Page 1
The Emerson logo is a trademark and a service mark of Emerson Electric Co.
InSinkErator may make improvements and/or changes in the specifications at any time, in its sole discretion,
without notice or obligation and further reserves the right to change or discontinue models.
©2017 InSinkErator, a business unit of Emerson Electric Co. All Rights Reserved.
InSinkErator HottapTM HC900
Owner’s Manual
Parex Industries Ltd. 5 Tolich Pl. Henderson Auckland, New Zealand 0610 Sales/Service Tel: 0800 200 510 Email: info.parex@emerson.co.nz www.insinkerator.co.nz
45365 Rev A
Page 2
Unpack tap components. On a firm, fl at surface, care fully
straigh ten the cop per tubin g using hands only.
Propert y Damage: Do n ot pinch or break c opper tubing. Do n ot distort th e last 25.4 mm of tubing.
INSTALLING THE TAP
a
HOW TO USE THIS INSTRUCTION MANUAL
These instructions are separated into main se ctions, in dicated by numbers, and subsecti ons, indicated by capital let ters. The manual is setup this way to allow you to take a break at any point after completin g a section or subsection without affecting the install ation process.
What you’ll see in the instruction manual:
1
2
Equipment You May Need:
We are delighted that you have chose n the InSinkErator® Instant Hot Wate r Tap to be a part of your home. Thi s unique appliance will save you time and ef fort in the kitchen, and you’ll enjoy discover ing new uses for it each day. That’s exactly why millions of people are now using an InSinkErator Ins tant Hot Water Tap.
We are confident that by following our step-by-step instructions, you’ll soon be enjoyin g the convenience of instant hot water.
For your satisfaction and safet y, read all instructions, cautions and warnings before installing or using this
instant hot water tap. This particular unit is not intended for commercial use.
Make sure that all electrical wiring and connections conform to local codes. A standard 230-volt grounded electrical outlet is required under the sink for the tank’s electrical power. The wall outlet powering your tank must have power supplied to it continuously. This outlet must be fused and should not be controlled by the same wall switch that operates the disposer,
unless you have a SinkTop Switch™ from InSinkErator®.
Faucet must be installed such that the outlet opening is greater than 25mm above the overflow rim of the sink. It is recommended that a dedicated control valve be installed on the cold water line supplying water to
this system. If you suspect elevated levels of chlorine in your water, or your water has a rusty appearance before the installation
of this unit, it is recommended to use our water filtration system. This product contains stainless steel. The manufacturer cannot guarantee against rust y water because of the
number of factors that are involved beyond the manufacturer’s control. However, the sudden appearance of rusty water discharged from the hot water tap may indicate the need for service or replacement of this product.
The use of a water filter should NOT result in the water pressure to drop below 172 kPa. If it does,
this will prevent your unit from operating properly.
Moving parts inside the tank causing a rattling noise is normal.
WHAT YOU SHOULD KNOW BEFORE YOU BEGIN
Equipment Required:
n Drill n T-fitting n Dedicated control valve n Adjustable wrench
n Phillips and flat blade screwdrivers n Pencil n Tape Measure / Ruler n Level
Anchors for drywall Hole saw
Basin wrench
Hole punch
If you intend to use the sprayer hole in your sink for your tap, you may need a basin wrench and a
3.2mm plug or a 6.4mm cap (not supplied) for the faucet spray hose line. See Step 1-B.
If you need to cut a mounting hole in your stainless steel sink, you may need a 32mm- 38mm hole saw made for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than stainless steel.
WHAT YOU NEED TO GET STARTED
3
2
Provides a step-by-step narrative describing the installation step, with check boxes that can be marked as you progress through the installation.
Contains simple illustrations that provide visual instruction to support the narrative.
Important safety messages that will require your attention during the step.
1
2
3
Warning indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
Caution indicates a ha zardous situation which, if not avoided, could result in minor or moderate injury.
Notice is used to address practices not related to personal injury.
