Ikelite EOS 10D User Manual

Ikelite SLR-DC Housing
Strobe Mount
Rubber Handle
Quick-Release Strobe Mount
Gear Sleeve Drive Gear
Zoom Control
Lid Snap
M
ode
D
ial
Lens Release
Main Dial
M
eter/Flash
D
rive Mode
A
F/WB Mode
Illuminator
Lid Snap
Shutter Release
AE/FL Lock
Port Lock
A
luminum Tray
Port
Opening
Quick Release Button
External Strobe Connector and Waterproof Cap
Viewfinder Po r t
Shutter Release
[D] Direction [E] Playback [F] Erase
[G] On/Off [H] Access [I] AF Point
A
B
C
D
E
F
G
H
I
K
J
L
Lens Release
Zoom
AE/FE Lock
[A] Menu [B] Info [C] Jump
[J] Set [K] Quick Control Dial [L] eTTL Mode/Compensation
Camera Tray
Camera Mounting Bolt
Gear Sleeve
Port O'ring
Optional Port
Lid Snap
Shutter Release
AE/AF Lock
Back O’ring
Main Dial
Lift
Push For ward
Lid Snap Lock
Springs
Groove
Rubber Strips
Lens Zoom Grip
Springs
instruction manual
#6871.11 for Canon EOS 10D
Congratulations on your purchase of an Ikelite Digital Camera Housing. Ikelite has over 40 years of experience in the underwater photographic and lighting market. Our products are designed and built in the USA by Ikelite for both the professional and amateur photographer. The clear housing permits instant visual inspection of the camera and all sealing surfaces as well as complete monitoring of controls and camera LCD screens. Ikelite Digital Housings are slightly negative in salt water for stability. This housing has been water pressure tested at the factory. Housing is pressure tested to 200’ (60m).
FRONT VIEW
BACK VIEW
2
SIDE
VIEW
LLuubbrriiccaanntts
1. Ikelite provides silicone lubricant with the housing. We recommend that you use only Ikelite lubricant as some other brands may cause the o’ring to swell and not seal properly.
2. Use only enough lubricant to lightly cover control shafts and o’rings. Wipe off any excess lubricant with a clean cloth. Lubricant is not a sealant, it is used to reduce friction. Excessive lubricant can collect sand and dirt which may interfere with proper sealing.
CCAAUUTTIIOON
NNeevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt iinnggrreeddiieenntt ccaan ccaauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk.
N
s
3
.
n
OOppeenniinngg tthhee HHoouussiinng
1. Lid Snaps have a
LLoocck
g
k
. To open, push Lid Snap Lock forward and lift as shown. Keep pressure on the Lid Snap so it does not fly open quickly.
Some lid snaps have a lot of spring tension once they go over center, have a firm grip on the lid snap. Lid Snaps may be opened one at a time.
ZZoooomm CCllaammp
IInnssttaalllliinngg tthhee ZZoooomm CCllaammp
p
p
The two halves of the Zoom Clamp are held together by springs. This allows the Zoom Clamp to be stretched to fit over the zoom grip on different diameter lenses. The Zoom Clamp should fit tight around the lenses zoom grip so that it does not slip when using it to rotate the camera’s zoom ring. If the Clamp is loose, adhere the thin black rubber strips to the inside of each half of the Zoom Clamp as shown above. The Zoom Clamp has two extended ears with grooves. These grooves accept the Ribs on Gear Sleeve.
4
Gear Sleeve
Rib
Gear Teeth
Camera Tray
O‘ring
Mounting Bolt
Strobe ID Switch
IInnssttaalllliinngg tthhee CCaammeerra
E
xternal Strobe Connector
Waterproof Cap
O
'ring
Housing Back
Camera
H
ot Shoe
Connector
Front of Camera/Tray
DS50 / DS51 / DS80
DS125 / DS200
a
1. Remove the back from the housing. The
ounting tray for the
m camera is secured to the housing back. Position the camera and lens on the tray and secure it with
he mounting bolt which
t threads into the camera’s tripod socket.
NNOOTTEE:
:
trobe ID Switch
S located on bottom of camera tray.
SSeettttiinngg tthhee CCoonnvveerrssiioonn CCiirrccuuiittrryy SSttrroobbee IIDD SSwwiittcchh..
On the bottom of the camera tray is a switch for setting the DS Substrobe ID. Set the switch to the Model of DS Substrobe being used, SD125 or DS51.
