Idec HG4F-JT22TFW, HG3F-FT22TFW, HG2F-SB52VF, HG2F-SS22VF, HG2F-SS52VF Data Sheet

...
Operator Interfaces
Operator Interface Touchscreen Family
Smart design to fi t your needs
4.6” STN LCD, our screens support either mono­chrome or 256 colors with high pixel resolution to give you sharp images and excellent visibility. In keeping with IDEC’s attention to detail, our slim­body design adapts to applications where space is limited. With up to 8MB of memory and a 200MHz 32-bit RISC CPU, IDEC Touchscreens put control, power and speed at your fi ngertips.
Versatile, High functionality
IDEC Touchscreens can function as either a stand alone controller or communicate with IDEC PLCs and a wide array of major manufacturers’ PLCs. Touchscreens interface with any of your equipment to provide graphical data presentations in vivid color and to display bar graphs and meters to represent analog data. Illuminated pushbuttons can replace physical mechanical switches; pilot lamps can dis­play on/off states and show almost any production information you need to monitor.
OI Touchscreen Family
PLCs Operator Interfaces Automation Software Power Supplies Sensors
12.1” HG4F
Programming power made easy
IDEC’s powerful WindO/I-NV2 software lets you cre­ate colorful graphical interfaces for easier produc­tion supervision and control. A built-in library of over 5000 bitmap images helps you easily display almost every manufacturing activity you want to control. Our programming software is intuitive and user­friendly. With re-sizeable pop-up screens, Windows compatible fonts, and multilingual text capabilities, you enjoy the utmost fl exibility in designing and programming.
5.7” HG2F
10.4” HG3F
4.6” HG1F
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
71
OI Touchscreen Family
Operator Interfaces
Features
The OI Touchscreen Family is ideally matched to today’s sophisticated technology. Using a wide range of graphical options, you can represent specifi c equipment, make production information immediately apparent and instantly display safety problems.
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
Consolidating controls on an IDEC touchscreen eliminates costly investments in wir­ing and installation of multiple pushbutton indicators on a traditional control panel. Just think how you can benefi t with touchscreens.
Expansion I/O
An expansion digital I/O module gives you the option of expanding your system with 16 DC inputs and 16 transistor outputs for basic PLC control (excluding 4.6” HG1F touchscreen).
Basic Data Representation
A built-in software library of over 5000 bit­mapped images lets you graphically represent al­most any plant activity or equipment that you want to monitor or control. In addition to representing meters, bar graphs and switches, you can also incorporate keypads to facilitate changing values. Our user-friendly programming software lets you design each screen by simply selecting objects from a pull-down menu or from a row of object icons and dropping it onto the screen work area. All bitmap images are available in 256 colors and are easily re-confi gurable.
Ethernet Support
Remote Network
Local Area
Network
Ethernet
The built-in 10BaseT Ethernet port found on the 10.4” and 12.1” touchscreens allow communications with PLCs using Ethernet/IP, Modbus TCP/IP or IDEC networking protocol. The touchscreens also allow you to remotely monitor machine-operating status via the Internet or your Local Area Network using any web browser. Regard­less of your location, you can use your PC’s browser (Netscape or Internet Explorer) to collect data about any touchscreen project. You can effi ciently monitor and manage production activity from your offi ce without the time or expense of travel.
Recipe, Alarm and Trend Logging
Compact Flash Card
The Recipe function allows you to conveniently set operational parameters, which can be individually defi ned for different processes. The Alarm func­tion stores historical events with a date and time stamp compliant to the ISA (Instrument Society of America) Standards, adding additional options to display and manage alarm messages. Trend Logging expresses data in graphical form according to the time period you defi ne. Using these functions, you can quickly view production information and collect and manage data.