NOTICE
NOTICE
NOTICE
3
COMPONENTS IN THIS PACKAGE
1/4" Tube
Brass Nut /Ferrule /
Tube Insert
Quick Connector
3/4" Screws (2)
Extension & Star Nut*
1/4" Tube
Brass Nut /Ferrule /
Tube Insert
Quick Connector
3/4" Screws (2)
Extension & Star Nut*
Small Steel*
FiberRubber* Large Steel
Washers
1-1/2 "
1-1/4" 1-1/4"
1-5/16 "
*component parts pre-installed on tap
32mm32mm
HC-View-SS
H-View-SS
HC-Wave-SS
1/4" Tube
Brass Nut / Ferrule /
Tube Insert
Quick Connector
3/4" Screws (2)
Extension & Star Nut*
Small Steel*
FiberRubber* Large Steel
Washers
1-1/2"
1-1/4" 1-1/4"
1-5 /16"
3/4" Screws (2)
Extension & Star Nut*
HC900
1/4" Tube
Brass Nut /Ferrule /
Tube Insert
Quick Connector
Fiber
Large Steel
1-1/2 "
1-5/16 "
Tank
33mm 38mm
Page 3
The wall outlet for your tank must have power supplied to it continuously
and must be fused. It should not be controlled by the same wall switch
that operates your disposer, unless using an InSinkErator SinkTop Switch™.
PREPARATION
START HERE
Identify locations for the tap faucet,
tank and filter ( if applicable).
Check to make sure there is proper
clearance for tap handles to be fully opened.
Check to make sure counter
is not too thick.
Make sure there is a grounded
electrical outlet under the sink.
Turn off water supply. If using the sink sprayer hose hole,
remove nut that connects sprayer hose at bottom of faucet.
Using adjustable wrench, remove nut
connecting sprayer washer flange in sprayer hole.
Plug hose opening with either a
3.2mm plug or a 6.4mm cap
(not supplied).
a
b
If yo u have to drill through sink or
counter top, you may need to rent or
purchase the appropriate tools.
Consult a professional before drilling into
a surface o ther than stainless steel.
C
What if you don’t have a sprayer hole or don’t want to use it?
Many homeowners replace the
soap dispenser in their sink with an instant hot water tap.
If drilling a hole into a stainless steel
sink or counter top, you can cut a mounting hole for the tap with a hole saw for stainless steel, or you can use a hole punch.
Required Hole Size
32mm- 38mm
Dependent on model
Required minimum from
center of hole to wall
67mm
Maximum counter
thickness (depth)
76mm
1
5
4
OVERVIEW OF A COMPLETED SETUP
Page 4
Unpack tap components. On a firm, flat surface, carefully
straighten the copper tubing using hands only.
Unscrew a nd remove threaded extension
from valve body. Do not disca rd, as you will need this later (See Figure 1).
Leave small wa shers in place.
Feed tubes down through the hole in
the sink/counter until the base is at rest. Set fau cet at desired angle.
From under sink, slide 38mm fiber
washer over faucet base. Reinstall threaded ex tension onto the base until snug. Threa d star nut onto extension until snug ( See Figure 2).
From under sink, slide 38mm fiber washer
over threaded extension. T hread sta r nut onto extension until snug.
Attach the quick connector to the
ends of the copper tubes r unning from the tap.
Install a whit e 9.5mm tube into oth er end
of quick connector.
If sink/ counter t hickness exceeds 19mm
a hole diameter of 38m m is required.
An assist ant may be needed to hold
the tap head in p lace
while securing the tap.
2
For a stand ard 38mm sink/counter hole
Feed tubes down through the hole in
the sink/counter until the base is at rest. Set fau cet at desired angle.
Large washer r equired f or sink hole s
larger than 38mm or for porcelain sinks with radius or beveled holes .
Before feeding tubes through sink
hole, remove extension. Place 33mm large steel wa sher over threads on faucet base. Reinstall extension.
Tap is factory-ready for in stallat ion
into a stan dard 38mm sink/counter hole.
