.
For building block integration use cable kits:
AXXCBL800HDHD AXXCBL875HDHD
With 12 Gb SAS
Expander RES3FV288 installed in Riser #1:
- Use cables in
Expander Kit to attach SAS ROC to Expander Card
- Use the following
cables to attach Expander to Backplane:
Expander -> BP 0-3
800 mm HD --– HD
Expander -> BP 4-7
875 mm HD --- HD
Expander -> BP 8-11
950 mm HD ---HD
1 of each cable included with L6 Integrated systems
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL875HDHD
AXXCBL950HDHD
With 6 Gb SAS
Expander RES2SV240 installed in Riser #1:
- Use cables in
Expander Kit to attach SAS ROC to Expander Card
- Use the following
cables to attach Expander to Backplane:
Expander -> BP 0-3
800 mm HD --– MS
Expander -> BP 4-7
875 mm HD --- MS
Expander -> BP 8-11
950 mm HD ---MS
From data above, select appropriate cable kits from list below:
AXXCBL800HDMS AXXCBL875HDMS AXXCBL950HDMS
With 12 Gb PCIe RAID
and 12 Gb SAS Expander
RES3FV288
installed in
riser #1:
- Use cables in Expander
Kit to attach PCIe SAS card to Expander Card
- Use the following
cables to attach Expander to Backplane:
Expander -> BP 0-3
800 mm HD --– HD
Expander -> BP 4-7
875 mm HD --- HD
Expander -> BP 8-11
950 mm HD ---HD
From data above, select appropriate cable kits from list below:
AXXCBL800HDHD AXXCBL875HDHD AXXCBL950HDHD
With 6 Gb PCIe RAID and
6 Gb SAS Expander
RES2SV240
installed in
riser #1:
- Use cables in
Expander Kit to attach PCIe SAS card to Expander Card
- Use the following
cables to attach Expander to Backplane:
Expander -> BP 0-3
800 mm HD --– MS
Expander -> BP 4-7
875 mm HD --- MS
Expander -> BP 8-11
950 mm HD ---MS
From data above, select appropriate cable kits from list below:
AXXCBL800HDMS AXXCBL875HDMS AXXCBL950HDMS
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
40
Figure 7. Intel® RAID Expander RES3FV288 Connector Identification
Figure 8. Intel® RAID Expander RES2SV240 Connector Identification
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
41
4.2.5 2U 2.5” Front Mount Drive Bay Cable Guide
The front drive bay of the 2U system can support up to three 8x2.5” drive bay modules capable of supporting system configurations of 8 (R2208), 16 (R2216), or 24 (R2224) drives. Each 8x2.5” drive bay is numbered in sequence from 1 to 3, as shown below. Each installed 8x2.5” backplane will include at least two multi-port 8643 data connectors, each supporting a set of four drives. Note that some 8x2.5” backplane options include more than two 8643 connectors in order to support features available to the specific backplane.
Intel makes available several different 8x2.5” drive bay module options, each supporting a different feature set (see chapter 5). The system tables in this section define the SAS/SATA data cables required to support the specified drive bay location regardless of the backplane option installed.
Reference each table as appropriate to determine the cable requirements relevent to your specific drive bay configuration.
Note: For data cable information associated with Intel® Accessory Kit A2U44X25NVMEDK, see sections 5.2.1 and 5.2.2
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
42
2U 2.5” Front Mount Drive Configurations – SAS Data Cable Guide (with no SAS Expander)
Table 7. 2U 8 x 2.5" (Drive Bay #1) - SAS/SATA Data Cable Guid (with no SAS Expander)
System
Configuration
Drive Support
Cables for On-board
Multi-port SATA Ports
to Drive Bay #1
Cables for Mezzanine
12 Gb SAS ROC Module
to Drive Bay #1
Cables for Mezzanine 6
Gb SAS RAID module to
Drive Bay #1
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Drive Bay #1
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Drive Bay #1
Drive Bay #1
R2208… R2216… R2224…
8 x 2.5”
Cable Connections:
SATA Cntlr -> BP 0-3
730mm HD --- HD
sSATA Cntrl -> BP 4-7
730 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(2) 730mm Cables included with all 2.5” L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
730 mm HD --- HD
SAS Mezz -> BP 4-7
730 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(2) 730mm Cables included with all 2.5” L6 Integrated systems
Cable Connections:
SAS Mezz -> BP 0-3
730 mm HD --- MS
SAS Mezz -> BP 4-7
730 mm HD --- MS
From data above, select appropriate cable kits from list below:
AXXCBL730HDMS
From Riser #1:
Cable Connections:
SAS PCIe -> BP 0-3
730 mm HD --- HD
SAS PCIe -> BP 4-7
730 mm HD --- HD
From Riser #2
SAS PCIe -> BP 0-3
730 mm HD --- HD
SAS PCIe -> BP 4-7
730 mm HD --- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(2) 730mm Cables included with all 2.5” L6
Integrated systems
From Riser #1:
Cable Connections:
SAS PCIe -> BP 0-3
730 mm HD --- MS
SAS PCIe -> BP 4-7
730 mm HD --- MS
From Riser #2
SAS PCIe -> BP 0-3
730 mm HD --- MS
SAS PCIe -> BP 4-7
730 mm HD --- MS
From data above, select appropriate cable kits from list below:
AXXCBL730HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
43
For R2216WTxxx System configurations with no SAS Expander, reference Tables 7 and 8 for cabling guidance
Table 8. 2U 8 x 2.5” (Drive Bay #2) – SAS / SATA Data Cable Guide (with no SAS Expander)
System
Configuration
Drive Support
Cables for On-board
Multi-port SATA Ports
to Drive Bay #2
Cables for Mezzanine
12 Gb SAS ROC Module
to Drive Bay #2
Cables for Mezzanine
6 Gb SAS ROC module
to Drive Bay #2
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Drive Bay #2
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Drive Bay #2
Drive Bay #2
(no SAS
Expander)
R2216… R2224…
8 x 2.5”
Cable Connections:
SATA Cntlr -> BP 0-3
730mm HD -- HD
sSATA Cntrl -> BP 4-7
875mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(730mm Included in all
2.5” L6)
AXXCBL875HDHD
(875mm Included in R2224 L6)
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- HD
SAS Mezz -> BP 4-7
875mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD (730mm Included in all
2.5” L6)
AXXCBL875HDHD
(875mm Included in R2224 L6)
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- MS
SAS Mezz -> BP 4-7
875mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL730HDMS AXXCBL875HDMS
From Riser #1:
SAS PCIe -> BP 0-3 **
650 or 730mm HD -- HD
SAS PCIe -> BP 4-7 **
730 or 800mm HD -- HD
From Riser #2:
SAS PCIe -> BP 0-3 **
800 or 875mm HD -- HD
SAS PCIe -> BP 4-7 **
730 or 875mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL650HDHD AXXCBL730HDHD
(2) 730mm Included in all
2.5” L6
AXXCBL800HDHD AXXCBL875HDHD
(4) 875mm Included in R2224 L6)
From Riser #1:
SAS PCIe -> BP 0-3 **
650 or 730mm HD -- MS
SAS PCIe -> BP 4-7 **
730 or 800mm HD -- MS
From Riser #2:
SAS PCIe -> BP 0-3 **
800 or 875mm HD -- MS
SAS PCIe -> BP 4-7 **
730 or 875mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL650HDMS AXXCBL730HDMS AXXCBL800HDMS AXXCBL875HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
44
For R2224WTxxx System configurations with no SAS Expander, reference Tables 7, 8, and 9 for cable guidance for all three drive bay modules.