Communication & Networking
72
OI Touchscreens (excluding 4.6” HG1F) support Compact Flash (CF) Cards with up to 512 MB of memory. In addition to storing recipe, alarm and trending data, the CF Card can also store screen captures in a BMP format for documentation purposes. The CF Card can hold one or more projects and you can easily transfer a project directly to another touchscreen by simply inserting the card into the second touchscreen and downloading what you need.
www.idec.com
Operator Interfaces
OI Touchscreen Family
Features, con’t
To meet your application needs, IDEC offers 12.1” and 10.4” TFT LCD screens, and 4.6” and 5.7” STN LCD screens that come with 256 colors or in monochrome to provide you with either multicolored or gray scale graphics. All screens have high pixel resolution and super bright LCD screens with 400 cd/m2 for the 12.1”, 450 cd/m2 for the 10.4” screen, 250 cd/m2 for the 5.7” and 500 cd/m2 for the 4.6” screen to provide sharp quality images, with RS-232 / RS-485 / RS-422 communica-
tion. In addition, all IDEC Touchscreens communicate with IDEC as well as many other industry leading PLC manufacturers.
Their slim body style of: 35.3mm depth for the 4.6” HG1F, 50mm depth for the 5.7” HG2F, 49.6mm depth for the 10.4” HG3F, and 52.1mm depth for the 12.1” HG4F, provide an advantage in space in a panel.
OI Link Communication
Support of Leading Manufacturer’s PLCs
IDEC Touchscreen communications capabilities expand well beyond IDEC brand PLCs. Other major PLC manufacturers supported are: Allen Bradley, Mitsubishi, Omron, Automation Direct (Koyo), Keyence, GE, Modicon, Siemens, Sharp, Hitachi, Schneider, Yaskawa, Fanuc, Matsushita Electric Works (Panasonic) and Yokogawa.
The 10.4” and 12.1” IDEC Touchscreens can remotely communicate with multiple devices or PLCs over an Ethernet network, using Ethernet/IP, Modbus TCP/IP, or IDEC 1:N drivers. Only one centrally located IDEC touchscreen is necessary to com­municate with up to 16 PLCs that are located in different locations. The Ethernet/IP driver supports the following Allen Bradley Series PLCs: Micrologix, SLC500, PLC5 and ControlLogix.
Approvals and International Ratings
The OI Touchscreen Family is UL listed for use in hazardous locations (Class I Div.
2). In addition the 4.6” and 5.7” screens are IP65 and Nema Type 13 rated, while the 10.4” and 12.1” screens are IP66, Nema Type 4, 4X, 13 rated so they can be used in the most demanding industrial applications.
Printer Function
PLCs Operator Interfaces Automation Software Power Supplies Sensors
This permits a single PLC to communicate with multiple IDEC touchscreens, where one touchscreen serves as the master and up to 15 as slaves. An OI Link will accommodate communications over a maximum distance of 200 meters. The OI Link should be used whenever you are using more than one touchscreen in a location to monitor and control a single PLC.
1:N PLC Communication
This mode allows a single IDEC touchscreen to communicate with multiple PLCs. It is used when you need only one centrally located touchscreen to monitor and control PLCs in different locations. Depending on the PLC type, a maximum of 31 PLCs can be connected to one touchscreen. PLC manufacturers supported for 1:N communication are: IDEC OpenNet Controller and MicroSmart family, Automa­tion Direct (Koyo): DirectLogic-DL205/405 and Modicon: Modbus RTU.
Pass Thru Function
This function lets you download a PLC program from a PC through the touch­screen without interrupting operations. Only one cable is needed to program both units. The Pass Thru communications function is applicable to the following PLCs: IDEC OpenNet Controller and MicroSmart family, and Mitsubishi MELSEC­FX, FX3UC and Q.
Use this capability to print alarm data so a hard-copy record of specifi c events can be maintained. Copies of screens can also be printed when needed for docu­mentation. Serial printers are supported on all OI Touchscreens, while Parallel Printers are supported on 10.4” and 12.1” models.
