Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
ø22mm - HW Series
Mono Lever Switches 2-Position (Assembled)
Oiltight Switches & Pilot Devices
2-Position Mono Lever Switches
DescriptionPart NumberDescription
HW1M-F1010-20Maintained up and down
HW1M-F2020-20Spring return up and down
HW1M-F1010-40Maintained up and down
HW1M
Standard Lever
HW1M-L
Interlocking Lever
1. All assembled part numbers in catalog include standard (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F”
from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
4. Additional contact confi gurations available (up to 6 total contacts).
HW1M-F2020-40Spring return up and down
HW1M-F0101-20Maintained right and left
HW1M-F0202-20Spring return right and left
HW1M-F0101-40Maintained right and left
HW1M-F0202-40Spring return right and left
HW1M-LF1010-20Maintained up and down
HW1M-LF2020-20Spring return up and down
HW1M-LF1010-40Maintained up and down
HW1M-LF2020-40Spring return up and down
HW1M-LF0101-20Maintained right and left
HW1M-LF0202-20Spring return right and left
HW1M-LF0101-40Maintained right and left
HW1M-LF0202-40Spring return right and left
Mono Lever Switches 2-Position (Sub-assembled) Part Numbers
Contact Assembly+
Adaptor & Safety
Contact Blocks
StyleContacts 1NO1NC
Standard
Fingersafe
(IP20)
Spring-Up
Terminal
Exposed
Screw
Terminal
Dummy
Block
HW-F10 HW-F01
HW-F10R
(early make)
HW-G10 HW-G01
HW-G10R
(early make)
HW-C10 HW-C01
HW-C10R
(early make)
TW-DB
Contact Block Mounting Adaptor
StylePart Number
HW-CB2C
Part Number Structure
H W 1 M - L F 0 1 0 1 20
up right down left
Lever Action
1: Maintained
2: Spring
0: Blocked
Anti-Rotation
Lever Lock
+
Ring
+Operator=Completed Unit
Anti-Rotation Ring
AppearancePart Number
HW9Z-RL
HW-F01R
(late break)
HW-G01R
(late break)
Use with notched panel cutout to prevent
unit rotation.
Operators
AppearanceDescriptionPart Number
HW-C01R
(late break)
StandardMaintained Up/DownHW1M-1010
Spring return Up/DownHW1M-2020
Maintained Left/RightHW1M-0101
Spring return Left/RightHW1M-0202
Interlocking
Maintained Up/DownHW1M-L1010
Spring return Up/DownHW1M-L2020
Maintained Left/RightHW1M-L0101
Spring return Left/RightHW1M-L0202
Replacement Parts
ItemPart Number
Black Cap
HW9Z-CPM
Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
Circuit Number
20 or 40 (see contact arrangement on previous page)
1. Used to mount contact blocks to operator (fi rst pair only).
2. IDEC strongly recommends using the safety
lever lock (included) to prevent heavy vibration
or maintenance personnel from inadvertently unlocking
contacts.
Boot
HW9Z-BLM (fi ts standard
operator only)
USA: 800-262-IDEC Canada: 888-317-IDEC
Circuit Breakers
535
Page 3
Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
ø22mm - HW Series
Mono Lever Switches 3- & 4-Position (Assembled)
Oiltight Switches & Pilot Devices
3-Position
DescriptionPart NumberDescription
HW1M
Standard Lever
HW1M-L
Interlocking Lever
Circuit Diagram
Circuit
Number
30
HW1M-F0121-30
HW1M-F0222-30Spring return right, down, left
HW1M-LF0121-30
HW1M-LF0222-30Spring return right, down, left
Contact MountingPosition
No.DownLeftCenterUpRight
1HW-F01000OX
2HW-F01X00O0
3HW-F100X000
Maintained right and left,
spring return down
Maintained right and left,
spring return down
4-Position
DescriptionPart NumberDescription
HW1M-F1111-22N9Maintained all positions
HW1M
Standard Lever
HW1M-L
Interlocking Lever
Circuit Diagram
Circuit
Number
22N9
HW1M-F1212-22N9
HW1M-2121-22N9
HW1M-2222-22N9Spring return all positions
HW1M-LF1111-22N9Maintained all positions
1. All assembled part numbers in catalog include standard (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
4. Additional contact confi gurations available (up to 6 total contacts).
Circuit Breakers
536
M1F11-R becomes HW1B-M111-R).
www.idec.com
Page 4
Oiltight Switches & Pilot Devices
ø22mm - HW Series
Type
blank: Standard
L: Interlocking
Mono Lever Switches 3 & 4-Position (Sub-assembled) Part Numbers
Contact Assembly+
Adaptor & Safety
Contact Blocks
StyleContacts 1NO1NC
Standard
Fingersafe
(IP20)
Spring-Up
Terminal
Exposed
Screw
Terminal
Dummy
Block
HW-F10HW-F01
HW-F10R
(early make)
HW-G10HW-G01
HW-G10R
(early make)
HW-C10HW-C01
HW-C10R
(early make)
TW-DB
Contact Block Mounting Adaptor
StylePart Number
Part Number Structure
H W 1 M - L F 0 1 2 1 30
up right down left
Lever Action
1: Maintained
2: Spring
0: Blocked
Anti-Rotation
Lever Lock
+
Ring
+Operator=Completed Unit
Anti-Rotation Ring
AppearancePart Number
HW9Z-RL
HW-F01R
(late break)
HW-G01R
(late break)
HW-C01R
(late break)
Use with notched panel cutout to prevent
unit rotation.
Operators
AppearanceDescriptionPart Number
Combination, 3 positionHW1M-0121
Standard
Interlocking
Spring return, 3 positionHW1M-0222
Maintained, 4 positionHW1M-1111
Combination, 4 positionHW1M-1212
Combination, 4 positionHW1M-2121
Spring return, 4 positionHW1M-2222
Combination, 3 positionHW1M-L0121
Spring return, 3 positionHW1M-L0222
Maintained, 4 positionHW1M-L1111
Combination, 4 positionHW1M-L1212
Combination, 4 positionHW1M-L2121
Spring return, 4 positionHW1M-L2222
Switches & Pilot LightsDisplay LightsRelays & SocketsTimersTerminal Blocks
Circuit Number
3 Position: 30
4 Position: 22N9
HW-CB2C
1. Used to mount contact blocks to operator (fi rst pair only).
2. IDEC strongly recommends using the safety
lever lock (included) to prevent heavy vibration
or maintenance personnel from inadvertently unlocking
contacts.
Replacement Parts
ItemPart Number
Black Cap
HW9Z-CPM
Boot
HW9Z-BLM (fi ts standard
operator only)
USA: 800-262-IDEC Canada: 888-317-IDEC
Circuit Breakers
537
Loading...