the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as proved effective
by test.
Water pipe connections
and fixtures directly
connected to a potable
water supply shall be
sized, installed, and
maintained according to
Federal, State, and Local
Codes.
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or
operating this equipment
Release Date: October 28, 2005
Revision Date: December 22, 2005
Publication Number: 630460146OPR
Revision: A
*Bin adapters and condenser discharge air deflector may be equipped depending on your location or the size of
the storage bin.
Record the model number and the serial number of your ice equipment. These numbers are required when requesting information from your local dealer/distributor/service company.
Model Number –Date Installed –
Serial Number –Purchased From -
SERIAL NUMBER EXPLANATION
63 A 01 01 BC 101
Sequential Number
Product Code (PC) – Ice Maker
Week of Manufacture – First week of the year
Year of Manufacture – 2001
Control Code (Revision Level)
Manufacturing Location – Mason City
December 22, 2005
1
630460146OPR
SPECIFICATIONS
The following table contains equipment specification information for the Ice Machines.
Model
UNIT
Volts
Phase
Hertz
No. Wires
MIN. CIRCUIT
Amps
MAX. FUSE
SIZE
Amps
REFRIGERANT
Type
Weight (oz)
Weight (g)
COMPRESSOR
LRA
RLA
CONDENSER
FAN MOTOR
Amps
Watts
WATER PUMP
Amps
Watts
Model
UNIT
Volts
Phase
Hertz
No. Wires
MIN. CIRCUIT
Amps
MAX. FUSE
SIZE
Amps
REFRIGERANT
Type
Weight (oz)
Weight (g)
COMPRESSOR
LRA
RLA
CONDENSER
FAN MOTOR
Amps
Watts
WATER PUMP
Amps
Watts
XAC
322/330
R404a
19
539
1.7
50
XWC
830
R404a
33
936
NA
NA
XWC
322/330
R404a
15
426
58.8
9.2
NA
NA
XRC
830
R404a
170
4,820
60
8.9
NANA1.2 (2)
XAC
522/530
115
1
60
2+Ground
XWC
522/530
XRC
522/530
XAC
630
XWC
630
230
1
60
2+Ground
201520
201520
R404a
25
709
1.7
50
R404a
23
652
68
11.9
NA
NA
R404a
135
3,827
NA
NA
R404a
40
1,134
1.1
75
R404a
35
992
40.6
6.9
NA
NA
0.7
20
XAC
1030
XWC
1030
XRC
1030
XAC
1230
XWC
1230
230
1
60
2+Ground
20
20
R404a
42
1,191
60 (2)
R404a
33
936
90
12
NA
NA
R404a
R404a
170
4,820
1,191
13.5
NANA1.2 (2)
60 (2)NANA
49
96
R404a
45
1,276
84
12.2
0.7
20
XRC
630
R404a
170
4,820
NA
NA
XRC
1230
R404a
210
5,954
NA
NA
XAC
830
R404a
42
1,191
60
8.9
1.1
75
XWC
1230
E50
2+Ground
R404a
45
1,276
76
13.0
NA
NA
XAC
1444
E50
220
1
50
30
30
R404a
67
1,900
96
21.5
0.6
1/15hp
630460146OPR
2
December 22, 2005
XAC
20
20
322
E50
R404a
19
539
1.75
50
XRC
1844
3PH
R404a
NA
NA
XAC 330
E50
1015
1015
R404a
19
539
26.3
3.9
1.75
50
XWC
522/530
E60
230
1
60
2+Ground
34
6.8
NA
NA
XAC 522
E50
220
1
50
2+Ground
R404a
25
709
1.75
50
XWC
522
E50
220
1
50
2+Ground
R404a
23
652
31
5.6
NA
NA
XAC 530
E50
R404a
25
709
31
5.6
1.75
50
XAC
522/530
E60
230
1
60
2+Ground
R404a
26
737
34
6.8
1.2
60
Model
UNIT
Volts
Phase
Hertz
No. Wires
MIN. CIRCUIT
Amps
MAX. FUSE
SIZE
Amps
REFRIGERANT
Type
Weight (oz)
Weight (g)
COMPRESSOR
LRA
RLA
CONDENSER
FAN MOTOR
Amps
Watts
WATER PUMP
Amps
Watts
Model
UNIT
Volts
Phase
Hertz
No. Wires
MIN. CIRCUIT
Amps
MAX. FUSE
SIZE
Amps
REFRIGERANT
Type
Weight (oz)
Weight (g)
COMPRESSOR
LRA
RLA
CONDENSER
FAN MOTOR
Amps
Watts
WATER PUMP
Amps
Watts
XAC
1444
R404a
67
1900
0.6
1/15
HP
XAC
630
E50
1520
1520201515
R404a