Barcode Reader Support
IDEC Touchscreens provide a serial port that you can confi gure for use by special communication devices such as barcode readers. A barcode reader can send data directly to the touchscreen, where it can be used for quick viewing before being transferred to the PLC for further data manipulation.
Debugging Functions
Two modes are available for either monitoring data or troubleshooting. Once you download the project you created in WindO/I-NV2 to the touchscreen, you can use the Debugging Mode to communicate directly with the touchscreen and switch between screens or view and modify batch data from the controls of your PC. In Simulation Mode, you can use simple On/Off control without connecting to the PLC.
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
73
OI Touchscreen Family
Easy Programming: Intuitive Drag & Drop Functionality
The WindO/I-NV2 software for all OI Touchscreens is the programming
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
tool that lets you create colorful graphical interfaces to visualize operating conditions. The software is very intuitive with drag and drop functionality. The Help menus are a great source of information and a built-in library of bitmaps provides over 5000 images to help expand your creativity. The software also includes a debug function where you can go online with the touchscreen for monitoring and changing data.
Flexible Screen Display for Effi cient Editing
With WindO/I-NV2 software, screens can be easily arranged. A total of 3000 base screens can be created (as allowed by the memory size). Sub-screens known as pop-up menus can be resized, made (showing backgrounds) using the superimpose function, and can be made to appear anywhere inside the base screen.
Easy to manage Projects and Screens
Screens and Project Settings List:
Operator Interfaces
WindO/I-NV2
Programming Software
Screens can be duplicated and their properties can be changed easily.
Project settings can be edited.
Devices, text, and images can be imported or exported.
Screen Preview List:
Screens can easily be selected using the preview image function.
Object List:
Each object displays its properties such as; type of device used, condi­tions and operations.
Buttons:
A button selected from an object list is shown on the editing screen.
Extensive Image Library
A built-in symbol library provides over 5000 symbols to help you create cutting-edge graphical screens. Image data from BMP, JPG, DXF, WMF, and ICO fi les can also be imported.
Communication & Networking
74
www.idec.com
Operator Interfaces
OI Touchscreen Family
WindO/I-NV2 Software, con’t
Compatible with Standard WindowsTM Fonts
Fonts used in WindowsTM can be used on the OI Touchscreens, making it possible to choose from a variety of text styles.
Easy Programming of Operating Conditions
Multilingual Capabilities for Worldwide Applications
The OI Touchscreen family can support other languages. With the text group function you can create a text database in different languages. Once the touchscreen is in a different country (e.g. China or Mexico) the customer can easily switch all text messages from English to Chinese or Spanish by a touch of a button.
Windows 2000, Vista and XP make it possible to input Japanese, Simpli­fi ed Chinese, Traditional Chinese, and Korean languages, Western European languages (English, German, French, Italian, Spanish, Dutch, Norwegian, Dan­ish, Finnish, Swedish, etc.) Central European languages (Czech, Hungarian, Romanian, Croatian, Slovene, Polish, and Slavic), Baltic languages, Cyrillic languages (Russian, Ukranian, Bulgarian, Macedonian).
PLCs Operator Interfaces Automation Software Power Supplies Sensors
Operating conditions for objects such as switches, lamps, bit/word write,
screen switching, and many more are easy to use. Step by step wizards guide the user through the set-up process.
Create Recipes to set parameters for different processes
Upload or download parameters to and from the PLC
1,024 available channels; store up to 8,000 parameters per channel
Set up Alarm Log function for messages and alerts
Monitors alarm conditions from a PLC and stores historical events with a date and time stamp
Meets ISA standards for visual alarm management
Select size and contrast of alarm message and status
Scroll a list of alarm messages
Create Trend Graphs to monitor critical data points
Quickly view production information
Script function
Users with programming knowledge in C can combine conditional statements,
• mathematical operations and other functions to create simple and complex processes.
Greatly reduce the programming required in the PLC.
