IMI Cornelius, Inc. QUANTUM Service Manual

INSTALLATION & SERVICE MANUAL
IMI CORNELIUS INC.
QUANTUM SERIES
www.cornelius.com
Part Number- 720901120 Revision B - November 23, 2004
TABLE OF CONTENTS
PREINSTALLATION........................................................................... 2
Receiving ..............................................................................................................2
Unpacking............................................................................................................. 2
Counter Location ..................................................................................................2
installation specifications ...............................................................3
Water Supply ........................................................................................................3
Electrical................................................................................................................3
Space ...................................................................................................................3
Connecting Water Supply .....................................................................................3
Filling Unit with Water ...........................................................................................3
Flushing and Sanitizing on Start Up .....................................................................4
Programming Portion Control (optional) ...............................................................4
Cancel/Pour Button.............................................................................................. 4
Concentrate loading and brixing ....................................................5
Placing Concentrate Products on Dispensing Platform........................................ 5
Changing Concentrate Flavor ...............................................................................5
Pump Priming....................................................................................................... 5
Brix Setting........................................................................................................... 5
Cleaning and sanitizing procedures ...............................................6
Daily: System Flush Procedure............................................................................ 6
Daily: Part Washing.............................................................................................. 6
Weekly: Sanitizing Procedure............................................................................... 6
Weekly: Check Brix Setting.................................................................................. 7
Semi-Annual: General Cleaning........................................................................... 7
Yearly: Replace Pump Tubing.............................................................................. 7
Quantum Series Installation and Service Manual
UNIT SPECIFICATIONS
Clearance Recommended: 12” (30.48 cm) on top and 4” (10.16 cm) required in back for air circula­tion if sides are blocked off. If sides are open only 2” (5.08) are required in back. Space between bottom of unit and counter cannot be obstructed in foot print area.
Electrical Connection: 6ft. long (1.83m) power cord with 3-prong plug attached to dispenser. Export models have line cord less plug.
Power Supply: 15 amps at 120 volts or 10 amps at 220 volts. Water Connection: 3/8” (0.95 cm) SAE male flare fitting on dispenser. Water Supply Requirements: 80 psi (5.5 bar) maximum static pressure. 20 psi (1.4 bar) minimum
dynamic pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 ounces (88.7ml) per second water flow.
- 1 - 720901120
Quantum Series Installation and Service Manual
PREINSTALLATION
RECEIVING
Each unit is completely tested and inspected before shipment. At time of shipment, the carrier accepts the unit and any claim for damage must be made with the carrier.
Upon receiving from the carrier, please, inspect the carton for visible damage. If damage exists, have the carrier make a note on the bill of lading and file a claim with the carrier.
UNPACKING
Remove staples securing carton to pallet.
Lift carton up and off of unit.
Remove top insert and shipping bag.
Open the upper cabinet door and remove installation kit.
Remove bolts securing unit to pallet.
Lift unit off of pallet.
Open the package, take legs and secure them to the bottom of the unit.
NOTE: Do not lay the unit on sides or on the back.
Tilt the unit only when securing legs.
If the unit is to be transported from the place where it was unpacked, do not remove the unit from the pallet. Transport it on the pallet to the installation site.
COUNTER LOCATION
Select location in well ventilated area, close to grounded electrical outlet. If possible do not place the unit close to hot and/or steaming machines.
720901120 - 2 -
Quantum Series Installation and Service Manual
INSTALLATION
SPECIFICATIONS
WATER SUPPLY
The Quantum Juice Dispensing machine is designed to dispense juice at a high flow rate. It is very important that the incoming water line is dedicated for the unit, or at least does not have other machines connected which could cause a water surge; i.e., a dishwashing machine.
NOTE: For increased cooling capacity the unit should be connected to a remote recirculating cooling unit. If the location is equipped with a dedicated beverage wa­ter supply system the juice dispenser should be connected to it.
NOTE: The water supply should be consistent with proper water quality standard (neutral ph of 7.0 to 8.0), and should not be connected to a water softener. The wa­ter cooling coil is Copper, and may be affected by poor water conditions (i.e. severe corrosion and pitting).
Water connections shall be sized, installed, and maintained according to Federal, State, and Local Laws.
ELECTRICAL
A minimum of 15 amps electrical service is needed for 120V power supply or 10 amps for 220V supply.