32mm Small Steel
Washer
Fiber
Washer
Star Nut
33mm Large Steel Washer
32mm
Small Rubber Washer
Standa rd 38mm hole Hole larger than 38mm
Installing into hole smaller than 38mm
Figure 1 Figure 2
Property Damage: Do not pinch or break copper
tubing. Do no t distor t the last 2 5mm of tubing.
32mm Small
Steel Washer
Fiber
Washer
Star Nut
32mm Small
Rubber Washer
32mm Small
Steel
Washer
32mm
Small Rubber Washer
INSTALLING THE TAP
a
C
b
NOTICE
6
7
(1)(2) (3)
Selec t a spot under the sink to mount
tank vertically within reach of both plumbing and electrical connections. The tank should be within 400mm or less of faucet water lines and within 760mm or less of a standard grounded outlet.
While holding tank in place on
the spot sele cted for installation, use a pencil to mark locations for 2 hanging screws.
Property Damage: Tank must be located
within 400mm of f aucet and wi thin 760mm
or less of a standa rd grounded outlet . DO NOT
extend plumbing or electrical lines.
3
Without depressing the gray button,
place the snap-connect fitting at the end of the blue 6.4mm tube onto the left fitting on the tank, pushing until it clicks into place. (1)
Slip the flexible white 11mm tube
over barbed middle fitting and slide down approximately 12mm. (2)
Slip the clear 8mm tube over
the far right smooth fitting and slide down approximately 12mm. (3)
Visually check for pinched or
crimped tubes.
4
Property Damage: Pinche d or blocked water
lines may cause d amage to the t ank.
Check to make sure tubes are connecte d
properly a nd are pushe d down as far a s possible.
Tank must be mounted level
to ensure
proper operation.
Hose clamps are not needed for any
of the connections.
Mount tank vertically in an area t hat allows clear ance on the u ndersid e of
the tank fo r drainage, if necessa ry.
DO NOT over t ighten s crews.
Pre-drill 3.2mm pilot holes at marks. Turn screws into pre-drilled holes,
leaving 6.4mm exposed.
Hang the tank on the screws. Tighten the screws with only 1/2
turn clockwise.
Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall.
Leave 6.4mm for
hanging tank.
Brass Nut
Ferrule
Brass Insert
Brass Nut
Ferrule
MOUNTING THE TANK
CONNECTING TAP TO TANK
a
a
b
NOTICE
NOTICE
Page 5
9
8
Scalding Hazard: The faucet dispenses
near-boiling ( 96ºC) water w hich can
instantly cause scalds or burns. Use care
when operating this appliance.
Property Damage: Join r emaining tub e
to cold water supply only.
Turn on the cold water supply. Depress the tap HOT han dle and hold
it until water flows from the spout (approximately 1 to 2 minute s).
Run the water for at least 2 minutes to
flush lines (both the hot and cold han dles independently if applicable).
6
Check all connections to ensure they are
tight and that there are no leaks.
Plug in inst ant hot water ta nk.
Water will be cold at first.
Allow 12-15 minutes for water to reach target temperature.
Gurgling or hissing is normal during the initial heating cycle.
5
Electric Shock Hazard: A standard grounded
outlet wit hin 760mm of the tank
is required under the sink . Do not use
an extensi on cord set with the tank.
FINAL WATER CONNECTION
FILL TANK & THEN CONNECT POWER
b
a
a
NOTICE
NOTICE
Electric Shock Hazard: Using an ungrounded or improperly connected appliance can result in serious injur y or death from electrical shock.
Property Damage: To avoid water damage, replace any loose or split tubing. Periodically inspect the unit for any signs of leakage and immediately remove from service any unit suspected of leaking.
Personal I njury : This tank is a non-pressurized tank. DO NOT modify this system. DO NOT close vent tube or connect other type tap or valves to the tank. Use only the InSinkErator tap supplied. U se only parts provided. Contact an authorized InSinkErator Service agent for repairs or replacement components.
This appliance must be grounded. This instant hot water tank is equipped with a cord that has a grounding conductor and a grounding pin. The plug must be connected to an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Check with a qualified electrician or serviceman if you are in doubt a s to whether the instant hot water tank is properly grounded.
