Insinkerator CC-101K-5 User Manual

PROJECT: ITEM NO.:
CONTROL CENTER MODEL CC-101
WATER/ENERGY SAVING FEATURE • AUTOMATIC REVERSING ACTION
SPECIFICATIONS
STAINLESS STEEL ENCLOSURE
• NEMA 4
• Stainless steel construction
• Easy to clean and keep clean AUTOMATIC REVERSING CONTROL
• Reverses direction of motor at each startup
• Increases cutting element life and reduces jams REVERSING DELAY
• Protects motor from burn out from operator misuse AUTOMATIC DROP OUT SYSTEM
• If a power loss occurs, control will automatically disengage power lines
• Disposer must be restarted DISCONNECT SWITCH
• Disconnects electrical power beyond switch for service
• Interlock with front cover SOLID STATE CONTROL
• Operates on 24V SOLID STATE CONTROL CIRCUIT
• Printed circuit board with control diagnostic/function lights, delay timers and timed run pin and reversing control
POST WATER FLUSH
• Adjustable timer allows water to run automatically for up to 10 minutes, flushing disposer and drain lines after disposer is shut off
TIMED RUN OR CONTINUOUS RUN
• Selected at your discretion, simply by moving the plug-in in on the printed circuit board
• Timed run shuts off disposer automatically after 10 minutes
• Can be shut off manually any time SO L ENOID VALVE
• Packed unattached inside control center carton
• Ensures that water is flowing into disposer while disposer is operating
VOLTAGE/PHASE AVAILABILITY
DIMENSIONS
9-7/8"
(250.8 mm)
8-1/4"
(209.6 mm)
(384.2 mm)
14"
(355.6 mm)
15-1 /8"
15-3/4"
(400.1 mm)
1"
(25.4 mm)
Model Voltage/Hz Phase Disposer Models
CC101K- 5 120V, 50/60 Hz 1 Ph SS-50 to SS-200
CC101K- 6 208-240V, 50/60 Hz 1 Ph SS-50 to SS-200
CC101K-7 208-240V, 50/60 Hz 3 Ph SS-50 to SS-1000
CC101K- 8 380-460V, 50/60 Hz 3 Ph SS-50 to SS-1000
4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620
www.insinkerator.com
InSinkErator is a business unit of Emerson Electric Co.
A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com.
The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.
InSinkErator ©2014 Printed in USA Form No. F455-14K-89-85
5-5/16"
(134.9 mm)
6-3/4"
(171.5 mm)
RECOMMENDED INSTALLATION
NOTE: The CC-101 control center should be mounted 1-1/2" (38.1 mm) back from the front surface of the table.
Loading...