IDEMIA Identity and Security France MPHAC002A, MPHAC002B User Manual

Identity & Security
MorphoAccess® SIGMA Extreme Series
Installation Guide
COPYRIGHT © 2017 Safran Identity & Security
Osny, France
2017_2000024418 - Draft V0 January 2017
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Warning
2
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Warning
COPYRIGHT © 2017 Safran Identity & Security. All rights reserved.
Reproduction in whole or in part in any form or medium without the express written permission of Safran Identity & Security is prohibited.
The trademarks identified herein are the trademarks of registered trademarks of Safran Identity & Security, or other third party
This legend is applicable to all pages of this document.
Information in this document is subject to change without notice and do not represent a commitment on the part of Safran Identity & Security.
This manual makes reference to names and products that are trademarks of their respective owners.
MorphoAccess® SIGMA Extreme Series - Installation Guide Revision History
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
3
Version
Date
Reference
Description
01
January 2017
2017_2000024418 – Draft V0
Document creation - Draft
Revision History
The table below contains the history of changes made to the present document.
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Table of Content
4
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Table of Content
Warning ........................................................................................................................................ 2
Revision History ............................................................................................................................ 3
Section 1 : Introduction ................................................................................................................ 9
MorphoAccess® SIGMA Extreme Series Terminal ................................................................... 10
Scope of the document ............................................................................................................ 11
Safety Instructions ................................................................................................................... 12
Wiring Recommendations ................................................................................................... 13
Regulatory, safety and Environmental notices ....................................................................... 14
European Union (CE) regulatory notices ............................................................................. 14
USA (FCC) regulatory notices ............................................................................................... 15
Canada (IC) regulatory notices ............................................................................................ 16
Others recommendations .................................................................................................... 16
Recommendations for terminal implementation .................................................................... 17
Section 2 : General Description .................................................................................................. 20
Box opening ............................................................................................................................. 21
Components of the initial package ......................................................................................... 22
Terminal's front view description ............................................................................................ 23
Terminal's rear view description ............................................................................................. 24
MorphoAccess® SIGMA Extreme Series Technical Characteristics ......................................... 25
Section 3 : Installation Procedure ............................................................................................... 27
Before proceeding to the installation ..................................................................................... 28
Installation .............................................................................................................................. 29
Required tools (not supplied)............................................................................................... 29
Equipment from the initial package to use ......................................................................... 29
Step by step procedure ........................................................................................................ 30
Section 4 : Electrical Interface .................................................................................................... 34
Wiring overview ...................................................................................................................... 35
Power Supply ........................................................................................................................... 36
External Power supply ......................................................................................................... 36
POE (Power Over Ethernet) ................................................................................................. 36
Output Relay ........................................................................................................................... 37
Nominal characteristics of relay .......................................................................................... 37
MorphoAccess® SIGMA Extreme Series - Installation Guide Table of Content
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
5
Example of connection for electrical door locks .................................................................. 37
Tamper Switch ......................................................................................................................... 38
Operating principle for the switch ....................................................................................... 38
Nominal characteristics of switch block .............................................................................. 38
Wiegand wiring ....................................................................................................................... 39
Wiegand input ..................................................................................................................... 39
Wiegand output ................................................................................................................... 40
The controller supports neither LED1 nor LED2 signals ....................................................... 40
The controller supports only LED1 signal ............................................................................ 40
The controller supports LED1 and LED2 signals .................................................................. 41
Serial port wiring ..................................................................................................................... 42
DataClock Input ................................................................................................................... 42
DataClock Output ................................................................................................................ 42
RS485 ................................................................................................................................... 43
RS422 ................................................................................................................................... 43
GPIO wiring ............................................................................................................................. 44
Single Door Access Control (SDAC) implementation ........................................................... 44
Ethernet connection ................................................................................................................ 45
Default Ethernet configuration ........................................................................................... 45
Recommendations for RJ45 wiring ...................................................................................... 45
External USB connection ......................................................................................................... 46
Wi-Fi™ dongle installation ...................................................................................................... 47
Micro SD connection ............................................................................................................... 48
Section 5 : User Interface ........................................................................................................... 49
Modes for controlling access rights ........................................................................................ 50
Introduction ......................................................................................................................... 50
Identification mode ............................................................................................................. 50
Authentication (verification) mode ..................................................................................... 50
Multi-factor mode ............................................................................................................... 51
Proxy mode .......................................................................................................................... 51
External database mode (also called polling mode) ........................................................... 51
Configuring the terminal ......................................................................................................... 53