• When using dual strobes of different models such as a DS51 and
a DS125, set the ID switch to DS51.
FFllaasshh CCoonnnneeccttiioonn ffoorr EExxtteerrnnaall SSttrroobbees
s
When using an external strobe connect the housings Hot Shoe Connector, slide the connector into the hot shoe of the camera from the back of the camera as shown. Slide the connector forward until
t stops. This
i can be done after the camera is secured with the mounting
olt.
b
CCaauuttiioonn:
:
Do not remove the External Strobe Connector’s waterproof cap unless an external sync cord is going to be plugged in.
IInnssttaalllliinngg CCaammeerraa iinn HHoouussiinng
g
Before installing the camera, pull out on the controls in the front section of the housing. This will allow the camera to slide in easier. Once the camera is installed and the lid snaps have been closed, return the controls to their operating position.
5
CClloossiinngg tthhee HHoouussiinng
g
housing back
1. Place housing face down in your lap.
2. Check to see that there is an o’ring on the housing back and that it is clean and in its proper location.
3. Guide the back onto the housing. The o’ring should touch the housing all the way around. There should be an even gap all the way
housing
around between the housing and the housing back.
4. Lift the lid snaps so they are extended and place the lid snap
housing back
into the hook on the housing back. To close the housing push
5. down on the lid snaps until they snap into place . Lid snaps on opposite sides of the housing should be closed at the
DDoouubbllee cchheecck
same time. Be sure they are down far enough to engage the lock.
k
- Once the housing is
even gap all 4 sides
housing
closed, check the o’ring seal. Check the gap between the housing back and the housing, it should be even all the way around.
Look through the clear plastic back at the o’ring. You should see a
darkened area where the o’ring is compressed against the housing back. If you do not see an even black compression seal all the way around the back, open the lid snaps, reseat the housing back and close the lid snaps. Visually check the seal again.
7
o’ring
o’
ring
6
IInnssttaalllliinngg tthhee GGeeaarr SSlleeeevve
e
It is easiest to install the gear sleeve and port with the housing laying on it’s back with the camera lens pointing up.
Position the clear plastic Gear Sleeve with the gear teeth pointed toward the housing. The Gear Sleeve slides over the lens and the Gear Sleeve’s ribs slide into the grooves on the extended ears of the Zoom Clamp. The gear teeth on the Gear Sleeve should mesh with the drive gear in the port opening on the housing. (See front view of housing)
IInnssttaalllliinngg tthhee PPoorrt
There are two port locks on the front of the housing.
t
Port Lock Release Button
(See housing front) Each port lock has a Release
Locked Position
Button, lift the release button and slide each Port Lock away from the port opening. In the unlocked position the Release Button will remain in the up position as shown.
Unlocked Position
Pull Back to Disengage Port
8
Lift Release Button to Unlock
IInnssttaalllliinngg tthhee PPoorrtt ccoonntt.
F
-1-2-3
M
••••
MODE
-2
-1 +1 +2
TTL
Red LEDs (Compensation)
Mode &
Compensation
Buttons
Manual Mode Yellow LED
TTL Mode
33
ikelite
SubstrobeSubstrobe
MOD-NC
To prepare the port for installation, remove the port o’ring and lightly lubricate it. The port seal is a side-to-side seal and requires the o’ring to be lightly lubricated for easy installation. Put a small amount of lubricant on your fingers and draw the o’ring through your fingers to lightly lubricate it. Do not stretch the o’ring. Check that the lip of the port where the o’ring fits
nd the sealing surface on the housing are clean. Place the port,
a with o’ring into the housing’s port opening. Press down on the
ort firmly and evenly until you feel the port slide into place.
p Continue to push down on the port and push each port lock
orward until it clicks into place. It may help to slightly rotate
f the port as you push in on the port lock. When the port lock clicks into place the Release Button will drop down against the port lock.
heck around the perimeter of the port seal to see that the
C o’ring is properly sealed and not extruded.
.
UUssiinngg EExxtteerrnnaall SSttrroobbees
his housing has Conversion Circuitry built into the camera
T tray. When used with Ikelite DS Substrobes the Conversion
ircuitry provides real Canon eTTL flash exposure with over and
C under-exposure compensation of two f-stops in half-stop
ncrements.
i
The Consversion Circuitry also offers Manual exposure control with 3 1/2 f-stops of under-exposure control in 1/2 stop increments.