Fire Hazar d: To minimize possibilit y of fire, DO NOT store flammable items such as rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Leak Hazard: Regularly inspect tap and plumbing fit tings for leaks, which can cause propert y damage and /or could result in personal injury.
An instant hot water tank, like a ny water heater, has a limite d life and will eventually fail. To avoid possible property damage a nd personal injury, this in stant hot wate r tank should be regularly examined for leakage and/or corrosion and replaced when necessary. A drain pan, plumbed to an appropriate dr ain or out fitte d with a leak d etector, should be used in those applications wher e any leakage could cause pr operty dama ge. To check for co rrosio n, exam­ine the app earan ce of the dis pense d water in a cle ar glas s once ever y thre e (3) months. If there is any discoloration or r usty appeara nce, unplug and drain unit as descri bed in the Season al Storage/D raina ge section on page 11 of this manual. If the water d iscoloration remain s after drainin g and refi lling unit, discontinue use a nd contact an authorized InSinkErator service agent.
NOTICE
NOTICE
NOTICE
NOTICE
IMPORTANT SAFETY INSTRUCTIONS
See instructions provided with valve kit
At the other end of the white tube from the filter, press on the:
n 9.5mm (3/8") to 1/4" BSPT fitting
or 9.5mm (3/8") to 1/2" BSPP fitting and connect to the water supply.
n Press in again to ensure a secure fit.
Back flow
protection valve
Wall mount clip
Page 6
11
10
IN-HOME FULL SERVICE LIMITED WARRANTY
Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit . Use only a properly grounded and polarized electric outlet.
Scalding Hazard: Do not all ow water to boil. M ay result in severe burns.
Factory temperature inside the tank is pre-set at 96˚C.
Adjust the up or down arrows on the display panel on front of the tank to raise or lower the water temperature. After adjusting, depress the tap handle for 20 second s for water to re-heat to the new setting.
Regularl y inspect the unit for any signs of leakage. If there are signs of water damage, immediately remove the unit from service.
A drain pan, plumbed to an appropriate drain or out fitted with a leak detector, should be used in those applications where any leakage could cause property damage.
PROPERTY DAMAGE
CARE AND USE
Only use mild clea ners to clean the
faucet and plastic components.
Cleaners w ith acids, abrasives, a lkaline
or organic solvents will re sult in deterioration of the plastic components and void the warranty.
CLEANING THE TAP AND TANK
Anytime the instant hot water tap is not used for extended periods of time, unplug and drain unit. If it is below freezing you will need to unplug the unit and drain it.
SEASONAL STORAGE/DRAINAGE
ADJUSTING THE THERMOSTAT
Regularly check for signs of corrosion by examining the appearance of the dispense d water.
If there is any dis colorati on or rust y appearance, unplug a nd drain unit as described in the Seasonal Storage /Drainage section on this page of the manu al.
If the water discoloration remains after draining and refilling unit, discontinu e use and contact an authorized InSinkErator service agent.
PERSONAL INJURY
Disconnect power from unit (unplug unit).
Push hot water tap fau cet lever and allow water to flow until it is cool.
Shut the cold wa ter supply of f at the valve.
Disconne ct tubes fr om the tank.
Unhook tank from wall.
Hold tank upside down and drain the water into the sink.
Towel dry any water drippings from tank area.
Reinstall tank to wall and re connect tubes.
Remove and disc ard filter c artridge, if applicable.