MorphoAccess® 500 or J Series legacy mode ...................................................................... 53
MorphoAccess® SIGMA Extreme Series native mode .......................................................... 54
Anti-tamper / anti-pulling switches ........................................................................................ 55
Section 6 : Accessories, Software Licenses and PC Applications ................................................ 56
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Table of Content
6
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Compatible Accessories, Licenses and Software ..................................................................... 57
Compatible PC applications .................................................................................................... 58
Section 7 : Recommendations .................................................................................................... 59
Global warning .................................................................................................................... 60
General precautions ............................................................................................................ 60
Areas containing combustibles ............................................................................................ 60
Specific precautions for terminals equipped with a contactless smartcard reader ............ 60
Ethernet connection ............................................................................................................ 60
Date / Time synchronization ............................................................................................... 60
Cleaning precautions ........................................................................................................... 61
Legacy mode ........................................................................................................................ 61
Micro SD card ...................................................................................................................... 63
Lighting conditions for face detection ................................................................................. 63
Main principles ........................................................................................................................ 65
Most useful areas for biometric data...................................................................................... 66
Position of finger ..................................................................................................................... 67
Finger height ........................................................................................................................ 67
Finger angle ......................................................................................................................... 67
Finger inclination ................................................................................................................. 68
Finger rotation ..................................................................................................................... 68
Troubleshooting ...................................................................................................................... 69
How to get the latest versions of documents ......................................................................... 71
Documents concerning the MorphoAccess® terminal ............................................................ 72
Documents about installing the terminal ............................................................................ 72
Documents about administrating / using the terminal ....................................................... 72
Documents for the developer .............................................................................................. 72
Release note ........................................................................................................................ 73
Troubleshooting ...................................................................................................................... 75
The terminal IP address is unknown or it is not possible to connect to the terminal.......... 75
The sensor is switched off .................................................................................................... 75
The terminal returns erratic responses to Ping commands ................................................ 75
Technical Support and Hotline ................................................................................................ 76
North America ..................................................................................................................... 76
South America ..................................................................................................................... 76
South Africa ......................................................................................................................... 76
India: .................................................................................................................................... 76
MorphoAccess® SIGMA Extreme Series - Installation Guide Table of Content
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
7
Europe and rest of the world: .............................................................................................. 76
Web site ............................................................................................................................... 76
Annex 1 : Finger Placement Recommendations ...................................................................... 64
Annex 2 : Bibliography ............................................................................................................. 70
Annex 3 : Support .................................................................................................................... 74
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Table of Figures
8
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Table of Figures
Figure 1: Implementation Recommendations ............................................................................. 18
Figure 2: Box Opening .................................................................................................................. 21
Figure 3: Box Content .................................................................................................................. 22
Figure 4: MorphoAccess® SIGMA Extreme Series terminal front view ....................................... 23
Figure 5: MorphoAccess® SIGMA Extreme Series terminal rear view ........................................ 24
Figure 6: Removing wall frame .................................................................................................... 28
Figure 7: Face camera viewing angle ........................................................................................... 30
Figure 8: Drilling template ........................................................................................................... 31
Figure 9: Wall plate fixing ............................................................................................................ 32
Figure 10: Cabling layout ............................................................................................................. 35
Figure 11: Power supply wiring ................................................................................................... 36
Figure 12: Output relay wiring ..................................................................................................... 37
Figure 13: Example of electric latch connection ......................................................................... 37
Figure 14: Tamper switch wiring ................................................................................................. 38
Figure 15: Wiegand input wiring ................................................................................................. 39
Figure 16: Wiegand output wiring ............................................................................................... 40
Figure 17: Serial port wiring – DataClock Input ........................................................................... 42
Figure 18: Serial port wiring – DataClock Output ........................................................................ 42
Figure 19: Serial port wiring – RS485 ........................................................................................... 43
Figure 20: Serial port wiring – RS422 ........................................................................................... 43
Figure 21: GPIO wiring ................................................................................................................. 44
Figure 22: SDAC wiring................................................................................................................. 44
Figure 23: RJ45 wiring .................................................................................................................. 45
Figure 24: External USB connection ............................................................................................ 46
Figure 25: Wi-Fi™ dongle installation .......................................................................................... 47
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
9
Section 1 : Introduction
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 1 :Introduction
10
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
MorphoAccess® SIGMA Extreme Series Terminal
Congratulations for choosing a MorphoAccess® SIGMA Extreme Series Automatic Fingerprint Recognition Terminal.
