Instant HOT
Water Filtration
System
Installation Instructions
Sistema
de filtración de
agua CALIENTE
Instrucciones de instalación
Système de
filtration d’eau
CHAUDE instantanée
Instructions d’installation
1.800.558.5700
www.insinkerator.com
444 64 REV A
The Eme rson logo is a trademark an d service ma rk of Emerson Electric Co. Printed in U. S.A.
El logot ipo de Emerso n es una marca registrada y una marca de s ervicio de Em erson Elect ric Co. Impre so en los EE.U U.
© 2012 I nSinkErator, InSi nkErator® es una u nidad de neg ocio de Emer son Electric Co. Todos los de rechos reser vados.
Le logo E merson est u ne marque de commerce et un e marque de se rvice de Emer son Electri c Co. Imprimé aux É.-U.
© 2012 I nSinkErator, InSi nkErator® is a bu siness unit of Emerson Elec tric Co. All R ights Reser ved.
© 2012 I nSinkErator, InSi nkErator® est un e unité commerc iale d’Emer son Electric Co. Tous droits r éservés.
INTRODUCTION
OVERVIEW OF A COMPLETED SETUP
Read, understand, and follow all safety information contained in these instructions
prior to installation and use of the InSinkErator
System. Retain these instructions for future reference.
The InSinkErator Instant Hot Water Dispenser Filtration System is intended for use
in filtering sediment, chlorine taste and odor from drinking water, and has not been
evaluated for other uses. The system is typically installed (near or beneath a sink)
where filtered drinking water is desired, and must be installed, operated and
maintained as specified in the installation and use instructions.
A potentially hazardous situation, which, if not avoided, could result in death or serious injury.
Caution, used with the safety alert symbol, indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
Caution, without the safety alert symbol, is used to address practices not related to
personal injury.
®
Instant Hot Water Dispenser Filtration
COMPONENTS IN THIS PACKAGE
Filter Head and Bracket
A
F-201R Filter Cartridge
B
Two Polyethylene Tubes
C
“Y” Quick-Connector
D
Ferrule
E
Tube Insert
F
To reduce the risk associated with property damage due to water leakage:
• Protect filter from freezing. Drain filter when temperatures drop below
40°F (4.4°C).
• Do not install if water pressure exceeds 120 psi (828 kPa). If your water
pressure exceeds 120 psi, you must install a pressure limiting valve.
Contact a plumbing professional if you are uncertain how to check your
water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a
plumbing professional if you are uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100°F (38°C).
• The disposable filter cartridge must be replaced every six months or at the
specified service cycle.
• Read and follow instructions before installation and use of this system.
Brass Nut
G
2
To reduce the risk associated with ingestion of contaminates due to use with
water that is microbiologically unsafe or of unknown quality, do not use with
water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
3
F-201R Ca rtr idg e (in cluded wi th th is sys tem ) Chem ical & Mech anical Re duct ion Filte r Spec ificati ons :
Turn off water supply before starting.
Installation must comply with all state and local laws and regulations.
INSTALLING FILTRATION SYSTEM
1
a
Personal Injury: Do not locate filter above an
outlet or other electrical device. Install head and
bracket so that connections require no stretching,
kinking or pinching of tubing.
b
from water
supply line
Property Damage : Tube runs need to form to the
cabinet’s contours to allow storage space with no
sharp bends. Tubes need clean, perpendicular,
burr-free cuts to ensure a true fit.
to dispenser
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" starter holes and attach
bracket to wall with wood screws,
turning until snug.
Remove red filter cap, insert filter
cartridge into filter head and twist
clockwise until “LOCK” arrow on the
filter aligns with arrow on bracket.
Determine length of tubing required,
then cut to length making sure the cut
is perpendicular and burr-free.
Insert a white 3/8" tube into inlet side
of filter head until it stops. Press in
again to ensure a secure fit.
Insert the other white 3/8" tube into
outlet side of filter head until it stops.
Press in again to ensure a secure fit.
FINAL WATER CONNECTION
2
Brass Nut
a
3/8"
Plastic
Tube
Ferrule
Brass
Insert
Property Damage : Join remaining tube
to cold water supply only.
Install a T-fitting (not included)
onto the cold water supply line.
Install dedicated water control valve
with 3/8" compression fitting.
At the end of the white 3/8" tube
from the filter or quick-connector,
slide the supplied brass nut and
ferrule over the tube and then push
in the brass tube insert.
Insert the white 3/8" tube into the 3/8"
compression fitting and tighten.
TURN ON WATER & CONNECT POWER
3
a
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Turn on the water supply.
Depress the dispenser’s HOT handle
and hold it until water flows from the
spout (approximately 1 to 2 minutes).
For the F-201 and F-201R, flush 2.25
gallons through filter before use
(approximately 3 minutes). For the
F-601R, flush 3 gallons through filter
before use (approximately 3 minutes).
Check all connections to ensure they
are tight and that there are no leaks.
HC1100, HC2200,
c
d
HC2215
From filter or
water supply line
Property Damage : Do not extend the lines far ther
than the 16" provided. Ensure tube(s) and “Y”
connnector are securely fit.
Discharge tube
From water
supply line
It is normal for approximately 2 oz. of water
to discharge when filter is removed.
GN1100, GN2200, GN2215,
HC33 00, H3300
Plug
From filter or
water supply line
To dispenser
Insert the copper tube(s) from the
dispenser into “Y” quick-connector
using the plug for hot-only models.
Connect the white 3/8" tube from the
right outlet on the filter head into the
quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
To redirect filter replacement water
discharge, place 6" clear tube over
vent hole on the left side of filter head.
Note: 3/8" fitting is required to make
connection to water supply.
Connect remaining white 3/8" tube to
incoming water supply line. (See Step 2.)
4
This cartridge provides mechanical and chemical reduction of dirt/rust, taste/odor and chlorine.
Tested and Certified by NSF International against
NSF/ANSI Standard 42 in model F-201 for the redu ction
of claims specified on the Performance Data Sheet.
Filter Capacit y: 50 0 gallons, depending on local water conditions. Note that while the testing was performed under
standard laborator y conditions, actual performance may vary. Do not use with water that is microbiologicall y unsafe or
of unknown quality without adequate disinfection before or after the system. For cold water use only. Systems must be
installed and operated in accordance with the Manufacturer’s recommended procedures and guidelines. See warranty
card for warranty. For ser vice and par ts, contact your local dealer or InSinkErator
Appl ica tion guidelin es/ Water Sup ply Pa ram eters for NS F Testing: Service flow of 0.75 gpm, community or
private well water supply, water pressure of 20-120 psi, water temperature of 33°F–100°F. Except as noted, all
testing performed at pH = 7.5 ± 0.5, Flow: 0.75 gpm, Pressure: 60 psi, Temp: 20°±3°C.
Cont act an a uth oriz ed InS inkErat or ser vice agent for repai rs or repla ceme nt compon ents.
Press ure: 20-120 ps i
Tempera ture: 33º - 10 0ºF
Flow Rate : 0.75 gpm
ty: 5 00 gallons
Capaci
®
directly at 1-80 0-558-570 0.
5