A syntax check function is also available to provide easy program trouble-
• shooting.
Security function
Provides different levels of security and restrictions for multiple users on edit-
• ing projects or displaying screens and objects.
Communication & Networking
Collect and manage data
Up to 16 channels in a graph
USA: 800-262-IDEC Canada: 888-317-IDEC
75
OI Touchscreen Family
Operator Interfaces
Available Functions
Category Item HG1F
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
Communication
User Memory
Interface
Display Color
Brightness Resolution Touch Switch CC Switch Expansion Unit
Features
Functions
Available Functions
Parts
WindO/I-NV2 Functions
Communication & Networking
*2MB used for OS **four tactile push regions (40 x 70 pixels)
HG2F
Standard CC Switch Option
PLC link communication √√√√√ DM link communication √√√√√ OI link communication √√√√√ Ethernet √ No host √√√√√
RS232C/RS485 (422) √√√√√ Ethernet √ CF card slot √ Parallel √ 256 colors √ Monochrome
(cd/m2) 500 250 250 450 400
(pixels) 300 x 100 320 x 240 320 x 160** 640 x 480 800 x 600
Digital I/O unit
System program download √ Font download √ Download via Ethernet √ Download via OI link √ Project transfer via CF card √ Printer output √ Backlight replacement √ Environment resistance √ Simulation √ Pass through √ Device monitor √ Web server function √ Overlapped screens √ Sub-screen superimpose √ Text group switching √ Script √ Part operating condition setting √ Alarm log √ Logging √ Recipe √√√√√ Password setting √ Bit button √ Word button √√√√√ Goto screen button √ Print button √ Key button √ Keypad √ Selector switch √ Potentiometer √ Numerical input √ Character input √ Pilot lamp √ Picture display √ Message display √ Message switching display √ Alarm list display √ Alarm log display √ Numerical display √ Bar graph √ Trend chart √ Pie chart √ Meter √ Calendar √ Bit write command √ Word write command √ Goto screen command √ Timer √√√√√ Print command √ Screen print command √ Debugging √ Log data upload tool √ Graphic library tool √ Screen import √ Text browser √√√√√ Device browser √ Script browser √ Picture browser √ Basic/advanced mode √ Preview √√√√√ Windows font √ Library function √ Global replace √ Work space √√√√√
1 MB 2 MB 2 MB 8 MB* 8 MB*
16 x 12 16 x 8 32 x 24 40 x 30
4 x 1 row (bottom)
HG3F HG4F
76
www.idec.com
Operator Interfaces
OI Touchscreen
Part Numbers Bezel Color Description
HG4F-JT22TFW Light Gray Color TFT LCD Touchscreen
12.1”
10.4”
5.7”*
5.7” with CC Click
4.6”
*Black bezel models available upon request.
HG4F-JT22TFB Black* Color TFT LCD Touchscreen
HG4F-JT22TFW-DH485-500 Light Gray Color TFT LCD Touchscreen with DF1 / DH485 converter/cable package for SLC 500 (w/RJ45 connector)
HG3F-FT22TFW Light Gray Color TFT LCD Touchscreen
HG3F-FT22TFB Black* Color TFT LCD Touchscreen
HG3F-FT22TFW-DH485-500 Light Gray Color TFT LCD Touchscreen with DF1/DH485 converter/cable package for SLC 500 (w/RJ45 connector)
HG2F-SS22VCF Light Gray Color STN LCD Touchscreen
HG2F-SB22VCF Light Gray Monochrome STN LCD Touchscreen
HG2F-SS22VCF-DH485-500 Light Gray Color STN LCD Display with DF1 / DH485 converter/ cable package for SLC500 (w/RJ45 connector)
HG2F-SB22VCF-DH485-500 Light Gray Monochrome STN LCD Display with DF1 / DH485 converter / cable package for SLC500 (w/RJ45 connector)
HG2F-SS52VCF Light Gray Color STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology
HG2F-SB52VCF Light Gray Monochrome STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology
HG1F-SB22BF-W Light Gray Monochrome STN LCD Touchscreen, RS-232 comm.
