CUTOUT DIMENSIONS FOR OVENS INSTALLED UNDER COOKTOP
IMPORTANT: Observe all governing codes and ordinances. Cooktop must be approved for use over an oven. See Cooktop Installation
Instructions for cutout dimensions. Center the cooktop cutout over oven cutout.
To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor,
delaminate or sustain other damage. This oven has been designed in accordance with UL and CSA International and complies with the
maximum allowable wood cabinet temperatures of 194°F (90°C).
Approved Built-In Oven and Electric Cooktop Combinations
A
C
D
G
A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth
C. Recommended oven and cooktop junction box locations
D. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
E. 27¾" (70.5 cm) minimum cutout height
F. 36" (91.4 cm) from cabinet base to countertop
G. 4⁵⁄₈" (11.7 cm) from floor
H. See Cutout Dimensions chart.
B
C
F
E
H
CUTOUT DIMENSIONS
Oven Size Oven Cutout Dimension
30" (76.2 cm) 28½" (72.4 cm)
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the
bottom of the cooktop burner box.
NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface
to pass the appliance cable through to the junction box.
W10373102A
Approved Built-In Oven and Induction Cooktop Combinations
A
C
D
G
A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth
C. Recommended oven and cooktop junction box locations
D. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
E. 27¾" (70.5 cm) minimum cutout height
F. 36" (91.4 cm) from cabinet base to countertop
G. 3⁵⁄₈" (9.2 cm) from floor
H. See Cutout Dimensions chart.
B
C
F
E
H
CUTOUT DIMENSIONS
Oven Size Oven Cutout Dimension
30" (76.2 cm) 28½" (72.4 cm)
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the
bottom of the cooktop burner box.
NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface
to pass the appliance cable through to the junction box.
2
Approved Built-In Oven and Gas Cooktop Combinations
A
D
EE
F
G
L
I
K
A. 24" (61 cm) minimum cabinet depth
B. 1" (2.5 cm) clearance from the top of junction box to the bottom of
the countertop
C. 25" (63.5 cm) countertop depth
D. Recommended grounded 120 volt outlet location for cooktop
E. Recommended oven junction box locations
F. 27¾" (70.5 cm) minimum cutout height
G. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
H. 34½" (87.6 cm) minimum cabinet height from floor to bottom of
countertop
I. Shaded area is recommended location for flexible or rigid gas pipe
installation.
J. 3¼" (8.3 cm)
K. 3½" (8.9 cm)
L. 4⁵⁄₈" (11.7 cm) from floor
M. See Cutout Dimensions chart.
NOTE: 24" (61.0 cm) minimum cutout depth required.
B
C
D
H
J
I
M
CUTOUT DIMENSIONS
Oven Size Oven Cutout Dimension
30" (76.2 cm) 28½" (72.4 cm)
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis.
NOTE: For undercounter installation, it is recommended that the junction box for the oven be located in the adjacent right or left
cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to
pass the appliance cable through to the junction box.
For undercounter installation, it is recommended that 120-volt grounded outlet for cooktop be located in the adjacent right or left
cabinet. A 2" (5.1 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to
pass the cooktop power cord to the grounded outlet.
For undercounter installation, it is recommended that flexible or rigid gas pipe installation be located in the adjacent right or left cabinet.
A 1" (2.5 cm) minimum diameter hole should have been drilled in the lower right or left corner of the side wall surface to pass the gas
supply line.
3