IDEC HW Series Catalog Page

Page 1
Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
ø22mm - HW Series
Mono Lever Switches 2-Position (Assembled)
Oiltight Switches & Pilot Devices
2-Position Mono Lever Switches
HW1M-F1010-20 Maintained up and down HW1M-F2020-20 Spring return up and down HW1M-F1010-40 Maintained up and down
HW1M Standard Lever
HW1M-L Interlocking Lever
1. All assembled part numbers in catalog include standard (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
4. Additional contact confi gurations available (up to 6 total contacts).
HW1M-F2020-40 Spring return up and down HW1M-F0101-20 Maintained right and left HW1M-F0202-20 Spring return right and left HW1M-F0101-40 Maintained right and left HW1M-F0202-40 Spring return right and left HW1M-LF1010-20 Maintained up and down HW1M-LF2020-20 Spring return up and down HW1M-LF1010-40 Maintained up and down HW1M-LF2020-40 Spring return up and down HW1M-LF0101-20 Maintained right and left HW1M-LF0202-20 Spring return right and left HW1M-LF0101-40 Maintained right and left HW1M-LF0202-40 Spring return right and left
Circuit Diagrams 2 Position Left/Right
Circuit Number
20
40
Contact Mounting Position
No. Left Center Right
1 HW-F10 X 0 0 2 HW-F10 0 0 X 1 HW-F10 X 0 0 2 HW-F10 0 0 X 3 HW-F10 X 0 0 4 HW-F10 0 0 X
2 Position Up/Down
Circuit Number
20
40
Contact Mounting Position No. Down Center Up
1 HW-F10 X 0 0 2 HW-F10 0 0 X 1 HW-F10 X 0 0 2 HW-F10 0 0 X 3 HW-F10 X 0 0 4 HW-F10 0 0 X
Circuit Breakers
534
www.idec.com
Page 2
Oiltight Switches & Pilot Devices
ø22mm - HW Series
Type
blank: Standard L: Interlocking
Mono Lever Switches 2-Position (Sub-assembled) Part Numbers
Contact Assembly +
Adaptor & Safety
Contact Blocks
Style Contacts 1NO 1NC
Standard Fingersafe (IP20)
Spring-Up Terminal
Exposed Screw Terminal
Dummy Block
HW-F10 HW-F01
HW-F10R (early make)
HW-G10 HW-G01
HW-G10R (early make)
HW-C10 HW-C01
HW-C10R (early make)
TW-DB
Contact Block Mounting Adaptor
Style Part Number
HW-CB2C
Part Number Structure
H W 1 M - L F 0 1 0 1 20
up right down left
Lever Action
1: Maintained 2: Spring 0: Blocked
Anti-Rotation
Lever Lock
+
Ring
+ Operator = Completed Unit
Anti-Rotation Ring
Appearance Part Number
HW9Z-RL
HW-F01R (late break)
HW-G01R (late break)
Use with notched panel cutout to prevent
unit rotation.
Operators
Appearance Description Part Number
HW-C01R (late break)
Standard Maintained Up/Down HW1M-1010
Spring return Up/Down HW1M-2020 Maintained Left/Right HW1M-0101
Spring return Left/Right HW1M-0202
Interlocking
Maintained Up/Down HW1M-L1010 Spring return Up/Down HW1M-L2020 Maintained Left/Right HW1M-L0101
Spring return Left/Right HW1M-L0202
Replacement Parts
Item Part Number
Black Cap
HW9Z-CPM
Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks
Circuit Number
20 or 40 (see contact arrange­ment on previous page)
1. Used to mount contact blocks to operator (fi rst pair only).
2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts.
Boot
HW9Z-BLM (fi ts standard operator only)
USA: 800-262-IDEC Canada: 888-317-IDEC
Circuit Breakers
535
Page 3
Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
ø22mm - HW Series
Mono Lever Switches 3- & 4-Position (Assembled)
Oiltight Switches & Pilot Devices
3-Position
Description Part Number Description
HW1M Standard Lever
HW1M-L Interlocking Lever
Circuit Diagram
Circuit Number
30
HW1M-F0121-30
HW1M-F0222-30 Spring return right, down, left
HW1M-LF0121-30
HW1M-LF0222-30 Spring return right, down, left
Contact Mounting Position No. Down Left Center Up Right
1 HW-F01 0 0 0 O X 2 HW-F01 X 0 0 O 0 3 HW-F10 0 X 0 0 0
Maintained right and left, spring return down
Maintained right and left, spring return down
4-Position
Description Part Number Description
HW1M-F1111-22N9 Maintained all positions
HW1M Standard Lever
HW1M-L Interlocking Lever
Circuit Diagram
Circuit Number
22N9
HW1M-F1212-22N9
HW1M-2121-22N9
HW1M-2222-22N9 Spring return all positions HW1M-LF1111-22N9 Maintained all positions
HW1M-LF1212-22N9
HW1M-LF2121-22N9
HW1M-LF2222-22N9 Spring return all positions
Contact Mounting Position No. Down Left Center Up Right
1 HW-F01 0 O 0 0 X 2 HW-F01 X 0 0 0 0 3 HW-F10 0 X 0 0 0 4 HW-F10 0 0 0 X 0
Maintained up and down, spring left and right
Spring up and down, main­tained left and right
Maintained up and down, spring left and right
Spring up and down, main­tained left and right
1. All assembled part numbers in catalog include standard (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
4. Additional contact confi gurations available (up to 6 total contacts).
Circuit Breakers
536
M1F11-R becomes HW1B-M111-R).
www.idec.com
Page 4
Oiltight Switches & Pilot Devices
ø22mm - HW Series
Type
blank: Standard L: Interlocking
Mono Lever Switches 3 & 4-Position (Sub-assembled) Part Numbers
Contact Assembly +
Adaptor & Safety
Contact Blocks
Style Contacts 1NO 1NC
Standard Fingersafe (IP20)
Spring-Up Terminal
Exposed Screw Terminal
Dummy Block
HW-F10 HW-F01
HW-F10R (early make)
HW-G10 HW-G01
HW-G10R (early make)
HW-C10 HW-C01
HW-C10R (early make)
TW-DB
Contact Block Mounting Adaptor
Style Part Number
Part Number Structure
H W 1 M - L F 0 1 2 1 30
up right down left
Lever Action
1: Maintained 2: Spring 0: Blocked
Anti-Rotation
Lever Lock
+
Ring
+ Operator = Completed Unit
Anti-Rotation Ring
Appearance Part Number
HW9Z-RL
HW-F01R (late break)
HW-G01R (late break)
HW-C01R (late break)
Use with notched panel cutout to prevent
unit rotation.
Operators
Appearance Description Part Number
Combination, 3 position HW1M-0121
Standard
Interlocking
Spring return, 3 position HW1M-0222 Maintained, 4 position HW1M-1111 Combination, 4 position HW1M-1212 Combination, 4 position HW1M-2121 Spring return, 4 position HW1M-2222 Combination, 3 position HW1M-L0121 Spring return, 3 position HW1M-L0222 Maintained, 4 position HW1M-L1111 Combination, 4 position HW1M-L1212 Combination, 4 position HW1M-L2121 Spring return, 4 position HW1M-L2222
Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks
Circuit Number
3 Position: 30 4 Position: 22N9
HW-CB2C
1. Used to mount contact blocks to operator (fi rst pair only).
2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts.
Replacement Parts
Item Part Number
Black Cap
HW9Z-CPM
Boot
HW9Z-BLM (fi ts standard operator only)
USA: 800-262-IDEC Canada: 888-317-IDEC
Circuit Breakers
537