Infratech WD6024SS, WD4024SS, WD3024SS, W4024SS, W1524SS User Manual

...
0 (0)
Infratech WD6024SS, WD4024SS, WD3024SS, W4024SS, W1524SS User Manual

INSTALLATION USE & CARE MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE

ELECTRIC INFRARED RADIANT HEATER

TABLE OF CONTENTS

IMPORTANT INFORMATION

 

Warnings

2

 

 

Assembly Instructions

3

 

 

Wiring Instructions

3

 

 

Outdoor Installation

3

 

 

APPLICATION INFORMATION

 

Mounting Instructions

3-4

 

 

Typical Wiring (Schematics)

5

 

 

General Notes

5

 

 

Areas Covered (Table)

5-6

 

 

Location Suggestions

7

 

 

PARTS LIST

 

Replacement Parts List

6

 

 

Trouble Shooting Guide

6-7

 

 

Warranty

8

 

 

SAVE THIS MANUAL FOR FUTURE REFERENCE

WARNINGS

READ ALL INSTRUCTIONS BEFORE USING HEATER

Unit may be a source of possible shock. NEVER attempt to service heater without disconnecting its power source. Source of possible ignition.

CAUTION

High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3 feet (0.9m) from the front of heater and away from sides and rear.

MOUNTING HEIGHT/CLEARANCES

CLEARANCE FROM COMBUSTIBLES:

R=18"

R=6"

R=18"

·For Wall-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm) from ceiling and do not install less than 6' (1.8 m) if the heater is labeled as UL Listed and 8' (2.4m) if the heater is labeled as UL/CUL Listed from floor, while heater is set at a downward angle of 30 to 60 degrees.

·For Ceiling-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm) from ceiling and do not install less than 6' (1.8 m) if the heater is labeled as UL Listed and 8' (2.4m) if the heater is labeled as UL/CUL Listed from floor, while heater is at a maximum 30 degrees.

·Adjacent Heaters to be installed no less than 3' (0.9 m) apart.

·Do NOT operate within 25 feet of flammable/explosive material.

·Never block heater.

·Heaters greater than 240 Volts are for “Commercial Use Only. Risk of fire. Do not use as a residential or household heater.”

·A means for disconnection of the appliance must be incorporated in accordance with the local wiring codes.

·Do not use if the heating element is damaged or cracked.

“IMPORTANT INSTRUCTIONS” “SAVE THESE INSTRUCTIONS”

2

ASSEMBLY INSTRUCTIONS

This heater must be permanently installed and hard wired by a licensed electrician. Assembly procedure must be performed with no electrical power to unit.

WIRING INSTRUCTIONS

Step 1: Remove cover plate from junction box.

Step 2: Attach conduit.

Step 3: Use only copper or aluminum wire suitable for 90°C.

Step 4: Replace cover plate.

Step 5: Observe local electrical code regulations.

OUTDOOR INSTALLATION

Step 1: Heater must be mounted with reflector angled down.

Step 2: All electrical connections must be in compliance with the National Electric Code and local codes for outdoor wiring. Step 3: Use only wiring components UL/CE listed for outdoor use with IP X 4 minimum rating.

MOUNTING INSTRUCTIONS

These models may be chain or bracket mounted to any ceiling or horizontal surface. Installation must be such that 18" minimum clearance is maintained around the heater in front of the plane of the face. 6" of clearance provided by mounting brackets is required behind the plane of the face.

6" MOUNTING SURFACE WALL OR CEILING SWIVEL TO REAR OF HEATER MOUNTING BRACKETS (PAIR)

INSULATED HOUSING

8" WIDE

3”

LENGTH VARIES

DEPENDING ON

MODEL (MAX. 61-1/4")

Wall/ceiling brackets are furnished with all heaters. Their use is optional. When used, they allow heater to be fastened to wall or ceiling and then tipped up to 60°. Heater can also be hung in a horizontal position using chains or custom brackets. Heater must be level, but can be rotated around its horizontal axle.

3

Loading...
+ 5 hidden pages