IDEC HS6B Series Catalog

Door Interlock Switches
HS6B Series Subminiature Interlock Switch
HS6B features:
Only 78 x 30 x 15mm
• Allows highest level of safety by having 3 contacts: dual load contacts + monitoring
• contact (ISO13849-1, EN954-1)
Two actuator entrances provide fl exibility for installation options
• Integral molded cable reduces wiring time
• IP67 (IEC60529) watertight sealing (contact is sealed, housing allows drainage)
• Direct Opening Action: Opening the door forces the contacts to disconnect even if the
• contacts are welded (IEC/EN60947-5-1)
Actuators comply with ISO14119 and EN1088
HS6B Series
Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work
GS-ET-15 BG standard in Germany
Contact Confi guration Cable Length
1NC-1NO
11
2NC
11
2NC-1NO
11 21
3NC
11
21
31
Zb
12 3433
Zb
12 3231
Zb
12 22 3231
Zb
12
22
32
1m HS6B-11B01
3m HS6B-11B03
5m HS6B-11B05 1m HS6B-02B01
3m HS6B-02B03
5m HS6B-02B05 1m HS6B-12B01
3m HS6B-12B03
5m HS6B-12B05
1m HS6B-03B01
3m HS6B-03B03
5m HS6B-03B05
Contact Confi guration & Operation Chart
HS6B-11
HS6B-02
HS6B-12
HS6B-03
1NC-1NO
2NC
2NC-1NO
3NC
11
11
11 21
11 21 31
Direct Opening Action
Part Number
(Standard Stock in bold)
Zb
12 3433
Zb
12 3231
Zb
12 22 3433
Zb
12 22 32
Actuator inserted completely Actuator removed completely
Double Insulation
Part Numbers
0.8 (Actuator Mounting Reference Position)
0
5.5
11-12 33-34
11-12 31-32
11-12 21-22 33-34
11-12 21-22 31-32
Part Number Key
HS6B - 12 B 01
Cable Length
01: 1 meter 03: 3 meters 05: 5 meters
Head Color
B (Black)
Contact Confi guration
11: 1NO-1NC 12: 1NO-2NC 02: 2NC 03: 3NC
Contact Operation ChartContact ConfigurationType
5.8 28.2 (Travel: mm)
: Contact ON (closed)
: Contact OFF (open)
USA: 800-262-IDEC Canada: 888-317-IDEC
345
HS6B Series
Actuator Keys
Appearance Part Number Shape Appearance Part Number Shape
Door Interlock Switches
HS9Z-A61
Straight (Mainly for sliding doors)
HS9Z-A65
OverviewX Series E-StopsDoor Interlock SwitchesEnabling SwitchesBarriersAS-Interface Safety at Work
HS9Z-A62
The actuators are not included, must be ordered separately.
Right-angle (Mainly for hinged doors)
HS9Z-A66
Specifi cations
Conforming to Standards EN1088, IEC60947-5-1, EN60947-5-1, GS-ET-15, IEC60664-1, IEC60204-1, EN60204-1, UL508 Operating Temperature –25 to +70˚C (no freezing) Storage Temperature –40 to +80˚C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Storage Humidity 95% RH maximum (no condensation) Altitude 2,000m maximum Pollution Degree 3 Rated Insulation Voltage (Ui) 300V Impulse Withstand Voltage (Uimp) 4kv
Insulation Resistance
Electric Shock Protection Class Class II Degree of Protection IP67 (IEC60529)
Vibration Resistance
Contact Resistance 300mΩ maximum
Shock Resistance
Direct Opening Travel 8 mm minimum Direct Opening Force 60N minimum Thermal Current (lth) 2.5A
Rated Operating Current (Ie)
Maximum Actuation Frequency 1200 operations/hour Mechanical Life 1,000,000 operations (at full rated load) Recommended Actuation Speed 0.05 to 1.0m/s Wire Tensile Strength 50N minimum Electrical Life 100,000 operations (at full rated load) Conditional Short-Circuit Current 50A 250V (IEC60947-5-1, IEC60269-1, -2) Weight 120g
Operating Extremes 5 to 55 Hz, half amplitude 0.5 mm Damage Limits 30Hz, half amplitude 1.5mm
Operating Extremes 300m/s2 (30G) Damage Limits 1000m/s
Between live & dead metal parts: 100MΩ maximum Between positive & negative live parts: 100MΩ minimum
2
(100G)
Operating Voltage (Ue) 30V 125V 250V
Resistive load (AC12) 2.5A 1.5A
AC
Inductive load (AC15) 1.5A 0.75A
Resistive load (DC12)
DC
Inductive load (DC13)
2.5A 1.1A 0.55A (2A) (0.4)A (0.2A)
2.3A 0.55A 0.27A (1A) (0.22A) (0.1A)
adjustable actuator 90° angle
adjustable actuator 180° angle
346
www.idec.com
Door Interlock Switches
gj
HS6B Series
Installation Notes
Recommended Screw Torque
Safety switch body installation (M4 screw): 1.0~1.5N-m
Actuator installation (M4 screw): 1.0~1.5N-m
Handling Cables
Do not tighten or loosen the fastened cable conduit of the safety switch
Minimum bend radius of installed cable: 40mm
Wiring Designations
Part Number Color Contact Part Number Color Contact
HS6B-12B01
(2NC-1NO)
HS6B-03B01
(3NC)
blue-blue/white NC
brown-brown/white NC orange-orange/white NO
orange-orange/white NO
blue-blue/white NC orange-orange/white NC
HS6B-11B01
(1NC-1NO)
HS6B-02B01
(2NC)
brown-brown/white NC
blue-blue/white NC
blue-blue/white NC
orange-orange/white NC
Dimensions (mm)
HS6B Installation
10.4
11
R2.2
(58)
Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work
20 to 22
20
30
10.1
Slot Plug (Note 1) (supplied)
Note 1: Plug the unused actuator entry slot using the slot plug supplied with the interlock switch.
5.5
5.5
10.4
35
27.6
78
4
(9)
4
(ø7.6)
15
Using straight actuator (HS9Z-A61) Using Right-angle actuator (HS9Z-A62)
(12.6±1)
30.8
0.8
(5)
)
±1
(30.1
Actuator Stop (Note 2) (supplied)
Straight actuator (HS9Z-A61) Right-angle actuator (HS9Z-A62) Actuator Installation
2-ø4.3
14
20.9
14
43.2
(15.8)
15 0.8
(14)50.8
0.8
Actuator Stop (Note 2) (
supplied)
When mounted (5.6)
8.4
When
mounted (5)
2-ø9
Rubber Bushing
10.4
1.2
3.5
Actuator Stop (supplied) (Note 2)
(5)
(14)
±1
0.8
40.1
When mounted (33.8)
2-ø9
(21.4)
22.6
0.8
When mounted (5)
Rubber Bushing
1.2
Actuator Stop (supplied) (Note 2)
±1
0.8 (41.4)
8.4
14
2-ø4.3
1413.1
3.5
34
2-M4 Screws
(ø4.3 or M4 tapped)
The interlock switch can be mounted in two directions.
Using Angle Adjustable Actuator (HS9Z­A65/A66)
28.8
0.8
(25)
±1
Actuator Stop (Note 2) (
Straight/Right-angle Actuator
Angle Adjustable Actuator
15.1
supplied)
2-M4 Screws
(ø4.3 or M4 tapped)
2-M4 Screws
(ø4.3 or M4 tapped)
(25)
22.6
±1
0.8
48.8
14
25
USA: 800-262-IDEC Canada: 888-317-IDEC
347
Loading...