The Conversion Circuitry is powered by the Ikelite DS Substrobe when connected to the housing with the #4103.51 single or #4103.52 dual sync cord.
See page 12 for DS Substrobe compatibility with the Conversion Circuitry.
s
TToo RReemmoovvee PPoorrt
To remove the port lift up on each Release Button and slide the port lock away from the port.
PPoorrtt SSeeaall IInnssiiddee VViieew
If the port is installed before the camera is inserted into the housing, look on the inside of the housings at the port seal. Check to see that the o’ring is properly sealed as shown in figure 1 and not extruded as shown in figure 2.
UUssiinngg EExxtteerrnnaall SSttrroobbeess CCoonntt.
UUssiinngg tthhee CCoonnvveerrssiioonn CCiirrccuuiittrryy
•• MMooddee aanndd CCoommppeennssaattiioonn BBuuttttoonns The Conversion Circuitry default is set to TTL. To switch between TTL and Manual Modes depress both Mode Buttons at the same time and keep then depressed until you see the desired Yellow LED Mode illuminate.
•• TTTTLL MMoodde illuminated). TTL Mode is the default setting. When the DS Substrobe is powered ON the Yellow TTL LED will illuminate. None of the Red LEDs will illuminate. This indicates that NO (+) plus or (-) minus compensation is selected. Depress the Mode buttons to select +/- compensation. Note that the TTL +/­compensation values are in the yellow bar with the heading TTL.
•• MMaannuuaall MMoodde the M is illuminated). When the Manual Mode is selected the Red LED directly below the F (full power) will illuminate. Note that the Manual minus (-) compensation values are in the black bar with the heading M.
t
w
Fig. 1
Fig. 2
9
.
((SSeett DDSS SSuubbssttrrbbooee ttoo TTTTLL mmooddee))
s
e
(indicated when the Yellow LED directly below TTL is
e
(indicated when the Yellow LED directly below
((SSeett DDSS SSuubbssttrrbbooee ttoo TTTTLL mmooddee))
11
NNOOTTEE:
:
If the camera is busy with a function such as displaying a photograph on the LCD panel the Conversion Circuitry cannot be accessed to make changes. Wait until the camera has finished with any activity before making changes through the Conversion Circuitry.
10
NNOOTTEE:: DDSS SSuubbssttrroobbee UUpp--ddaattee mmaayy bbee rreeqquuiirreedd.
DDSS5500 SSuubbssttrroobbees
• DS50 SubStrobes with a Serial Number below 63,850 can not be updated to operate with the eTTL Conversion Circuitry.
• DS50 SubStrobes with a Serial Number between 63,850 and 69,999 operate with the eTTL Conversion Circuitry, but require update to provide optimum performance.
• DS50 Substrobe with a Serial Number of 70,000 or higher or with one of the two following labels in the battery compartment provide optimum performance with the eTTL Conversion Circuitry.
DDSS112255 SSuubbssttrroobbees
• DS125 Substrobes with a Serial Number below 2,500 must be updated to operate correctly with the eTTL Conversion Circuitry.
• DS125 Substrobes with a Serial Number between 2,501 and 4,900 operate with the eTTL Conversion Circuitry but require update to provide optimum performance.
• DS125 Substrobe with a Serial Number of 5,000 or higher or with one of the two following labels in the battery compartment provide optimum performance with the eTTL Conversion Circuitry.
FFoorr SSuubbssttrroobbee UUpp--DDaattee: Contact Ikelite for information.
s
s
:
serial number
12
serial number
.
Measure
UUssiinngg EExxtteerrnnaall SSttrroobbeess CCoonntt.
.
UUssiinngg IIkkeelliittee NNoonn--DDSS SSuubbssttrroobbeess ((SSuubbssttrroobbee 5500,, 110000AA, 220000,, 440000)) wwiitthh tthhiiss HHoouussiinngg.
The Conversion Circuitry is automatically disabled when used
ith a Non-DS Substrobe. These Substrobes can be used in their
w manual mode utilizing any power settings provided on the Substrobe.
UUssiinngg NNoonn IIkkeelliittee SSttrroobbeess wwiitthh tthhiiss HHoouussiinngg.
The Conversion Circuitry is automatically disabled when used with a Non Ikelite Strobe. These strobes can be used in their manual mode utilizing any power settings provided on the strobe.
.
.