MorphoAccess® SIGMA Extreme Series provides an innovative and effective solution for access control applications using Fingerprint Verification or/and Identification.
Among a range of alternative biometric technologies, the use of finger imaging has significant advantages: each finger constitutes an unalterable physical signature, developed before birth and preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins.
MorphoAccess® SIGMA Extreme Series integrates Safran Identity & Security image processing and feature matching algorithms. This technology is based on lessons learned during 25 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records.
We believe you will find the MorphoAccess® SIGMA Extreme Series fast, accurate, easy to use and suitable for physical access control.
The MorphoAccess® SIGMA Extreme Series offers the following advantages:
high quality optical sensor (IQS quality sensor) with false finger detection option, supports multiple input/output interfaces used in the physical access control
industry,
Local Area Network interface for easy interaction with other host systems ; LAN
and WLAN possibilities (Wi-Fi™ as an option),
intuitive man machine interface with touch panel and display, that is easy to use in
both setup and operational modes,
sturdy wall mounting with easy holding of product during cabling or maintenance, ruggedezied design for harsh environment (IK09 and IP65).
To ensure the most effective use of your MorphoAccess® SIGMA Extreme Series terminal, we recommend that you read this Installation Guide completely.
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
11
MA SIGMA Extreme Series
Marketing Name
Biometrics
Fake
Finger
Detection
Contactless smartcard
reader
Water
Resistant
Regulatory
Model
Number (*)
iCLASS®
MIFARE® DESFire®
NFC
Prox®
MA SIGMA Extreme iClass
 MPH-AC002B
MA SIGMA Extreme Multi
MPH-AC002B
MA SIGMA Extreme Prox
MPH-AC002A
MA SIGMA Extreme FFD iClass
MPH-AC002B
MA SIGMA Extreme FFD Multi
  
MPH-AC002B
MA SIGMA Extreme FFD Prox
  
MPH-AC002A
Scope of the document
This guide deals with the installation of MorphoAccess® SIGMA Extreme Series, which is made up of following list of products:
(*) The Regulatory Model Number is the main product identifier in the regulatory documentation and test reports associated to the product
NOTA : MA means MorphoAccess
®
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 1 :Introduction
12
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Safety Instructions
means Direct Current (DC)
The installation of this product should be made by a qualified service Person and should comply with all local regulations.
It is strongly recommended to use a class II power supply at 12V-24V and 1A. min (at 12V) in conformity with Safety Electrical Low Voltage (SELV). The power supply cable length should not exceed 10 meters.
This system must be installed in accordance with the National Electrical Code (NFPA
70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying with IEC60950-1, in accordance with the NEC Class 2 requirements; or supplied by a listed IEC60950-1 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1A minimum or 24VDC, 0.5A minimum.
In case of building-to-building connection it is recommended to connect 0V to ground. Ground cable must be connected with the terminal block Power Ground.
Note that all connections of the MorphoAccess® SIGMA Extreme Series terminal described hereafter are of SELV (Safety Electrical Low Voltage) type.