40
1134
34
5.5
1.1
75
XWC
1444
30
30
R404a
36
1021
108
17
NA
NA
XAC
830
E50
R404a
42
1191
54
8.1
1.1751.2(2)
XRC
1444
R404a
7088
XAC
1030
E50
220
1
50
2+Ground
R404a
1191
11.3
60(2)
230
1
60
2+Ground
R404a R404a R404a
250
NA
NA
1/3HPNANA
R404a
42
83
1.2(2)
XAC
1844
2.7
XAC
1230
E50
49
1389
76
13
60(2)
XWC
1844
30
40
179
28
XAC
1844
3PH
R404a R404a
2.7
1/3HPNANA
XRC
1844
NA
NA
0.7
XWC
1844
3PH
230
3
60
3+Ground
201515
135
17
0.7
NA= Not applicable
Important: All product supply voltage specifications are –5%/+10% for proper component
operation.
December 22, 2005
3
630460146OPR
GENERAL
FREIGHT DAMAGE CLAIMS PROCEDURE
The deliverer of your equipment (freight company, distributor or dealer) is responsible for loss or damage of your
shipment. All claims must be filed with the deliverer of your equipment. Please follow the steps below to determine if your shipment is satisfactory or if a claim must be filed:
1. Check the number of products delivered against the number of products listed on the delivery receipt.
Should the totals not match, have the driver note all errors on both copies and both you and the driver sign
and date said notation.
2. Inspect all cartons for visible damage. Open and inspect as required before the driver leaves and have him
or her note any damage on the receipts. All damaged claims must be inspected within 15 days of delivery.
Notify your carrier immediately if concealed damage is found after delivery.
3. Should concealed damage be found when product is unpacked, retain the packing material and the product
and request an inspection from the deliverer.
4. All claims for loss or damage should be filed at once. Delays in filing will reduce the chance of achieving a
satisfactory resolution to the claim.
TECHNICAL SPECIFICATIONS
S Cube Size: 5/8”W X 7/8”H X 7/8”D
S Ambient Temperature: 50_F/10_C – 100_F/38_C
S Water Temperature: 50_F/10_C – 90_F/32_C
S Water Pressure: 20–80 psi
S Maximum Fuse Size: See Nameplate
S Circuit Amp: See Nameplate
S Refrigerant Type: R–404a
S Refrigerant Charge: See Nameplate
Microban
IMI Cornelius Ice Maker Product includes Microbanr Built–In Product Protection to inhibit the
growth of odor and stain causing bacteria, mold, and mildew. This will improve the units performance between cleaning, but should not exclude the standard cleaning process. Please
refer to the Maintenance section of this manual for proper cleaning procedures. Microban is
a registered trademark of the Microban Products company, Huntersville NC 28078.
630460146OPR
4
December 22, 2005
INSTALLATION INSTRUCTIONS
Installation and start-up of the equipment should be performed by the distributor or the dealer’s professional
staff.
LOCATION OF EQUIPMENT
For maximum performance the location should be away from heat sources such as ovens, direct sunlight, hot
air discharge, etc.
To reduce cost of maintenance and loss of efficiency, avoid placing air-cooled equipment in areas where grease,
flour and other airborne contaminants are present. Allow a minimum of 6I (15.24 cm) clearance at the rear and
right side for proper air circulation. Restricted air circulation will affect the efficiency and required maintenance of
the product.