SSttrroobbee AArrmms
his housing offers two types of arm mounting systems. The
,
T top of the rubber handles utilize Ikelite’s Quick-Release Arm,
vailable with the SA-100R Arm system.
a The bottom of the rubber handles have a wing nut that accepts
the Ikelite Tray Mount. The Tray Mount comes with the Ikelite SA-125 Arm system and the SA-100T Arm system.
s
13
PPrree--DDiivvee YYoouurr SSyysstteem
It is recommended that you take the complete system into a swimming pool before use in open water. This will give you a chance to become familiar with the handling and operation of your housing and strobe(s).
OOppttiioonnaall AAcccceessssoorriiees
LLeeaadd WWeeiigghhtt ##00990066..558
The buoyancy of the system will depend on the size and number of strobes used as well as the weight of the camera. Ideally the system should be slightly negative in the environment in which it will be used. If you need to add weight to the system, an optional lead weight is available. To add the lead weight remove the (2) screws from the bottom of the aluminum tray. Place the lead weight into the pocket of the aluminum tray and reattach.
IIkkeelliittee LLuubbee ##00118844..1
PPoorrtt OO’’rriinngg ##0011005
HHoouussiinngg BBaacckk OO’’rriinngg ##00113322..661
While both the Port and Back o’rings should last quite some time it is best to carry a spare in case one becomes damaged or lost.
SSttoorriinngg tthhee HHoouussiinng
When the housing is going to be stored for a prolonged period it should be soaked in a mild soap solution, rinsed and dried thoroughly. Remove the back and port from the housing. Remove the back and port o’rings, lightly lubricate them and place them in a plastic zip-lock bag. Place the plastic bag inside the housing for storage. Operate the push buttons periodically.
m
s
8
1
5
1
g
15
14
PPoorrtt IInnffoorrmmaattiioon
While we have included a list of our ports and a short list of Canon Lenses and port recommendations we suggest visiting our web site for the latest information on lenses and port recommendations.
CChhoooossiinngg aa PPoorrt
DDOOMMEE PPOORRT
#5503 ........Wide angle 28mm to 17mm
#5503.20 ..Nikon 18 & 20mmD lenses #5503.50 #5503.55 #5503.80 .. #5503.81 #5503.85 ..Lens 12.7-15.2cm (5-6")
Some zoom lenses may require the addition of a +diopter close-up lens. (Available from camera store).
T
or lens up to 7.6cm (3") in length
..Lens 7.6-10.1cm (3-4")
....Lens 8.9-11.4cm (3.5-4.5")
Lens 10.1-12.7cm (4-5") Nikkor 28-105mm lens only
....
n
•With the lens on the camera extended to full length, measure from front of camera to face of lens.
•Select the appropriate port based on the lens type and length.
•Maximum lens diameter accommodated is
8.4cm (3.3")
•Maximum lens diameter when using zoom or focus clamp 7.1cm (2.8")
t
SUPERWIDE DOME PORT
Superwide lens 110° to 170°. Not compatible with the SLR-MD housing due to vignetting.
#5503.15 ........Lens up to 6.3cm (2.5")
16
PPoorrttss CCoonnttiinnuueed
d
FLAT PORT
or standard, macro, and telephoto lenses.
F
ue to refraction flat ports reduce the angle-of -coverage of a lens
D and at the same time enlarge the image. This makes the flat port ideal when using standard, macro or zoom lenses to shoot small subjects. Note that if a port is long enough to accommodate the full length of a 1:1 macro lens, the lens may vignette when used at infinity. If access to the lens' full range is desired, then select a dome port instead.
FLAT PORT
#5501 . . . . . Lens up to 6.3cm (2.5")
#5502 . . . . . Lens 6.3-8.9cm (2.5-3.5")
5502.41 . . Lens 7.9-10.4cm (3.1-4.125")
#
5505 . . . . . Lens 8.9-11.4cm (3.5-4.5")
# #5505.45 . . Lens 10.4-13cm (4.1-5.125") #5505.5 . . . Lens 11.4-14cm (4.5-5.5") #5505.58 . . Lens 13-15.5cm (5.1-6.125")
FLAT PORT WITH FOCUS
For long lenses whose focus collar extends beyond the housing focus. Telephoto lenses longer than 135mm are not recommended.
