IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANTE: LEA Y GUARDE ESTAS INSTRUCCIONES.
SÓLO PARA USO RESIDENCIAL.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI303E/W10502584G
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-866-664-2449.
In Canada, for assistance, installation and service, call: 1-866-664-2449.
CAMPANA PARA COCINA DE 30" (76,2 CM)
Instrucciones de instalación y Manual de uso y cuidado
Si tiene preguntas respecto a las características, funcionamiento, rendimiento, partes, accesorios o servicio técnico, llame al: 1-866-664-2449.
HOTTE DE CUISINIÈRE DE 30" (76,2 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composez le 1-866-664-2449
Table of Contents/Índice/Table des matières..................................................................2
For warranty concerns, do not take the appliance back to the store. Please contact us in U.S.A. or Canada at 1-866-664-2449.
This product features a Limited Warranty - See the “Warranty” section for complete details. IKEA
(excludes LAGAN family - see warranty for coverage details).
NOTE: Proof of Purchase is required to obtain warranty service.
Si tiene dudas acerca de la garantía, no devuelva el aparato a la tienda. Póngase en contacto con nosotros en los EE.UU. o en Canadá
al 1-866-664-2449.
Este producto tiene una garantía limitada - Consulte la sección “Garantía” para obtener todos los detalles. Los aparatos IKEA® tienen
una garantía de 5 años (excluyendo los de la familia LAGAN - consulte la garantía para ver los detalles acerca de la cobertura).
NOTA: Se requiere la prueba de compra para obtener servicio bajo la garantía.
Pour toute question concernant l’application de la garantie, ne pas rapporter l’appareil au magasin. Veuillez nous contacter aux É.-U.
ou au Canada au 1-866-664-2449.
Ce produit est couvert par une garantie limitée – Voir la section “Garantie” pour des détails complets. Les appareils IKEA
par une garantie de 5 ans (hormis les appareils de la série LAGAN - voir la garantie pour des détails concernant les modalités de
garantie).
REMARQUE : Une preuve d’achat est obligatoire pour obtenir l'application de la garantie.
®
appliances carry a 5-year warranty
®
sont couverts
TABLE OF CONTENTS
RANGE HOOD SAFETY .................................................................3
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
■ Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
■ Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
■ Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
■ Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
■ Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
■ When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
■ Ducted fans must always be vented outdoors.CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
■ Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
■ Always turn hood ON when cooking at high heat or when
■ Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
■ Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a
■ SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
■ NEVER PICK UP A FLAMING PAN - you may be burned.
■ DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
■ Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
– The fire department is being called.
– You can fight the fire with your back to an exit.
a
Based on "Kitchen Fire Safety Tips" published by NFPA.
■ WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control
device.
4
INSTALLATION REQUIREMENTS
†®TORX is a registered trademark of Saturn Fasteners, Inc.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Level
■ Drill
■ ¹⁄₈" (3 mm) drill bit
■ Pencil
■ Pliers
■ Tape measure or ruler
■ Caulking gun and weatherproof caulking compound
■ Phillips screwdriver
■ Flat-blade screwdriver
■ Saber or keyhole saw
■ Vent clamps
■ Metal snips
Parts needed
■ 6" (15.2 cm) round metal vent system
For vented installations, you will need:
■ 1 wall or roof cap
For non-vented (recirculating) installations, you will also
need:
■ Charcoal Filter Kit W10272068. See the “Assistance or
Service” section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
■ Hood liner assembly
■ Vent transition
■ Cabinet filler strip
■ 2 - mounting brackets
■ 1 - 30" x 12" (76.2 x 30.5 cm) face panel
■ 2 - metal grease filters
■ 1 - vent cover
■ Hardware package. Includes:
Installation Instructions and Use and Care Guide
6 - spacers
14 - 4.5 x 13 mm wood screws (#2 Phillips drive)
®†
2 - 4.2 x 15 mm sheet metal screws (T10 TORX
4 - 3.5 x 9.5 mm flat-head sheet metal screws (T10 TORX
drive)
8 - 4.2 x 19 mm sheet metal screws (#2 Phillips drive)
2 - 3.5 x 9.5 mm sheet metal screws (T10 TORX
®
T10 TORX
adapter
8 - metal washers
8 - plastic washers
drive)
®
drive)
®
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the liner behind the filter on the left wall of
the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance. Consult your cooktop/
range manufacturer installation instructions before making any
cutouts.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 Btus or less.
