Instant Hot Water Dispensers
Model
F-601R
The Next
Necessity
* Tested using a flow rate of 1.00 gpm;
pressure of 60 psi; pH of 7.5 ± 0.5;
temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles
used were 0.5 - 1 microns
Base on the use of Cryptosporium parvum
*
cyst. Do NOT use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection
before or after the system. Systems
certified for cyst reduction may be used
on disinfected waters that may contain
filterable cysts. EPA Establishment #:
070595-CT-001
Job Specifications
Replacement Filter Plus
™
Submittal Sheet Specifications
• Includes 2 replacement filters for use with
InSinkErator water filtration system
• Reduces sediment, chlorine taste and odor,
Plus cysts, lead, mercury, asbestos, benzene,
atrazine, 2,4-D and other chemicals for
healthier, safer water
• Sanitary, quick-change filter cartridge
makes replacement easy. A simple twist
is all it takes!
• 6 month recommended filter
cartridge replacement
F-601R Chemical & Mechanical Reduction Filter Specifications: This cartridge provides mechanical and chemical
reduction of dirt/rust, chlorine/taste/odor, particulates, cysts, asbestos, lead, mercury, lindane, benzene, carbofuran,
p-dichlorobenzene, 2,4-D and Atrazine.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standards 42 and 53.
Tested and Ce rtifi ed by NSF Inte rnation al agains t NSF/ANS I Standa rd 42 and 53 fo r use in the
F-201 system f or the redu ction of Chl orine ta ste and odo r, Nominal Par ticulat e Class I, cy sts,
asbestos, lead, mercury, lindane, benzene, carbofuran, p-dichlorobenzene, 2,4-D and Atrazine.
Filter Capacity: 500 gallons, depending on local water conditions. Note that while the testing was performed under
standard laboratory conditions, actual performance may vary. For cold water use only. Systems must be installed and
operated in accordance with the Manufacturer’s recommended procedures and guidelines. See warranty card for warranty.
For service and parts, contact your local dealer or InSinkErator
Substance USEPA MCL
Nominal Particulate*
Substance
Cysts
Asbestos
Lead @ pH 6.5
Lead @ pH 8.5
Mercury @ pH 6.5
Mercury @ pH 8.5
Lindane
Benzene
Carbofuran
p-dichlorobenzene
2,4-D
Atrazine
NSF is a trademark of NSF International.
Application guidelines/Water Supply Parameters for NSF Testing: Service flow of 1.0 gpm, community or private well water supply,
water pressure of 20-125 psi, water temperature of 33˚F–100˚F. Except as noted, all testing performed at pH = 7.5 ± 0.5, Flow: 1.0 gpm,
Pressure: 60 psi, Temp: 20˚± 3˚C.
USEPA MCL
99.95% redu ction
99% reduc tion
0.015 m g/L
0.015 m g/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.005 mg /L
0.04 mg/ L
0.075 mg/ L
0.07 mg/ L
0.003 mg /L
Influent Challenge concentration
~
at least 10,000 particales/mL
Influent Challenge concentration
fibers gr eater than 10 µm in lengt h
(mg/L)
2.0m g/L +10 %
(mg/L)
Minimum 50,000 #L
7
10
to 108 fibers/L;
0.15 +10%
0.15 +10%
0.00 6 ±10%
0.00 6 ±10%
0.00 2 +10%
0.015 ±1 0%
0.08 ± 10%
0.22 5 ±10%
0.210 ±10 %
0.00 9 ±10%
Contact an authorized InSinkErator service agent for repairs or replacement components.
REPLACEMENT ELEMENT
Standard 42: Aesthetic Effects
Effluent
Average
2.12 mg/ L 0.05 mg/ L~Chlorine Taste & O dor
10,566,667 #/ml 171,8 33 #/ ml 360,000 #/ml 97. 88%
Standard 53: Health Effects
Influent
Average
127,000 #L
0.15 8 mg /L
0.15 4 mg /L
0.006 mg /L
0.006 mg /L
0.002 mg/L
0.014 mg/ L
0.080 mg /L
0.240 m g/L
0.19 0 mg /L
0.009 mg /L
<0.00002 mg/L
Filter Capacity
Temperature
Range
500 gallons
Incoming cold water supply
line can be from 33˚F to
100˚F (1˚C to 38˚C).
Connect to cold water
supply line only.
Pressure
Flow Rate
Shipping Weight
Dimensions
®
directly at 1-800-558-5700.
Effluent
Average Maximum Average Maximum
Average Ma ximum Average Maximum
<1 MF/L140 MF/L
<0.001 mg /L
<0.001 mg /L
0.000 mg/L
0.000 mg/L
<0.005 m g/L
1.06 3 mg/ L
0.525 mg/ L
0.012 m g/L
0.0005 mg/L
0.05 mg/ L 97. 66% 97.6 2%
1 #L
<1 MF/L
<0.001 mg /L
<0.001 mg /L
0.000 mg/L
0.000 mg/L
<0.00002 mg/L
0.005 mg /L
0.002 mg/L
0.800 mg /L
0.071 mg /L
0.0005 mg/L
1 #L >99.99%
20-125 psi
1.0 gpm
Approximately 2.5 lbs.
10-2/3"H installed, 3-1/4"W
% Reduct ion
95 .10%
% Reduct ionEffluent
>99.99%
99.72%
99.81%
99.37%
99.37%
99.33%
99.34%
89.26%
94.35%
67.15 %
85.27%
98.98%
99.03%
96.05%
96.32%
97.33%
98 .74%
99.64%
99.76%
62.63%
93.84%
94.48%
94.77%
Pressure: 20 -125 psi
Temperature: 33-100°F
Flow rate: 1.0 gpm
Capacity: 500 gallons
Min. Required
Reduction
>50%
>85%
Min. Required
Reduction
>99.95%
>99%
0.010 m g/L
0.010 m g/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.005 mg /L
0.04 mg/ L
0.075 mg/ L
0.07 mg/ L
0.003 mg /L
NSF
Report
J-00029741
J-00029739
NSF
Report
J-00031000
J-00029743
J-00031399
J-00029746
J-00029747
J-00029748
J-00029753
J-00029751
J-00029750
J-00029749
J-00029754
J-00029752
USA
1-800-558-5700
www.insinkerator.com
Canada
1-800-561-1700
www.insinkerator.ca
HWD427-12F-45-12 Printed in USA
The Emerson logo is a trademark
and a service mark of Emerson Electric Co.
InSinkErator may make improvements and/or changes
in the specifications at any time, in its sole discretion,
without notice or obligation and further reserves the
right to change or discontinue models.
©2012 InSinkErator, a business unit of
Emerson Electric Co. All Rights Reserved.