Table 9. 2U 8 x 2.5” (Drive Bay #3) – SAS / SATA Data Cable Guide (with no SAS Expander)
System
Configuration
Drive
Support
Cables for On-board
Multi-port SATA Ports
to Drive Bay #3
Cables for Mezzanine
12 Gb SAS ROC Module
to Drive Bay #3
Cables for Mezzanine
6 Gb SAS ROC module
to Drive Bay #3
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Drive Bay #3
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Drive Bay #3
Drive Bay #3
(no SAS
Expander)
R2224…
8 x 2.5”
Cable Connections:
SATA Cntlr -> BP 0-3
800mm HD -- HD
sSATA Cntrl -> BP 4-7
730mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(2) 730mm cables Included in all 2.5” L6)
AXXCBL800HDHD
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- HD
SAS Mezz -> BP 4-7
730mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD (2) 730mm cables Included in all 2.5” L6)
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- MS
SAS Mezz -> BP 4-7
730mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL730HDMS
From Riser #1:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- HD
SAS PCIe -> BP 4-7 **
800 or 950mm HD -- HD
From Riser #2:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- HD
SAS PCIe -> BP 4-7 **
650 or 800mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL650HDHD AXXCBL730HDHD
(2) 730mm Included in all
2.5” L6
AXXCBL800HDHD AXXCBL875HDHD
(4) 875mm Included in R2224 L6
AXXCBL950HDHD
From Riser #1:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- MS
SAS PCIe -> BP 4-7 **
800 or 950mm HD -- MS
From Riser #2:
SAS PCIe -> BP 0-3 **
800 or 875mm HD -- MS
SAS PCIe -> BP 4-7 **
650 or 800mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL650HDMS AXXCBL730HDMS AXXCBL800HDMS AXXCBL875HDMS AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
45
2U 2.5” Front Mount Drive Configurations – SAS Data Cable Guide (with SAS Expander)
SAS drive configurations consisting of more than 8 drives may require the addition of a SAS Expander card. In the 2U 16x2.5” or 24x2.5” system configurations, a SAS expander can be mounted in the area directly behind the drive bays. Intel provides two SAS expander options to support these drive configurations:
Intel Product Code Order Information
Product Description Product Type
iPC – RES3TV360
Intel® RAID Expander RES3TV360
MM# – 932894
UPC – 00735858287364
EAN – 5032037067102
MOQ - 5
SAS 3.0 12 Gb/s expander featuring 6Gbps data aggregation for 12Gbps data transferwith 6Gb/s devices
Internal mount mid-plane form factor
36 internal ports supporting point-to-pont 12, 6, and 3 Gb/s data
transfer rates
RA 4-pin power connector
HD Mini-SAS 8643 Connectors
Kit includes: (1) SAS expander card; (1) 130mm Power cable; (1 set) Expander-to-backplane cables: (4) HD-HD 165mm, (1) HD-HD 300mm, (1) HD-HD 250mm; (3) Rubber Pads; mounting screws
Required (sold separately)
HD-HD 12 Gb/sec Raid Controller-to-Expander cables – See table
section 4.7.3
HD-MS 6 Gb/s RAID Controller-to-Expander cables – See table
section 4.7.3
2U Accessory Kit
iPC – RES2CV360
Intel® RAID Expander RES2CV360
MM# – 918935
UPC –
00735858241168
EAN –
5032037035897
MOQ - 1
SAS 2.0 6 Gb/s expander
Internal mount mid-plane form factor
36 Port 6Gb expander card with ports configurable for input or output
Power from 4-pin connector
Mini-SAS 8087 connectors
Kit includes: (1) 6 Gb/s SAS Expander card; (1) 130mm power cable; (3) rubber mounting pads; (1 set) 6 Gb Expander to 6 Gb bacplane cables: (3) MS-MS 165mm, (2) MS-MS 185mm, (1) MS-MS 245mm (NOTE: included
data cables not compatible in R2312WT… system)
Required (sold separately): iPC – AXXCBLEXPHDMS - MS-HD 6Gb
Expander to 12 Gb Backplane Data Cable kit, SAS Data Cables from 6 Gb SAS RAID PCIe/Mezz Card to expander. See Table 10.
2U Accessory Kit
Note: The onboard SATA ports are not compatible with SAS Expander cards. The onboard SATA ports can only be cabled directly to a specified backplane.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
46
Table 10. 2U 2.5” Front Mount Drive Configurations with SAS Expander – SAS Data Cable Guide
Mezzanine 12Gb SAS
ROC Module to 12 Gb
SAS Expander
12Gb SAS RAID PCIe*
add-in card to 12 Gb
SAS Expander
Mezzanine 6 Gb SAS
ROC Module to 12 Gb
SAS Expander
6Gb SAS RAID PCIe*
add-in card to 12 Gb
SAS Expander
Mezzanine 6 Gb SAS
ROC Module to 6 Gb
SAS Expander
6Gb SAS RAID PCIe*
add-in card to 6 Gb
SAS Expander
12 Gb SAS Expander
RES3TV360 installed:
SAS Mezz -> Exp 0-3 (G)
730mm HD -- HD
SAS Mezz -> Exp 4-7 (H)
730mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL730HDHD
(2) 730mm cables Included in all 2.5” L6)
12 Gb SAS Expander
RES3TV360 installed:
From Riser #1:
SAS PCIe -> Exp 0-3 (G)
650mm HD -- HD
SAS PCIe -> Exp 4-7 (H)
650mm HD -- HD
From Riser #2:
SAS PCIe -> Exp 0-3 (G)
730mm HD -- HD
SAS PCIe -> Exp 4-7 (H)
730mm HD -- HD
From data above, select appropriate cable kits from list below:
AXXCBL650HDHD AXXCBL730HDHD
(2) 730mm cables Included
in all 2.5” L6)
12 Gb SAS Expander
RES3TV360 installed:
SAS Mezz -> Exp 0-3 (G)
730mm HD -- MS
SAS Mezz -> Exp 4-7 (H)
730mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL730HDMS
12 Gb SAS Expander
RES3TV360 installed:
From Riser #1:
SAS PCIe -> Exp 0-3 (G)
650mm HD --MS
SAS PCIe -> Exp 4-7 (H)
650mm HD --MS
From Riser #2:
SAS PCIe -> Exp 0-3 (G)
730mm HD --MS
SAS PCIe -> Exp 4-7 (H)
730mm HD -- MS
From data above, select appropriate cable kits from list below:
AXXCBL650HDMS AXXCBL730HDMS
6 Gb SAS Expander
RES2CV360 installed:
SAS Mezz -> Exp 0-3 (A)
730mm MS -- MS
SAS Mezz -> Exp 4-7 (B)
730mm MS -- MS
From data above, select appropriate cable kits from list below:
AXXCBL730MSMS
6 Gb SAS Expander
RES2CV360 installed:
From Riser #1:
SAS PCIe -> Exp 0-3 (G)
650mm MS --MS
SAS PCIe -> Exp 4-7 (H)
650mm MS --MS
From Riser #2:
SAS PCIe -> Exp 0-3 (G)
730mm MS --MS
SAS PCIe -> Exp 4-7 (H)
730mm MS -- MS
From data above, select appropriate cable kits from list below:
AXXCBL650MSMS AXXCBL730MSMS
12 Gb SAS Expander
to drive bays
12 Gb SAS Expander to
drive bays
12 Gb SAS Expander
to drive bays
12 Gb SAS Expander
to drive bays
6 Gb SAS Expander to
drive bays
6 Gb SAS Expander to
drive bays
Use cables included in
SAS Expander Kit
Use cables included in SAS
Expander Kit
Use cables included in
SAS Expander Kit
Use cables included in
SAS Expander Kit
Cable Kit Required:
iPC – AXXCBLEXPHDMS
Cable Kit Required:
iPC – AXXCBLEXPHDMS
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
47
Figure 9. – 12Gb Internal 36-Port Intel® RAID Expander Card RES3TV360 - Connector Identification Block Diagram
Figure 10. – 6 Gb Internal 36-Port Intel® RAIDExpander Card RES2CV360 - Connector Identification Block Diagram
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
48
4.3 Intel SAS / SATA Data Cable Kits
Each cable accessory kit referenced in the this section will identify the connector type at each end of the cable using the following identifiers: HR, HD, and MS. The following table identifies the three cable connector types and their identifiers.
