CONVERSIONS POUR CHANGEMENT DE GAZ ......................29
Conversion pour l’alimentation au propane ..............................29
Conversion pour l’alimentation au gaz naturel ..........................33
IMPORTANT:
Save for local electrical inspector’s use.
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
À conserver pour consultation par l’inspecteur local des installations électriques.
Installateur : Remettre les instructions d’installation au propriétaire.
Propriétaire : Conserver les instructions d’installation pour référence ultérieure.
W10722849C
RANGE SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
•
instructions.
If you cannot reach your gas supplier, call the fire department.
•
– Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
IMPORTANT: Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of
ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or
unintended operation.
2
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
■ If using a ball valve, it shall be a T-handle type.
■ A flexible gas connector, when used, must not exceed 3 feet.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.
To verify the anti-tip bracket is installed and engaged:
Anti-Tip
Bracket
Range Foot
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
• Slide range back so rear range foot is under anti-tip bracket.
• See installation instructions for details.
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Tape measure
■ Phillips screwdriver
■ TORX
■ Flat-blade screwdriver
■
■ Level
■ Hand or electric drill
■ Wrench or pliers
■ Pipe wrench
■
®†
T20®† screwdriver
1
/8" flat-blade screwdriver
15
/16" combination wrench
Parts supplied
Check that all parts are included.
■ LP/Natural Gas Conversion Kit (located on back of range
near lower side)
■ Burner grates
■ Burner caps
■ Oven racks
■ 2 - #12 x 1
■ Anti-tip bracket (taped inside upper oven with package
5
/8" screws (for mounting anti-tip bracket)
containing literature)
Anti-tip bracket must be securely mounted to back wall or
floor. Thickness of floor may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the “Electrical Requirements”
and “Gas Supply Requirements” sections.
1
■
/8" (3.2 mm) drill bit
■ Marker or pencil
■ Pipe-joint compound
resistant to LP gas
■ Noncorrosive leak-
detection solution
For LP/Natural Gas
Conversions
■ ½" combination wrench
9
■
/32" (7.0 mm) nut driver
■ Masking tape
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Do not obstruct flow of combustion and ventilation air.
■ It is the installer’s responsibility to comply with installation
clearances specified on the rating number plate. The rating
number plate is located behind the control panel.
■ The range should be located for convenient use in the
kitchen.
■ Recessed installations must provide complete enclosure
of the sides and rear of the range.
■ To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
■ All openings in the wall or floor where range is to be installed
must be sealed.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■ The floor anti-tip bracket must be installed. To install the
antitip bracket shipped with the range, see the “Install
Anti-Tip Bracket” section.
■ Grounded electrical supply is required. See the “Electrical
Requirements” section.
■ Proper gas supply connection must be available. See
the “Gas Supply Requirements” section.
■ Contact a qualified floor covering installer to check that
the floor covering can withstand at least 200°F (93°C).
■ Use an insulated pad or ¼" (0.64 cm) plywood under range
if installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate, or sustain other damage. This
oven has been designed in accordance with the requirements
of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A, or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
■ When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
4
Product Dimensions
B*
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible
construction at the rear and on the sides below the cooktop.
C**
A
D
F
A. 353/4" ± 1/8" (90.8 cm ± 0.3 cm)
cooktop height (minimum) with
leveling legs screwed all the
way in
B. Model/serial/rating plate
(located behind the control
panel)*
1
C. 47
/8" ± 1/8" (119.7 cm
± 0.3 cm) overall height
(minimum) with leveling legs
screwed all the way in**
1
/2" ± 1/4" (72.4 cm ± 0.6 cm)
D. 28
depth with handle
E. 261/8" to 271/4"
69.2 cm ± 0.3 cm)***
F. 2915/16" ± 1/16" (76.0 cm
± 0.2 cm) width
E***
± 1/8" (66.4 to
* Model/serial/rating plate may be rotated up from behind
the control panel for viewing from the front of the range.
** Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
*** Excludes handle. Dimension given is from wall to front of
oven door and will vary based on electrical outlet receptacle
installation.
B
D
C
A
E
F
J
I
K
L
G
H
8½"
(21.6 cm)
14"
(35.6 cm)
***
1½"
(3.8 cm)
1¼"*
(3.2 cm)
8½" (21.6 cm)**
gas line location
2¼" (5.7 cm)
A. 18" (45.7 cm) upper cabinet
to countertop
B. 15" (38.1 cm) max. upper
cabinet depth
C. 30" (76.2 cm) min. opening
width
D. For minimum clearance to the
top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening
width
F. 3" (7.6 cm) min. clearance from
both sides of the range to the
side wall or other combustible
material
G. Cabinet door or hinges should
not extend into the cutout.
H. 3" (7.6 cm) distance from wall
1
I. 1
/2" (3.8 cm) min. from right
side cabinet
J. 8" (20.3 cm) width
K. 7" (17.8 cm) height
L. 2" (5.1 cm) min. from floor
* Drill on centerline 1¼" (3.2 cm) from rear wall for gas
supply line.
** Gas lines must be installed within the shaded area to ensure
proper alignment of this oven with cabinets.
*** Electrical plugs must be installed within the shaded area
to ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than 1/4" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum, or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
5
Electrical Requirements
Gas Supply Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: The range must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
■ A 120-volt, 60 Hz., AC-only, 15-amp fused, electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range be provided.
■ Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
■ The wiring diagram is located on the back of the range
in a clear plastic bag.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 – latest edition or CAN/CGA B149 – latest
edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturers instructions.
Type of Gas
Natural gas:
■ This range is factory set for use with Natural gas. See the
“Gas Conversions” section. The model/serial/rating plate
located behind the control panel has information on the
types of gas that can be used. If the types of gas listed do
not include the type of gas available, check with the local
gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial/rating plate for use with a different
gas without consulting the serving gas supplier. See the “Gas
Conversions” section.
†®TEFLON is a registered trademark of Chemours.
6
Gas Supply Line
■ Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may result
in insufficient gas supply. With LP gas, piping or tubing size
can be ½" (1.3 cm) minimum. Usually, LP gas suppliers
determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON®† tape.