To put back into working or der, install new filter car tridge (if applicable) a nd turn on cold water supply at valve. Depress the hot water tap faucet lever and hold until wa ter flows from the spout. Reconnect the electrical cord. (Refer to Page 8, Step 6B )
NOTICE
NOTICE
This limited warranty is provided by InSinkErator, a business unit of Emerson Electric Co., (“InSinkErator” or “Manufacturer” or “we” or “our” or “us”) to the original consumer owner of the InSinkErator product with which this limited warranty is provided (the “InSinkErator Product”), and any subsequent owner of the residence in which the InSinkErator Product was originally installed (“Customer” or “you”
or “your”). InSinkErator warrants to Customer that your InSinkErator Product will be free from defects in materials and workmanship, subject to the
exclusions described below, for the “Warranty Period”, commencing on the later of: (a) the date your InSinkErator Product is originally installed, (b) the date of purchase, or (c) the date of manufacture as identified by your InSinkErator Product serial number. You will be required to show written documentation supporting (a) or (b). If you are unable to provide documentation supporting either (a) or (b), the Warranty Period commencement date will be determined by Manufacturer, in its sole and absolute discretion, based upon your InSinkErator Product serial number.
Permitted Uses
You may use your InSinkErator Product hot/cold water tank and filter system in combination with any genuine InSinkErator Product instant hot water taps and component parts and/or Authorized OEM Products. “Authorized OEM Products” mean those hot or hot/cold water taps and component parts that have been manufactured by an authorized InSinkErator original equipment manufacturer (“Authorized OEM”) and which have documentation expressly stating that such Authorized OEM Products are compatible with the InSinkErator Product(s). Authorized OEMs may change from time to time. A list of Authorized OEMs is available to you upon request or at: www.insinkerator.com/ oem. Use of your InSinkErator Product in combination with any products other than Authorized OEM Products will void this warranty.
What is Covered
This limited warranty covers defects in materials or workmanship, subject to the exclusions below, in InSinkErator Products used by a consumer Customer for residential use only, and includes all replacement parts and labor costs. YOUR SOLE AND EXCLUSIVE REMEDY
UNDER THIS LIMITED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE INSINKERATOR PRODUCT, PROVIDED THAT IF WE DETERMINE IN OUR SOLE DISCRETION THAT NEITHER REMEDY IS PRACTICABLE, WE MAY PROVIDE YOU A REFUND OF YOUR PURCHASE PRICE OR A CREDIT TOWARDS ANOTHER INSINKERATOR PRODUCT.
What is not Covered
This limited warranty does not extend to and expressly excludes:
• Losses or damages or the inability to operate your InSinkErator Product resulting from conditions beyond the Manufacturer’s control including, without limitation, accident, alteration, misuse, abuse, neglect, negligence (other than Manufacturer’s), failure to install, maintain, assemble, or mount the InSinkErator Product in accordance with Manufacturer’s instructions or local electrical and plumbing codes.
• Wear and tear expected to occur during the normal course of use, including without limitation, cosmetic rust, scratches, dents or comparable and reasonably expected losses or damages.
• Losses or damages caused by any product or component part used with the InSinkErator Products, including both Authorized OEM Products and other products and components.
In addition to the above exclusions, this warranty does not apply to InSinkErator Products installed in a commercial or industrial application.
No Other Express Warranty Applies
This limited warranty is the sole and exclusive warranty provided to the Customer identified above. No other express warranty, written or verbal, applies. No employee, agent, dealer, or other person is authorized to alter this limited warranty or make any other warranty on behalf of Manufacturer. The terms of this limited warranty shall not be modified by the Manufacturer, the original owner, or their respective successors or assigns.
What we will do to Correct Problems
If your InSinkErator Product does not operate in accordance with the documentation provided to you, or you have questions concernin g your InSinkErator Product or how to determine when service is needed, please call, toll free, 0800-200-510, or visit our website at www.insinkerator.co.nz. You may also notify us at: Parex Industries Ltd., 5 Tolich Pl. Henderson, Auckland, New Zealand 0610
The following information must be provided as part of your warranty claim: your name, address, phone number, your InSinkErator Product model and serial number, and if necessary, upon request, written confirmation of either: (a) the date shown on your installation receipt, or (b) the date shown on your purchase receipt.
Manufacturer or its authorized service representative will determine, in its sole and absolute discretion, if your InSinkErator Product is covered under this warranty. You will be given the contact information for your closest authorized InSinkErator Service Center. Please contact your InSinkErator Service Center directly to receive in home warranty repair or replacement service. Only an authorized InSinkErator service representative may provide warranty service. InSinkErator is not responsible for warranty claims arising from work performed on your InSinkErator Product by anyone other than an authorized InSinkErator service representative.