#5506 . . . Lens 8.9-11.4cm (3.5-4.5") #5506.5 . Lens 11.4-14cm (4.5-5.5")
5507 . . . . Lens 14-16.5cm (5.5-6.5")
5508 . . . . Lens 16.5-19cm (6.5-7.5")
5508.05 . Nikor 105mm lens only
17
LLeennss && PPoorrtt RReeccoommmmeennddaattiioonns
CCaannoonn LLeennsseess............................................................................................DDoommee................................FFllaatt PPoorrtt................................FFllaatt PPoorrtt ww//FFooccuus
14mm EF 1:2.8 ..............................5503 (1)
15mm Fisheye ..............................5503.15
20mm ............................................5503
24mm ............................................5503
28mm ............................................5503 ............5501
35mm ............................................5503 ............5501
50mm Macro 1:2.8........................5503.50 ........5505
100mm Macro ..............................NR................5505.5
100mm EF Macro 1:2.8................NR................5505.58(4)
100mm USM Macro 1:2.8............NR................5505.45 ............5508.45
16-35mm USM ..............................5503.55(2)
17-35 Ultrasonic ............................5503.50 (2)
17-40mm USM..............................5503.50(2)
18-55 EF-S ......................................5503
*20-35mm ......................................5503.50
*20-35 Ultrasonic ..........................5503 (2)
*22-55 Ultrasonic ..........................5503.50(2)
*24-85mm......................................5503.50
*28-70mm......................................5503.85 (3)
*28-80mm ....................................5503.50
*28-80mm USM............................5503.50(2)
28-105mm EF USM II ..................5503.55(2)
*28-105mm USM ..........................5503.80(2)
*35-80mm......................................5503 ............5502
*35-135mm ....................................5503.80
SSiiggmmaa AAFF ((CCaannoonn))................................................DDoommee....................FFllaatt PPoorrt
*28-105mm f/2.8-4........................5503.80(2)
(*) Zoom lenses that do not focus to 12” require a +4 diopter close-up lens be added to the lens when used underwater behind a dome port. (1) Port shade may have to be removed to avoid vignetting. (2) Lens requires special zoom clamps and focus sleeve #5509.28. (3) Lens diameter does not allow zoom operation in the housing. (4) Auto or Manual focus must be selected before closing the housing. Requires special zoom clamp and focus sleeve #5509.28 for manual focus.
s
t
18
s
MMaaiinntteennaanncce
e
The Ikelite Housing should be given the same care and attention as your other photographic equipment. In addition to normal maintenance we recommend that the housing be returned to Ikelite periodically to be checked and pressure tested.
DDoo NNoot
t
1.
leave the camera and housing in direct sunlight for
prolonged periods. Heat may damage the camera.
DDoo NNoot
2.
3. Before using the housing, always check the tightness of the
t
ship the camera in the housing.
ssccrreew
w
in each control knob.
Check each
ccoonnttrrooll ggllaannd
d
penetrating the housing to make sure
sseet
they are tight. There is a slight chance that either could vibrate loose during travel.
4. Keep the back and port o’ring clean and lightly lubricated. To lubricate remove the o’ring from the back. Put a small amount of lkelite lubricant on your fingers. Draw the o’ring through your fingers to apply a light coating of lubricant. Only apply enough lubricant to make the o’ring feel slick.
tthhee oo’’rriinng
g
. This light coating of lubricant will help to keep the
DDoo NNoott ssttrreettcch
h
o’ring from drying out and will help to show a dark sealing line when the housing back is properly sealed.
5. Keep the area where the o’ring fits and the sealing surface clean.
6. Rinse the housing exterior thoroughly in fresh water after each salt water use. Depress push buttons several times during rinse. Dry with a soft cloth. Dry port to eliminate water spotting. After several uses in salt water soak the housing in a mild soap solution, rinse and dry.
CCAAUUTTIIOONN::
iinnggrreeddiieenntt ccaann ccaauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk.
NNeevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt
.
19
CCoonnttrrooll MMaaiinntteennaanncce
e
Ikelite controls are designed to provide years of reliable service with minimal maintenance.
1. Push button controls require no maintenance other than rinsing in fresh water after saltwater use. If a push button control becomes difficult to push or if it sticks when depressed, soak the housing in luke warm fresh water. After a few minutes operate the push button. If this does not correct the problem, return the housing to Ikelite for maintenance.
t
2. Some of the controls have long shafts. These controls can be
lubricate shaft
housing
pull out to expose shaft
pulled out, exposing the shaft (see drawing). To lubricate the control, gently pull on the knob until the stainless steel shaft is exposed. Lightly lubricate the shaft, then move the shaft in and out several times. This will lubricate the x’ring in the Ikelite control gland. This should be done before using the housing after a prolonged storage period, or once a week when the housing is in use.