The range hood is factory set for vented installations through the
roof or wall. For non-vented (recirculating) installations see “NonVented (recirculating) Installation Through the Soffit/Cabinet” in
the “Prepare Location” section. Charcoal Filter Kit Part Number
W10272068 is available from your dealer or an authorized parts
distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
5
Product Dimensions
A
I
H
G
F
E
D
C
B
F
A
B
C
D
E
Cabinet Dimensions
A.
³⁄₈
" (1.0 cm)
B. 30" (76.2 cm)
C. 26" (66.0 cm)
D. 2" (5.1 cm)
E. 10
³⁄₄
" (27.4 cm)
F.
³⁄₄
" (1.9 cm)
G. 11
⁷⁄₈
" (30.2 cm)
H. 9
¹⁄₈
" (23.2 cm)
I. 13
⁵⁄₈
" (34.6 cm)
Venting Requirements
(vented models only)
■ Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other enclosed
area.
■ Do not use a 4" (10.2 cm) laundry-type wall cap.
■ Use metal vent only. A rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■ The length of the vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
■ Use no more than three 90° elbows.
A. 12" (30.5 cm) min. upper
cabinet height
B. 30" (76.2 cm) cabinet opening
width
C. 24" (61 cm) min. from electric
cooking surface, 27"
(68.6 cm) min. from gas
cooking surface 36" (91.4 cm)
suggested max. bottom of
cabinet to cooking surface
D. 12" (30.5 cm) cabinet depth
E. 15" (38.1 cm) min. clearance
upper cabinet to countertop
F. 36" (91.4 cm) base cabinet
height
6
■ Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ The vent system must have a damper.
■ Use clamps to seal all joints in the vent system.
■ Use caulking to seal exterior wall or roof opening around the
cap.
■ The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air systems
when using ventilation systems with greater than specified CFM
of air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
A
B
A
B
90˚ elbow
3 ft
(0.93 m)
6 ft (1.8 m)
Wall cap
A
A
B
B
C
D
D
E
E
F
F
G
G
I
H
This range hood is factory set for venting through the roof or
through the wall.
The vent system needed for installation is not included.
A 6" (15.2 cm) round vent system is recommended.
Roof VentingWall Venting
A. 6" (15.2 cm) vent through
the roof
B. Roof cap
A. 6" (15.2 cm) vent through
the wall
B. Wall cap
Calculate Vent System Length
Example vent system - 6" (15.2 cm)
Maximum Length= 35 ft (10.7 m)
1 - 90° elbow= 5 ft (1.5 m)
1 - wall cap= 0 ft (0 m)
9 ft (2.8 m) straight= 9 ft (2.8 m)
System length= 14 ft (4.3 m)
Non-Vented (recirculating) Installations Through the
Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to the
outside, the range hood can be used in the non-vented
(recirculating) version, using a charcoal filter. Charcoal Filter Kit
Part Number W10272068 is available from the dealer or an
authorized parts distributor.
Through CabinetThrough Soffit
The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 35 ft (10.7 m). For the best performance, use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
Vent Piece6" (15.2 cm)
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
F. C a b in e t
G. Wall
H. 12" (30.5 cm) min. cabinet
height
I. 17" (43.2 cm) min. vent cover
height
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow the
6" (15.2 cm) vent and vent cover to be seen.
7
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
33⁷⁄₁₆" (85 cm)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For a grounded, cord-connected range hood:
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING:Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latest edition) or Canadian Electrical Code, CSA C22.1
No. 0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
■ A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.
■ This range hood is equipped with a power supply cord having
a 3-prong grounding plug.