SPACE
The minimum clearance is: 4” (10.16cm) in back and 12” (30.48cm) on top and open to the front if sides are blocked off. If the sides are open then only 2” (5.08cm) is required in the back. Space between the bottom of the unit and the counter cannot be obstructed.
NOTE: Condenser air is drawn from the bottom and discharged out the back. Fail­ure to maintain clearance space will reduce capacity of the unit and cause prema­ture compressor failure.
CONNECTING WATER SUPPLY
1. Secure 3/8” (0.95cm) flexible hose to the unit water inlet. Make sure that the seal washer is used (hose and seal washer are included with the installation kit).
2. When securing flare nut use backup wrench on male side of the fitting (unit side) to prevent twisting of the copper tube inside the unit and/or possible damage to the water strainer/sole­noid. A water shut off outside the unit is recommended.
FILLING UNIT WITH WATER
To properly prime the unit with water, without air pockets in the system, push the dispensing switches simultaneously for a few seconds each. Repeat above until a steady flow of water is observed.
NOTE: Water splashing may occur during the purge cycle.
- 3 - 720901120
Quantum Series Installation and Service Manual
FLUSHING AND SANITIZING ON START UP
Follow standard sanitizing and flushing procedure.
PROGRAMMING PORTION CONTROL (OPTIONAL)
The portion control supplied with your orange juice dispenser has been programmed to pour 7, 12, and 16 ounce drinks. The “XL” size has also been programmed to pour 16 ounces. Should pour size adjustments be required, please follow the instructions below:
1. Simultaneously, press and hold “S” (small) and “XL” (extra large) push button switches on the Portion Control Module until the led “REFILL” light in the corner of the module starts blinking. Release the switches. The blinking led indicates the programming mode is active.
2. Place the cup under the white mixing valve nozzle and push the selected size button (small, medium, large, or extra large). Hold the button in until the cup fills to the desired portion, then release the button repeat the above procedure for the remaining sizes.
3. After programming all the drink sizes, press and release the “cancel/pour” switch to return the Portion Control to the operational mode. The blinking led light will go out.
If at a future date, it is decided to change the portion size of the drinks, the individual sizes can be adjusted by the above procedure. It is not necessary to reprogram every size.
The portion control has a full memory retention in case of a power failure.
CANCEL/POUR BUTTON
Push and release the cancel/pour button to stop the valve from dispensing.
Push and hold for a continuous pour.
720901120 - 4 -
Quantum Series Installation and Service Manual
CONCENTRATE
LOADING AND BRIXING
PLACING CONCENTRATE PRODUCTS ON DISPENSING PLATFORM
To engage the concentrate container, place it in the desired position and press down into bottle adapter opening on dispensing platform tray (inside the cabinet).
NOTE: Make sure o-ring seal on the container adapter is lubricated; otherwise, you may experience difficulties with container replacement.
NOTE: Concentrate in the containers must be completely thawed and be within the temperature range of 35 °F - 40°F (1.6°C - 4.4°C). Failing to supply concentrate inside the recommended temperature range, especially below 35°F (1.6°C), will cause an out of brix drink.
It is recommended the concentrate be thawed in a refrigerated (35°F - 40°F) (1.6 °C - 4.4°C) com- partment for 36 to 48 hours before use.
It is recommended that the thawed concentrate be thoroughly shaken before use.
CHANGING CONCENTRATE FLAVOR
1. Perform flush cycle
2. Move valve handle to “Dispense” position
3. Replace concentrate container
PUMP PRIMING
1. Follow instructions in paragraph “Placing Concentrate Products on the Dispensing Platform”
2. Close the door (or unit will not activate)
3. Depress the push button until concentrate appears at the dispensing nozzle.
BRIX SETTING
1. Make two (2) full clockwise turns of the corresponding brix knob from the “all the way out” po­sition (factory set). These two turns will bring you within one turn of proper brix setting. (Refer to brix table located on the inside of the refrigerated compartment door).
2. Dispense 1/2 cup of juice and discard.
3. Dispense 1/2 cup of juice and use refractometer to check brix level.
4. Clockwise rotation of the knob decreases brix level for example from 13% to 11.5%. Counter­clockwise will increase brix level for example from 11.5% to 13%.
If a brix problem is experienced, refer to troubleshooting guide.