IMPORTANT: Never operate your equipment in room temperature below 50_F (10_) or above 100_F
(38_C). Should the location of your product ever be exposed to freezing temperatures, it must be shut
down and winterized.
Baffle Installation
NOTE: The baffle is only used on the 1030, 1230, 1444, and 1844.
The baffle must be used when the right hand side of the icemaker is installed in a corner. This will prevent discharge air from recirculating to the condenser.
1. Loosen three screws, as shown in Fig. 1.
2. Install baffle, as shown in Fig. 1. with paper towards the front of the unit.
3. Tighten the three screws.
December 22, 2005
FIG. 1
5
630460146OPR
EQUIPMENT SET-UP
The following steps refer to the set-up of the ice bin and the cuber:
1. Remove the bin from its carton, place it on its back and install the legs into the bottom of the bin. Bins must
be installed on legs or sealed to the floor with RTV-732 sealant.
2. Set the bin up on its legs. Place the bin in its final location and level it with the adjustable feet in the legs.
NOTE: It is critical that the unit be level to ensure adequate ice production.
3. Unpack the cuber from its carton, and set in place on the bin and adjust as required. Leave all panels on
the cuber until it is set in place on the dispenser or bin.
4. Remove all internal packing from the cuber. Remove tape from evaporator curtain.
THREAD LEVELING
LEG INTO BASE
FIG. 2
FIG. 3
NOTE: Bin adapter and condenser air baffles may be required in certain installations.
630460146OPR
6
December 22, 2005
DISPENSER INSTALLATION
1. The proper cuber/dispenser installation package should be ordered. This package will include gasket material, and hold-down bracket, and bin stat.
2. RTV applications (See Fig. 2 above). If the ice bin is full, new ice will not be able to drop. Instead it blocks
the evaporator curtain open and no additional ice is made. This new ice may start to melt and the resulting
liquid can leak out of the joint between the ice maker and bin. To prevent this problem, seal the joint with
food grade silicon sealant.
3. Install bin thermostat (Part Number 631500074).
Electrical Service Line
Manual Disconnect
Switch
Shut-Off Valve
Water Filter
STRAIN RELIEF
MUST BE USED
Dump
Valve
Drain
Tube
*Air Gap 4”
“minimum”
FIG. 4FIG. 5
Bin Drain
Floor Drain
Tube
AIR-COOLED MODELS
* An air gap of at least twice the diameter of the water supply inlet plus a minimum of 1” (25 mm) must
exist between the floor drain and drain tube.
Bin Drain
Tube
WATER-COOLED MODELS
Electrical Service Line
Manual Disconnect Switch
Shut-Off Valve
Water Filter
Shut-Off Valve
Condenser Water Inlet
Strain Relief
must be used
Dump Valve
Drain Tube
Condenser Water
Drain Tube
*Air Gap 4”
“minimum”
Floor Drain
Note: Leave all panels on the cuber until it is in place on the bin.
PLUMBING CONNECTIONS
1. All plumbing lines and connections must conform to local and
national plumbing codes.
2. Line shut-off valves must be located in supply water lines for cuber and condenser if product is watercooled. Water supply to water-cooled condenser must include a stand-pipe to prevent “water
hammer”.
3. Should your local water supply quality require the installation of a water filter system, consult your local distributor or dealer for proper size required.
4. Water supply pressure must not be lower than 20 PSI (1.37 BAR), nor should it exceed 80 PSI (5.516
BAR).
NOTE: Water filters larger then 5 microns do not give proper protection. Water pressures above 80
PSI (5.516 BAR) will destroy the filter.
DRAIN LINES:Bin and cuber drain lines must never be connected together and must be vented.
NOTE: Always flush inlet water lines 1–2 minutes before connecting to Ice Maker.
December 22, 2005
7
630460146OPR
ELECTRICAL
1. All wiring and connections must conform to national and local electrical codes.
2. Wire size and circuit protection must conform to specifications and cuber must be on a separate electrical
circuit.
3. Strain relief connectors must be used at the junctions box of the control box and the cuber.
4. Cuber must be grounded by the control box ground screw or other method for intentional safety grounding
that meets code requirements.