HG1F-SB22BF-B Black Monochrome STN LCD Touchscreen, RS-232 comm.
HG1F-SB22YF-W Light Gray Monochrome STN LCD Touchscreen, RS-485/RS-422 comm.
HG1F-SB22YF-B Black Monochrome STN LCD Touchscreen, RS-485/RS-422 comm.
OI Touchscreen Family
Part Numbers
PLCs Operator Interfaces Automation Software Power Supplies Sensors
Accessories
Accessories
Accessory Description Part Number
Programming Tools
Converters
Protective Sheet
Mounting Clips
Replacement Backlight
OI Link Unit For all OI touchscreens HG9Z-2G1
32 Point Digital I/O
Compact Flash Card 128MB CF Card for 5.7” HG2F, 10.4” HG3F, 12.1” HG4F HG9Z-MF128
Replacement Battery Lithium Battery for 4.6” HG1F HG9Z-XR1
WindO/I-NV2 Programming software for all IDEC Touchscreen Series HG9Y-ZSS2W
Cable connecting PC to Touchscreen via RS-232 Serial Port HG9Z-XCM1A
USB to RS-232 Convertor for PCs without Serial Ports FC4A-USB
AB SLC500 (w/RJ45 connector) DF1 / DH485 Communication Package for HG2F/3F/4F HG9Z-GWDF1DH485-3
AB SLC500 (w/RJ45 connector) DF1 / DH485 Communication Package for 4.6” HG1F HG9Z-GWDF1DH485-4
For 12.1” HG4F (minimum order quantity is 2 pcs.) HG9Z-4DAP
For 10.4” HG3F (minimum order quantity is 2 pcs.) HG9Z-3DAP
For 5.7”HG2F (minimum order quantity is 5 pcs.) HG9Z-2D2
For 4.6” HG1F (minimum order quantity is 5 pcs.) HG9Z-1D
For 10.4” HG3F & 12.1” HG4F (minimum order quantity is 10 pcs.) HG9Z-4K1
For 5.7” HG2F (minimum order quantity is 4 pcs.) HG9Z-2K1
For 4.6” HG1F (minimum order quantity is 10 pcs.) SLD-K02
For 12.1” HG4F HG9Z-4FB
For 10.4” HG3F HG9Z-3FB2
For 5.7” HG2F HG9Z-2B1
For 4.6” HG1F HG9Z-1FB
For 10.4” HG3F & 12.1” HG4F (16 Inputs & 16 Outputs) HG9Z-3P102
For 5.7” HG2F (16 Inputs & 16 Outputs) HG9Z-2P101
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
77
Cables
OI Touchscreen Family
Operator Interfaces
Manufacturer Series Applicable CPU
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
FA-3S
FA-2J PF2J
Micro3 FC2A RS485 Built-in Port HG9Z-1C121A HG9Z-3C115A
Micro3C FC2A-%C
IDEC
OpenNet FC3A
MicroSmart/Pentra MicroSmart
PLC-5 1785
PLC-5E 1785 Ethernet Built-in Port Not Supported
SLC-5/03, SLC­5/04, SLC5/05
Allen Bradley
SLC5/05 1747-L55 Ethernet Buit-in Port Not Supported
MicroLogix 1000, 1100, 1200, 1500
MicroLogix 1100 1763 Ethernet Built-in Port Not Supported
ControlLogix 1756
CompactLogix 1768, 1769
FlexLogix 1794-L33, 1794-L34 RS232 Built-in Port Contact IDEC* Contact IDEC*
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
PF3S-CP12/CP13
PF3S-CP11/CP11T
FC4A, FC5A
1747-L53, 1747-L54, 1747-L55
1761, 1762, 1763, 1764
Communication & Networking
Communication
Type
RS232
RS485 PF3S-SIF4
RS232 PF2-CLA
RS232 Built-in Port HG9Z-XC183 HG9Z-3C125A
RS485 Built-in Port HG9Z-1C131A HG9Z-2C145A