■ To minimize possible shock hazard, the cord must be
plugged into a mating, 3-prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
■ The grounded 3-prong outlet is to be located inside the
cabinet above the range hood at a maximum distance of
33⁷⁄₁₆" (85.0 cm) from where the power cord exits the hood.
See illustration.
■
The grounded 3 prong outlet must be accessible after the
hood installation. Do not install it in a closed cabinet with no
access.
8
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
B
C
B
A
A
A
A
A
D
B
C
Prepare Location
■ It is recommended that the vent system be installed before
the range hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
■ Making the cutout to the bottom of the cabinet may be easier
to do prior to mounting the cabinet to the wall.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Cabinet Cutout
IKEA AKURUM Type Cabinets
1. Install the top IKEA AKURUM suspension rail to the wall using
the instructions that come with it.
2. Install a second IKEA AKURUM suspension rail section 29³⁄₄"
(75.6 cm) long to the wall parallel to the top mounting rail and
12" (30.5 cm) lower. (See the following illustration.)
NOTE: This lower rail is to be used as a spacer. It does not
get attached to the cabinet.
4. Install the cabinet filler strip (supplied with range hood). Align
the cabinet filler strip flush with the bottom and front face of
the cabinet. Mark and drill ¹⁄₈" (3 mm) pilot holes in 2 places
on each end. Secure the cabinet filler strip to the inside of the
cabinet using four 4.5 x 13 mm #2 Phillips wood screws.
A. Screws - 4.5 x 13 mm (#2 Phillips)
B. Cabinet filler strip (supplied)
5. Assemble the cabinet doors to the cabinet using the
instructions that come with the door hinges.
NOTE: Align the cabinet doors, if necessary, using the
instructions that come with the door hinges.
6. Remove the cabinet doors from the door hinge clips that are
mounted to the inside of the cabinet according to the
instructions that come with the door hinges.
7. Locate side mounting bracket flush to the bottom of the
cabinet side and against the inside of the front of the cabinet
filler strip. Orient the bracket as shown in the following
illustration. Drill ¹⁄₈" (3 mm) pilot holes in 8 places, attach a
bracket using four 4.5 x 13 mm #2 Phillips screws to each
side of the cabinet, and tighten.
Bracket Orientation for 30" (76.2 cm) Cabinet
A. Wall
B. IKEA AKURUM cabinet suspension rails
C. 12" (30.5 cm)
3. Assemble the IKEA AKURUM cabinet using assembly
instructions that come with the cabinet with the exception:
“Do not assemble the bottom panel or the doors.”
A. 30" (76.2 cm) cabinet
B. Screws - 4.5 x 13 mm #2 Phillips (8)
C. Metal washers (optional)
D. Mounting bracket (2) (position for 30" [76.2 cm] cabinet)
9
Frame Type Cabinets
A
B
C
D
E
A
B
C
D
D
A
B*
C
A
B
D
C
1. Use a saber saw or keyhole saw to cut out the cabinet
bottom inside the cabinet frame.
A. Bottom of cabinet cutout
B. Bottom must be cut flush to the inside walls of the cabinet.
C. 10
⁷⁄₈
" (27.6 cm) min. from the inside of the cabinet front face
D.
³⁄₄
" (1.9 cm) thick front face required for cabinet bottom.
E. Front of cabinet
2. Locate side mounting bracket flush to the bottom of the
cabinet side and against the inside of the front cabinet face.
Orient the bracket as shown in the following illustration. Drill
¹⁄₈" (3 mm) pilot holes in 8 places, attach a bracket using four
4.5 x 13 mm #2 Phillips screws to each side of the cabinet,
and tighten. Additional plastic washers in hardware package
are supplied as spacers for cabinet walls thinner than ½"
(13 mm).
Bracket Orientation for 30" (76.2 cm) Cabinet
Cabinet Venting Preparation
1. Complete cabinet preparation following the instructions for
your type of venting. Determine venting cutout locations and
cut out vent openings in the cabinets, walls and/or soffit.
Venting Outside Through the Roof
Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent.