5. A manual disconnect in a convenient location to the cuber must be installed.
NOTE:See Remote Install Instructions in the Xtreme Service and Training Manual (TP00952).
NOTE: All HP-62 (R404A) ice machines have a voltage range of –5%, +10% from the serial plate rating.
INSTALLATION CHECK POINTS
1.
2.Does electrical and plumbing meet code requirements?
3.If water-cooled, are inlet and drain connections to condenser correct to prevent “water hammer”?
4.
5.Is there 6I clearance on all sides and top for proper air circulation?
6.
7.
NOTE: A 6” top clearance will improve service accessibility.
Has bin and cuber been leveled and sanitized?
Are drain lines separate and vented?
Does the water curtain move freely, and does the inlet solenoid valve shut off incoming water to the
water pan?
Has the unit been properly sealed to the bin or dispenser?
START UP SEQUENCE
1.
2.
3.The unit will go through a 45 second hot gas defrost to remove any ice on the evaporator.
NOTE: If there is a very large slab of ice on the evaporator you will need to push the manual harvest
button to remove it.
4.If the water pan is empty, the unit will go through a fill cycle.
5.
Check all connections.
Turn on the main power switch, the red LED will flash (6) times then be on steady for (4) seconds.
There will be approximately a (45) second evaporator pre chill, then the water pump will start, and the
freeze cycle begins.
PREVENTATIVE MAINTENANCE SEQUENCE
The installation is not complete until you are sure the owner–operator understands the cuber operation and his
or her responsibility of preventative maintenance.
Does the owner–operator know:
1.
2.How to start and/or shut down the product, clean and sanitize it?
3.
4.
5.
NOTE: CONDENSER SENSOR USED ONLY ON A/C UNITS. 1.8K ohm RESISTER USED ONLY ON W/C
& R/C UNITS.
630460146OPR
Location of electrical disconnect switch and water shut–off valves?
Bin full operation and reset operation of high pressure cutout (water–cooled and remote products
only)?
How to clean the condenser and fan blade?
Whom to call for product information and/or service?
8
December 22, 2005
OPERATION
UNIT SELECTION
1. The unit selection dip switches tell the microprocessor the correct water level difference for harvest and the
number of proximity switch circuits to monitor.
2. The unit selection dip switches are a series of 3 switches that can be placed in either the ON or OFF position.
3. The following list shows the dip switch settings for each model:
NOTE: The unit selection switches are preset at the factory to the correct model. Use the chart below if
the control is replaced.
Model
Switch 1Switch 2Switch 3Proximity Switch Circuits
500ONOFFOFF1
300OFFOFFOFF1
600/800/1000OFFONOFF1
1200ONONOFF2
1400/1800OFFOFFON2
NORMAL OPERATIONS
1. Start up sequence.
2. Secondary start up.
3. Dump cycle.
4. Water fill cycle.
5. Pre chill cycle.
6. Freeze cycle.
7. Harvest cycle.
8. Continue with the dump cycle.
9. Fan cycle runs continuously after the secondary start up (88–100_F).
10. The safety features are monitored during the proper cycle.
PRESSURE
LINE
December 22, 2005
FIG. 6
PRESSURE TRANSDUCER
START LEVEL (A)
WATER PAN
DEFROST LEVEL (B)
DUMP LEVEL (C)
1. During fill, water level rises to (A).
2. During Ice Product cycle, water level lowers
to (B). Defrost cycle initiated.
3. During Defrost cycle, water level lowers to (C).
4. When Proximity Switch(es) close, fill valve
opens and water level rises to (A).
9
630460146OPR
START UP SEQUENCE (PRIMARY)
1. Check all connections.
2. Turn on the main power switch, the red LED will flash (6) times, then be on steady for (4) seconds.
3. The unit will go through a 45 second hot gas defrost to remove any ice that might be on the evaporator.
NOTE: If there is a very large slab of ice on the evaporator you will need to push the manual harvest
button to remove it.
