Architect’s User’s Owner’s Guide
Vers.1.2
Note:
Company Sumetzberger reserves the right to do modifications on their products, which serve the technical development of the products. These modifications are not necessarily recorded in each particular case. This documentation and the contained information are recorded and arranged with the necessary diligence, but company Sumetzberger takes no guarantee for printing errors or other faults or resulting damages. The brand and products named in this documentation are trademarks or registered trademarks of the particular title holder.
Ing Sumetzberger GmbH
Leberstraße 108
A-1110 Vienna
Telephone |
+43.(0)1.74035 |
0 |
Fax |
+43.(0)1.74035 |
300 |
E-mail (Technical support) |
pt.technics@sumetzberger.at |
|
E-mail (Sales) |
pt.sales@sumetzberger.at |
|
Homepage |
www.sumetzberger.com |
© Copyright 2011 Ing Sumetzberger GmbH
CONTENTS
1 |
Data sheets |
|
|
RFID 2000 ................................................................................................ |
1 |
|
Code Tag.................................................................................................. |
2 |
|
Antenna 110 ............................................................................................. |
3 |
|
Antenna 160 ............................................................................................. |
4 |
2 |
Installation |
|
|
RFID2000 ................................................................................................. |
5 |
|
Antenna ................................................................................................... |
6 |
|
Carrier 160 ............................................................................................... |
7 |
|
Flip top carrier 110.................................................................................... |
8 |
|
Application examples of RFID2000 units ..................................................... |
9 |
3 |
Cabling |
|
|
General-System cable................................................................................ |
10 |
|
Power supply with filter modul ................................................................... |
11 |
|
SCB2000 with RFID and 1 Antenna............................................................. |
12 |
|
SCB2000 with RFID and 3 Antenna............................................................. |
13 |
4EU-Conformity Declaration
5FCC-Registration
|
FCC Statement.......................................................................................... |
15 |
|
FCC Confidentiality Request ....................................................................... |
16 |
6 |
User Instruction Manual |
|
|
General Safety Instructions........................................................................ |
17 |
|
Label for devices ....................................................................................... |
18 |
|
General .................................................................................................... |
19 |
|
Keyboard.................................................................................................. |
20 |
|
User numbers ........................................................................................... |
20 |
|
Making a transit ........................................................................................ |
21 |
|
Arrival Signal ............................................................................................ |
22 |
|
Special Codes ........................................................................................... |
23 |
|
Security.................................................................................................... |
24 |
|
DCU Instruction Special Codes ................................................................... |
25 |
Data sheets 1 - 1
8.3.11 RFID 2000 Vers.1.2
Model |
RFID 2000 |
|
|
|
|
|
|
Manufacturer |
Sumetzberger GmbH |
|
|
|
|
|
|
|
Leberstraße 108; 1110 Vienna |
|
|
|
|
|
|
Use |
Extension card: Code Tag |
|
|
|
|
||
|
|
|
|
Function |
By equipping the carrier with passive transponder (no battery), called code |
||
|
|||
|
tags on both ends, all carries can receive there own identification number |
||
|
and so they can be assigned to a determinate station. The return to this |
||
|
"homestation" is possible without entering the address. |
||
|
Therefor only carriers can be used which are registered to the system and |
||
|
not registered carriers can’t be infiltrated in the system. |
||
|
Follow stations can be equipped: DRT110, DRT Front 110, E3S110 |
||
|
MSS110/160 DST160, DST-END160. |
|
|
|
|
|
|
Technical description |
The RFID 2000 board is a four antenna reader for Philips HITAG2 Chips. |
||
|
|||
|
The main controller is a PIC16F873A running with 16 MHz, which multi- |
||
|
plexes four tuning devices (Philips HTRC-110) and is connected with an I²C |
||
|
bus to the main board. Each antenna has an own tuning device (Philips |
||
|
HTRC-110), which produces the 125 kHz antenna signal and reads the |
||
|
chips. |
|
|
|
|
|
|
Technical data |
Sending frequency: |
125kHz |
Exciting frequency: 125kHz |
|
|||
|
|
|
|
Picture: |
|
|
|
|
|
|
|
Data sheets 1 - 2
8.3.11 RFID 2000 Vers.1.2
Model |
"Code Tag" (passive Transponder) |
||
|
|
|
|
Item |
Identification Transponder for the use in contactless applications |
||
|
|||
|
|
|
|
Frequency |
125kHz operating frequency |
||
|
|||
|
|
|
|
Power supply |
Data transmission and supply energy via RF link, no internal battery |
||
|
|||
|
The code tag is dedicated for the use in secure access systems (transpon- |
||
|
der and reader have to identify each other). The transponder requires no |
||
|
internal power supply; it derives its power from magnetic component of |
||
|
the RF carrier frequency generated by the reader antenna. |
||
|
|
|
|
Data storage |
EEPROM; guaranteed ten years of non-volatile data retention |
||
|
|||
|
|
|
|
Programming |
Programming via carrier programming unit. More than 100.000 erase/ |
||
|
|||
|
write cycles possible. |
||
|
|
|
|
Mechanical dimensions |
12x6x3mm (refer to pic) |
||
|
|||
|
|
|
|
Temperature |
Operating temperature:- 40°C bis 85°C |
||
|
|||
|
Storage temperature:- 55°C bis 125°C |
||
|
|
|
|
Protection class |
IP67 |
||
|
|||
|
|
|
|
Casting material |
epoxy resin |
||
|
|||
|
|
|
|
Picture |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Data sheets 1 - 3
8.3.11 RFID 2000 Vers.1.2
Model |
Antenna 110 |
|
|
|
|
Manufacturer |
Sumetzberger GmbH |
|
|
|
|
|
Leberstraße 108; 1110 Vienna |
|
|
|
|
Use |
To identify the coded carrier |
|
|
||
|
|
|
Technical data |
φ110mm |
|
|
|
|
|
|
|
Accessories |
Antenna holder: |
RP44965 |
|
||
|
|
|
Picture: |
|
|
|
|
|
Data sheets 1 - 4
8.3.11 RFID 2000 Vers.1.2
Model |
Antenna 160 |
|
|
Manufacturer |
Sumetzberger GmbH |
|
|
|
Leberstraße 108; 1110 Vienna |
|
|
Use |
To identify the coded carrier |
|
|
|
|
Technical data |
φ160mm |
|
|
|
|
Picture: |
|
|
|
Installation 2 - 5
8.3.11
RFID 2000 Vers.1.2
The installation of the RFID2000 on the SCB2000 have to done as follows
Plug the RFID circuit board in the extension board of the SCB2000 circuit board.
Pug the RFID board in the extension board of the
SCB2000 circuit board.
RFID board plugged to DCB
Installation 2 - 6
8.3.11
RFID 2000 Vers.1.2
The Installation of the Antenna on the SCB2000 - RFID2000 unit have to done as follows
The antenna 110 and 160 are installed as follows.
Remove the plug X1 from the RFID2000 circuit board (picture1 ) and put the plug from the antenna in the RFID2000 (picture 2).
Attention!
The white side of the plug from the antenna have to be on the upper side.
X1