Igloo INN70.110, INN100.110, INN140.110, INN70.140, INN100.140 Instruction Manual

...
en
13
User manual INNOVAwww.igloo.pl
Contents List of Figures
1. UNLOADING 13
2. PROPERTIES OF THE DEVICE 13
2.1. Purpose 13
2.2. Description of the device 13
2.3. Technical data 15
3. PREPARING THE DEVICE FOR EXPLOITATION 16
3.1. Requirements concerning the place of installation 16
3.2. Connection and actuation 16
4. EXPLOITATION 16
4.1. Temperature regulation 17
4.2. Temperature regulation 17
5. MAINTENANCE 17
5.1. Cleaning and maintenance 17
6. SERVICE 19
6.1. Fault identication and repair 19
6.2. Service 20
7. THERMOSTAT SERVICE 20
7.1. „IGLOO” thermostat 20
7.2. „CAREL” thermostat 21
1. UNLOADING
2. PROPERTIES OF THE DEVICE
2.1. Purpose
The „INNOVA” display case is a universal cooling device for displaying and storage of short-term confectionery: tarts, ca­kes, biscuits, desserts, etc. at temperatures between +2°C / +15°C with ambient temperature +16°C / +25°C and relative air humidity of up to 60%.
2.2. Description of the device
„INNOVA” is equipped in dynamic cooling, automatic condensation evaporation and defrosting. The display case is also equipped with an electronic thermostat, which works optionally with the temperature registration module that enables registration and signalling high and low temperatures in the unit. Display cases are adapted to connect in sequences and can be powered by an internal unit within the temperature range of +2°C / +15°C. It is possible to control the humidity of the display case ranging from 40 to 90%. The exhibition part of the display case are glass shelves placed on a rack. The exposition shelves are able to change the position and angle of suspension. The glass elements are made of insu­lating glass lled with argon and black silk-screen printing. The „INNOVA” display cases use energy-saving LED back lighting. „IGLOO” Units are made in accordance with modern technology and possess the certicates required by law.
This sign signies information of particular meaning for user security and for proper device exploitation.
Instruction manual
INNOVA
en
Fig.1 Section of the device 14 Fig.2 Control panel 14 Fig.3 Construction of the unit 15 Fig.4 Humidistat 17 Fig.6 Cleaning the condenser 18 Fig.12 Data plate 19 Fig.13 „Igloo” thermostat control panel 20 Fig.14 „Carel” thermostat control panel 21
List of tables
Table 1 Technical data 2
en
14
User manual INNOVA www.igloo.pl
Rys.1 Section of the device
1 – The handle for opening the front glass 2 – Front glass 3 – Sliding or swing doors (model 70) 4 – Humidistat (humidity control system)
5 – Internal surfaces with glass shelf
6 – Suction (DO NOT BLOCK the vents!!!) 7 – Airow (DO NOT BLOCK the vents!!!)
8 – Plinth block 9 – Legs - used to level the unit 10 – Control panel (thermostat switches)
Rys.2 Control panel
1 – Main switch (switches on / off the unit) 2 – Light switch 3 – Electromagnetic lock the front glass extension 4 – Thermostat panel (temperature controller) (the details of operating in Chapter 7
en
15
User manual INNOVAwww.igloo.pl
Fig.3 Construction of the unit
1 – The handle for opening the front glass 2 – Front glass 3 – Glass shelf (upper) 4 – Interior lighting (upper) 5 – Wooden top (of granite) 6 – Glass display shelves (on the rack and internal surfaces) 7 – Hook (adaptable to angle of suspension) 8 – Internal frame 9 – Fan (When removed access to the lamella condenser- DO NOT BLOCK the vents!!!) 10– Wooden side wing 11 – Wooden side 12 – Electromagnetic lock the front glass extension 13 – Control panel 14 – Lamella condenser (keep clean!) 15 – Bumbon – Silicone element protecting glass components from moving and allowing for better grip (Do not dama-
ge during operation and maintenance!!!) 16 – Aluminium prole - glass shelf support (with backlight) 17 – Internal surfaces with glass shelf 18 – Composite side glass with screen printing 19 – Airow (DO NOT BLOCK the vents!!!)