4. If the water pan is empty, the unit will go through a fill cycle.
5. There will be approximately a (45) second evaporator pre chill, then the water pump will start, and the
freeze cycle begins.
SECONDARY START UP
1. Compressor starts after ERROR LED extinguishes, and the green COMP LED turns on.
2. Compressor runs continuously after secondary start up sequence.
3. Hot gas valve opens for a 45 second period.
4. Green GAS LED is on when the hot gas valve opens.
5. After 45 seconds, the hot gas valve de–energizes.
NOTE: If there is a very large slab of ice on the evaporator you will need to push the manual harvest
button to remove it.
DUMP CYCLE
1. Dump valve opens.
2. Green DUMP LED is on when the dump valve energizes.
3. If the water level is not at the high level the fill valve opens.
4. The green FILL LED is on when the fill valve energizes.
5. If the water level is below the minimum level the water pump remains off.
6. Once the water is a above the minimum level the water pump turns on.
7. The green PUMP LED is on when the water pump is on.
8. After a 15 second flush cycle the fill valve de–energizes.
9. The water pump turns on to drop the water level to the minimum level.
WATER FILL CYCLE
1. The fill valve opens.
2. The green FILL LED is on when the fill valve energizes.
3. Once the water level reaches the maximum level the fill valve de–energizes.
NOTE: During the initial filling of the water pan, air is captured inside the pressure sensor pick up.
When the pressure inside, the pressure sensor pick up rises to a predetermined value, the pressure
transducer shuts off the water fill valve and starts the pre chill cycle then the freeze cycle.
PRE CHILL CYCLE (300’S, 500’s, 600’s, 800’s, 1000’s, and 1200’s)
1. The water pump turns on 45 seconds into the cycle.
2. After another 45 seconds, the fill valve turns on.
3. Once the water level reaches the maximum level the fill valve de–energizes.
PRE CHILL CYCLE (1400’s and 1800’s)
1. After the water fill cycle is complete, the water pump turns on.
2. When the water temperature reaches 40 degrees F, the pump turns off.
3. After one minute, the pump comes back on.
4. After another ten seconds, the fill valve opens.
5. Once the water level reaches the maximum level, the fill valve closes.
630460146OPR
10
December 22, 2005
FREEZE CYCLE
1. Ten seconds after the fill valve turns off, the microprocessor records the water level.
2. Using the recorded high water level, the calibration level and the ice thickness level, the microprocessor
calculates a harvest level.
3. The microprocessor monitors the water level until it reaches the harvest level.
As ice builds on the evaporator the water level in the water pan drops. This is called batch harvesting.
HARVEST CYCLE
1. The hot gas solenoid opens.
2. The microprocessor monitors the proximity switches waiting for the circuit to open.
3. Once all of the proximity switch circuits have opened, the hot gas solenoid closes.
4. The microprocessor monitors the proximity switches to close.
5. Once all the proximity switch circuits close, the harvest cycle terminates.
NOTE: When the pressure inside, the pressure sensor pick up lowers to a predetermined value, the
pressure transducer starts the harvest cycle.
DUMP CYCLE
1. The dump cycle can be changed by moving the setting on the dump cycle dip switches.
2. If both switches are off, the machine dumps water after each cycle. This is the factory set point.
3. If switch 1 is on an switch 2 is off, the machine dumps after every third harvest.
4. If switch 1 is off an switch 2 is on, the machine dumps after every seventh harvest.
5. Once the water reaches the minimum level, the dump valve de–energizes and the pump turns off.
FAN CONTROL
1. Fan control operates when the hot gas solenoid is closed.
2. The fan turns off when the condenser temperature is below 88_F.
3. The fan turns on when the condenser temperature is above 100_F.
ADJUSTING BRIDGE THICKNESS
For optimum ice production and maximum cube separation, the ice connecting the individual cubes should be a
minimum of 1/8I (.32cm) thick.
FIG. 7
BRIDGE 1/8I (0.32 cm)
Should a different thickness of the bridge be desired, it will be required to adjust the ice thickness “POT”, located on the circuit board, as follows:
1. Thinner Bridge – turn the ice thickness “pot” adjustment screw C.W. one full turn. Allow two cycles before
determining if additional adjustments are required.