- 5 - 720901120
Quantum Series Installation and Service Manual
CLEANING AND
SANITIZING
PROCEDURES
DAILY: SYSTEM FLUSH PROCEDURE
1. A 1 quart (0.95 liters) (32 fluid oz. minimum) empty container is needed. Place the empty con­tainer on the drip tray grill under the nozzle of the dispensing station to be flushed.
2. Open the cabinet door.
3. Choose the valve handle that corresponds with dispensing station to be flushed.
4. Move chosen handle from “dispense” position to the “flush” position.
5. Close the door.
6. Depress and hold push button corresponding with dispensing station to be flushed, until clear water is dispensed from the nozzle.
7. Move the handle to the “dispense” position.
8. Depress the push button for approximately 0.5 sec. and release. This will release water pres­sure from the pump system.
It is recommended to use one or more quarts of water to flush a single dispensing station.
DAILY: PART WASHING
1. Remove and wash dispensing nozzle, static mixer, splash plate, drip pan, bracket, and grille in a mild detergent solution. Rinse thoroughly.
WEEKLY: SANITIZING PROCEDURE
1. Remove juice concentrate container from unit and place in separate refrigerated compart­ment.
2. Perform flush procedure.
3. Fill a clean empty concentrate container with one quart of extremely hot tap water, approxi­mately 140°F (60°C) and place into unit. Run the hot water completely through unit into a large container. When complete remove concentrate container.
4. Remove nozzles and static mixers from unit and rinse under hot tap water to remove excess pulp.
5. Place nozzles and static mixers in separate container with 1 quart (0.95 liter) of sanitizing so­lution and agitate vigorously, using brush (P/N 07932) to remove any excess pulp or concen­trate (allow to soak for 2 minutes).
6. Clean bottle adaptor’s inlet area along with dispensing platform tray with brush and sanitizing solution to remove concentrate and pulp.
7. Clean valve mixing chambers with brush and sanitizing solution. (This is the cavity from which the nozzle is removed).
8. Replace nozzles and static mixers into proper location.
720901120 - 6 -
Quantum Series Installation and Service Manual
9. Fill a clean empty concentrate container with 2 quarts (1.9 liters) of sanitizing solution, place on dispensing platform, and insert bottle fitting into bottle adapter.
NOTE: Do not reuse the same sanitizing solution used to clean nozzles, static mix­ers, etc.
10. Place handle in dispense position and close door.
11. Run dispensing station for 90 seconds then stop; allow sanitizing solution to remain in lines for 5 minutes.
12. Dispense remaining sanitizing solution (approximately 90 seconds).
13. Replace sanitizing solution container with a concentrate container, and close door.
14. Depress and hold push buttons until juice appears at outlet of dispensing nozzle.
15. Dispense and discard two 8 oz. cups (236.6 ML) of juice.
NOTE: Wipe internal and external surfaces of cabinet with a clean damp cloth.
WEEKLY: CHECK BRIX SETTING
Tools: Hydrometer or Refractometer
1. Dispense required ounces of juice per brix testing device instructions.
2. Test concentrate to water ratio of dispensed juice per brix testing device instructions.
3. Clockwise rotation of knob decreases brix level (i.e. from 13% to 11.5%). Counterclockwise rotation of knob increases brix level (i.e. from 11.5% to 13%).
NOTE: If brix problem persists, refer to trouble shooting guide.
SEMI-ANNUAL: GENERAL CLEANING
1. Remove access port of Y-shaped water solenoid located on water inlet in lower cabinet, clean stainless steel strainer and reinstall.
2. Clean condenser fins.
3. Clean air inlet grille located in base of unit.
4. Clean lower cabinet interior.
5. Wipe fan blade clean.
YEARLY: REPLACE PUMP TUBING
Removal of Platform (see figure 1):
1. Remove concentrate container from the dispenser and place in a refrigerator.
2. Remove the product shelf.
3. Depress the button on the water line quick disconnect and lift the water line away from the platform.
4. Unplug the platform electrical connector at the inside rear of the cabinet.
5. Release the catch at the front of the platform by pulling the tab towards yourself with on finger.
- 7 - 720901120
Quantum Series Installation and Service Manual
6. Remove the nozzle and static mixers.
7. Carefully lift and pull the platform from the dispenser and place it in a clean and well lit area for service.
Replacement of Pump Hose (see figure 2):
1. Remove platform as described above in removal of platform instructions.
2. Remove the two white plastic hose clamps from the pump tube connections. Remove the two stainless steel concentrate delivery tubes from the hose ends.