2.3. Technical data
Table 1 Technical data
Type of the device
„INNOVA”
Rated voltage
[V/Hz]
Rated lighting
power [W]
Electric energy
consumption
[kWh/24h]
Max shelf load
[kg/mb]
Usable surface
[m2]
INN70.110 230/50 26,4 8,0 33 175
INN100.110 230/50 34,2 9,6 33 220
INN140.110
230/50
42,9
10,833235
INN70.140
230/50338,333280
INN100.140
230/50
40,2
9,933340
INN140.140
230/50
49,5
11,133145
en
16
User manual INNOVA www.igloo.pl
Place the plug of the connecting cable directly in plug-in socket (it is forbidden to connect the device by means of extension cords or dividers!)
Turn on the main switch Fig.2/2 (p.14), which activates the thermostat, and then aggregate of the device
Set the temperature on thermostat control panel Fig.2/1 (p.14) (thermostat service details on p.21 or 22)
Turn on the lighting switch Fig.2/3 (p.14)
4. EXPLOITATION
Temperature of the cooled space and aggregate operating cycle may uctuate. They depend on numerous factors, such as amount and temperature of products placed in the device and temperature of the surroundings. The device should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the wall and the device – min. 10 cm), out of sunlight, kept far from heat sources and devices enforcing air ow (ceiling and portable ventilators, blow-in heaters). The device functions properly in a room, where temperature falls within appropriate climatic class stated on the data plate. The operation of the device may worsen when it shall operate in temperature lower or higher than the stated temperature range.
Remarks and indications
• It is necessary to properly level the rack, which will prevent the device from noisy operation and will ensure proper outow of the water (condensate) during defrosting.
• After transporting the device, wait about 2 hours before its actuation.
• In order to ensure proper conditions for the stored products, do not load the shelves completely. It is neces-
3. PREPARING THE DEVICE FOR EXPLOITATION
3.1. Requirements concerning the place of installation
Verify whether the cross section of feeding conduits is proper for power consumption of the installed device.
It is forbidden to connect the device by extension rods or dividers.
The device should be connected to the separate, properly made electric circuit with plug-in socket with
protecting pin (according to PBUE /Regulations concerning Electric Equipment Construction/)
3.2. Connection and actuation
Unpack the device and remove the wooden platform from the basis Fig.3 (p.15)
The device should be placed on an even and on a sufciently hard base, and then level it with the help of
levelling feet.
• Remove the protection foil from the elements of the device (f. ex. from the inside of the device, display she­lves, front fender beam)
• If the user shall obtain a device partially disassembled to secure it during transportation, perform the following operations:
1. Fix hooks in frame rails Fig.3 (p.15)
2. Place shelves and/or baskets on hooks Fig.3 (p.15)
3. (Concerns the devices with internal aggregate) Place the condensate container on the basis of the aggregate, under water outow hose (does not concern devices with automatic condensate evaporation) Fig.5 (p.18)
4. (Concerns the devices to be mounted on central aggregate) Defrosting water outow is located under the bot­tom of the body (about 10mm from the back of the rack, in the middle part of the body), which needs toallow water outow to the sewage grit
The rst cleaning of the device should be provide right after unpacking, and before turning it on. The unit
should be cleaned with water at a temperature not exceeding 40°C with a neutral detergent. For washing and cleaning the equipment it is prohibited to use products containing chlorine and sodium varieties, which destroy the protective layer and components of the device! Any residue of adhesives or silicone on metal elements should be removed only with extraction naphtha (not applicable to items made of plastic !). Do not use other organic solvents.
When cleaning the unit is prohibited to use water jet. The unit should be cleaned with a wet rag.
After installation of the device at the destination place it should be left to rest for at least 2 hours before turning it on (for devices with built in compressor) to set the level of refrigerant in order to prevent problems with starting up the aggregate.
WARNING: Keep out the cooling circuit from damage!
Loading...