2. Thicker Bridge – turn the ice thickness “pot” adjusting screw C.C.W. one full turn. Allow two cycles before
determining if additional adjustments are required.
NOTE:Never judge the thickness of the ice from the first batch of the ice produced – the first cycle is
a balance cycle. Always wait for the second cycle before making any adjustments.
TOTAL ICE CAPACITY
Ice capacity of any ice maker is affected by many operating conditions, such as water and air temperature and
location factors. Please review the capacity tables in this manual for average 24-hour capacity under various
conditions.
NOTE:All printed capacity ratings are 10% except 50 HZ units. These products have 12% increase
in cycle time and capacity decrease of approximately 17%.
December 22, 2005
11
630460146OPR
ICE PRODUCTION CHECK
If air cooled, take air temperature at the intake of the condenser, 2I from the condenser fins, and Incoming water temperature at the outlet of the “fill” valve.*
Cycle time (CT) = freeze time plus harvest time, in minutes and seconds. 1440 divided by CT = number of
cycles per 24 hours.
Measure weight of ice from one cycle in pounds and fractions of a pound.
EXAMPLE: Weight/cycle x cycles/day = total production/24 hrs. Compare to the production tables.
* If water cooled, be certain water regulator valve is set to maintain 260 - 271 PSI head pressure, or set condenser outlet temperature to 108_F – 111_F
LED INDICATORS
The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.
Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads, &
connections.
Yellow:
S Evaporator switch(s) (proximity)
Green:
S Water dump valve
S Compressor contactor
S Water Pump
S Hot Gas Valve
S Condenser Fan (cycles on & off with fan)
S Fill Valve
Red:
S Error (located on the electrical box front).
S Delay (located on the electrical box front).
S Ice thickness Adjustment.
Refer to flash codes for control and system diagnostics. Add the flash codes before status indicators.
FLASHING CODE FOR SELF DIAGNOSTICS (300’s, 500’s, 600’s, 800’s,
1000’s, and 1200’s)
Delay LEDError LED
1High Condenser Temperature Warning1High Condenser Temp. Shutdown
4Low Condenser Temperature Delay2Failed Freeze Time Out Shutdown
5Water Inlet Warning3Failed Harvest Shutdown
5Failed Water System Shutdown
6End of Clean Cycle Shutdown
8Open Condenser Thermistor Shutdown
630460146OPR
12
December 22, 2005
FLASHING CODE FOR SELF DIAGNOSTICS (1400’s and 1800’s)
Delay LEDError LED
1High Condenser Temperature Warning1High Condenser Temp. Shutdown
4Low Condenser Temperature Delay2Failed Freeze Time Out Shutdown
5Water Inlet Warning3Failed Harvest Shutdown
4Failed Water Temperature Shutdown
5Failed Water System Shutdown
6End of Clean Cycle Shutdown
7Open Water Thermistor Shutdown
8Open Condenser Thermistor Shutdown
Status Indicator
Green LEDCondenser Fan
Yellow LEDLeft Water Curtain
Green LEDHot Gas Valve
Green LEDWater Pump
Yellow LEDRight Water Curtain
Green LEDCompressor Contactor
Red LEDError
Green LEDDump Valve
Green LEDFill Valve
Yellow LEDDelay
Red LEDIce Thickness Adjustment
S Check all water fittings and tubes for leaks. Also, make sure the refrigeration tubing is not rubbing or vibrat-
ing against other tubing panels, etc.
S Do not stack anything (boxes, etc.) on or around the ice machine.
S Do not cover the ice machine while it is operating. There must be adequate air flow through and around the
ice machine to ensure long component life and adequate ice production.
CLEANING THE EXTERIOR
1. Clean the area around the ice machine as often as necessary to maintain cleanliness and efficient operation.
2. Sponge dust and dirt off the outside of the ice machine with mild soap and water. Wipe dry with a soft clean
cloth.
