Intel P4304CR2LFKN User Manual

Thank you for buying an Intel® Server System. The following information will help you assemble your Intel® Server System and install components.
If you are not familiar with ESD [Electrostatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
This guide and other supporting documents are located on the web at:
http://www.intel.com/support.
G49309-003
(This page is intentionally left blank.)
i
Table of Contents
System Overview...................................................................................................................................................... 1
Intel® Server System P4308IP4LHGC ............................................................................................ 1
Intel® Server System P4308IP4LHJC ............................................................................................ 1
Intel® Server System P4308IP4LHJCL .......................................................................................... 1
Intel® Server System P4308IP4LHKC ............................................................................................ 2
Intel® Server System P4208IP4LHGC ............................................................................................ 2
Intel® Server System P4216IP4LHJC ............................................................................................ 3
Intel® Server System P4216IP4LHKC ............................................................................................ 3
Intel® Server System P4224IP4LHKC ............................................................................................ 4
Intel® Workstation System P4304CR2LFGN .............................................................................. 4
Intel® Workstation System P4304CR2LFJN ................................................................................ 5
Intel® Workstation System P4304CR2LFJNL.............................................................................. 5
Intel® Workstation System P4304CR2LFKN .............................................................................. 5
Hot Swap Hard Drive Bay Options and HDD Numbering .................................................... 6
General Installation Process ................................................................................................................................ 7
Preparing the System ............................................................................................................................ 7
Remove the Side Cover.......................................................................................................................... 7
Remove the Air Duct .............................................................................................................................. 7
Install the Processor(s) .......................................................................................................................... 7
Install Heat Sink(s) .................................................................................................................................... 8
Install DIMM Memory Modules............................................................................................................ 9
Install Tool-less CD-ROM or DVD-ROM Drive .............................................................................. 9
Install Hard Drive .................................................................................................................................... 10
Install PCI Card Assembly.................................................................................................................... 11
Install Intel® Remote Management Module 4 NIC (optional)............................................12
Install RMM4 EMI Cover (optional) ................................................................................................12
Install Alternate Serial Port (optional) ........................................................................................ 12
Install Intel® RAID Smart Battery (optional)..............................................................................13
Install Second Power Supply Module (optional)......................................................................13
Rack Mount Configuration (optional) ............................................................................................ 13
Install Feet (pedestal only) ................................................................................................................13
Install Air Duct ..........................................................................................................................................14
Install Side Cover ....................................................................................................................................14
Finishing Up ................................................................................................................................................14
Install Software ........................................................................................................................................14
Reference .................................................................................................................................................................... 15
HDD Cage Cable Connection.............................................................................................................. 15
Front Panel Controls and Indicators.............................................................................................. 16
Cable Routing Diagram ........................................................................................................................ 16
ii
Warning
Warning
Caution
Tools Required
Read all caution and safety
statements in this document before performing any of the instructions. Also see the Intel®
Server Board and Server Chassis Safety Information document at:
http://www.intel.com/support/ motherboards/server/sb/cs-010770
Installation and service of this product to be performed only by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.
Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components.
.htm for complete safety information.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2012, Intel Corporation. All rights reserved.
®
Intel
Server System P4000IP Family Product Configuration
Flat Blade
screwdriver
Phillips* screwdriver
Anti-static wrist strap
Hard DrivesSystem Fan Power Supply
Intel® Server System
P4308IP4LHGC
P4308IP4LHJC
P4308IP4LHJCL
P4308IP4LHKC
P4208IP4LHGC
Five
Hot Swap
System
Fans
(80 x 38 mm)
N/A
CRPS 750W
CRPS 1200W
Two Hot Swap
16 x 2.5" Hot Swap
8 x 3.5" Hot Swap
8 x 2.5" Hot Swap
24 x 2.5" Hot Swap
Two Hot Swap
CRPS 1600W
Two Hot Swap
P4216IP4LHJC
P4216IP4LHKC
P4224IP4LHKC
®
Intel
Intel® Workstation System
P4304CR2LFGN
P4304CR2LFJN
P4304CR2LFJNL
P4304CR2LFKN
Workstation System P4000CR Family Product Configuration
System Fan Power Supply
Two Fixed System Fans
(120x38mm)
Hard Drives
4 x 3.5 Fixed
One Hot Swap
CRPS 750W
One Hot Swap CRPS 1200W
One Hot Swap CRPS 1600W
= Configuration Feature
Thermal Operation and Configuration Requirements
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration guidelines:
• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time. Doing so may affect
long term reliability of the system.