Go to Step 2.
A. Cutout
B. 6¼" (15.9 cm)*
C. 7
³⁄₄
" (19.7 cm) centerline to cabinet front
D. Centerline
*NOTE: For 12" (30.5 cm) high cabinets a 6¼" deep x 8" wide
(15.9 cm x 20.3 cm) rectangular opening in the cabinet top is
required for damper transition clearance.
Venting Outside Through the Wall
Install the 6" (15.2 cm) vent transition to the top of the range
hood liner using two 3.5 x 9.5 mm T10 screws. Assemble the
vent duct that you will use over the 6" (15.2 cm) vent
transition. Measure from the bottom of the range hood liner to
the horizontal centerline of the vent opening (A).
A. 30" (76.2 cm) cabinet
B. Screws - 4.5 x 13 mm #2 Phillips (8)
C. Metal washers (optional)
D. Mounting bracket (2) (position for 30" [76.2 cm] cabinet)
A. Measurement A
B. Horizontal centerline of vent opening
C. 3.5 x 9.5 mm T10 screws
D. Range hood liner
Remove the vent duct from the range hood liner.
10
Transfer measurement A to the cabinet back wall. Measure
B
A
C
E
A
C
D
B
A
B
A
B
from the underside of the cabinet. Mark the cutout as shown.
Use a saber saw or keyhole saw to cut a round opening
through the back of the cabinet and the exterior wall for the
vent.
Go to Step 2.
A. Measurement A
B. Centerline
C. 6¼" (15.9 cm) round cutout
Measure and mark the centerline of the cabinet to the soffit
above.
Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5¾"
(14.6 cm) hole for the vent cover. Attach the vent cover using
two 4.5 x 13 mm #2 Phillips screws.
A. Vent cover
B. Centerline
Non-Vented (recirculating) Installation Through the
Soffit/Cabinet
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
A. Cutout
B. Vent cover (installation without soffit)
C. See the following chart.
D. 7
³⁄₄
" (19.7 cm) centerline to cabinet front
E. Centerline
Cabinet HeightHole Shape and Size
For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.
For non-vented (recirculating) installations, charcoal filters are
necessary. See the “Range Hood Care” section for
instructions on installing charcoal filters.
The Charcoal Filter Kit Part Number W10272068 must be
used.
Complete Preparation
2. If it is not yet attached, install the 6" (15.2 cm) vent transition
to the top of the range hood liner using two 3.5 x 9.5 mm T10
screws.
A. Vent transition
B. 3.5 x 9.5 mm T10 screws
12" (30.5 cm)A 6¼" deep x 8" wide (15.9 cm x 20.3 cm)
rectangular opening in the cabinet top is
required for damper transition clearance.
15" (38.1 cm)
cabinet or soffit
installation
18" (45.7 cm) or
24" (61.0 cm)
A 6¼" (15.9 cm) diameter round opening is
required.
A 5¾" (14.6 cm) diameter round opening is
required.
3. Install the vent system according to the method needed. Use
caulking to seal the exterior wall or roof opening.
11
Install Range Hood
A
B
C
D
A
B
C
D
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
1. Using 2 or more people, lift the hood liner into its mounted
location. Attach with four 4.2 x 19 mm #2 Phillips screws into
the slotted openings. Do not tighten screws.
Connect the Vent System
Vented Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
Non-Vented (recirculating) Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
2. Install vent cover.
3. Install charcoal filters. See the “Range Hood Care” section.
To order replacement kits, see the “Assistance or Service”
section.
Complete Installation
1. Replace grease filters. See the “Range Hood Care” section.
A. Cabinet
B. Hood liner canopy assembly
C. Screws - 4.2 x 19 mm #2 Phillips (8)
D. Spacer - optional
2. If needed, insert up to three (3) spacers between each side of
the canopy and the mounting plate to space and center the
canopy in the cabinet. Align the bottom of the canopy with
the bottom of the cabinet. Install four 4.2 x 19 mm #2 Phillips
screws into the round mounting plate openings and tighten all
(8) mounting screws.