If a covered claim is made during the Warranty Period, Manufacturer will, through its authorized service representative, either repair or replace your InSinkErator Product. Cost of replacement parts or a new InSinkErator Product, and cost of labor for repair or installation of the replacement InSinkErator Product are provided at no cost to you. Repair or replacement shall be determined by Manufacturer or its authorized service representative in their sole discretion. All repair and replacement services will be provided to you at your home. If Manufacturer determines that your InSinkErator Product must be replaced rather than repaired, the warranty on the replacement InSinkErator Product will be limited to the unexpired term remaining in the original Warranty Period.
This instant hot water tap is covered by Manufacturer’s limited warranty. This limited warranty is void if you attempt to repair the InSinkErator Product. For service information, please visit www.insinkerator.co.nz or call, toll free, 0800-200-510.
Limitation of Liability
TO THE EXTENT PERMITTED BY LAW, IN NO EVENT SHALL MANUFACTURER OR ITS AUTHORIZED SERVICE REPRESENTATIVES BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE INSINKERATOR PRODUCT OR THE MANUFACTURER’S OR ITS AUTHORIZED SERVICE REPRESENTATIVE’S NEGLIGENCE. MANUFACTURER SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL MANUFACTURER’S LIABILITY TO YOU EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE INSINKERATOR PRODUCT.
The term “consequential damages” shall include, but not be limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss or damage to property or equipment.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state.
2-year warranty
Page 7
12
TROUBLESHOOTING
WHAT TO DO
Water and steam spits forcefully from spout without turning on the tap faucet.
Water is not hot.
• Unit is boiling.
May be normal during initial setup.
• The unit is unplugged.
• The electric outlet is inoperative.
• Activate faucet lever to release s ome water from the tank.
• Adjust water temper ature using dial on tank front.
Remember that at higher altitudes, water boils at lower temperatures.
• Make sure the unit is connected to a properly grounded electric outlet.
• Make sure the circuit breaker or fuses are functioning properly.
• Check that the outlet is not switched off.
Water is too hot or not hot enough.
• Thermostat is not adjusted to your needs.
• Adjust the thermostat slowly, then activate faucet lever for 20 seconds to bring in fresh water to be heated at the new setting. Allow 5-7 minutes for water to reach new temperature.
Water comes out the vent instead of spout.
• Outlet tube is blocked. • Check that outlet tube is not kinked, t wisted or pinched.
• Unscrew spout end piece and clean out any debris.
Water is dripping from the spout /vent intermittently.
• The expansion chamber isn’t
draining properly due to low water pressure.
• The spout is blocked.
• Unplug the unit. If the dripping doesn’t stop after a few minutes, check the supply valve to ensure that is fully open and there are no obstructions in the water line reducing the pressure below 172 kPa (i.e., a poorly mounted saddle valve, a clogged
water filter, or a partially opened shut-off valve).
• Unscrew spout end piece and clean out any debris.
Water is dripping from the spout /vent constantly.
• Debris in the water line may be in the faucet valve seat causing a slow water leak.
• Unscrew spout end piece and clean out any debris.
• Activate faucet lever 7-10 times to flush faucet & lines.
Divided stream.
• Debris in the end piece. • Unscrew spout end piece and clean out any debris.
Water continues to run after releasing lever.
• Mounting nut too tight.
• Mounting washer s not installed properly
• Loosen mounting nut, 1/4 turn at a time, until shut-off occurs.
• See page 6, Step 2B to check proper mounting washer installation.
PROBLEM POSSIBLE CAUSE
Please read Troubleshooting Guide
Water discoloration/ rusty appearance.
• Corrosion of unit. • Unplug and drain unit as described in the S easonal Storage /Drainage Section on page 11 of this manual. If the water discoloration remains after draining and refilling unit, discontinue use and contact an authorized InSinkErator service agent.
Loading...