WARNING: Stainless steel panels should be cleaned with mild soap or a commercial
stainless steel cleaner. Do not use cleaners containing bleaching agents: they usually
contain chlorine which stains stainless steel. Heavy stains should be removed with
stainless steel wool. Never use plain steel wool or abrasive pads because they will scratch
the panel and cause rusting.
CLEANING THE CONDENSER
CAUTION: Condenser fins are sharp. Use care
when cleaning them.
Disconnect electric power to the ice machine at the electric service switch box before cleaning condenser!
Air–Cooled Condenser
A dirty condenser restricts airflow which results in excessively high operating temperatures. High operating temperatures reduce ice production and shorten component life. Clean the condenser at least every six months.
CAUTION: Condenser fins are sharp. Use care
when cleaning them.
December 22, 2005
15
630460146OPR
1. Clean the outside of the condenser with a soft brush or vacuum with a brush attachment. Brush or wash
condenser from top to bottom, not from side to side. Be careful not to bend the fins. Shine a flashlight
through the condenser to check for dirt between the fins.
2. If further cleaning is required, blow compressed air through the condenser from the inside. Take care not to
bend the fan blades. Shine a flashlight through the condenser to check that all the dirt is removed.
Any bent condenser fins must be straightened with a fin comb. Contact
your local service agent to do this service.
Water-Cooled Condenser (and regulating valve)
The water-cooled condenser and water regulating valve may require cleaning due to scale build-up.
Low ice production, high water consumption, and high operating temperatures and pressures all may be symptoms of restrictions in the condenser water circuit.
The cleaning procedures require special pumps and cleaning solutions and, therefore, should be performed by
qualified maintenance or service personnel.
CLEANING THE INTERIOR
Approved ice machine cleaners by brand names:
S Calgon Nickel Safe (green color only)
NOTE:Failure to use approved products will void the warranty.
CAUTION: Ice machine cleaners are acidic-based chemicals. Before beginning any
cleaning of the cuber, the ice in the storage bin or dispenser must be removed.
WARNING: When using any chemical, rubber gloves and eye protection should be worn.
WARNING: Do not remove the small clear tube from the fitting located in the water pan.
Doing so will result in erratic behavior of the ice machine.
Cleaning Procedure if there is Ice on the Evaporator Plate.
1. Turn the power switch on.
2. Press the clean button to start a 4 minute defrost cycle (button is located on the front of the control panel).
3. After harvest cycle, add ice machine cleaner and follow cleaning procedure.
Use ice machine cleaner on a coarse-surface cloth material (such as terry cloth) and wipe down the inside wall
of the evaporator area, the water pan, the water curtain and the plastic water deflector. If the water distributor
tube has heavy scale build-up, remove and soak it in full-strength nickel safe ice machine cleaner (or exchange
the tube and clean the scaled tube at a later date). *See figures and #6 and #7.
Cleaning the Water System and Evaporator
1. Turn the power switch to “OFF”.
2. Remove all ice from the storage bin.
3. Remove the water curtain(s), pour 1/2 oz. of ice machine cleaner down the top of the evaporator. The
cleaner will drain into the water pan.
4. Remove the water distributor tube (refer to fig. 10), disassemble water distributor tube (refer to fig. 11), and
clean with the brush and “Calgon Nickel Safe” ice machine cleaner.
630460146OPR
16
December 22, 2005
FIG. 10
INNER WATER DISTRIBUTOR
”O” RING
SCALE 1:2
FIG. 11
WATER DIST. ASSEMBLY
”O” RING
INNER WATER DISTRIBUTOR BARB
5. Return the water curtain(s) to their proper operating positions.
6. Add 5 oz. for the 300’s, 8 oz. for the 500’s, 600’s, and 800’s, 12 oz. for the Dual Evaporator, and 16 oz. for
the Quad of “Calgon Nickel Safe” ice machine cleaner directly into the water pan (green only).
7. Turn the power switch to “ON” , allow the compressor to start, and depress the clean button two times on
the front of the electrical box.
