OPERATOR’S MANUAL 650632--X--C
SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, TROUBLESHOOTING
INCLUDE MANUALS: 6695X--X LOWER PUMP END (PN 97999--002) &
S--632 GENERAL INFORMATION MANUAL (PN 97999--624)
6” AIR MOTOR
4:1 RATIO
6” STROKE
FOUR BALL PUMP SERIES
CARBON STEEL, ELECTROLESS NICKEL PLATED
650632--X43--C
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
RELEASED: 11--15--96
REVISED: 6--4--10
(REV. 02)
SERVICE KITS
• Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
• 61355 for repair of Air Motor section.
Service Note: The Air Motor Service/Parts Manual is not shipped
with the pump but it is included with each Service Kit. If this Service/
PartsInformation is needed, requesttheAirMotor Operator’sManual from ARO. (Manual 6564X--X, PN 97999--174).
• 637230- X43 for repair of Lower Pump section.
Refer to the chart on page 2 for description of --X43 options.
SPECIFICATIONS
Model Series (Refer to option chart) 650632--X43--C..
Type Air Operated, Four Ball....................
Ratio 4:1....................
Air Motor 65665--B.................
Motor Repair Kit 61355..........
Motor Diameter 6” (15.2 cm)...........
Stroke 6’’..................
Air Inlet 1/2’’ -- 14 NPTF--1(f).................
Air Exhaust 1--1/4’’, 11--1/2 NPTF--1(f)..............
Lower Pump End Series 66953--X43.....
Lower Pump Repair Kit 637230--X43.....
Material Outlet 3/4” NPTF--1(f)...........
PERFORMANCE
Air Inlet Pressure Range 30 -- 150 PSI (2 -- 10.3 bar).....
Fluid Pressure Range 120 -- 600 PSI (8.3 -- 41.4 bar).......
Max. Rec’d Cycles / Minute 70...
Displacement In
Volume/Cycle 45.4 oz. (1343 ml).............
Cycles Per Gallon 2.8..........
Flow @ 60 Cycles / Minute 21.3 GPM (80.6 lpm)....
Noise Level @ 60 Psi - 40 Cpm 84.8 db(A) *
* The pump sound pressure level has been updated to an Equivalent Continuous Sound
Level (L
microphone locations.
) to meet the intent of ANSI S1. 13 --1971, CAGI--PNEUROP S5.1 using four
Aeq
3
Per Cycle 82...
PUMP DATA
MODEL 650632- X43- C
Air Inlet
1/2--14 NPTF--1(f)
(Not Shown)
Air Motor
65665--B
38- 5/8
(981 mm)
17- 25/32
(452 mm)
14- 21/32
(372 mm)
FIGURE 1
Accessories Available: 91790 Silencer, 66101 Wall Bracket.
IMPORTANT
This is one of the four documents which support the pump.
Replacement copies of these forms are available upon request.
= 650632--X--C MODEL OPERATOR’S MANUAL
- GENERAL INFORMATION -- INDUSTRIAL PISTON PUMPS
- 6695X--X LOWER PUMP END OPERATOR’S MANUAL
- 6564X--X AIR MOTOR OPERATOR’S MANUAL
(See Manual 6564X-- X)
Spacer Section
NUT Y85--29--N (3)
WASHER Y14--625 (3)
CONNECTOR
SeeFigure2
SPRING 94457
SPACER ROD 93233--2
SPACER ROD 93233--1 (2)
Material Outlet
3/4’’ NPTF--1(f)
75_ FROM AIR EXHAUST
Lower Pump
66953-- X43
(See Manual 6695X--X)
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276 FAX(800) 892-6276
www.ingersollrandproducts.com
© 2010
CCN 99711836
650632--X
PACKING MATERIAL
PUMP OPTION DESCRIPTION CHART
PACKING MATERIAL (PACKINGS ARE UPPER AND LOWER UNLESS NOTED)
43--C
PLUNGER TYPE
SPRING ARRANGEMENT
7 GLASS FILLED PTFE (UPPER) P UHMW--PE/PTFE STAG’D (UPPER)
VIRGIN PTFE (LOWER
C UHMW--PE R PTFE/UHMW--PE STAG’D (UPPER)
F UHMW--PE/LEATHER STAG’D (UPPER) PTFE (LOWER)
UHMW--PE (LOWER)
SPRING ARRANGEMENT
4
MULTIPLE WAVE SPRING
) UHMW--PE (LOWER)
PLUNGER TYPE
3
HD SS W/HD CHROME PLATING
GENERAL DESCRIPTION
WARNING
mum operating pressure of 600 psi ( 41.4 bar) at 150 psi (10.3
bar) inlet air pressure.
INLET PRESSURE TO PUMP MOTOR
Pump ratio is an expression of the relationship between the pump motor area and the
lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied
to the motor of a 4:1 ratio pump it will develop a maximum of 600 p.s.i. (41.4 bar) fluid
pressure (at no flow) -- as the fluid control is opened, the flow rate will increase as the
motor cycle rate increases to keep up with the demand.
WARNING
safety precautions and important information.
HAZARDOUS PRESSURE. Do not exceed maxi-
PUMP RATIO X MAXIMUM PUMP
= FLUID PRESSURE
Refer to general information sheet for additional
• The Four--Ball pumps are primarily designed for the high volume
transfer of light and medium viscosity fluids compatible with carbon
steel. The lower pump is designed for easy priming and the double
acting feature is standard on all ARO industrial pumps. Material is
delivered to the pump discharge outlet on both the up and down
stroke.
• The motor is connected to the lower pump end by a spacer section.
This allows for lubrication of the upper packing gland and prevents
motor contamination because of normalwear and eventual leakage
through the material packing gland. Be sure the solvent cup is adequately filled with lubricant to protect the upper packings and insure
longest service life.
TROUBLE SHOOTING
Pump problems can occur in either the Air Motor Section or the Lower
Pump End Section. Use these basic guidelines to help determine which
section is affected.
If the pump will not cycle.
• Be certain to first check for non--pump problems including kinked,
restrictiveor plugged inlet/outlethoseor dispensing device. Depressurize the pump system and clean out any obstructions in the inlet/
outlet material lines.
• Refer to the motor manual for trouble shooting if the pump does not
cycle and/or air leaks from the air motor.
If the pump cycles but does not deliver material.
• Refer to the lower pump end manual for further trouble shooting.
PUMP CONNECTION -- UPPER / LOWER
NOTE: All threads are right hand.
1. Lay the pump assembly on a workbench.
2. Remove thethreenuts and washersfrom the threespacer rods (see
figure 1).
3. Pull theair motor fromthe lower pumpend until motor piston rodis in
the ‘‘down” position and lower pump end rod is in ‘‘up” position.
4. Using e--ring pliers,slide the retainingring up farenough to allowthe
sleeve to move upward and release the two connectors (see figure
2).
PUMP CONNECTOR DETAIL
Pump Motor
Piston Rod
FIGURE 2
Lower Pump
Piston Rod
REASSEMBLY
1. Align the pump motor with the lower pump end. Position the air inlet
of the motor 200_ from the material outlet.
2. Install thetwo connectors and retain with the sleeve,slide the retaining ring back into position.
3. Reinstall the spacer rods to the pump motor.
4. Bring the motor and lower pump together and retain with the three
nuts and washers.
RETAINING RING
90102
SLEEVE 90109
CONNECTOR
90096 (2)
PN 97999- 684
650632- X- C