3. Loosen and remove the four thumb screws from the pump body.
4. Remove the rear half (only) of the pump body to reveal the hose and rollers.
5. Remove the old hose from the pump body. If the rollers come out with the hose, place in back into the housing being sure to align the roller assembly shaft keyway to the motor shaft key so that the two interlock (see figure 3 for step by step pictorial instructions).
6. Firmly press the new hose into the pump body around the roller assembly, being sure to keep the protruding ends even with each other. Once the hose is in place, replace the outer half of the pump body. Hold the tubing in place inside pump housing with one hand, capture the lower part of the tubing with the outer housing, then proceed to capture the shaft of the roller assem­bly and push the housing straight onto the pump/motor portion of the assembly. Make sure to capture the hose within the body and not pinch it between the halves. Do not use any tool other than your finger tips to manipulate the hose into the housing or damage to the hose will result.
7. While holding the pump halves together by hand, reinsert the four thumb screws and tighten them in a criss-cross pattern until the two halves are pressed together.
8. Insert the two stainless tubes into the hose ends and fasten them with new clamps using pliers to tighten the clamps.
Replace platform in unit, reinstall nozzles and static mixers, connect water, install product shelf and concentrate, and reconnect power to unit.
720901120 - 8 -
Quantum Series Installation and Service Manual
- 9 - 720901120
Quantum Series Installation and Service Manual
720901120 - 10 -
Quantum Series Installation and Service Manual
TROUBLE-SHOOTING
GUIDE
The following pages contain trouble-shooting charts designed to aid an experienced serviceman in diagnosing any operating problems that may be experienced. In order to gain maximum benefit from the charts, please note:
1. Start at the beginning of the chart and supply the appropriate answer to each question.
2. Do not skip any section, unless instructed to do so. You may miss the solution to your prob­lem.
3. Evaluate the possible problem causes in the sequence in which they are presented. In gen­eral, they began with the most likely and/or easiest to check, and proceed to the less likely and/or more complicated.
4. If, after checking all indicated causes, the problem is not resolved, it is recommended that you try a second time. Evaluate symptoms carefully and modify your answers as necessary.
5. If you are unable to resolve a problem after several attempts, contact customer service de­partment at (1-800-238-3600) for assistance.
PROBLEM PROBABLE CAUSE REMEDY
Totally Inoperative No power to dispenser due
to tripped circuit breaker.
Loose or broken power sup-
ply connection inside dispenser.
No cooling Line voltage is not within
+10% of nameplate specifications causing compressor overload to trip
Both thermostats in OFF
position
Reset circuit breaker. Confirm that
breaker is correct size and no other equipment is operating on the same circuit. Also confirm that supply voltage is +10% of nameplate specifications.
Repair connection
Contact an electrician
Turn ON thermostats and recali-
brate the temperatures to 34oF
-40 oF (1.1 oC –4.5 oC).
Defective compressor over-
load or start capacitor
- 11 - 720901120
Replace
Quantum Series Installation and Service Manual
No cooling (con’t) Defective start relay located
on upper rear shelf inside dispenser
Compressor starts but
hums and trips overload
Compressor starts but does
not switch off of start winding
Compressor short cycles on
overload
Refrigerant leak Repair leak. Evacuate and
No water dispensed,
concentrate only.
No water to dispenser Restore water
There should be line voltage on the
black wire of the relay when there is line voltage present on the orange OR yellow wire. Replace relay if it fails this test.
Seized or shorted compressor,
replace.
Relay or compressor is defective.
Test and replace faulty item.
Excessively high discharge pres-
sure due to restricted con­denser or inoperative condenser fan motor
recharge system.
Water supply line inside
refrigerated cabinet dis­connected from pump platform
Water solenoid located on
pump platform clogged or defective
Main water solenoid/
strainer located at base of dispenser is clogged, binding or defective
Water supply pressure is
greater than 80 psi (5.5 bar)
Reconnect
Disassemble and clean solenoid.
Replace if necessary.
Remove and clean strainer. Con-
firm 28VDC is present at sole­noid during dispense. Confirm solenoid coil is not open. Disas­semble and clean solenoid.
Add external regulator and lower
pressure to 50 psi (3.5 bar)
720901120 - 12 -
Quantum Series Installation and Service Manual
No water dispensed,
concentrate only (con’t).