HR = Right Angle SFF-8643 Mini SAS HD Connector
HD = Straight SFF-8643 Mini SAS HD Connector
MS = Straight SFF-8087 Mini SAS Connector (compatible with 6Gb/sec SAS controllers and expanders)
Cable Kit Product Code Decoder
Example – iPC AXXCBL950HDMS
AXXCBL – Identifies an accessory cable kit 950 – identifies the length of the cable HD – identifies that one cable connector supports an SFF-8643 type connector MS – identifies that one cable connector supports an SFF-8087 type connector
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
49
Table 11. Storage Data Cable Kit Description and Order Information
Image Order Information Description
iPC –
AXXCBL950HDHD
MM – 936122
UPC – 00735858286596
EAN – 5032037066495
MOQ – 1
950 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
Used in multiple systems as spare and/or accessory (1304, 2308, 2312)
iPC –
AXXCBL875HDHD
MM – 936123
UPC – 00735858284769
EAN – 5032037065054
MOQ – 1
875 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
Used in multiple systems as spare and/or accessory (1304, 1208 2208, 2312)
iPC – AXXCBL800HDHD
MM – 937312
UPC – 00735858286015
EAN – 5032037066006
MOQ – 1
800 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
Used in multiple systems as spare and/or accessory (1203, 1208, 2308, 2312)
iPC – AXXCBL730HDHD
MM – 936178
UPC – 00735858284745
EAN – 5032037065030
MOQ – 1
730 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
Used in multiple systems as spare and/or accessory (1208, 2208)
iPC – AXXCBL650HDHD MM – 937129 UPC – 00735858284752 EAN – 5032037065047 MOQ – 1
650 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
Used as accessory when installing 12G ROC module in 1208 for optimal cabling. (longer cable may be used)
iPC –
AXXCBL1UHRHD
MM – 937311
UPC – 00735858287401
EAN – 5032037067140
MOQ – 1
Combo cable kit, contains 2 cables. One of each of the following:
730mm (AXXCBL800HRHD),
800mm right angle SFF8643 to straight SFF8643,
Spare cables used in 1U WT systems to connect to onboard SATA ports.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
50
Image Order Information Description
iPC – AXXCBL950HDMS
MM – 937131
UPC – 00735858286633
EAN – 5032037066532
MOQ – 1
950 mm long, cable kit (2 cables included) straight SFF8643to straight SFF8087
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 with HBA, 2308 and 2312 HBA/module)
iPC – AXXCBL875HDMS
MM – 937130
UPC – 00735858286626
EAN – 5032037066525
MOQ – 1
875 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 and 1208 with HBA, 2216,2224,2312 with HBA/module)
iPC – AXXCBL800HDMS
MM – 937309
UPC – 00735858286084
EAN – 5032037066075
MOQ – 1
800 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 and 1208 with module, 2308 and 2312 HBA/module)
iPC – AXXCBL730HDMS
MM – 927238
UPC – 00735858266970
EAN – 5032037053648
MOQ – 5
730 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
Required in WT 2U systems with 6G SAS ROC module or 6G SAS HBA cards. (1208 with HBA, 2208 with HBA/module)
iPC – AXXCBL650HDMS
MM – 927237
UPC – 00735858266963
EAN – 5032037053631
MOQ – 5
650 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
Used as accessory when installing 6Gb ROC module in 1208 for optimal cabling. (longer cable may be used)
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
51
Image Order Information Description
iPC – AXXCBLEXPHDMS
MM – 937127
UPC – 00735858284776
EAN – 5032037065061
MOQ – 1
6 Gb Expander to 12 Gb Backplane cable kit
6Gb MS – to – 12Gb HD
(3) 165 mm, (1) 185 mm, (1) 245 mm, (1) 300 mm straight SFF8643 to straight SFF8087
iPC – AXXCBL650MSMS
MM – 918376
UPC – 00735858224444
EAN – 5032037019910
MOQ – 5
650 mm long, cable kit (2 cables included) straight SFF8087 to straight SFF8087
Required in WT 2U systems with 6Gb SAS ROC module or 6Gb SAS HBA cards. (1208 with HBA, 2208 with HBA/module) and 6 Gb Expander card
iPC – AXXCBL730MSMS
MM – 921049
UPC – 00735858245340
EAN – 5032037039864
MOQ – 1
730 mm long, cable kit (2 cables included) straight SFF8087 to straight SFF8087
Required in WT 2U systems with 6Gb SAS ROC module or 6Gb SAS HBA cards. (1208 with HBA, 2208 with HBA/module) and 6 Gb Expander card
iPC – AXXCBL880SATA
MM – 922988
UPC – 00735858250290
EAN – 5032037044806
MOQ – 10
Spare SATA ODD Data cable for rack chassis family – 880mm long
Included with ODD accessories
iPC - A2UCBLSSD
MM# – 937328
UPC – 00735858287005
EAN – 5032037066747
MOQ - 1
2U Cable kit accessory
This kit includes cables necessary to provide simultaneous support for up to two internal air duct mounted SATA SSDs + rear drive bay (iPC –
A2UREARHSDK)
Kit includes:
(1) Power Cable – Connectors to support rear drive bay and 2 internal mount SSDs (No CD/DVD Drive support)
(1) fan out multiport SATA Data cabe – Cable connectors include (1) HD mini-SAS SFF8643 + (4) 7-pin SATA + (1) SGPIO
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
52
5. Intel 1U / 2U System Configuration Options
The following sections identify available accessory kits supported within the Intel® S2600WT product family.
5.1 1U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit A1U44X25NVMEDK
The 8x2.5” combo backplane kit is capable of supporting a combination of both SAS devices and up to four PCIe* SFF (Small Form Factor) (NVMe) SSD drives
All eight drive connectors are capable of supporting a SAS device, but only four include SFF8639 connectors that can support PCIe* SFF (NVMe) SSDs
This kit is only supported in dual processor configurations
Intel Product Code Order Information
Product Description Product Type
iPC – A1U44X25NVMEDK
MM# – 936251
UPC – 00735858288873
EAN – 5032037068154
MOQ – 1
1U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane Kit
Kit IncludesL
(1) Combo Hot Swap Backplane PCBA
(4) SAS / SATA Hot Swap Drive Carriers (Green Latch)
(4) PCIe* SFF SSD (NVMe) Hot Swap Drive Carriers (Blue Latch)
(2) Dual PCIe* Port Cables
(1) PCIe x16 Add-in card
(1) Installation Guide
Required (Sold Separately):
SAS / SATA Data cables - See section 5.1.1
1U Accessory Kit
See the Intel® Server System R1000WT Technical Product Specification for additional information
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
53
5.1.1 1U 8x2.5” – Intel® Accessory Kit A1U44X25NVMEDK Cable Guide
Figure 11. 1U Combo Backplane (iPC – A1U44X25NVMEDK) Cable Routing
PCIe*
Port
0/1
PCIe*
SFF
Device 3
PCIe* SFF
Device 2
PCIe*
Port
2/3
PCIe*
SFF
Device 1
PCIe* SFF
Device 0
SAS Ports
0-3
SAS
Ports 4
-7
PCIe*
Port
0/1
PCIe* SFF
Device 3
PCIe* SFF
Device 2
PCIe*
Port
2/3
PCIe* SFF
Device 1
PCIe* SFF
Device 0
SATA
Ports
SATA Ports
4-7
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
54
Table 12. 1U 8x2.5" Combo Backplane SAS/SATA Cable Guide
System Configuration Drive Support
Cables for On-
board Multi-port
SATA Ports to
Backplane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb
SAS RAID module
to Backplane
Cables for 12 Gb SAS
RAID PCIe* add-in card to Backplane
Cables for 6 Gb SAS
RAID PCIe* add-in card to Backplane
R1208WTxxx R1208WTTGS R1208WT2GS
with
A1U44X25NVMEDK
A1U44X25NVMEDK
Accessory kit
Option
8 x 2.5” Combo
SAS / SATA + PCIe*
SSD SFF (NVMe)
12 Gb SAS capable
PCIe* cables included in accessory kit. For SAS/SATA support see the following options
730 mm HR --- HD
Connect cable to: SATA -> BP 0-3
and / or
800 mm HR --- HD Connect cable to: sSATA -> BP 4-7
Cables Included with system SKUs.
Cable kit required for building block integration: AXXCBL1UHRHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive
support
650 mm HD --- HD
Connect cable to: SAS Mezz -> BP 0-3
and/or
800 mm HD --- HD Connect cable to: SAS Mezz -> BP 4-7
Cable Kits Required:
AXXCBL650HDHD
and / or
AXXCBL800HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
650 mm HD --- MS
Connect cable to: SAS Mezz -> BP 0-3
and/or
800 mm HD --- MS Connect cable to: SAS Mezz -> BP 4-7
Cable Kits Required:
AXXCBL650HDMS
and / or
AXXCBL800HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
From Riser #1
730 mm HD --- HD Connect cable to: SAS PCIe -> BP 0-3
and/or
875 mm HD --- HD Connect cable to: SAS PCIe -> BP 4-7
Cable Kits Required:
AXXCBL730HDHD
and / or
AXXCBL875HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
From Riser #1
730 mm HD --- MS Connect cable to: SAS PCIe -> BP 0-3
and/or
875 mm HD --- MS Connect cable to: SAS PCIe -> BP 4-7
Cable Kits Required:
AXXCBL730HDMS
and / or
AXXCBL875HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
55
5.2 2U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit A2U44X25NVMEDK
The 8x2.5” combo backplane kit is capable of supporting a combination of both SAS devices and up to four PCIe* SFF (Small Form Factor) (NVMe) SSD drives
All eight drive connectors are capable of supporting a SAS device, but only four include SFF8639 connectors that can support PCIe* SFF (NVMe) SSDs
The PCIe* x16 interface add-in card MUST be installed in a x16 riser card (included), and is only supported in the Riser #2 slot of the server board.
