IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
IMPOR
SÓLO P
IMPOR
POUR UTILISA
.
CANOPY RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-866-644-2449.
In Canada, for assistance, installation and service, call: 1-866-664-2449.
CAMPANA DE COCINA CON ESCUDETE DE
MONTAJE EN LA PARED, DE 30" (76,2 CM)
Instrucciones de instalación y Manual de uso y cuidado
Pour des questions à propos des caractéristiques, du fonctionnement/rendement, des pièces, des accessoires
Au Canada, pour assistance, installation ou service, composez le : 1-866-664-2449.
ou du service, composez le :1-866-644-2449.
HOTTE DE CUISINIÈRE À MONTAGE
MURAL DE 30" (76,2 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Si tiene preguntas respecto a las características, funcionamiento, rendimiento, partes, accesorios
En Canadá, para obtener asistencia, instalación y servicio, llame al: 1-866-664-2449.
o servicio técnico, llame al: 1-866-644-2449.
Table of Contents/Índice/Table des matières ...........................2
For warranty concerns, do not take the appliance back to the store. Please contact us in U.S.A. or Canada at 1-866-664-2449.
This product features a Limited Warranty - See the “Warranty” section for complete details. IKEA® appliances carry a 5-year warranty
(excludes LAGAN family - see warranty for coverage details).
NOTE: Proof of Purchase is required to obtain warranty service.
Si tiene dudas acerca de la garantía, no devuelva el aparato a la tienda. Póngase en contacto con nosotros en los EE.UU.
o en Canadá al 1-866-664-2449.
Este producto tiene una garantía limitada - Consulte la sección “Garantía” para obtener todos los detalles. Los aparatos IKEA® tienen
una garantía de 5 años (excluyendo los de la familia LAGAN - consulte la garantía para ver los detalles acerca de la cobertura).
NOTA: Se requiere la prueba de compra para obtener servicio bajo la garantía.
Pour toute question concernant l’application de la garantie, ne pas rapporter l’appareil au magasin. Veuillez nous contacter
aux É.-U. ou au Canada au 1-866-664-2449.
Ce produit est couvert par une garantie limitée – Voir la section “Garantie” pour des détails complets. Les appareils IKEA®
sont couverts par une garantie de 5 ans (hormis les appareils de la série LAGAN - voir la garantie pour des détails concernant
les modalités de garantie).
REMARQUE : Une preuve d’achat est obligatoire pour obtenir l’application de la garantie.
Y.
TANTE: LEA Y GUARDE ESTAS INSTRUCCIONES.
ARA USO RESIDENCIAL.
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
TION RÉSIDENTIELLE UNIQUEMENT
LIB0119766A/W10836384B
TABLE OF CONTENTS
RANGE HOOD SAFETY .................................................................3
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
■ Level
■ Drill with 1
and 7/64" (2.75 mm) drill bits
■ Pencil
■ Wire stripper or utility knife
■ Tape measure or ruler
■ Pliers
■ Caulking gun and weatherproof caulking compound
■ Vent clamps
■ Jigsaw or keyhole saw
■ Flat-blade screwdriver
■ Metal snips
■ Phillips screwdriver
■ Metric hex key set
Parts Needed
■ Home power supply cable
1
■
/2" (12.7 mm) UL listed or CSA approved strain relief
■ 3 UL listed wire connectors
For Vented Installations, You Will Also Need:
■ 1 wall or roof cap
■ Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
■ Charcoal Filter Kit Part Number W10412939 for non-vented
(recirculating) installations only. See the “Assistance or
Service” section to order.
■ 6" (15.2 cm) diameter round metal vent duct—
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
■ Hood canopy assembly with ventilator and LED lights
installed
■ Vent transition with back draft dampers installed
■ Metal grease filter(s)
■ Vent cover support bracket
■ Mounting template
■ Air deflector with extensions (for non-vented installations)
■ 2-piece vent cover
■ 2 - 2.9 x 6.5 mm screws (T10 drive)
■ 6 - 3.5 x 6.5 mm screws (T10 drive )
■ 2 - 3.5 x 9.5 mm screws (Phillips)
■ 4 - 4.2 x 8 mm screw (T20
■ 6 - 5 x 45 mm mounting screws (#2 Phillips drive)
■ 6 - 8 x 40 mm wall anchors (masonry)
1
/4" (3.0 cm), 3/8" (9.5 mm), 1/8" (4.8 mm),
®†
drive)
■ 2 - Flat washers
■ T10 Torx
■ T20
®†
adapter
®
Torx® adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops
with a maximum total rating of 60,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or wall.
For non-vented (recirculating) Installation, see “For
Non-vented (recirculating) Installation Only” in “Connect Vent
System” section. Charcoal Filter Kit Part Number W10412939
is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will
be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A
or latest edition, or with local codes.
* For non-vented (recirculating) installations only
** For vented installations only
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
2"
(51 mm)
18
(480 mm)
7
/8"
5
A
6 ft (1.8 m)
2 ft
(0.6 m)
90° elbow
Wall cap
Cabinet Dimensions
1
/4" (184 mm)
7
65/8" (168 mm)
3
7
/8" (187 mm)
Side
cabinet
bottom of
canopy
to cooking
30"
“X”
surface
2" (51 mm) min.
6" (152 mm) min.*
(762 mm)30" (762 mm)
Centerline
Vent and power
supply cable
entry location
15" (381 mm)
Side
cabinet
Cooking surface
* For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61 cm) from electric cooking
surface, 27" (68.6 cm) from gas cooking surface
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights.
See the following chart.
Vented Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 7" (2.31 m)9' 5" (2.87 m)
surface
Gas cooking
7' 11" (2.41 m)9' 5" (2.87 m)
surface
Non-Vented (Recirculating) Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 8" (2.34 m)9' 8" (2.95 m)
surface
Gas cooking
7' 11" (2.41 m)9' 8" (2.95 m)
surface
NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights, depending on the distance
“X” between the bottom of the range hood and the cooking
surface.
Venting Requirements
■ Vent system must terminate to the outdoors except
for non-vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other
enclosed area.
■ Do not use 4" (10.2 cm) laundry-type wall cap.
■ Use metal vent only. Rigid metal vent is recommended.
■ The length of vent system and number of elbows should
6
Plastic or metal foil vent is not recommended.
be kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ Use clamps to seal all joints in the vent system.
■ The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with the
range hood.
■ Use caulking to seal exterior wall or roof opening
around the cap.
■ The size of the vent should be uniform.
Cold Weather Installations
An additional backdraft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting Methods
This canopy hood is factory set for venting through the roof
or wall.
A 6" (15.2 cm) round vent system is needed for installation
(not included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly
reduce performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, fitting a charcoal filter and the deflector. Fumes and
vapors are recycled through the top grille. To order, see the
“Assistance or Service” section.
Roof Venting
B
A. Roof cap
B. 6" (15.2 cm)
round vent
Wall Venting
B
A. Wall cap
B. 6" (15.2 cm)
round vent
Non-Vented
(Recirculating)
B
A
A. Deflector
B. 6" (15.2 cm)
round vent
A