Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You
instructions.
follow
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10210919A
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Ovens approved for this type of installation have an approval
label located on the top of the oven. Refer to undercounter
installation instructions for cutout dimensions and approved oven
cooktop combinations (separate sheet).
Too ls n ee de d
■ Phillips screwdriver
■ Measuring tape
■ Drill (for wall cabinet installations)
■ 1" (25 mm) drill bit (for wall cabinet installations)
■ Level
Parts needed
■ UL listed or CSA approved conduit connector
■ UL listed wire connectors
Parts supplied
■ 2 - #8–14 x 1" screws
■ Bottom vent (supplied on some models)
■ 2 - #8–18 x ³⁄₈" screws - bottom vent (supplied on some
models)
Check local codes. Check existing electrical supply. See
“Electrical Requirements.”
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
■ Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
■ Grounded electrical supply is required. See “Electrical
Requirements” section.
■ Electrical supply junction box should be located 3" (7.6 cm)
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should be located in the right rear or left rear corner of
the support surface to pass the appliance cable through to
the junction box.
NOTE: For undercounter installation, it is recommended that
the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, the junction box must be recessed and located
in the upper or lower right or left corner of the cabinet;
otherwise, the oven will not fit into the cabinet opening.
■ Oven support surface must be solid, level and flush with
bottom of cabinet cutout. Floor must be able to support a
single oven weight of 140 lbs (63.5 kg).
A. 30" (76.2 cm) min. cabinet width
B. 1¹⁄₂" (3.8 cm) min. top of cutout to
underside of countertop
C. 5¹⁄₄" (13.3 cm) bottom of cutout to floor
D. 28½" (72.4 cm) cutout width
E. 27¾" (70.5 cm) min. cutout height
B
C
2
Oven Installed in Cabinet
F
E
A. 30" (76.2 cm) min. cabinet
width
B. 1" (2.5 cm) top of cutout to
bottom of upper cabinet door
C. 32" (81.3 cm) bottom of
cutout to floor
Cabinet Side View
A
B
D
C
D. 28½" (72.4 cm) cutout width
E. 1¹⁄₂" (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 27¾" (70.5 cm) min. cutout
height
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and
all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■ Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located at the
bottom of the right-hand mounting rail. See the following
illustration.
A
A
B
E
A. 23¹⁄₄" (59.1 cm) min. cutout depth
B. 23" (58.4 cm) recessed oven depth
C.Oven front
D. Recessed oven
E. Cabinet
D
C
Cabinet filler kits are available from your dealer. Use matching
color kit if oven is smaller than your cabinet opening.
Filler height is 3⁵⁄₁₆" (8.4 cm).
Black - 4378941
White - 4378942
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
A. Model/serial number plate
■ Models rated at 5.1 kW and below at 240 volts (3.8 kW and
below at 208 volts) require a separate 30-amp circuit.
■ A circuit breaker is recommended.
■ Connect directly to the circuit breaker box or (fused
disconnect) through flexible, armored or nonmetallic
sheathed, copper cable (with grounding wire). See “Make
Electrical Connection” section.
■ Flexible conduit from oven should be connected directly to
the junction box.
■ Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
■ A UL listed or CSA approved conduit connector must be
provided.
■ If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the ends of the
flexible conduit leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
3
INSTALLATION INSTRUCTIONS
A
Prepare Built-In Oven
1. Decide on the final location for the oven. Avoid drilling into or
severing wiring during installation.
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
2. To avoid floor damage, set the oven onto cardboard prior to
installation. Do not use handle or any portion of the front
frame for lifting.
3. Remove the shipping materials and tape from the oven.
4. Remove the hardware package from inside the bag
containing literature.
5. Remove and set aside racks and other parts from inside the
oven.
6. Move oven and cardboard close to the oven’s final location.
Remove Oven Door
IMPORTANT: Use both hands to remove oven door(s).
1. Open the oven door.
2. Locate the oven door latches in both corners of the oven
door, and rotate the latches forward to the unlocked position.
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply
wire and a cabinet-connected green (or bare) ground wire twisted
together.
1. Disconnect power.
2. Feed the flexible conduit from the oven through the opening
in the cabinet.
3. Remove junction box cover, if it is present.
4. Install a UL listed or CSA approved conduit connector to the
junction box.
B
A. Oven door latch in locked
position
3. Grasp the edges of the oven door with both hands and close
the oven door until it will no longer close. Lift and pull oven
door toward you and remove. Set the oven door(s) aside on a
covered work surface.
B. Oven door latch in unlocked
position
A
A. UL listed or CSA approved conduit connector
5. Route the flexible conduit from the oven to the junction box
through a UL listed or CSA approved conduit connector.
6. Tighten screws on conduit connector.
7. See “Electrical Connection Options Chart” to complete
installation for your type of electrical connection.
4