This kit is only supported in dual processor configurations
The 2U system is limited to supporting only one combo backplane kit in addition to one or two other backplane options
The combo backplane module can only be supported in the first (left) drive bay when no other backplane module is installed
Due to thermal and power limits associated with 16 x 2.5” and 24 x 2.5” front drive configurations, the combo backplane module can only be supported in
the second (middle) drive bay
Intel Product Code Order Information
Product Description Product Type
iPC – A2U44X25NVMEDK
MM# – 936253
UPC – 00735858288880
EAN – 5032037068161
MOQ – 1
2U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane Kit
Kit Includes:
(1) 8x2.5” Drive Bay Assembly with backplane
(4) SAS / SATA Hot Swap Drive Carriers (Green Latch)
(4) PCIe* SFF SSD (NVMe) Hot Swap Drive Carriers (Blue Latch)
(2) Dual PCIe* Port Cables
(1) PCIe x16 Add-in card
(1) 2-slot PCIe Riser card PCBA and mounting screws
(1) I2C jumper cable (used in dual backplane configurations)
(1) Installation Guide
Required (Sold Separately):
SAS / SATA Data cables - See sections 5.2.1& 5.2.2
2U Accessory Kit
See the Intel® Server System R2000WT Technical Product Specification for additional information.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
56
Figure 12. 2U Combo Backplane (iPC – A2U44X25NVMEDK) Cable Routing
PCIe* SFF
Device
0/1
PCIe* SFF
Device
2/3
SAS Ports
0 - 3
SAS Ports
4 - 7
PCIe* SFF
Device
0/1
PCIe* SFF
Device
2/3
SATA Ports
0 - 3
SATA Ports
4 - 7
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
57
5.2.1 2U 8x2.5” – Intel® Accessory Kit A2U44X25NVMEDK SAS/SATA Cable Guide
Figure 13. Combo Backplane Module Placement – 8 x 2.5” front drive configurations
System
Configuration
Drive Bay #1
Cables for On-board
Multi-port SATA
Ports to Backplane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for 12 Gb SAS
RAID PCIe* add-in card to Backplane
Cables for 6 Gb SAS
RAID PCIe* add-in card to Backplane
R2208WT…
Drive Bay #1
populated
8 x 2.5” Combo
SAS / SATA + PCIe*
SSD SFF (NVMe)
iPC
A2U44X25NVMEDK
PCIe* cables included in accessory kit. For SAS/SATA support see the following options
730 mm HD --- HD
Connect cable to: SATA -> BP 0-3
Included w/system SKUs
and / or
730 mm HR --- HD Connect cable to: sSATA -> BP 4-7 Included w/system SKUs
Cable kit required for building block integration: (2) AXXCBL730HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive
support
730 mm HD --- HD
Connect cable to: SAS Mezz -> BP 0-3
Included w/system SKUs
and/or
730 mm HD --- HD Connect cable to: SAS Mezz -> BP 4-7 Included w/system SKUs
Cable kit required for building block integration: (2) AXXCBL730HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive
support
730 mm HD --- MS
Connect cable to: SAS Mezz -> BP 0-3
and/or
730 mm HD --- MS Connect cable to: SAS Mezz -> BP 4-7
Cable Kits Required: (1 or 2)
AXXCBL730HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive support
From Riser #1
730 mm HD --- HD Connect cable to: SAS PCIe -> BP 0-3
and/or
730 mm HD --- HD Connect cable to: SAS PCIe -> BP 4-7
Cable Kits Required: (1 or 2)
AXXCBL730HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive support
From Riser #1
730 mm HD --- MS Connect cable to: SAS PCIe -> BP 0-3
and/or
730 mm HD --- MS Connect cable to: SAS PCIe -> BP 4-7
Cable Kits Required: (1 or 2)
AXXCBL730HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive support
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
58
5.2.2 2U 16x2.5” / 24x2.5” –– Intel® Accessory Kit A2U44X25NVMEDK SAS / SATA Cable Guide
Figure 14. Combo Backplane Module Placement - 16 x 2.5” and 24 x 2.5” front drive configurations
System
Configuration
Cables for Drive
Bay #1
Drive Bay #2
Backplane Type
Cables for Mezzanine
12 Gb SAS ROC
Module to Drive Bay
#2
Cables for
Mezzanine 6 Gb SAS
RAID module to Drive
Bay #2
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Drive Bay #2
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Drive Bay #2
R2216WT… R2224WT…
See section 4.7.1
8 x 2.5” Combo
SAS / SATA + PCIe* SSD
SFF (NVMe)
iPC
A2U44X25NVMEDK
PCIe* cables included in accessory kit.
For SAS/SATA support see the following options
730mm HD --- HD
Connect cable to: SAS Mezz -> BP 0-3
and/or
800mm HD --- HD Connect cable to: SAS Mezz -> BP 4-7
One or both cable kits for building block integration: (1) AXXCBL730HDHD (1) AXXCBL800HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
730mm HD --- MS
Connect cable to: SAS Mezz -> BP 0-3
and/or
800mm HD --- MS Connect cable to: SAS Mezz -> BP 4-7
One or both cable kits for building block integration: (1) AXXCBL730HDMS (1) AXXCBL800HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD / NVMe drive support
From Riser #1
730 mm HD --- HD Connect cable to: SAS PCIe -> BP 0-3
and/or
800 mm HD --- HD Connect cable to: SAS PCIe -> BP 4-7
One or both cable kits for building block integration: (1) AXXCBL730HDHD (1) AXXCBL800HDHD
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive
support
From Riser #1
730 mm HD --- MS Connect cable to: SAS PCIe -> BP 0-3
and/or
800 mm HD --- MS Connect cable to: SAS PCIe -> BP 4-7
One or both cable kits for building block integration: (1) AXXCBL730HDMS (1) AXXCBL800HDMS
Use PCIe* cables included with Combo backplane kit for PCIe* SSD SFF / NVMe drive
support
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
59
5.3 2U Rear Mount Hot Swap Drive Bay Accessory Kit – iPC A2UREARHSDK
The 2U product family provides the option to support two 2.5” 6 Gb/sec hot swap SSDs installed to a modular drive bay mounted in the back of the system
Intel Product Code Order Information
Product Description Product Type
iPC – A2UREARHSDK
MM – 934976
UPC – 735858283298
EAN – 5032037064354
MOQ – 1
2U Rear Mount Hot Swap Drive Bay Accessory Kit
Kit Includes:
(1) Drive Bay Assembly and mounting hardware
(2) 2.5” Hot Swap Drive Carriers
(2) SATA Data Cables
(1) Power Cable
(1) I2C Cable
(1) SGPIO cable
2U Accessory Kit
System and Building Block
iPC - A2UCBLSSD
MM# – 937328
UPC – 735858287005
EAN – 5032037066747
MOQ - 1
2U Fixed Mount SSD + Rear Drive Bay Cable Kit
This kit includes cables to provide simultaneous support for up to two internal fixed mount SATA SSDs + rear drive bay
Kit includes:
(1) Power Cable – Connectors to support rear drive bay and 2 internal mount SSDs (No CD/DVD Drive support)
(1) Fan out multiport SATA Data cabe – Cable connectors include (1) HD mini-SAS SFF8643 + (4) 7-pin SATA + (1) SGPIO
2U Cable kit
accessory
Two 2.5” SATA Hot
Swap Drive Bay
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
60
5.4 2U 8x3.5” Front Mount Hot Swap Backplane Assembly - iPC A2U8X35S3HSDK
8x3.5” SAS/SATA Front Mount Hot-Swap Drive Bay Module option for 2U Building Block Chassis iPC – R2000WTxxx.
Intel Product Code Order Information
Product Description Product Type
iPC – A2U8X35S3HSDK
MM# – 936191
UPC – 00735858288781
EAN – 5032037068062
MOQ – 5
2U 8x3.5” Front Mount Hot Swap Backplane Assembly
Kit Includes: (1) Drive Bay Assembly Module (1) 8x3.5” hot swap backplane (8) 3.5” drive carriers + drive blanks (1) 175mm I2C Cable (1) 500mm ODD/SSD Power Cable (1) Chassis mounting clip (1 set) mounting hardware
Required (Sold Separately): SAS / SATA Data Cables. See section 4.2.3
2U Building Block
Accessory Kit
See the Intel® Server System R2000WT product family System Integration and Service Guide for complete kit installation instructions.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
61
5.5 2U 8x2.5” Drive Bay Module Options
2U system configurations that include support for 2.5” front mount storage devices can support up to three 8x2.5” drive bay modules. Intel makes available different types of 8x2.5” drive bay modules and can support from 1 to 3 of the same module or a mix of different modules. Only the PCIe* SSD (NVMe) compatible module (iPC – A2U44X25NVMEDK) has the limitation of only supporting one of these modules in combination with other backplane modules in the system.
Figure 15. R2208WT and R2216WT based system with Front I/O Module Bay Assembly
Figure 16. 2U 2.5" Drive Bay Numbering
Drive numbering in the illustrations above is for general reference only. Actual drive numbering will be dependant on SAS / SATA controller configuration and how they are cabled to the backplane. Each drive bay will include a single backplane. Each backplane will include a multi-port data connector for each set of four drives. Ex) for an 8 drive configuration, the backplane will include 2 four port data connectors. In the illustration above, drives showing a common Drive ID label color share a common data connector on the backside of the given backplane.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
62
R2208WT (8x2.5” – 1 drive bay) and R2216WT (16x2.5” – 2 drive bays) system configurations utilize the same front I/O module bay assembly containing the System
Control Panel and Front I/O Panel (as shown in Figure 9). When upgrading a R2208WT based system to an R2216WT based system, all that is needed is the removal of the Bay #2 face plate to insert the new drive bay, and adding the required data cables. No other chassis changes or additions are required.
Available SAS / SATA 8x25” accessory kits include the following.
Intel Product Code Order Information
Product Description Product Type
iPC – A2U8X25S3HSDK
MM# – 935066
UPC – 00735858288767
EAN – 5032037068048
MOQ – 1
8x2.5” SAS/SATA Front Mount Hot Swap Drive Bay Module for all 2U
2.5” systems
Kit Includes:
(1) Drive Bay Assembly Module
(1) 8x2.5” hot swap backplane
(8) 2.5” drive carriers + drive blanks
(1) 75mm I2C Backplane-to-Backplane jumper cable
(1 set) mounting hardware
Required (Sold Separately):
SAS / SATA Data Cables. See section 4.2.5
2U 2.5” Drive
Upgrade Kit
2U Building Block
Accessory Kit
Intel Product Code Order Information
Product Description Product Type
iPC – A2U8X25S3DPDK
MM# – 935067
UPC – 00735858288774
EAN – 5032037068055
MOQ – 1
8x2.5” Dual Port SAS Front Mount Hot Swap Drive Bay Module for all 2U 2.5” systems
Kit Includes:
(1) Drive Bay Assembly Module
(1) 8x2.5” hot swap backplane
(8) 2.5” drive carriers + drive blanks
(1) 75mm I2C Backplane-to-Backplane jumper cable
(1 set) mounting hardware
Required (Sold Separately):
SAS / SATA Data Cables. See section 4.2.5
2U 2.5” Drive
Upgrade Kit
2U Building Block
Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
63
For a 2U building block configuration consisting of 24x2.5” drives (3 drive bays – See Figure 10) or when upgrading a R2208WT or R2216WT system to a 24 drive R2224WT system, the 2U storage front panel option of Intel Accessory Kit A2UHANDLKIT must be installed.