8. The unit will run through a fifteen (15) minute cleaning cycle. This includes 3 rinse cycles.
9. Once the cleaning cycle finishes, the error LED will flash 6 times.
10. When the clean cycle is complete, turn the power switch to “OFF” for five (5) seconds, then to “ON”. The
unit will return to normal operating mode. Discard the first batch of ice produced.
NOTE: Please Take Note of the Following:
S Ice machines should only be cleaned when needed, not by a timed schedule of every 60 days, etc.
S Should your ice machine require cleaning more than twice a year, consult your distributor or dealer about
proper water treatment.
Sanitizing the Water System and the Evaporator
NOTE: To be performed only after cleaning the ice machine:
1. Turn the power switch to “OFF”.
2. Add 1/4 ounce (7.08 g) sodium hypochlorite solution (common liquid laundry bleach) to the water pan. You
may also use a commercial sanitizer such as Calgon Ice Machine Sanitizer following the directions on the
product label.
3. Turn the Cuber power switch “ON” allowing the compressor to start. Depress the clean button two times on
the control board. The unit will run through a 15 minute sanitizing cycle.
4. Once the sanitizing cycle is complete, the error LED will flash 6 times. Turn the power switch to “OFF” for
5 seconds and then turn to “ON”. Discard the first batch of ice produced.
5. To sanitize the bin and other surface areas, use 1 ounce of liquid bleach per gallon of water and wipe all
areas with the solution. Or use a commercial sanitizer.
6. Cleaning and sanitizing are now complete. Cuber may be returned to normal service.
December 22, 2005
17
630460146OPR
630460146OPR
18
December 22, 2005
BEFORE CALLING FOR SERVICE
If a problem arises during the operation of your ice machine, follow the checklist below before calling for service.
CHECKLIST
Problem
ICE MACHINE DOES NOT
OPERATE
ICE MACHINE STOPS AND
CAN BE RESTARTED BY
TURNING POWER SWITCH
OFF THEN BACK ON AGAIN
ICE MACHINE DOES NOT
RELEASE ICE OR IS SLOW
TO HARVEST
POOR QUALITY ICE. (ICE
SOFT OR NOT CLEAR)
Probable CauseRemedy
A.No electrical power to ice
machine.
B.Tripped high pressure cutout.B.Reset high pressure cut-out.
C.ON switch set improperly.C.Set switch at ON.
D.Water curtain stuck open.D.Water curtain must swing freely.
A.Safety limit feature stopping
ice machine.
A.Ice machine evaporator dirty.A.Clean the evaporator, the water
B.Ice machine not level.B.Level ice machine.
C.Air–cooled models: low
ambient.
D.Water regulating valve leaking
during harvest mode
(water–cooled ice machines).
A.Quality of incoming water.A.Contact qualified service
B.Water filtration element needs
to be changed.
C.Ice machine dirty.C.Clean and sanitize ice machine,
D.Water dump valve not working.D.Disassemble and clean the water
E.Water softener working
improperly (if installed).
A.Replace fuse, reset circuit
breaker, turn on main switch.
A.Refer to safety limit feature.
system and sanitize ice machine.
C.Minimum ambient is 50_F .
D.Refer to water–cooled condenser.
company to test quality of water
and make appropriate filter
recommendations.
B.Replace filter.
pages 5 & 6.
dump valve.
E.Repair water softener.
SAFETY LIMIT FEATURE
In addition to standard safety controls such as the high pressure cut-out, your ice machine features built-in safety limits that stop the ice machine if conditions exist that may result in a major component failure.
Before calling for service, restart the ice machine using the following procedures:
1. Turn power switch off and then back to “ON” position. If the safety limit feature has stopped the ice machine,
it will restart after a short delay. Proceed to Step 2, but if the ice machine does not restart, refer to “Ice Machine Does Not Operate” in the problem checklist.
2. Let the ice machine operate to determine if the condition recurs...
a. If the ice machine stops again, the condition recurred; call for service.
b. If the ice machine continues to run, the condition corrected itself; let the machine run.
December 22, 2005
19
630460146OPR
WARRANTY
IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country, please write, fax or telephone the IMI Cornelius office nearest you
(www.cornelius.com). Please provide the equipment model number, serial number and the date of