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
13
V1
V2
L
Gauge
AWG
Diameter
(mm)
Maximum drop
voltage @ 1m
(V)
Maximum drop
voltage @ 5m
(V)
Maximum drop voltage @ 10m
(V)
20
0.81
0.03
0.17
0.33
22
0.64
0.05
0.26
0.53
24
0.51
0.08
0.42
0.84
Wiring Recommendations
Safran Identity & Security recommends using a gauge AWG20 for 12V power supply when
POE supply is not used.
The voltage specified is the one measured on the product block connector: 12V-24V (­15% / +10%)
For information, this table shows the maximum drop voltage observed on the terminal MorphoAccess® SIGMA Extreme Series:
Drop voltage = loss of power due to wire resistance and its length: V2 = V1 – Drop voltage
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 1 :Introduction
14
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Regulatory, safety and Environmental notices
European Union (CE) regulatory notices
Declaration of Conformity
Products bearing the CE marking comply with one or more of the following EU Directives as may be applicable:
Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC R&TTE Directive 1999/5/EC Ecodesign Directive 2009/125/EC RoHS Directive 2011/65/EU.
Compliance with these directives is assessed using applicable European Harmonised Standards.
MorphoAccess® SIGMA Extreme Series terminals are intended to be used for professional application only (buildings, airport...).
This is an EMC Class A product according to EMC directive 2004/108/EC. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce magnetic emissions to prevent interference to the reception of radio and television broadcast.
The full Declaration of Conformity is available on demand to your reseller. Please, provide him the product model name or its Regulatory Model Number (Model on the label).
Products with wireless features (EMF)
This product meets the provisions of the EU's Council recommendation 1999/519/EC on the limitation of the exposure of the general public to electromagnetic fields (0 Hz to 300 GHz).
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
USA (FCC) regulatory notices
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Responsible Party:
Safran Identity & Security
11, boulevard Gallieni
92130 Issy-les-Moulineaux – France
NOTA : This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Shielded cables must be used with this unit to ensure compliance with category B FCC restrictions.
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 1 :Introduction
16
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Canada (IC) regulatory notices
WARNING TO USERS IN THE CANADA / ATTENTION POUR LES UTILISATEURS AU CANADA
This device complies with Industry Canada license-exempt RSS standard(s), and with ICES 003 standard for version(s) without RFID reader. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Note : UL LLC has not verified this product for compliance in respect to Canadian standards.
Others recommendations
Potential safety conditions notice
If you notice any of the following conditions (or if you have other safety concerns), do not use the product: crackling, hissing, or popping sound, or a strong odor or smoke coming from the product. It is normal for these conditions to appear when an internal electronic component fails in a safe and controlled manner. However, these conditions may also indicate a potential safety issue. Do not assume it is a safe failure. Turn off the product, disconnect it from its power source, and contact technical support for assistance.
Disposal of waste equipment by users
This symbol means do not dispose of your product with your other household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment.
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
17
Recommendations for terminal implementation
Every installation is unique. Sometimes the issues are well defined and can be handled in a standard fashion; sometimes the issues are very specific and may not be immediately recognizable.
Safran Identity & Security recommends following these steps for a successful installation:
Plan the installation - Choose the type of hardware required, decide if a network is
required, and decide on the location and number of required terminals.
Unpack all items - Unpack all items and check against the packing list. Install network hardware components - Install the cabling and components
needed to run the system.
Install software - Install the software needed to set up the terminals. Pre-configure device - Connect the terminals to the Ethernet, supply power to the
terminals, and pre-configure the terminals.
Mount devices - Mount the terminals in their final locations Power distribution and device hook up - Connect the terminals wiring via the back
panel.
Power-up procedure - Check the power connections, and then start the system
safely. First Boot Assistant screen is displayed, where you can perform fundamental configuration.
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 1 :Introduction
18
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
ACCESS CONTROL
SYSTEM
(*) OR EQUIVALENT
NON SECURED
AREA
ACCESS
CONTROLLER
TCP/IP, Wiegand, Dataclock, RS485 or RS422
ELECTRIC
LATCH (*)
SECURED
AREA
Dry Contact
MorphoAccess® SIGMA Extreme
Terminal
Dry Contact
ALARM
To secure properly an access, Safran Identity & Security recommends installing the MorphoAccess® SIGMA Extreme Series terminal as a part of the typical Access Control environment, described in the figure below.
