Ikea IBD550PRS02, IBD550PRS04, IBD550PRS05, IBD550PWS00, IBD650PXS00 Installation Guide

...
INSTALLATIONINSTRUCTIONS
30" (76.2 CM) ELECTRICSINGLEAND DOUBLE
BUILT-INOVEN
INSTRUCTIONSD'INSTALLATION
FOURELECTRIQUEENCASTRE30" (76,2 CM) -
SIMPLEETDOUBLE
TableofContents ITabledes mah_res
BUILT-IN OVEN SAFETY .............................................................. 2
INSTALLATION REQUIREMENTS ............................................... 3
Location Requirements .............................................................. 3
Electrical Requirements .............................................................. 5
INSTALLATION INSTRUCTIONS ................................................. 6
Prepare Built-In Oven ................................................................. 6
Make Electrical Connection ........................................................ 6
Install Oven ................................................................................. 7
Complete Installation .................................................................. 8
SI_CURITI_ DU FOUR ENCASTRI_ ............................................... 9
EXIGENCES D'INSTALLATION ................................................. 10
Outillage et pieces .................................................................... 10
Exigences d'emplacement ....................................................... 10
Specifications electriques ........................................................ 12
INSTRUCTIONS D'INSTALLATION ........................................... 13
Preparation du four encastre .................................................... 13
Raccordement electrique ......................................................... 13
Installation du four .................................................................... 15
Achever I'installation................................................................. 16
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT :
,&,conserver pour consultation par I'inspecteur local des installations 61ectriques.
8303102B
BUILT-INOVEN SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Phillips screwdriver
Measuring tape
Drill (for wall cabinet installations)
1" (25 ram) drill bit (for wall cabinet installations)
Level
Parts needed
UL listed or CSA approved conduit connector
UL listed wire connectors
Parts supplied
Two #8-14 x 1" screws
Bottom vent (supplied on some models)
Two #8-18 x 3/8"screws - bottom vent (supplied on some models)
Side trims (supplied on some models)
Two #8-18 x 3/8"screws - side trim (supplied on some models)
Check local codes. Check existing electrical supply. See "Electrical Requirements."
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Product Dimensions - Single Oven
A. 28%" (72.1 cm) max. recessed width B. 29" (73. 7 cm) max. overall height C. 29s/4'' (75.6 cm) overall width D. 23" (58.4 cm) max. recessed depth E. 271/_''(69.9 cm) recessed height
Cabinet Dimensions - Single Oven
Single Oven Undercounter (without cooktop installed above)
A
B
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete enclosure around the recessed portion of the oven.
Grounded electrical supply is required. See "Electrical Requirements" section.
Electrical supply junction box should be located 3" (7.6 cm) maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the right rear or left rear
corner of the support surface to pass the appliance cable through to the junction box.
NOTE: For undercounter installation, it is recommended that the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall behind oven, the junction box must be recessed and located
in the upper or lower right or left corner of the cabinet; otherwise, the oven will not fit into the cabinet opening.
Oven support surface must be solid, level and flush with bottom of cabinet cutout. Floor must be able to support a
single oven weight of 140 Ibs (63.5 kg) or a double oven weight of 245 Ibs (111.1 kg).
Undercounter Installation (with cooktop installed above):
Ovens approved for this type of installation have an approval label located on the top of the oven. Refer to undercounter
installation instructions for cutout dimensions and approved oven cooktop combinations (separate sheet).
i
" D
A. 30" (76.2 cm) min. cabinet width
B. 11/_'' (3.8 cm) min. top of cutout to
underside of countertop
C. 51/4'' (13.3 cm) bottom of cutout to floor
D. 281/_'' (72.4 cm) cutout width
E. 27s/4'' (70.5 cm) min. cutout height
+
C
Single Oven Installed in Cabinet
_A_
F _D_
Cabinet Dimensions - Double Oven
Double Oven Installedin Cabinet
B
B
Y
F
E
A. 30" (76.2 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door C. 32" (81.3 cm) bottom of cutout to floor D. 281/2''(72.4 cm) cutout width E. 11/2'' (3.8 cm) min. bottom of cutout to top of cabinet door
F. 273/4 '' (70.5 cm) min. cutout height
Product Dimensions - Double Oven
t
C
E
A. 30" (76.2 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door C. 143/4''(37.5 cm) bottom of cutout to floor D. 281/2" (72.4 cm) cutout width E. 11/2"(3.8 cm) min. bottom of cutout to top of cabinet door
F. 493/4'' (126.4 cm) min. cutout height
Cabinet Side View - Double or Single Oven
__/
E-.
D
C
/C
A. 28%" (72.1 cm) max. recessed width
B. 51" (129.5 cm) max. overall height C. 293/4''(75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 491/2''(125.7 cm) recessed height
A. 231/4'' (59.1 cm) min. cutout depth B. 23" (58.4 cm) recessed oven depth
C. Oven front D. Recessed oven
E.Cabinet
Cabinet filler kits are available from your dealer. Use matching color kit if oven is smaller than your cabinet opening.
Single oven filler height is 35A6'' (8.4 cm) Black - 4378941
White - 4378942
Almond - 4378943
Double oven filler height is 6sA6'' (16 cm) Black - 4378947
White - 4378948
Almond - 4378949
Ifcodespermitandaseparategroundwireisused,itis recommendedthataqualifiedelectricalinstallerdeterminethat thegroundpathandthewiregaugeareinaccordancewithlocal
codes. Checkwithaqualifiedelectricalinstallerifyouarenotsurethe
ovenisproperlygrounded. Thisovenmustbeconnectedtoagroundedmetal,permanent
wiringsystem. Besurethattheelectricalconnectionandwiresizeareadequate
andinconformancewiththeNationalElectricalCode,ANSI/ NFPA70-latesteditionorCSAStandardsC22.1-94,Canadian ElectricalCode,Part1andC22.2No.O-M91-1atestedition,and alllocalcodesandordinances.
Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation
OneBatterymarchPark
Quincy,MA02269
CSAInternational
8501EastPleasantValleyRoad
Cleveland,OH44131-5575
Electrical Connection
To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located at the bottom of the right-hand mounting rail. See the following
illustration.
Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW at 208 volts) require a separate 40-amp circuit. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit.
A circuit breaker is recommended. Connect directly to the circuit breaker box (or fused
disconnect) through flexible, armored or nonmetallic sheathed, copper cable (with grounding wire). See "Make
Electrical Connection" section.
Flexible conduit from the oven should be connected directly to the junction box.
Do not cut the conduit. The length of conduit provided is for serviceability of the oven.
A UL listed or CSA approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the ends of the
flexible conduit leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Single Oven
A. Model/serial number plate
Double Oven
A. Model/serial number plate
Loading...