Indesit UHP 64.5S F C M IX User Manual

Page 1
UHP6.5SFCMIX
English
Operating Instructions
COOKER HOOD
Contents
Operating Instructions,1 Assembly,2 Warnings,7 Installation,9 PYRAMID controls,10 Maintenance and care,10 Troubleshooting,11 Assistance,11
Page 2
6x Ø 8 x 40
4x Ø 3,5 x 9,5
6x Ø 5 x 45
1x
2x
ø 150-125mm
1x
ø 150mm
1x
5
4
3
2
2x
2
Page 3
1A
cm
min.
32
Ø150mm
1B
Ø120mm
Ø120
Ø150
Ø120mm
Ø120
Ø150mm
Ø150
Ø150mm
3
Page 4
2
=
3
Ø 8 mm
x6
=
=
=
4
6
Ø 8 mm
x6
5
x6
7
5 mm
x2
4
Page 5
x2
8 9
1
2
3
x2
1110
ø 150 ø 120
12 13
5
Page 6
B
A
14
15
ø 150
x2
ø 3,5 x 9,5
16
17 18
6
Page 7
Warnings
! Keep this manual for reference. If you sell, transfer or move the unit to another location, make sure to keep the manual with the product.
! Read the instructions carefully - they contain important installation, user and safety information.
! Do not tamper with the electrical or mechanical equipment of the product or its exhaust ducts.
General safety information
• The distance between the cookware support surface on top of the cooking appliance and the lowest part of the cooker hood must be at least:
65 cm if the hood is installed over a gas
cooktop
55 cm if the hood is installed over an
electric cooktop.
If the installation instruction manual for
the gas cooking appliance specifi es a greater distance, this measurement should be taken into account.
• Always wear work gloves when installing and servicing the unit.
• It is not intended for use by children or persons with sensory or mental disability and lack of experience or familiarity , except under the supervision or instruction of a person responsible for their safety.
• Make sure children do not play with the unit.
• Never operate the unit without its grease fi lter installed!
• NEVER use the hood as a support, unless expressly instructed to do so.
• The room must be adequately ventilated if the hood is used at the same time with other equipment burning gas or other fuels.
• Extracted air must not be conveyed into a duct used for exhausting combustion fumes from gas or other fuel-fired equipment.
• The cooker hood comes with anchor plugs which are suitable for use with most walls/ceilings.
However, you must contact a qualifi ed
technician to check the suitability of the materials in relation to the type of wall/ ceiling, which must be strong enough to support the weight of the unit.
• Caution! Do not hook the unit up to its electrical power supply until the installation has been completed.
• Before cleaning or servicing the unit, disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker .
• Observe all regulations in relation to air extraction.
• NEVER cook food with an open fl ame under the hood; open flames will damage the fi lters and may cause fi res. Never do this.
• Always supervise frying to make sure the heated oil does not catch fi re.
• Strictly observe all local regulations in relation to the technical and safety measures to be employed in fumes extraction.
7
Page 8
• Clean the product frequently, inside and out (AT LEAST ONCE A MONTH, and in observance of the maintenance instruction given in this manual).
• Failure to observe the hood cleaning and lter cleaning/replacement instructions can result in fi res.
• Never use the hood without its bulbs properly installed - electrocution hazard.
• The manufacturer is not liable for any inconvenience, damage or fi re caused by the unit as a result of failure to observe the instructions given in this manual.
• Caution! The unit's accessible parts can get very hot when used with cooking equipment.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
8
Page 9
Installation
Ducted version
GB
The installation procedure is illustrated in the fi rst pages of this manual. The installation must be done by a qualifi ed technician.
Electrical hook up
The mains voltage must match that given on the ratings label inside the hood itself. If the hood has a power plug, connect the hood to an easily accessible regulatory power socket. If it does not (direct connection to the mains), or the socket is not easily accessible, install a two-pole regulatory switch to enable total disconnection from the mains in case of category III overvoltage, as required by the installation regulations.
Caution! Always check that the mains cable is hooked up properly and check that it operates correctly before reconnecting the hood to the mains.
Air exhaust (for ducted units)
Connect the hood to a duct and wall exhaust hole of a diameter equal to that of the air outlet fl ange. Using a smaller diameter tube and exhaust hole reduces the extraction capacity of the hood and also increases its running noise. The manufacturer is not liable for any consequences of doing so.
The hood purifi es the air and expels it outdoors via an exhaust duct (dia. 150mm) connected to its outlet fl ange. The diameter of the exhaust tube must be equal to that of the outlet fl ange. Caution! The exhaust duct is not supplied and must be purchased separately. When routed horizontally , the tube must be angled slightly upwards (around 10°) to enable the air to be conveyed outdoors more easily. If the hood is fi tted with charcoal lters, they must fi rst be removed.
Filter version
The hood purifi es the air and returns it to the room. This version of the hood requires installation of an accessory active charcoal fi lter unit. This version requires an air defl ector, a reduction adapter and the charcoal fi lter/s. The top tube must have its air outlet slots uppermost.
Technical data
Model
PYRAMID 60cm 61-82 59.8 50 15/12
Height
(cm)
Width
(cm)
Depth
(cm)
dia. of
exhaust tube
(cm)
! Use the shortest duct required to achieve the purpose. ! Use a duct with as few bends as possible ! Avoid suddenly changing the diameter of the duct. ! The duct must have as smooth an inner surface as
possible.
! The duct must be made of regulatory material. ! Do not connect the hood to ues carrying combustion
fumes from other equipment (boilers, chimneys, stoves, etc.).
! Observe the instructions of the competent authorities in relation to the air exhaust. The air being exhausted may not be exhausted into a wall cavity unless the cavity in question is specifi cally intended for this purpose.