No water and no con­centrate, refrigeration is working
Freeze-up of water coil or
concentrate chamber
Unplug dispenser and allow 2-4
hours to thaw. Water or concen­trate thermostat set too low, recalibrate to 34oF -40 oF (1.1
o
C - 4.5 oC).
Defective water or concentrate thermostat, replace.
Refrigerant solenoid stuck open or not closing fully. Evacuate system, replace solenoid valve and recharge
Service switch located
Turn on switch under drip tray in OFF position
Door switch open Door switch must be closed in
order to operate pump. Check switch operation and replace if necessary
No water and no con­centrate, refrigeration is working
6.25 amp Fuse inside front electrical box blown
No output from Transformer
located on rear upper shelf
Defective voltage regulator
board (VRB) located inside front electrical box
Defective portion control
board
Replace with 6.25 amp, 250VAC
slow blow fuse and test
Confirm transformer output by
measuring for 26VAC at fuse. Replace transformer if neces­sary
Measure across the blue and black
wire located in the upper left corner of the board. There should be 28VDC present when the dispense button is pressed. Replace VRB if necessary
Disconnect wire harness from rear
of portion control, close door switch and short the orange and black wires together on the harness. If unit dispenses por­tion control board is defective. If it does not dispense the voltage regulator board is defective.
- 13 - 720901120
Quantum Series Installation and Service Manual
No concentrate dis-
pensed, water only
Excessive remnant left
in empty concen­trate pouch
Dispense tube not fully
engaged into recepta­cle on concentrate pouch
Dispense tube discon-
nected from mixing chamber
Slide block on pump in
open position
Switch on pump platform in
FLUSH position
Concentrate too cold, not
properly thawed
Defective pump motor Replace pump motor Concentrate pouch improp-
erly thawed
Refer to Concentrate Loading sec-
tion of this manual
Refer to Concentrate Loading sec-
tion of this manual
Close and lock the slide block.
Refer to Concentrate Loading section of this manual
Move switch to RUN position
Concentrate should be 34oF -40 oF
(1.1 oC –4.5 oC) prior to loading
Concentrate should be 34oF -40 oF
(1.1 oC –4.5 oC) prior to loading
Concentrate refill light
comes on prema­turely
Concentrate refill light
does not come on at all
Concentrate pouch and/or
dispense tube improp­erly installed
Concentrate pouch improp-
erly thawed
Concentrate pouch and/or
dispense tube improp­erly installed
Loose wiring Check wiring connections between
Bad VRB board Replace VRB board Bad pump motor Replace pump motor Pump improperly locked or
pump is open
Refer to Concentrate Loading sec-
tion of this manual
Concentrate should be 34oF -40 oF
(1.1 oC –4.5 oC) prior to load­ing.
Refer to concentrate loading sec-
tion of this manual
the pump motor and the VRB board
Close and lock Pump
Run/flush switch is in the
FLUSH position
720901120 - 14 -
Move switch to the RUN position
Quantum Series Installation and Service Manual
Concentrate refill light
does not come on at all (con’t)
Warm Drink Incoming water supply too
Improperly loaded tube Refer to concentrate loading sec-
Bad VRB board Replace VRB board Bad portion control Replace portion control
warm
Ambient air too warm Relocate dispenser Excessive demand on dis-
penser
Dirty condenser coil Clean condenser coil Inoperative condenser fan Replace condenser fan motor Defective water thermostat Replace thermostat Loss of refrigerant charge
due to leak in system
tion of this manual
Optimum performance is achieved
when the dispenser utilizes water from a pre-cooler
Add water pre-cooler or second
dispenser
Repair leak and recharge system
Water continuously drips
from nozzle when in OFF mode
No Flush Cycle Run/Flush switch on pump
Concentrate warm,
water cold
Main water solenoid at base
of unit or water solenoid on pump platform not shutting off tightly
platform in Run mode
Defective Run/Flush switch
on pump platform (con­centrate continues to dispense while in Flush mode)
Concentrate thermostat is
turned off or not cali­brated properly
Concentrate thermostat defective (stuck open)
Defective start relay located
on upper rear shelf inside dispenser
Clean solenoid(s), replace parts as
necessary
Move switch to Flush position
Replace Run/Flush switch
Calibrate to be 34oF -40 oF (1.1 oC
–4.5 oC)
Replace thermostat and calibrate
to 34oF -40 oF (1.1 oC –4.5 oC)
There should be line voltage on the
black wire of the relay when there is line voltage present on the orange OR yellow wire. Replace relay if it fails this test.