Intel Product Code Order Information
Product Description Product Type
iPC – A2UHANDLKIT
MM# – 936038
UPC – 00735858288866
EAN – 5032037068147
MOQ – 1
1U / 2U Rack Handle Kit
This kit includes 3 different rack handles, including:
(1) Set of 2U storage rack handles with control panel and USB support
(R2312WT & R2224WT)
(1) Set of 2U non –storage rack handles
(R2208WT & R2216WT)
(1) Set of 1U rack handles
(R1304WT & R1208WT
2U – 24 2.5” Drive
Upgrade Kit
1U / 2U Spares Kit
See the Intel Server System R2000WT Product Family System Integration and Service Guide for complete system integration and upgrade instructions.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
64
5.6 Locking Front Bezel Accessory Kits
The optional front bezel is made of Black molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements. The front bezel includes a keyed locking mechanism which can be used to prevent unauthorized access to installed storage devices and front I/O ports.
5.6.1 2U Front Bezel Accessory Kit – iPC A2UBEZEL
Intel Product Code Order Information
Product Description Product Type
iPC – A2UBEZEL
MM# – 918086
UPC – 735858241137
EAN – 5032037035880
MOQ – 1
2U Front Bezel Accesory Kit
Kit Includes:
(1) 2U locking bezel (1) Front Panel Window Insert (1 Set) Bezel branding inserts – two ID badges, one wave
(1 Set) Keys
2U Accessory Kit
The face of the bezel assembly includes snap-in identification badge options and a wave feature option to allow for customization.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
65
5.6.2 1U Front Bezel Accessory Kit – iPC A1UBEZEL
Intel Product Code Order Information
Product Description Product Type
iPC – A1UBEZEL
MM# – 917983
UPC – 735858241120
EAN – 5032037035873
MOQ – 1
1U Front Bezel Accessory Kit
Kit Includes:
(1) 1U locking bezel (1) Front Panel Window Insert (1 Set) Bezel branding inserts – two ID badges, one wave
(1 Set) Keys
1U Accessory Kit
The face of the bezel assembly includes snap-in identification badge options and a wave feature option to allow for customization.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
66
5.7 1U / 2U PCIe* Riser Card Accessory/Spare FRU Options
The Intel® Server Board S2600WT provides three riser slots. Riser slots 1 and 2 are capable of supporting different riser card options to meet needs of specific system configurations. Riser card options for riser slots 1 and 2 are common. Riser slot 3 is only supported in 2U system configurations and can only support a riser capable of supporting low profile PCIe* add-in cards.
All PCIe* bus lanes to the riser slots are routed from the processors. Riser slot 1 has a total of 24 PCIe* 3.0 bus lanes routed from both processors; 16 lanes from procesor #1 and 8 lanes from processor #2. Riser slot 2 has a total of 24 PCIe* 3.0 bus lanes routed from CPU 2. For riser slot 3, all PCIe* bus lanes are routed from CPU 2; 8 PCIe* bus lanes are PCIe* 3.0 compatible and 4 PCIe* lanes are PCIe* 2.0 compatible. See the product Technical Product Specification (TPS) for additional information.
Riser slots 1 and 2 are capable of supporting up to 100W maximum power each. Available power to each add-in card slot on a given riser card is defined by the PCIe* specification. The server board provides two Auxiliary 12V power connectors that when cabled (iPC AXXGPGPUCABLE), can provide additional power to high power PCIe* add-in cards.
5.7.1 1U Riser Card Options
Intel Product Code Order Information
Product Description Product Type
iPC – F1UL16RISER2
MM# – 934884
UPC –
00735858288682
EAN –
5032037067966
MOQ – 1
1U 1-slot PCIe riser card option
One PCIe* add-in card slot – PCIe* x16, x16 mechanical
Kit includes: (1) Riser card PCBA
1U Building Block Accessory Kit
1U Spare FRU
Each riser card assembly has support for a single full height, ½ length PCIe* add-in card. However, riser card #2 may be limited to ½ length, ½ height add-in cards if either of the two mini-SAS HD connectors on the server board are used.
Note: Add-in cards that exceed the PCI specification for ½ length PCI add-in cards (167.65mm or 6.6in) may interfere with other installed devices on the server board.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
67
5.7.2 2U Riser Card Options
Intel Product Code Order Information
Product Description Product Type
iPC – A2UL8RISER2
MM# – 934885
UPC –
00735858288675
EAN –
5032037067959
MOQ – 1
2U 3-slot PCIe* riser card option
Riser Slots #1 & #2 Riser Card Option
Kit includes:
(1) riser card PCBA
Slot #
Description
Slot-1 (Top)
PCIe* x8 elec, x16 mechanical
Slot-2 (Middle)
PCIe* x8 elec, x16 mechanical
Slot-3 (Bottom) PCIe* x8 elec, x8 mechanical
2U Building Block Accessory Kit
2U Spare FRU
Each 3-slot riser card assembly has support for up to two full height full length add-in cards (top and middle slots) and one full height ½ length add-in card (bottom slot).
Intel Product Code Order Information
Product Description Product Type
iPC – A2UL16RISER2
MM# – 934886
UPC –
00735858288668
EAN –
5032037067942
MOQ – 1
2U 2-slot PCIe* Riser card option
Riser Slots #1 & #2 Riser Card Option
Kit includes:
(1) Riser card PCBA
(1) 12V-AUX Power Cable
Slot #
Description
Slot-1 (Top) PCIe* x16 elec, x16 mechanical Slot-2 (Bottom) PCIe* x8 elec, x8 mechanical
2U Building Block Accessory Kit
2U Spare FRU
* Required Kit for Intel® Xeon Phi™ or high power PCIe* add-in card support
Each 2-slot riser card assembly has support for one full height full length add-in card (top slot) and one full height ½ length add-in card (bottom slot).
Note: The A2UL16RISER2 accessory kit includes a 12V Auxiliary Power cable which can be used to provide additional 12V power for high power PCIe* add-in cards that require it. Note: The x16 2-slot riser card is included in Intel Accessory Kit A2U44X25NVMEDK. Systems configured with the A2U44X25NVMEDK accessory kit cannot support dual Intel® Xeon Phi™ coprocessor cards or dual non-Intel GPGPU cards.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
68
Intel Product Code Order Information
Product Description Product Type
iPC – A2UX8X4RISER
MM# – 934883
UPC –
00735858283311
EAN –
5032037064378
MOQ – 1
2U 2-slot riser card option
Riser Slot #3 (only) Riser Card Option
Kit includes:
(1) Riser card PCBA
Slot # Description
Slot-1 (Top)
PCIe* x4 elec, x8 mechanical (PCIe* 2.0 support only)
Slot-2
(Bottom)
PCIe* x8 elec, x8 mechanical
2U Building Block Accessory Kit
2U Spare FRU
Riser Slot #3 is provided to support up to two additional PCIe* add-in card slots for 2U server configurations. The available riser card option is designed to support low profile add-in cards only.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
69
5.8 Intel® I/O Expansion Modules
The Intel® S2600WT product family includes support for a number of optional Intel® I/O modules that install onto proprietary connectors on the server board leaving all available PCIe* add-in cards slots available for other add-in card options. The onboard high density interface connector has x8 PCIe* 3.0 bus lanes routed to it from CPU 1.