• The CPU-1 processor and CPU heatsink must be installed.
DIMM Population on CPU-1: Install DIMMs in order; Channels A, B, C, and D. Start with 1st DIMM slot (blue) on each channel.
DIMM Population on CPU-2: Install DIMMs in order; Channels E, F, G, and H. Start with 1st DIMM slot (blue) on each channel.
• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive blank.
• The air duct must be installed at all times.
• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times.
• The system top-cover must be installed at all times.
1
System Overview
Server Board
Server Board
Intel® Server System P4308IP4LHGC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
N O
Q
R
S T U
750W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E
PCI Add-in Board Slot Covers
F
Knock-out Opening for I/O Modules
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
L
P
I
Padlock Loop
J
RMM4 Knockout
K
Hot-swap System Fan 5
L
Front Control Panel
M
Hot Swap System Fan 4
N
5.25” Peripheral Bays
O
Hot-swap System Fan 3
P
One 8x3.5” Hot-swap HDD Cage
Q R
Hot-swap System Fan 2
Hot Swap System Fan 1
S
Air Duct
T
PCI Card Retainer
U
Intel® Server System P4308IP4LHJC(L)
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
N O
Q
R
S T U
1200W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E F
PCI Add-in Board Slot Covers
G
Knock-out Opening for I/O Modules
Alternate RMM4 Knockout
H
L
I
Opening for SPDIF Cable
J
Padlock Loop RMM4 Knockout
K
Hot-swap System Fan 5
L
P
Front Control Panel
M
Hot-swap System Fan 4
N
5.25" Peripheral Bays
O
Hot-swap System Fan 3
P
One 8x3.5” Hot-swap HDD Cage
Q
Hot-swap System Fan 2
R
Hot-swap System Fan 1
S
Air Duct
T
PCI Card Retainer
U
2
System Overview
Server Board
Server Board
Intel® Server System P4308IP4LHKC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
L
M
N O
P Q R
S
T U
1600W Common Redundant Power Supply
A
AC Input Power Connecotor
B
I/O ports
C
Serial Port Knockout
D
A Kensington Cable Lock Mounting Hole
E
PCI Add-in Card Slot Covers
F
Knock-out Opening for I/O Modules
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
I
Padlock Loop
J
RMM4 Knockout
K
Hot Swap System Fan 5
L
Front Control Panel
M
Hot Swap System Fan 4
N
5.25” Peripheral Bays
O
Hot Swap System Fan 3
P
One 8x3.5” Hot-swap HDD Cage
Q
Hot-swap System Fan 2
R
Hot-swap System Fan 1
S
Air Duct
T
PCI Card Retainer
U
Intel® Server System P4208IP4LHGC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
N O
Q
R
S T U
750-W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E
PCI Add-in Board Slot Covers
F
Knockout Opening for I/O Module
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
I
L
P
Padlock Loop
J
RMM4 Knockout
K
Hotswap System Fan 5
L
Front Control Panel
M
Hotswap System Fan 4
N
5.25" Peripheral Bays
O
Hotswap System Fan 3
P
One 8x2.5 Hot-swap HDD Cage
Q
Hot-swap System Fan 2
R
Hot Swap System Fan 1
S
Air Duct
T
PCI Card Retainer
U
3
System Overview
Server Board
Server Board
Intel® Server System P4216IP4LHJC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
R
1200-W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E F
PCI Add-in Board Slot Covers
G
Knock-out opening for I/O modules
Alternate RMM4 Knockout
L
N O
P
Q
S T U
H
I
Opening for SPDIF Cable
J
Padlock Loop
RMM4 Knockout
K