- 15 - 720901120
Quantum Series Installation and Service Manual
Concentrate warm,
water cold (con’t)
Brix Problem Water supply pressure too
Loss of refrigerant charge
due to leak in system
low, less than 20 psi (1.4 bar) flowing or water pressure fluctuates sharply
Water flow control binding
or spring is defective
Improperly thawed concen-
trate. Brix changes as the concentrate temper­ature changes (concen­trate becomes thinner as temperature rises)
Check that the rollers on the
pump are spinning freely with no tube in place
Repair leak and recharge system
Correct water supply problem to
ensure a constant 40 psi (3 bar) flowing to the dispenser
Clean and/or replace parts as nec-
essary
Concentrate should 34oF -40 oF
(1.1 oC –4.5 oC) prior to loading
If they are sticky or locked up see
platform removal and cleaning procedure.
Pump Inoperative Pump motor defective 28VDC should be present at pump
motor during dispense. If volt­age is present and motor does not start, replace pump motor
No power to transformer or
no 28VAC output from transformer
Defective voltage regulator
board (VRB) located inside front electrical box
Defective portion control
board
Confirm transformer has line volt-
age present on primary side. If no 28VAC output from the sec­ondary replace transformer
Measure across the blue and black
wire located in the upper left corner of the board. There should be 28VDC present when the dispense button is pressed. Replace VRB if necessary
Disconnect wire harness from rear
of portion control, close door switch and short the orange and black wires together on the harness. If unit dispenses por­tion control board is defective. If it does not dispense the voltage regulator board is defective.
720901120 - 16 -
Quantum Series Installation and Service Manual
Machine continues to
dispense after dis­pense button is released or dis­penses without operator input
Sold Out light illumi-
nates when concen­trate no longer passes through the pump.
Portion control pad stuck in
on position
Relay on voltage regulator
board (VRB) stuck on.
The concentrate is improp-
erly thawed. The tem­perature is not maintained between 34×F - 40×F(1.1-4.5×C)
Disconnect the wire harness from
the rear of the portion control and close the door. If unit does not dispense on its own the por­tion control is bad (stuck on)
Disconnect the 4-wire harness
from the lower right corner of the VRB. If the unit continues to dispense on its own the VRB is defective (relay stuck on)
Assure proper thawing procedures
have been followed per the Minute Maid company instruc­tions.
Check that McDonald’s walk-in
cooler temperature is on the proper set point.
Check the dispenser cabinet tem-
perature is at 34×F - 40×F(1.1-
4.5×C).
High Brix readings result in
a poor, pulsating/splash­ing dispense, erratic pump amp draw, and consequently erratic sold-out indications.
Check drink brix in procedure
described on equipment P.M. card using the hydrometer pro­vided.
Check the drink flow rate under
normal operating conditions. The dispenser should pour a drink at a flow rate of approxi­mately 1.5 oz. Per second or greater. If the flow rate is less, a check described in the Sold Out section should be completed.
- 17 - 720901120
Quantum Series Installation and Service Manual
Sold Out light illumi-
nates when concen­trate no longer passes through the pump.(con’t)
Improper loading proce-
dures will usually result in low brix conditions and thus erratic sold out indications.
Tube has been stretched
through pump when it was loaded. Pouch may not be seated correctly.
Check that the rollers on the
pump are spinning freely with no tube in place.
Check that the pouch of juice is
properly loaded in the pouch holder. Tube fitting should be located at the bottom of the pouch holder and the tube should be approximately cen­tered in the bottom portion of the opening of the holder.
Check that the tube is correctly
loaded in the pump and the pump is fully locked (top and bottom slide pins should be fully engaged into the pump body).
Adjust pouch. If pouch is loaded
correctly there should be ample tube to reach the mixing cham­bers without stretching the tube.
If the rollers are sticky or locked up
see the platform removal and cleaning procedure.
Sold Out light fails to
reset itself after door is opened and closed (Sold Out light stays illumi­nated)
Check the operation of the
reset switch located at the bottom left hand side of the door.
Adjust Switch.
720901120 - 18 -