Ingersoll-Rand 650556-1 User Manual

MANUAL
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
INCLUDE MANUALS: 66302ĆX LOWER PUMP END (PN 97999Ć648), 650685ĆX PUMP (97999Ć657), 65142XĆX FILTER (97999Ć6), P292X1ĆXXX PIGGYBACK (PN 100400Ć8) & GENERAL INFORMATION SĆ636 (97999Ć636)
650556-1
AIRLESS
6” STAINLESS STEEL, TWO BALL PUMP, 60:1 RATIO
SPRA
Y PUMP SYSTEM - CART MOUNTED
650556-1
RELEASED: 12-11-98 REVISED: 11-16-00 (REV.
B)
READ THIS MANUAL CAREFULL
OPERA
TING OR SER
SERVICE KITS
Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
61355 for repair of Air Motor section.
Service Note: The Air Motor Service / Parts Manual is not shipped with the pump but it is included with each Service Kit. If this Service / Parts Information is needed, request the Air Motor Operator's Manual from ARO. (Manual 6564XĆX, PNĂ97999Ć174).
637307ĆāP43 for repair of Lower Pump section.
PUMP
Model 650556Ć1...................
Pump System Type Cart Mounted Portable,.........
Pump Model 650685ĆP43..............
Ratio 60:1....................
Air Inlet 1/2"Ć14 N.P.T.F.Ć1 (female)................
Air Exhaust Muffler included.............
Material Inlet Suction Tube.............
Dimensional Data See page 3.........
Air Motor 65665ĆB.................
Motor Repair Kit 61355..........
Lower Pump End 66302ĆāP43...........
Lower Pump Repair Kit 637307āĆP43....
Weight (less carton) 111 Lbs (50 Kgs).......
Air Inlet Pressure Range 30Ć100 p.s.i. (2Ć6.9 bar).....
Fluid Pressure Range 1800Ć6000 p.s.i. (124Ć414 bar).......
Max. Rec'd Cycles / Minute 60... Displacement In3Per Cycle 5.5...
Volume / Cycle 3 oz. (90 ml)............
Cycles Per Gallon 41.9..........
Flow @ 60 Cycles / Minute 1.4 g.p.m. (5.4 lpm)... Noise Level @ 60 Psi Ć 40 Cpm 84.8 db(A) *
* The pump sound pressure level has been updated to an Equivalent Continuous Sound Level (L
meet the intent of ANSI S1. 13Ć1971, CAGIĆPNEUROP S5.1 using four microphone locations.
SYSTEM DA
Air Operated, Two Ball S'Steel
PERFORMANCE
TA
Aeq
Y BEFORE INST
VICING THIS EQUIPMENT
Inlet Air Regulator and Material Outlet ManIfold are not shown, see Fig. 2
IMPORTANT This is one of the six documents which support the system. Replacement copies of these forms are available upon request.
- 66302ĆX LOWER PUMP END OPERATOR'S MANUAL (97999Ć648)
= 650556Ć1 PUMP SYSTEM MANUAL (97999Ć840)
- 650685ĆX PUMP MODEL OPERATOR'S MANUAL (97999Ć657)
)to
- P292X1ĆāXXX PIGGYBACK OPERATOR'S MANUAL (100400Ć8)
- 65142XĆX MATERIAL FILTER (97999Ć6)
- GENERAL INFORMATION MANUAL SĆ636 (97999Ć636)
ALLING,
.
FIGURE 1
INGERSOLL-RAND COMPANY
P.O. BOX 151 D ONE ARO CENTER D BRYAN,OHIO 43506Ć0151
&
(419) 636-4242 D F
AX (419) 633-1674
E2000 D PRINTED IN U.S.A.
PARTS LIST / 650556-1
ITEM DESCRIPTION (Size in Inches)
1 Two Ball Piston Pump (1) 650685ĆP43
2 Cart Assembly (Includes Items 3 thru 14) (1) 67139
3 Cotter Pin (3/32") (2) Y15Ć35ĆC
4 Washer (4) 91522
5 Tip (2) 91011
6 Washer (3/8") (6) Y13Ć6ĆC
7 Screw (3/8" Ć 16 x 1Ć1/4") (4) Y6Ć66ĆC
8 Nut (3/8" Ć 16) (4) Y12Ć6ĆC
9 Wheel Assembly (2) 91515
10 Brace (1) 95102
11 Screw (5/16" Ć 18 x 3/4") (4) Y6Ć53ĆC
12 Nut (5/16" Ć 18) (4) Y12Ć5ĆC
13 Washer (5/16") (4) Y14Ć516ĆC
14 Cart WeldingAssembly (1) 67138
15 MaterialFilter (Includes Item 16) (1) 651422Ć70
16 Plug (3/8") (1) Y17Ć13ĆS
17 Muffler (1) 91790ĆZZ
QTY
PART NO. ITEM DESCRIPTION (Size In Inches)
OPERATING INSTRUCTIONS
QTY
j 18 3/4" Suction Hose Assembly (1) 622606Ć5 j 19 90_ Elbow (3/4") (1) Y43Ć15ĆS
j 20 Suction Tube (5 Gallon) (1) 94263Ć1
21 Hose Assembly (1) 628092ĆF
22 Gauge (1) 100067
23 Modular Piggyback Filter/Regulator (1) P29241Ć100
24 Nipple (1/2" x 1Ć1/2" (m)) (1) Y27Ć54ĆC
25 Bushing (1/2" Ć 14 (m) x 1/4" Ć 18 (f)) (1) 94271
26 Nipple (1/4" Ć 18 (m)) (2) 1950
27 Street Tee (1/4" Ć 18) (1) 94270
28 Needle Valve (1) 94269
29 Adapter (1" (m) x 1/2" (f)) (1) 94256
30 90_ Adapter (1" (m) x 1/4" (f) x 3/4" (f)) (1) 94254
31 Plug (1) Y17Ć11ĆS
j Parts included in 67140Ć1 Asm (std)
Available: 67140Ć2 Asm. uses 94263Ć2 (36" Inlet Tube)
PART NO.
WARNING
DO NOT EXCEED MAXIMUM OPERATING PRESĆ
SURE OF 6000 P.S.I. (414 BAR) AT 100 P.S.I. (6.9 BAR) AIR INĆ LET PRESSURE.
INSTALLATION
OPERATING INSTRUCTIONS / INITIAL SETUP PROCEDURE
This unit comes assembled except for the air supply hose, gun and maĆ terial hose which must be attached.
A connector, coupler and air supply hose and must be supplied
to the air regulator.
Attach a Ground wire to a suitable ground and the Ground Lug
provided on the pump Air Motor.
Keep containers covered to prevent contamination.
WARNING
REFER TO THE PUMP MANUAL FOR ADDITIONĆ
AL OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.
1. Turn the knob on the air regulator counterĆclockwise to zero p.s.i.
2. Attach hose and gun. Place pump inlet tube into a full container of material.
3. Start the pump to cycle by turning the air regulator knob clockwise. The pump will cycle several strokes until pressure is built up in the system, at which time it will stall, check for any loose fittings or leakĆ age. Check all connections and reĆtighten as necessary.
4. Relief Valve (28) is used to relieve pressure in the hose in order to change spray tips. Open the relief valve to relieve pressure. Close the relief valve to continue spray operation.