Figure 1: Implementation Recommendations
This environment comprises:
The MorphoAccess® SIGMA Extreme Series terminal itself
Its role is to perform one-to-many biometric identification or one-to-one biometric verification, i.e. to identify the individual who is presenting his finger on the terminal sensor by comparing his biometric data with the references previously stored in the terminal database (in the form of biometric templates) or to verify his identity using the reference stored in a contactless card presented to the terminal.
An Access Controller (3rd party product)
The Controller is the element which controls the access rights of the individuals to the secured area. For that reason, it must be located in the secured area.
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 1 : Introduction
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
19
The individuals who are authorized to access the secured area have their User ID listed in a so-called "Authorized User List" (in contrast with a banned card list).
The MorphoAccess® SIGMA Extreme Series terminal and the Controller are communicating according to one of the TCP/IP, Wiegand, Dataclock or RS485 protocols:
The MorphoAccess® SIGMA Extreme Series terminal sends User ID to the
Controller
The Controller sends its decision to the MorphoAccess® SIGMA Extreme Series
terminal (which displays access granted or access denied depending on the answer)
The MorphoAccess® SIGMA Extreme Series terminal sends an alarm signal to the
Controller as soon as a malicious operation is detected (terminal pulled out from the wall or opened for maintenance operations); refer the paragraph dealing with anti-pulling and anti-tamper switches for more explanations.
The Controller is part of the global Access Control System of the secured area, which can provide useful features such as manage:
authorized user lists (i.e. for VIP), banned card lists (i.e. for lost user cards), an access request log (who and when, access granted or denied,..), an event log (i.e. tamper detection, access control for evacuation of the
building,...).
The MorphoAccess® terminal is able to work alone, without Controller, but the protection level of the secured area is lower.
An Alarm (3rd party product)
This element is connected to the MorphoAccess® SIGMA Extreme Series terminal through a dry contact.
The MorphoAccess® SIGMA Extreme Series terminal sends the command to activate the Alarm as soon as a malicious operation (terminal pulled out from the wall or having its bottom cover opened out of maintenance operations) is detected; refer the paragraph dealing with anti-pulling and anti-tamper switches for more explanations.
A Door Electric Latch or equivalent (3rd party product)
This element once activated opens the access. The Controller is the one which sends the command to activate the latch if access is granted (i.e. if the individual's User ID is listed in the Controller Authorized User List). Connection between these two elements is done through a dry contact.
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 2 :General Description
20
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Section 2 : General
Description
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 2 : General Description
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
21
Box opening
At the box opening, components shall be extracted from the protection casing as depicted in the pictures below.
Extract the wall plate (which is not screwed to the terminal) and keep it separate until the installation of the terminal is completed. The screwing of the product to the wall plate is the last stage of the installation.
Figure 2: Box Opening
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 2 :General Description
22
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Components of the initial package
1. One (1) Terminal’s body
2. One (1) Wall frame
Figure 3: Box Content
MorphoAccess® SIGMA Extreme Series - Installation Guide Section 2 : General Description
Identity & Security
2017_2000024418 - Draft V0 January 2017
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
23
Microphone
Status LED
Camera
Light sensor
USB host
port
5" WVGA
touchscreen LCD
Optical biometric
sensor
Contactless
card area
Speaker
Terminal's front view description
Figure 4: MorphoAccess® SIGMA Extreme Series terminal front view
MorphoAccess® SIGMA Extreme Series - Installation Guide
Identity & Security
Section 2 :General Description
24
This document and the information therein are the property of Safran Identity & Security. They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - Draft
V0
January 2017
Micro SD
card slot
RJ45
USB port (for
configuration and
settings with a USB
mass storage key, or
for installation of a
Wi-Fi™ USB dongle)
Terminal signal
connector
RJ45
Wiegand
RS485/422
GPIO
Power supply
Relay
Tamper switch
Terminal's rear view description
Figure 5: MorphoAccess® SIGMA Extreme Series terminal rear view
Loading...