Figure 17. Intel® I/O Module Installation
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
70
Intel Product Code
Order Information Product Description
Product Type
iPC – AXX1P40FRTIOM
iPC – AXX2P40FRTIOM
MM# – 933742
UPC – 00735858282291
EAN –
5032037063623
MOQ – 1
MM# – 933743
UPC –
00735858282314
EAN – 5032037063647
MOQ – 1
Intel® I/O Modules AXX1P40FRTIOM
&
AXX2P40FRTIOM
Intel® Single and Dual-Port 40G QSFP+ Ethernet I/O Moduless based on XL710-AM2 10 Gigabit Ethernet Controller
On the dual port module, the 4x10GbE SFP+ break out is supported on Port 0 only
Available Optics Accessories:
Intel
®
Ethernet QSFP+ SR4 Optics, E40GQSFPSR
Intel
®
Ethernet 40G DCO Optics, E40GDCOQSFP
Connector and cables:
40GBASE-CR4, QSFP+ Direct Attached Copper Cable
Intel® Ethernet QSFP+ SR4 Optics also supported
Intel
®
Ethernet 40G DCO Optics, E40GDCOQSFP
Cabling type:
10GBASE-CR4: Copper Direct Attach passive cable (1–7m);
10GBASE-SR4: MMF (OM3) up to 100m
Intel
®
Ethernet 40G DCO Optics up to 50m
Kits Include:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker (2 Port only model)
(1 set) Mounting screws
1U / 2U
Accessory Kit
iPC – AXX10GBNIAIOM
MM# – 917905
UPC –
00735858241090
EAN –
5032037035842
MOQ – 1
Intel® I/O Module
AXX10GBNIAIOM
Dual SFP+ port 10GbE IO module based on Intel
®
82599ES 10 Gigabit
Ethernet Controller
Kit Includes:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker
(1 set) Mounting screws
1U / 2U
Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
71
Intel Product Code
Order Information Product Description
Product Type
iPC – AXX10GBTWLIOM3
MM – 941869
UPC –
00735858296656
EAN –
5032037072472
MOQ – 1
Intel® I/O Module AXX10GBTWLIOM3
Dual RJ-45 port 10GBASE-T IO module, based on Intel
®
Ethernet Controller
X540
Kit Includes:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker
(1 set) Mounting screws
1U / 2U
Accessory Kit
iPC – AXX1FDRIBIOM
MM – 918607
UPC –
00735858241106
EAN – 5032037035859
MOQ – 1
Intel® I/O Module AXX1FDRIBIOM
Single port, FDR 56GT/S speed Intel
®
I/O Expansion Infiniband* module
Kit Includes:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker
(1 set) Mounting screws
1U / 2U
Accessory Kit
iPC – AXX2FDRIBIOM
MM – 920627
UPC – 00735858245722
EAN – 5032037040235
MOQ – 1
Intel® I/O Module
AXX2FDRIBIOM
Dual port, FDR 56GT/S (per port capable) speed Infiniband* module
Kit Includes:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker
(1 set) Mounting screws
1U / 2U
Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
72
Intel Product Code
Order Information Product Description
Product Type
iPC – AXX4P1GBPWLIOM
MM – 917911
UPC – 00735858241083
EAN – 5032037035835
MOQ – 1
Intel® I/O Module
AXX4P1GBPWLIOM
Quad port 1GbE IO Module based on Intel
®
Ethernet Controller I350
Kit Includes:
(1) I/O module
(1) EMI shield
(1) Port Labeling Sticker
(1 set) Mounting screws
1U / 2U
Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
73
5.9 Intel® SAS RAID Add-in Cards, Modules, and Accessories
Intel® RAID offers a broad portfolio of RAID solutions designed to address the storage-related challenges of the modern day datacenter as well as the small business. The Intel® S2600WT product family includes support for the latest generation of 12 Gb/s SAS Intel® RAID add-in cards, modules, expanders, and accessories. Previous generation 6Gb/s Intel RAID cards can also be supported. See the published Tested Hardware and OS List for a full list of vaIidated Intel RAID cards.
Additional information for Intel RAID products can be found at the following Intel web sites:
http://www.intelraid.com/files/Intel_RMS3_Brief_Final.pdf http://www.intelraid.com/files/Intel- 1106- RAID- Brochure_New2014102.pdf http://www.intelraid.com/files/RAID_Matrix_20142.pdf
5.9.1 Intel® Integrated RAID Module RMS3 Product Family – SAS 3.0 (12 Gb/s)
Intel Product Code Order Information
Product Description Product Type
iPC – RMS3CC080
MM# – 932474
UPC – 00735858276832
EAN – 5032037060448
MOQ - 5
Intel® Integrated RAID Module RMS3CC080
Mezzanine Form Factor HW RAID Module
8 internal SAS / SATA ports
Mini-SAS HD SFF8643 connectors
LSI* SAS3108 ROC with 1GB DDR3
RAID Levels 0, 1, 5, 6, 10, 50, 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU5
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – RMS3CC040
MM# –932473
UPC – 00735858276849
EAN – 5032037060455
MOQ – 5
Intel® Integrated RAID Module RMS3CC040
Mezzanine Form Factor HW RAID Module
4 internal SAS / SATA ports
Mini-SAS HD SFF8643 connectors
LSI* SAS3108 ROC with 1GB DDR3
RAID Levels 0, 1, 5, 6, 10, 50, 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU5
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
74
Intel Product Code Order Information
Product Description Product Type
iPC – RMS3HC080
MM – 932469
UPC – 00735858276818
EAN – 5032037060424
MOQ – 5
Intel® Integrated RAID Module RMS3HC080
Mezzanine Form Factor Entry-RAID Module
8 internal SAS / SATA ports
Mini-SAS HD SFF8643 connectors
LSI* SAS3008 SAS IOC with Advanced Management
Entry HW RAID levels – JBOD, RAID 0,1,10 & Hybrid 5,50
128MB server board memory utilized as cache memory for RAID 5/50
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – RMS3JC080
MM – 932472
UPC – 00735858276825
EAN – 5032037060431
MOQ – 5
Intel® Integrated RAID Module RMS3JC080
Mezzanine Form Factor Entry-RAID Module
8 internal SAS / SATA ports
Mini-SAS HD SFF8643 connectors
LSI* SAS3008 IOC with Basic Firmware
Entry HW RAID levels – JBOD, RAID 0, 1, 1E, 10
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – AXXRMFBU5
MM# – 933907
UPC – 00735858276801
EAN – 5032037060417
MOQ – 5
Intel® RAID Maintenance Free Backup Unit AXXRFMBU5
A super-capacitor module and flash memory card designed to help protect data in dynamic memory during a power failure or system crash event.
The AXXRMFBU5 kit is used with the 12 Gb/s Intel® Integrated RAID Modules
Compatible with:
Intel® Integrated RAID Module RMS3CC080
Intel® Integrated RAID Module RMS3CC040
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
75
5.9.2 Intel® RAID Controller Add-in Cards - SAS 3.0 (12Gb/s)
Intel Product Code Order Information
Product Description Product Type
iPC – RS3DC080
MM# – 934643
UPC – 00735858265355
MOQ – 5
Intel® RAID Controller RS3DC080
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
8 internal SAS / SATA ports
LSI* SAS3108 ROC
RAID Levels – 0, 1, 5, 6, 10, 50, and 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU4
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – RS3DC040
MM# – 934644
UPC – 00735858265362
MOQ – 5
Intel® RAID Controller RS3DC040
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
4 internal SAS / SATA ports
LSI* SAS3108 ROC
RAID Levels – 0, 1, 5, 6, 10, 50, and 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU4
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – RS3SC008
MM# – 928223
UPC – 00735858266956
EAN – 5032037068567
MOQ – 5
Intel® RAID Controller
RS3SC008
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
8 external SAS / SATA ports
LSI* SAS3108 ROC
RAID Levels – 0, 1, 5, 6, 10, 50, and 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU4
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
76
Intel Product Code Order Information
Product Description Product Type
iPC – RS3MC044
MM# – 928244
UPC – 00735858266987
EAN – 5032037068574
MOQ – 5
Intel® RAID Controller RS3MC044
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
4 internal SAS / SATA ports + 4 external SAS / SATA ports
LSI* SAS3108 ROC
RAID Levels – 0, 1, 5, 6, 10, 50, and 60
Embedded 1GB DDR3 Cache Memory
Supports Maintenance Free Backup Unit – iPC AXXRMFBU4
SAS Data cables not included . Must be purchased seperately
1U / 2U Accessory Kit
iPC – RS3GC008
MM# – 928220
UPC – 00735858267175
EAN – 5032037053839
MOQ – 5
Intel® RAID Controller RS3GC008
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
Entry Level SAS Card
8 external SAS / SATA ports
LSI* SAS3008 IOC
RAID Levels – JBOD (SAS Connectivity)
SAS Data cables not included. Must be purchased seperately
1U / 2U Accessory Kit
iPC – RS3UC080
MM# – 928218
UPC – 00735858267649
EAN – 5032037053938
MOQ – 5
Intel® RAID Controller
RS3UC080
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
Entry Level SAS RAID Card
8 internal SAS / SATA ports
LSI* SAS3008 IOC
RAID Levels – 0, 1, 1E, 10, and JBOD
SAS Data cables not included. Must be purchased seperately
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
77
Intel Product Code Order Information
Product Description Product Type
iPC – RS3FC044
MM# – 928219
UPC – 00735858267267
EAN – 5032037053921
MOQ – 5
Intel® RAID Controller RS3FC044
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
Entry Level SAS RAID Card
4 internal + 4 external SAS / SATA ports
LSI* SAS3008 IOC
RAID Levels – 0, 1, 1E, 10, and JBOD
SAS Data cables not included. Must be purchased seperately
1U / 2U Accessory Kit
iPC – AXXRMFBU4
MM# – 937318
UPC –
00735858273787
EAN –
5032037058544
MOQ – 5
Intel® RAID Maintenance Free Backup Unit AXXRFMBU4
A super-capacitor module and flash memory card designed to help protect data in dynamic memory during a power failure or system crash event.
The AXXRMFBU4 kit is used with the 12 Gb/s Intel® RAID Controller PCIe* Add-in Cards
Compatible with:
Intel® RAID Controller RS3DC080
Intel® RAID Controller RS3DC040
Intel® RAID Controller RS3SC008
Intel® RAID Controller RS3MC044
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
78
5.9.3 Intel® RAID Accessory Options
Intel Product Code Order Information Product Description Product Type
iPC – AXXRPFKSSD2
MM# – 919499
UPC – 735858221467
EAN -
5032037051699
MOQ – 5
Intel® RAID SSD Cache with Fast Path I/O
Upgrade Key to enable SSD Cache with Fastpath I/O for Intel
®
’s RAID RS25 and RS3 (based on LSI 3108) families of ROC products.
1U / 2U Accessory Kit
iPC – AXXRPFKDE2
MM# – 915317
UPC – 735858221474
EAN -
5032037051705
MOQ – 5
Intel® RAID Drive Encryption Management
Upgrade Key to enable Drive Encryption Management for Intel
®
’s RAID RS25 and RS3 (based on LSI 3108) families of ROC products.