Hot-swap System Fan 5
L
Front Control Panel
M
Hot-swap System Fan 4
N
5.25" Peripheral Bays
O
Hot-swap System Fan 3
P
Air Duct
Q
Hot-swap System Fan 2
R
Hot-swap System Fan 1
S
Two 8 x 2.5" Hot-swap HDD Cage
T
PCI Card Retainer
U
Intel® Server System P4216IP4LHKC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
R
1600-W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E F
PCI Add-in Board Slot Covers
G
Knock-out opening for I/O modules
Alternate RMM4 Knockout
H
L
I
Opening for SPDIF Cable
J
N O P Q
S T U
Padlock Loop
RMM4 Knockout
K
Hot-swap System Fan 5
L
Front Control Panel
M
Hot-swap System Fan 4
N
5.25" Peripheral Bays
O
Hot-swap System Fan 3
P
Air Duct
Q
Hot-swap System Fan 2
R
Hot-swap System Fan 1
S
Two 8 x 2.5" Hot-swap HDD Cage
T
PCI Card Retainer
U
4
System Overview
Server Board
Server Board
Intel® Server System P4224IP4LHKC
System Features and Components
A
B
C D
E
F
G
H
I
J
K
M
N O
Q R
U
1600-W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E
PCI Add-in Board Slot Covers
F
Knock-out opening for I/O modules
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
I
Padlock Loop
L
P
S T
J
RMM4 Knockout
K
Hot-swap System Fan 5
L
Frontt Control Panel
M
5.25” Peripheral Bays
N
Hot-swap System Fan 4
O
Hot-swap System Fan 3
P
Air Duct
Q
Hot-swap System Fan 2
R
Hot-swap System Fan 1
S
Three 8x2.5" Hot-swap HDD Cage
T
PCI Card Retainer
U
Intel® Workstation System P4304CR2LFGN
System Features and Components
A
B
C D
E
F
G
H
I
J
K
L
M
N O
P Q
R
750W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E F
PCI Add-in Board Slot Covers
G
Knock-out Opening for I/O Modules
Alternate RMM4 Knockout
H
I
Opening for SPDIF Cable
J
Padlock Loop RMM4 Knockout
K
Front Control Panel
L
CPU Zone System Fan (Fan 2)
M
5.25" Peripheral Bays
N
Air Duct
O
PCI Zone System Fan (Fan 1)
P
Fixed Hard Driver Carrier Tray
Q
PCI Card Retainer
R
5
System Overview
Server Board
Server Board
Intel® Workstation System P4304CR2LFJN(L)
System Features and Components
A
B
C D
E
F
G
H
I
J
K
L
M
N O
P Q
R
1200-W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E
PCI Add-in Board Slot Covers
F
Knock-out Opening for I/O Modules
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
I
Padlock Loop
J
RMM4 Knockout
K
Front Control Panel
L
CPU Zone System Fan (Fan 2)
M
5.25" Peripheral Bays
N
Air Duct
O
PCI Zone System Fan (Fan 1)
P
Fixed Hard Drive Carrier Tray
Q
PCI Card Retainer
R
Intel® Workstation System P4304CR2LFKN
System Features and Components
A
B
C D
E
F
G
H
I
J
K
L
M
N O
P Q
R
1600W Common Redundant Power Supply
A
AC Input Power Connector
B
I/O Ports
C
Serial Port Knockout
D
A Kensington* Cable Lock Mounting Hole
E
PCI Add-in Board Slot Covers
F
Knock-out Opening for I/O Modules
G
Alternate RMM4 Knockout
H
Opening for SPDIF Cable
I
Padlock Loop
J
RMM4 Knockout
K
Front Control Panel
L
CPU Zone System Fan (Fan 2)
M
5.25" Peripheral Bays
N
Air Duct
O
PCI Zone System Fan (Fan 1)
P
Fixed Hard Drive Carrier Tray
Q
PCI Card Retainer
R
6
System Overview
Hot Swap Hard Drive Bay Options and HDD Numbering
8 x 3.5"
Hot-Swap
Drive Cage
8 x 2.5"
Hot-Swap
Drive Cage
4567
0123
01234567
16 x 2.5"
Hot-Swap
Drive Cage
24 x 2.5"
Hot-Swap
20
212223
12
131415
891011
01234567
12
131415
16171819
891011
01234567
Drive Cage
Loading...