Insinkerator MSLV-10 Installation Manual

DISPOSER CONTROL CENTER
Installation Manual
Model MSLV
www.insinkerator.com/foodservice
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to physical injury.
Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual.
Part No. 15331 Rev. B
TABLE OF CONTENTS
FEATURES
Warranty ........................................................ 2
Introduction ................................................... 2
Features ......................................................... 2
Mounting the Control Center ......................... 2
Plumbing Connections .................................. 3
Electrical Connections ................................... 3
Time Delay relay ............................................ 4
Operating Instructions ................................... 4
Troubleshooting ............................................. 4
Schematic Wiring Diagrams ....................... 5-8
WARRANTY
FOODSERVICE DISPOSER CONTROL CENTER
LIMITED WARRANTY
InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for one year from the date of installa tion. The warranty includes parts and labor, pro vided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage. InSinkErator Foodservice disposer accessories are included in this warranty only if they are included in the original disposer purchase package.
INTRODUCTION
INTRODUCTION
The MSLV Control Center is CUL® US listed for use with InSinkErator Commercial Food Waste Disposers. See Table 1 for approved combinations and Table 2 for electrical specifications. The control center operates the disposer. Its main functions are:
• To start and stop the disposer.
• To start the water flow to the disposer.
LOW VOLTAGE CONTROL Controls operate on a 24 V solid state control circuit.
ENCLOSURE Stainless steel NEMA 4 construction.
ELECTRIC DISCONNECT SWITCH The lever switch on the front panel of the control center disconnects the line voltage. It interlocks with the front cover so that the cover cannot be opened unless the switch is in the off position.
NOTE: Use of the electrical disconnect switch results in a 30-second delay before system can be restarted. You must wait 30 seconds after reactivation of the line disconnect switch before system will start.
PUSH BUTTON OPERATION Push Black button to start disposer. Push Red button to stop disposer.
Mounting the Control Center
MOUNTING THE CONTROL CENTER
Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical position (door hinge is on the left - see Figure 1).
Locate control center within sight of disposer per local codes.
If box is mounted to the sink table, recess the box so that the buttons do not extend beyond the table’s edge.
4 MOUNTING HOLES FOR
¼” BO
LTS
6”
5½”
8¼”
Table 1. Approved Disposer and Control Center Combinations
Model Waste Disposer Model
MSLV-9 MSLV-10
MSLV-11 MSLV-12
Table 2. Electrical Specifications
Model Voltage Phase HP
MSLV-9 120 V 1/2 – 2
MSLV-10 208 – 240 V 1Ø 1/2 – 2
MSLV-11 208 – 240 V 3Ø 1/2 – 10
MSLV-12 380 – 460 V 3Ø 1/2 – 10
SS50-26, SS75-27, SS100-28, SS125-25, SS150-34, SS150-38, SS200-27. SS200-31
SS50-27, SS75-28, SS100-29, SS125-26, SS150-36, SS150-39, SS200-29, SS200-32, SS300-25, SS300-27, SS500-28, SS500-30, SS750-13, SS750-15, SS1000-10, SS1000-12
10¾”
6¼”
HINGE
BUT
Figure 1. Control center dimensions
2
S
TOP
TON
START
BUT
ELECTRICAL DISCONNECT
TON
SWITCH
10¼”
PLUMBING CONNECTIONS
PLUMBING CONNECTIONS
The solenoid valve is packed with the control center. The flow control valve and syphon breaker are supplied with all complete disposer packages (packaged separately).
The solenoid valve is supplied with a 24 V coil. Make cer tain that the valves are plumbed according to the water flow direction arrows marked on the valves, or the valves will not function properly.
The flow control valve regulates all water flowing into the disposer. This conserves water and prevents overload ing. Check direction of water flow arrows.
A syphon breaker must be installed above the sink flood plane per local plumbing codes. Check direction of water flow arrows.
ELECTRICAL CONNECTIONS
ELECTRIC SHOCK
• Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that the power is off.
• All installation work must conform to local plumbing and electrical codes.
• All control centers and disposers must be carefully and permanently grounded.
• A properly fused disconnect must be installed at the electrical supply source for the control center.
PROPERTY DAMAGE
• Ensure that control center voltage and phase match the disposer motor and electrical supply. Check name plates on disposer and control centers for voltage and phase specifications.
• Refer to the control center wiring diagrams in this manual for correct connection.
• Use NEMA 4 watertight electrical connectors (not supplied) when making electrical connections to the control center.
All pipe fittings are ½” NPT (National Pipe Taper)
SYPHON BREAKER
FLOW
CONTROL
VALVE
OPTIONAL CONNECTION
DISPOSER
Figure 2. Typical installation diagram
WATER
SOLENOID
VALVE
CONTROL
CENTER
ELECTRICAL DISCONNECT
SWITCH
WATER SUPPLY
ELECTRICAL
SUPPLY
ELECTRICAL CONNECTIONS
The MSLV control center uses low-voltage (24 V) to oper ate contactor coils, push buttons and solenoid valves. Red wires denote the 24 V circuit.
Connect the incoming line power to the electrical door dis connect switch and connect the disposer motor to labeled terminal blocks in the control center. Use the appropriate schematic wiring diagram, Figures 5, 6, 7 or
8. Wiring diagram is also located on the inside door of the control center. Wire the disposer motor for correct voltage using the connection diagram inside the motor terminal box.
Wire per local electrical code using 7/8” diameter holes in the bottom of the control center cabinet, and install NEMA 4 watertight electrical connectors (not supplied). All control centers and disposers must be carefully and permanent ly grounded.
After completing the connections, close door and fasten all locking clamps. Replace disposer motor cover. Turn on power.
WATER SOLENOID VALVE Connect water solenoid valve as shown in Figure 3. Con nect solenoid valve to the low-voltage solenoid terminals numbers 4 and 5.
NOTE: The MSLV control center has a door disconnect switch, the disconnect switch must be in the off position before the panel door can be opened. Power is still pres ent at the disconnect until power is turned off at the supply source.
4 5
WATER SOLENOID VALVE
24 COIL
Figure 3. Solenoid valve connections to control panel terminals.
3