1U / 2U Accessory Kit
iPC – AXXRPFKSNSH2
MM# – 915318
UPC – 735858221481
EAN -
5032037051712
MOQ – 5
Intel® RAID Rapid RecoverySnapshot
Upgrade Key to enable Rapid Recovery Snapshot for Intel
®
’s RAID
RS25 and RS3 (based on LSI 3108) families of ROC products.
1U / 2U Accessory Kit
iPC – RKSATA4R5
MM# – 916346
UPC – 00735858238861
EAN – 5032037033640
MOQ - 5
ESRT2 SATA SW RAID activation key
Used to enable onboard SATA controllers to support embedded ESRT2 SW RAID 5
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
79
Intel Product Code Order Information Product Description Product Type
iPC – AXXRMFBU5
MM# – 933907
UPC – 00735858276801
EAN – 5032037060417
MOQ – 5
Intel® RAID Maintenance Free Backup Unit AXXRFMBU5
A super-capacitor module and flash memory card designed to help protect data in dynamic memory during a power failure or system crash event.
The AXXRMFBU5 kit is used with the 12 Gb/s Intel® Integrated RAID Modules
Compatible with:
Intel® Integrated RAID Module RMS3CC080
Intel® Integrated RAID Module RMS3CC040
1U / 2U Accessory Kit
iPC – AXXRMFBU4
MM# – 937318
UPC – 00735858273787
EAN – 5032037058544
MOQ – 5
Intel® RAID Maintenance Free Backup Unit AXXRFMBU4
A super-capacitor module and flash memory card designed to help protect data in dynamic memory during a power failure or system crash event.
The AXXRMFBU4 kit is used with the 12 Gb/s Intel® RAID Controller PCIe* Add-in Cards
Compatible with:
Intel® RAID Controller RS3DC080
Intel® RAID Controller RS3DC040
Intel® RAID Controller RS3SC008
Intel® RAID Controller RS3MC044
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
80
Intel Product Code Order Information Product Description Product Type
iPC - AWTAUXBBUBKT
MM# – 937082
UPC – 00735858289344
EAN – 5032037068321
MOQ – 1
1U / 2U RMFBU Mounting Option Kit
Kit includes:
(1) – 2U RMFBU Mounting plate. The mounting plate installs in one of two possible mounting locations in front of either riser slot on the 2U air duct and can support up to two AXXRMFBU5 or AXXRSBBU9 units. Full length PCIe cards cannot be supported when this mounting plate is installed behind the given riser slot.
(1) – RMFBU plastic housing bracket to support two stacked AXXRMFBU5 units in a 1U chassis
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
81
5.10 Intel Power Supply Modules and Power Cords
Intel Product Code Order Information Product Description Product Type
iPC – AXX1100PCRPS
MM# – 936183
UPC – 00735858287920
EAN – 5032037067478
MOQ - 1
1100W AC CRPS 80+ Platinum efficiency power supply module
Power cord sold separately
2U Building Block Option
2U Accessory Kit
2U Spare FRU
iPC – FXX750PCRPS
MM# – 915604
UPC – 00735858234979
EAN – 5032037030601
MOQ - 1
750W AC CRPS 80+ Platinum efficiency power supply module
Power cord sold separately
1U / 2U Building Block
Option
1U / 2U Accessory Kit
1U / 2U Spare FRU
iPC – AXX750DCCRPS
*Supported in Late Q2 2015
750W -48v DC (Direct current) CRPS 80+ Gold efficiency power supply module
Kit Includes: (1) power supply (1) O-ring terminal adapter. Power cable sold separately
1U / 2U Building Block
Option
1U / 2U Accessory Kit
1U / 2U Spare FRU
iPC – AXXDCCRPSCBL
MM – 922062
UPC –
00735858247993
EAN – 5032037042871
MOQ – 1
4000mm (13ft) DC power cable. Connects directly to power supply instead of O-ring terminals adapter
1U / 2U Accessory Kit
1U /2U Spare FRU
iPC – FPWRCABLENA
MM# – 879287
UPC – 00735858181129
EAN – 5032037015738
MOQ – 1
1500mm (59in) North American Power Cord
1U / 2U Accessory Kit
1U / 2U Spare FRU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
82
5.11 1U / 2U Rack Mount Kits
Caution: Exceeding the rail kit’s specified maximum weight limit or misalignment of the server in the rack may result in failure of the rack rails, resulting in damage to
the system or personal injury. Using two people or the use of a mechanical assist tool to install and align the server into the rack is highly recommended.
Intel Product Code Order Information Product Description Product Type
iPC - AXXPRAIL
MM# – 924417
UPC – 00735858219686
EAN – 5032037014823
MOQ – 1
1U / 2U Premium Rail Kit
1U and 2U compatible
Adjustment within 609.6mm~762mm to fit difference depth
rack
800mm maximum travel length
Full extension from rack
54 lbs (24 kgs) max support weight
Tool-less installation
Drop in system install
For Cable Management arm support – order iPC
AXX1U2UCMA
1U / 2U Accessory Kit
iPC – AXXELVRAIL
MM# – 920970
UPC – 00735858244367
EAN – 5032037038980
MOQ - 1
1U / 2U Enhanced Value Rail Kit
Works for all 438mm wide Intel
®
Rack Chassis 1U, 2U, 4U
Adjustment within 609.6mm~765mm to fit difference depth
rack
424.2mm maximum travel length
2/3 extension from rack
130 lbs (59 kgs) max support weight
Tool-less chassis attach
Tools required to attach to rails to rack
Note: No Cable Management Arm support.
1U / 2U Accessory Kit
iPC – AXX1U2UCMA
MM# – 913117
UPC – 00735858224604
EAN – 5032037019972
MOQ – 1
1U / 2U Cable Management Arm (CMA)
1U / 2U compatible
Support for Premium 1U/2U AXXPRAIL and 1U A1UFULLRAIL
rail kit options only
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
83
Intel Product Code Order Information Product Description Product Type
iPC - AXX2POSTBRCKT
MM# – 918808
UPC – 00735858245319
EAN – 5032037039833
MOQ – 1
1U / 2U 2-Post fixed mount bracket kit
1U and 2U compatible
Tools required to attach components to rack
NOTE
: Not compatible with 24x2.5” drive or 12x3.5” drive system
configurations
1U / 2U Accessory Kit
iPC – A1USHRTRAIL
NEW – COMING Q2 2015
1U Premium quality rails with no CMA support
Travel distance 780mm
Full extension from rack
Kit includes: Rails, screws, installation manual
1U Accessory Kit
iPC – A1UFULLRAIL
NEW - COMING Q2 2015
1U Premium quality rails with CMA support.
Travel distance 780mm
Full extension from rack
Kit includes: Rails, screws, installation manual
For Cable Management arm support – order iPC
AXX1U2UCMA
1U Accessory Kit
iPC – AXXFULLRAIL
NEW – COMING Q2 2015
2U+ Premium quality rails with CMA support.
Travel distance 780mm
Full extension from rack
Kit includes: Rails, screws, installation manual
For Cable Management arm – order iPC AXXCMA2
2U Accessory Kit
iPC – AXXCMA2
NEW – COMING Q2 2015
Cable management arm
Compatible with AXXFULLRAIL only
2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
84
5.12 Intel® Xeon Phi™ Coprocessor Card and Non-Intel GPGPU Support
Intel® Xeon Phi™ Coprocessor cards and non-Intel GPGPU cards are supported in the following 2U system configurations only: R2208WT, R2308WT, and R2216WT. Because of mechanical and themal limits, the 1U product family and the R2312WT… and R2224WT… system configurations do NOT have support for Intel® Xeon Phi™ coprocessor cards or non-Intel GPGPU cards.
Figure 18. Intel® Xeon Phi ™ Coprosessor Cards With Active and Passive Cooling
Supported 2U systems configured with the standard (default) air duct, can only support high power add-in cards (>75W) with active (with fan) heat sinks.
In supported 2U system, high power add-in cards (>75W) with passive (no fan) heat sinks can only be supported in systems configured with a high air flow air
duct available in Intel Accessory Kit – iPC AWTCOPRODUCT
o NOTE: Intel® Server System R2208WTTYC1 is a special system SKU that includes the necessary components to support passive high power (>75W)
add-in cards like the Intel® Xeon Phi™ coprocessor card or non-Intel GPGPU cards.
See the Intel® Server System R2000WT product family Technical Product Specification for more information.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
85
Non-Intel GPGPU Support Disclaimer:
Intel incorporates necessary features and conducts appropriate thermal testing of its server systems to ensure the thermal requirements of Intel® Xeon Phi™ coprocessor cards can be supported when the documented support criteria are met.
Intel can make support recommendations for non-Intel GPGPU cards listed on its Tested Hardware and Support List, based on the same support criteria. However, Intel cannot guarantee its server systems can meet the thermal requirements of these non-Intel high power add-in cards. System integrators should verify non-Intel GPGPU add-in card air flow and thermal requirements from vendor specifications before integrating them into the system. It is the responsibility of the system integrator to conduct appropriate system testing on server systems configured with a non-Intel GPGPU card to ensure reliable operation.