RS232 Built-in Port HG9Z-XC183 HG9Z-3C125A
RS485 Built-in Port HG9Z-1C131A HG9Z-2C145A
Ethernet FC4A-SX5ES1E Not Supported
RS232
RS485
Ethernet FC4A-SX5ES1E Not Supported
RS232
RS422
Ethernet 1785-ENET Not Supported
RS232 Built-in Port HG9Z-XC100 HG9Z-2C125A
DH485 Built-in Port
Ethernet 1761-NET-ENI Not Supported
RS232 Built-in Port HG9Z-XC500 HG9Z-2C135A
Ethernet 1761-NET-ENI Not Supported
RS232 Built-in Port Contact IDEC* Contact IDEC*
Ethernet 1756-ENBT Not Supported
RS232 Built-in Port Contact IDEC* Contact IDEC*
Ethernet Buit-in Port Not Supported
Communication Module
Required
PF2-CLA
PF3S-SIF2
Built-in Port FC4A-KC1CA
FC4A-PC1/HPC1
FC4A-PC2/HPC2 HG9Z-1C121A HG9Z-3C115A
FC4A-PC3/HPC3 HG9Z-1C131A HG9Z-2C145A
Built-in Port
1770-KF2
Built-in Port
1770-KF2
HG1F Comm.
Cable P/N
Contact IDEC* Contact IDEC*
HG9Z-XC183 or FC4A-KC1CA
Contact IDEC* Contact IDEC*
please purchase IDEC converter: HG9Z­GWDF1DH485-4 (DF1-DH485 converter)
HG2F/3F/4F Comm.
Cable P/N
CAT 5 Ethernet Crossover cable
FC4A-KC2CA
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
please purchase IDEC converter: HG9Z-GWDF1DH485-3 (DF1-DH485 converter)
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
78
www.idec.com
Operator Interfaces
Cables
OI Touchscreen Family
Manufacturer Series Applicable CPU
Direct Logc 05 DL05 Ethernet D0-ECOM/DO-ECOM100 Not Supported
Direct Logc 06 DL06 Ethernet D0-ECOM/D0-ECOM100 Not Supported
D2-240 RS232 Built-in Port HG9Z-XC400 Contact IDEC*
Automation Direct (Koyo)
Siemens
Schneider (Telemecanique, SquareD)
Direct Logic 205
Direct Logic 405
S7-200
S7-300
S7-400 CPU 412, 414, 416, 416F-2, 417
Twido
D2-240, D2-250, D2-250-1, D2-260
D4-430, D4-440
D4-430, D4-440,D4-450 Ethernet
CPU 212, 214, 215, 216, 221, 222, 224, 224XP, 226, 226XM
CPU 313, 314, 315, 315-2DP, 316, 318
TWDLCA10DRF RS485 Built-in Port HG9Z-1C121A HG9Z-3C115A
TWDLCA*DRF ( *16,24,40 CPUs)
TWDLMDA*DTK/DUK/DRT (* 20 & 40 CPUs)
Momentum 171CCC96020 RJ-45 Ethernet Port Built-in RJ-45 Port Not Supported
Others Others
Panasonic (Aromat)
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
FP
Any PLCs that support MOD­BUS/TCP protocol
FP0 RS232 Built-in-Port HG9Z-XC300 HG9Z-2C165A
FP1
Communication
Type
Ethernet
RS232
RS422 Built-in Port
RS485 Built-in Port Contact IDEC* HG9Z-2C155A
RS232
RS232
RS485 Built-in Port HG9Z-1C121A HG9Z-3C115A
RS232 TWD NAC 232D HG9Z-XC183 HG9Z-3C125A
RS485 TWDNAC485D HG9Z-1C121A HG9Z-3C115A
RS485 TWDNAC485T HG9Z-1C131A HG9Z-2C145A
Communication Module
Required
D2-ECOM
D2-ECOM-F
D2-ECOM100
Built-in Port
D4-ECOM
D4-ECOM-F
D4-ECOM100
CP-340-RS232C or CP-341-RS232C
CP-340-RS 422/485 or CP-341-RS 422/485
CP-440-RS 422/485 or CP-441-RS 422/485
CP-440-RS232C or CP-441-RS232C
HG1F Comm.