3. Remove the metal grease filters from the face panel. See the
“Range Hood Care” section.
4. Attach the 30" x 12" (76.2 cm x 30.5 cm) face panel (supplied
with range hood) to the hood liner using four 3.5 x 9.5 mm
T10 flat-head screws and two 4.2 x 15 mm T10 truss head
screws. Tighten to secure.
2. Plug 3-prong power cord into a grounded 3-prong outlet
located inside the cabinet above the range hood.
3. Check the operation of the range hood fan and light. See
“Range Hood Use” section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range
hood, read the “Range Hood Use” section.
4. Install the cabinet doors to the cabinet. Use the assembly
instructions that come with the cabinet.
5. Connect the lamp electrical connectors.
12
A. Screws - 3.5 x 9.5 mm T10 flat-head (4)
B. Face plate
C. Cabinet
D. Screws - 4.2 x 15 mm T10 truss-head (2)
RANGE HOOD USE
A
B
C
D
A
B
C
D
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the center of the front of the
range hood liner.
A. Blower and light controls
B. Grease filter
C. Grease filter handle
D. Halogen lamp housings
Range Hood Controls
A. On/Off light button
B. Blower off and speed minimum button
C. Blower speed medium button
D. Blower speed maximum button
Operating the Light
The On/Off light button controls all lights. Press once for On and
again for Off.
Operating the Blower
The Blower Speed buttons turn the blower on and control the
blower speed and sound level for quiet operation. The speed can
be changed anytime during fan operation by pressing the desired
blower speed button.
Press the Blower Off button a second time to turn off the blower.
13
RANGE HOOD CARE
A
A
B
C
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or
soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
■ Liquid detergent soap and water, or all-purpose cleanser
■ Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter
The filters should be washed frequently. Place metal filters in
dishwasher or hot detergent solution to clean.
Let filter dry thoroughly before replacing it.
Turn off fan and lights. Allow halogen lamp to cool.
1. Remove each filter by pulling the spring release handle and
then pulling down the filter.
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Kit Number
W10272068.
To replace charcoal filter:
1. Cover the grille that covers the blower motor with the
charcoal filter so that the slots on the filter correspond to the
pins on the sides of the motor grille.
A. Charcoal filter
B. Pins
C. Blower motor
2. Turn the charcoal filter clockwise to lock it.
3. Repeat steps 1-2 on the other filter.
A. Spring release handle
2. Wash metal filters as needed in dishwasher or hot detergent
solution.
3. Reinstall the filter by making sure the spring release handles
are toward the front. Insert metal grease filter into upper
track.
4. Pull the spring release handle down.
5. Push up on metal filter and release handle to latch into place.
6. Repeat steps 1-5 for the other filter.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Push up on the lens and turn it counterclockwise.
14
3. Remove the bulb and replace it with a 120-volt, 50-watt
maximum halogen bulb with a GU10 base. Turn it clockwise
to lock it into place.
4. Repeat steps 2-3 for the other bulb if needed.
5. Reconnect power.
WIRING DIAGRAM
Motor Characteristics
Power Supply
Frequency
Power Absorption
120 V
60 Hz
240 W
Motor Resistance
(Ohms)
BU/W
BU/R
BU/GY
BU/BK
Room Temp.
45.1
37.7
30.3
28.8
73.4˚F (23˚C)
Y
Y
Y
Y
Y
Y
BK
BK
BKBKGY
R
W
W
BU
BU
W
W
Y/G
Y/G
Y/G
BR
BR
Mechanical Push Buttons
(4 buttons 3 speeds)
W
W
W
BR- BK
(L - 4)
High Speed
BR - BU
(L - 3)
Med Speed
BR - W
(L - 2)
Low Speed
BR - Y
(L - 1)
Lamps
No Connection
Off
POSITION
FUNCTION
SWITCH OPERATION
Motor
Chassis
SE13BC
12.5uF
Ground
Common
Min. V
Med. V
High V
Max. V
S40
M
15