For non-Intel GPGPU cards listed on Intel’s tested hardware and OS list, Intel will provide best internal support efforts to duplicate and understand reported issues. However, Intel cannot guarantee an issue will be root caused nor that a fix can be made available to correct it.
Intel Product Code Order Information Product Description Product Type
iPC – AWTCOPRODUCT
MM# – 934988
UPC – 00735858283328
EAN – 5032037064385
MOQ – 1
2U High Air flow Air Duct Kit
Required 2U accessory kit when installing an Intel® Xeon Phi™ coprocessor card with passive heat sink (heat sink only, no fan)
Kit Includes:
(1) High air flow air duct
(1) Metal shipping bracket
(2) Non-intel GPGPU secure mounting adapters
Note: Intel Xeon Phi cards with active heat sinks are NOT supported in systems confgured with the high air flow air duct.
Note: Systems configured with any type of Intel® Xeon Phi™ card and/or non-Intel GPGPU card must have the shipping bracket installed before the system is exposed to any level of shock or vibration or is shipped to the end user location. Failure to install the shipping bracket has the potential to cause serious damage to various components within the system.
2U Accessory Kit
Each Intel
®
Xeon Phi™ coprocessor card and non-Intel GPGPU card must be installed into the top x16 slot of a 2-Slot PCIe* Riser card. With a 2-slot riser card installed, the embedded fan speed control will operate system fans at a higher speed. 3-slot riser cards (as shipped in the standard platform configuration) cannot be used due to air flow and thermal limitations.
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
86
Intel Product Code Order Information
Product Description Product Type
iPC – A2UL16RISER2
MM# – 934886
UPC –
00735858288668
EAN –
5032037067942
MOQ – 1
2U 2-slot riser card
Required 2U accessory kit when installing an Intel® Xeon Phi™ coprocessor or other Non-Intel GPGPU card
Kit includes:
(1) Riser card PCBA
(1) 12V-AUX Power Cable
Slot #
Description
Slot-1 (Top)
PCIe* x16 elec, x16 mechanical
Slot-2 (Bottom)
PCIe* x8 elec, x8 mechanical
2U Building Block
Accessory Kit
2U Spare FRU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
87
6. 1U / 2U Miscellaneous Accessory Options
Intel Product Code Order Information
Product Description Product Type
iPC – A1U2ULCP
MM# – 921028
UPC – 00735858245302
EAN – 5032037039826
MOQ – 1
Intel® Local Control Panel
A 1U / 2U front panel module which supports the following features:
2 line LCD screen
Customized messaging
Able to display critical system errors
When installed this module replaces the front I/O port module on R1304, R1208, R2308, R2208, and R2216 based systems. The LCP module re-uses the existing front USB port assembly from these systems. It does NOT support a front video connector.
This Kit is NOT compatible with R2224 and R2312 based systems.
See the Intel® Local Control Panel Technical Product Specification for more information
1U / 2U Accessory Kit
iPC – AXXSATADVDROM
MM# – 937569
UPC – 00735858197663
EAN – 5032037015127
MOQ – 1
Slimline SATA DVDROM Drive
Includes 880mm SATA cable
A peripheral power cable is included with the systems that have support for optical drives
Optical drives are not supported in R2312WT & R2224WT based systems
1U / 2U Accessory Kit
iPC – AXXSATADVDRWROM
MM# – 937575
UPC – 00735858197670
EAN – 5032037015134
MOQ - 1
Slimline SATA DVD+/-RW ROM Drive
Includes 880mm SATA cable
A peripheral power cable is included with the systems that have support for optical drives
Optical drives are not supported in R2312WT & R2224WT based systems
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
88
Intel Product Code Order Information
Product Description Product Type
iPC - AXXSSDODDKIT
MM# – 935065
UPC – 00735858288750
EAN – 5032037068031
MOQ – 1
1U fixed mount SSD mounting Kit
Tray is installed in the optical drive bay of 1U systems.
Kit includes:
(1) – Metal SSD mounting tray accomodates one 2.5” SATA SSD
(1) – 800mm SATA data cable
(1) – SSD peripheral power cable
Note: Maximum SSD thickness supported = 7mm
Note: Systems configured with this kit cannot support an additional optical drive
1U Accessory Kit
iPC - AXXRJ45DB93
MM# – 920430
UPC – 00735858242820
EAN – 5032037037525
MOQ – 1
Serial Port Cable Kit
This kit provides serial port cables for use with systems that include a back panel cut out to support a DB9 Serial ‘B’ port as routed from the server board and for systems that include an external RJ45 Serial ‘A’ port that need to convert the connector to a DB9 style connector.
Kit includes:
(1) - 1040mm Internal Serial ‘B’ port cable – Onboard DH10 header- to- External Mount DB9 – for 2U systems
(1) - 520mm Internal Serial ‘B’ port cable – Onboard DH10 header- to- External mount DB9 – for 2U systems
(1) – 100mm DCD RJ45 to DB9 Dongle
(1) – 100mm DSR RJ45 to DB9 Dongle
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
89
Intel Product Code Order Information
Product Description Product Type
iPC - AXXRMM4LITE
MM# – 911660
UPC – 00735858219297
EAN – 5032037014946
MOQ – 1
Intel® Remote Management Module 4 Lite Activation key
Installation of this activation key on to the server board enables support for the following advanced server management features:
Integrated KVM
Media Redirection
See the Intel Remote Management Module 4 and Integrated Web Console Users Guide for more information.
1U / 2U Accessory Kit
iPC - AXXTPME5
MM# – 919737
UPC – 00735858240352
EAN – 5032037035088
MOQ – 1
Intel® Trusted Platform Module (TPM)
A TPM is a hardware-based security device that addresses the growing concern on boot process integrity and offers better data protection. TPM protects the system start-up process by ensuring it is tamper-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions.
AXXTPME5 implements TPM as per TPM PC Client specifications revision 1.2 by the Trusted Computing Group (TCG)
1U / 2U Accessory Kit
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
90
7. 1U / 2U Spare and Replacement Parts (FRUs)
System integrators and distributors may choose to hold additional stock of individual system components. Intel makes available the following Spare and Replacement Parts (FRUs) compatible with the specified Intel server family.
Intel Product Code Order Information
Product Description Product Type
iPC – FXXFPANEL2
MM# – 937543
UPC – 00735858288712
EAN – 5032037067997
MOQ – 1
Front Panel board spare for use on 1U/2U rack systems (R1000, R2000 except R2224 and R2312) Rack chassis and P4000 Pedestal Chassis. Different from FXXFPANEL by 0.6mm offset of reset and power buttons.
1U / 2U Spare FRU
iPC – FXXCA84X106HS
MM# – 918318
UPC – 00735858236676
EAN - 5032037031448
MOQ – 2
1U Heat Sink FXXCA84X106HS (Cu/Al 84mmx106mm)
1U / 2U Spare FRU
iPC - FR1UFAN10PW
MM# – 935064
UPC – 00735858283342
EAN – 5032037064408
MOQ – 1
Three spare fans for 1U R1000WT system. 40x56mm dual rotor with 10p connector.
Includes 3 fans in the bracket, with grommets preinstalled.
1U Spare FRU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
91
Intel Product Code Order Information
Product Description Product Type
iPC - FR2UFAN60HSW
MM# – 934990
UPC – 00735858283359
EAN – 5032037064415
MOQ – 1
Two spare fans for 2U R2000WT system. 60x38mm, with hot swap connector.
Includes 2 fans with finger guards and housing.
2U Spare FRU
iPC – FR1304S3HSBP
MM# – 934887
UPC – 00735858288835
EAN – 5032037068116
MOQ – 1
Hot swap backplane board spare for 1U 4x3.5” chassis
(R1304 family).
1U Spare FRU
iPC – F1U8X25S3HSBP
MM# – 934888
UPC – 00735858288798
EAN – 5032037068079
MOQ – 1
Hot swap backplane board spare for 1U 8x2.5" chassis (R1208 family).
1U Spare FRU
iPC – FXX8X25S3HSBP
MM# – 934890
UPC – 00735858288804
EAN – 5032037068086
MOQ – 1
Single port hot swap backplane board spare for 2U 8x2.5" cage (R2200 and P4000 families).
Includes one backplane board.
2U Spare FRU
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
92
Intel Product Code Order Information
Product Description Product Type
iPC – F2U8X35S3HSBP
MM# – 934892
UPC – 00735858288811
EAN – 5032037068093
MOQ – 1
Hot swap backplane board spare for 2U 8x3.5" chassis (R2308 family).
Includes one backplane board.
2U Spare FRU
iPC – F2U12X35S3HSBP
MM# – 934893
UPC – 00735858288828
EAN – 5032037068109
MOQ – 1
Hot swap backplane board spare for 2U 12x3.5" chassis (R2312 family).
Includes one backplane board.
2U Spare FRU
iPC – A2UHANDLKIT
MM# – 936038
UPC – 00735858288866
EAN – 5032037068147
MOQ – 1
1U / 2U Rack Handle Kit
This kit includes 3 different rack handles, including:
(1) Set of 2U storage rack handles with control panel and USB support
(R2312WT & R2224WT)
(1) Set of 2U non –storage rack handles
(R2208WT & R2216WT)
(1) Set of 1U rack handles
(R1304WT & R1208WT
2U – 24 2.5” Drive Upgrade
Kit
1U / 2U Spares Kit
Loading...