20
3. Some of the controls have a short shaft and cannot be pulled out exposing the shaft for lubrication. In the unlikely event one
f these controls sticks or becomes difficult to operate you can
o remove the control from the housing and lubricate it, or return the housing to Ikelite for maintenance. To remove the control, loosen the set screw in the knob (allen wrench required);
emove the knob. If there is salt or dirt build-up on the exposed
r control shaft, clean the shaft. Open the housing and gently slide
he control shaft out of the control gland. Clean and lightly
t lubricate the shaft, including the end of the shaft. Slide the
haft back into the control gland and gently slide it back and
s forth a few times without fully removing the shaft from the gland. Replace the knob, NOTE the flat area on the shaft, the set screw in the knob should tighten down against the flat area
n the control so the knob does not turn on the shaft.
o
control shaft
Flat
Tighten set screw down
against this area when
replacing the knob.
housing
Lubricate end of shaft before reinserting into gland
gland
Loosen set screw (allen wrench required)
GGeenneerraall TTiipps
1. You should completely assemble and test your set-up in a swimming pool before using it in openwater.
2. It is a good idea to start each photo dive with a fully charged battery(s) in the camera and strobes.
3. As soon as you enter the water, take a moment and check the housing to see that it is properly sealed.
4. Next, check to see if there are any bubbles on the face of the port. If there are, take your finger and remove them. If there are bubbles on the lens port they can produce soft focus spots in your photographs.
5. Set Image Resolution to the Highest JPG format available or
AW. Higher resolution setting are required for printing. High
R resolution images can easily be reduced in size with software and retain their original quality. A Low resolution image can be enlarged with software but much of the quality will be lost.
6. Digital images are usually transferred to the computer where their appearance can be fine tuned. Many of the image manipulation programs make you think you can magically correct any image taken and make a good picture. One thing to be aware of is that if an image is overexposed that some of the color information in the file is missing. If the color is missing you cannot adjust it. If images are underexposed the color and detail may be there, it is just dark, and you can adjust it to some degree. So if you error in exposure it is better to have the image slightly underexposed than overexposed.
s
21
PPhhoottoo TTiipps
1. The number one rule in underwater photography is eliminate as much water between camera and subject as possible. Get as close as you can to the subject, then use the zoom. If you are using flash, subjects beyond 6 feet (1.8m)will not have much color.
2. Digital cameras have a slight lag time between when you press the shutter release button and the camera actually takes the picture. It only takes a slight amount of pressure to trip the shutter, if the shutter doesn’t trip immediately don’t push down harder on the shutter control as you may damage the camera. Hold the camera steady a second or two after pressing the shutter release button.
3. Do not shoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph. Shoot subjects straight on or shoot up at a slight angle using the blue water as a contrasting background.
4. Underwater flash is used to restore the warmer colors filtered out by the water as well as to illuminate the subject.
5. For balanced lighting meter the background and set the camera aperture accordingly. Use TTL, adjust the strobe’s power settings, or move the strobe closer or farther away to properly expose the subject with the chosen camera aperture.
s
22
IIkkeelliittee LLiimmiitteedd WWaarrrraanntty
All Ikelite products are warranted against any manufacturing defects for a period of one (1) year from the date of purchase. Defective products should be returned prepaid to Ikelite. Ikelite will, at its discretion, repair or replace such products, and will return to customer prepaid. All other claims, of any nature, including but not limited to bulb failure are not covered. Except as mentioned above, no other warranty expressed or implied, applies to this Ikelite product.
RReettuurrnniinngg PPrroodduuccttss ffoorr SSeerrvviicce
Ikelite is most interested in preforming any service to assure that
all products perform as intended. For repair or service, return the product to the address below with your name, address, phone number and a brief description of the problem. Evidence of purchase date must be provided to obtain warranty service.
IIkkeelliittee UUnnddeerrwwaatteerr SSyysstteemms
IInnddiiaannaappoolliiss,, IINN 4466220088 UUSSA
eemmaaiill:: iikkeelliittee@@iikkeelliittee..ccoom
y
e
5500 WW 3333rrdd SSttrreeeet
331177--992233--4455223
wwwwww..iikkeelliittee..ccoom
3
s
t
A
m
m
23
DDiiggiittaall 66887711..1111--0022--33--006
6
Loading...