! Equip the room with air intakes to prevent the hood creating suction pressure in the interior (this must not exceed 0.04 mbar).
! The manufacturer is not liable for any consequences of failure to observe these instructions.
Filter or ducted?
! Your hood is supplied as a ducted unit. If you wish to use it as a fi lter unit, you must install the proper ACCESSORY KIT. Note: If supplied with the hood, the accessory active charcoal fi lter unit may already be installed. Instructions for transforming the hood from the ducted to the lter version are given in this manual (see “Filter version”).
Please check the plate in order to verify the total absorption and the light absorption
Power Voltage Cap Dimensions
Halogen 25 W 2 x 25 W 230 V G9 L40xØ14
The model is in accordance with the following EU directives:
• “Low voltage” Directive 2006/95/EC (12-12-2006)
• “EMC” Directive 2004/108/EC (15-12-2004)
•UR Reference no. 66/2014 integrating Directive no. 2009/125/EC.
Reference standard:
• EN 60704-2-13:2011; EN 60704-3:2006
• EN 61591:1997; EN 61591:1997/A1:2006; EN 61591:1997/ A2:2011; EN 61591:1997/A11:2014
• EN 50564:2011
9
Page 10
PYRAMID controls
GB
Models with mechanical keypad
T1 T2 T3 T4 T5
T1 Motor reset
Pressing the button while the hood is in operation turns it OFF.
T2 Speed 1
Pressing the button sets the hood to speed 1.
T3 Speed 2
Pressing the button sets the hood to speed 2.
T4 Speed 3
Pressing the button sets the hood to speed 3.
T5 Lights ON/OFF
Maintenance and care
Caution! Before cleaning or servicing the unit, disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker.
First cleaning
• Remove the protective fi lm
• Clean with a damp sponge and a little neutral soap
• Rinse off with a damp cloth
• Dry with a soft cloth; if the hood is stainless steel, dry along the metal's grain
Periodic cleaning
The hood must be cleaned frequently (at least as often as you service the grease fi lter), inside and out. Use a damp cloth and a neutral liquid detergent with lukewarm water. Do not use abrasive or corrosive products. Warning: Failure to observe the hood cleaning and fi lter cleaning/replacement instructions can result in fi res. Follow the instructions carefully . The manufacturer is not liable for any damage to the motor or fi res caused by incorrect care or failure to follow the above instructions.
To extract the grease fi lter, pull the spring loaded handle. If washed in a dishwasher, the metal fi lter may change colour, but this does not affect its performance.
Servicing the charcoal fi lter (B)
The charcoal filter retains unpleasant cooking odours. The filter saturates after a variable time, depending on the type of cooking and how often the grease filter is cleaned. The cartridge must
B
or regenerated Disassembly: Rotate the fi lter 90° to remove it from the suction assembly. Assembly: Fit the active-carbon fi lter into the suction assembly and rotate it 90° to secure it in place.
Replacing the bulbs
Disconnect the unit from the mains and remove the grease lter. Caution! Make sure the bulbs are cool before touching them.
1. Extract the guard by prising it out with a small
flat head screwdriver or something similar.
2. Replace the faulty bulb. Use only bulbs of the same type (for details, see the technical data in the following manual).
3. Refi t the guard (push it in).
Electrical cable
If the power cable is damaged, it can be replaced by the manufacturer or his technical service, to prevent any attendant risks.
SCRAPPING
The unit is marked for conformity with European Directive 2012/19/EC, Waste Electrical and Electronic Equipment (WEEE). By ensuring that the unit is scrapped properly, the user contributes to safeguarding the environment and public health.
be replaced at least once every twenty months. This fi lter can NOT be washed
Servicing the grease fi lter (A)
The grease fi lter retains the particles of grease produced during cooking; it must be cleaned at least once a month with a non-aggressive detergent, either by hand or with a low temperature, short dishwasher cycle.
10
The documents indicates that the product may not be treated as domestic waste but must be handed over to a sorting centre for electrical and electronic waste. Dispose of it in accordance with local waste disposal regulations. For further information on the handling, recovery and recycling of this product, contact the local authority , domestic waste disposal service or the reseller from whom you purchased it
symbol on the product or on its accompanying
Page 11
Troubleshooting
If something does not work, make the following simple checks before contacting Technical Service:
If the hood does not operate:
Check that:
• the unit is powered up.
• a speed has been set.
If the hood is not working effectively:
Check that:
• the selected motor speed is suffi cient to handle the amount of smoke and steam being produced.
• the kitchen is adequately ventilated for the unit to take air in.
• the charcoal fi lter is not exhausted (fi lter version).
If the hood turns off during normal operation:
Check that:
• the unit is powered up.
• the circuit breaker has not tripped.
GB
In case of faulty operation, before contacting Technical service, fi rst disconnect the machine from the mains for at least 5 seconds by pulling its plug, then reconnect it. If the fault persist, contact Technical Service.
Save energy and respect the environment
•Please use the hood by setting the speed in line with the
real extraction need; please limit the use of the "intensive speed" feature, if present. Using the hood in a rational way allows you to limit energy consumption and to avoid an useless waste of clean and air-conditioned air.
•Please don't turn on the hood light unless this is needed
to light the cooking area.
Assistance
! Never use the services of an unauthorised technician. Please have the following information to hand:
• The type of problem encountered.
• The appliance model (Mod.).
• The serial number (S/N).
The latter two pieces of information can be found on the data plate located on the appliance.
11
Page 12
GB
195125335.00
11/2013 - XEROX FABRIANO
Indesit Company S.P.A. Viale Aristide Merloni,47 60044 Fabriano (AN) www.indesit.com
12