Cable P/N
Not Supported
Contact IDEC* Contact IDEC*D4-DCM
Not Supported
Contact IDEC* Contact IDEC*RS485
HG2F/3F/4F Comm.
Cable P/N
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
RS485 Built-in Port HG9Z-1C121A HG9Z-3C115A RS232 TWDNOZ232D HG9Z-XC183 HG9Z-3C125A RS485 TWDNOZ485D HG9Z-1C121A HG9Z-3C115A
RS485
RS485
RS232
RJ-45 Ethernet Port Built-in RJ-45 Port Not Supported
RS232
RS422 Built-in-Port
TWDNOZ485T or TWDX­CPODM+ TWDNAC485T
TWDXCPODM + TWD­NAC485D
TWDXCPODM + TWD­NAC232D
Built-in-Port
HG9Z-1C131A HG9Z-2C145A
HG9Z-XC183 HG9Z-3C125A
HG9Z-1C121A HG9Z-3C115A
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Crossover cable
Contact IDEC* Contact IDEC*AFP8550
PLCs Operator Interfaces Automation Software Power Supplies Sensors
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
79
Cables
OI Touchscreen Family
Operator Interfaces
Manufacturer Series Applicable CPU
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
Panasonic (Aromat) con’t
Mitsubishi
Communication & Networking
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
FP
MELSEC-A
MELSEC-Q
MELSEC-QnA
FP Sigma
FP10, FP10SH
FP2, FP2SH
A1N, A2N, A3N
A1SH
A2CCPUC24 RS232 Built-in-Port HG9Z-XC203
A0J2, A0J2H
A2A, A3A, A2U, A3U, A4U
A2US, A2USH-S1
A2N
A1SJH, A1SH, A2SH, A2C, A0J2H
A2A, A3A, A2US, A2USH
A2U, A2USH-S1
Q00CPU, Q01CPU
Q02CPU-A
Q02CPU, Q02HCPU, Q06HCPU, Q12PHCPU, Q25HCPU
Q00JCPU,Q00CPU,Q01CPU,Q02 CPU,Q02HCPU,Q06HCPU,Q12H CPU,Q25HCPU
Q4ACPU, Q4ARCPU, Q3ACPU, Q2ACPU-S1, Q2ACPU
Communication
Type
RS232
RS485 FPG-COM3 (AFPG803)
RS232
RS232
RS485
RS485
RS232
RS232 A0J2-C214-S1 HG9Z-XC145 HG9Z-3C135A
RS485 A0J2-C214-S1
RS485
RS232
RS232
RS485
RS422 Built-in-Port HG9Z-XC255 HG9Z-3C165A
RS232 Built-in-Port HG9Z-XC265 Contact IDEC*Q02CPU
RS232
RS485
Ethernet
RS232 AJ71QC24N-R2 HG9Z-XC145 HG9Z-3C135A
RS485
Ethernet AJ71QE71N3-T Not Supported
Ethernet AJ71QE71N-B2 Not Supported
Ethernet AJ71QE71N-B5 Not Supported
Communication Module
Required
Built-in-Port
FPG-COM1 (AFPG801)
FPG-COM2 (AFPG802)
Built-in-Port
AFP3462
Built-in-Port
AFP3462
AJ71C24-S3/S6/S8 or AJ71UC24
AJ71C24-S3/S6/S8 or AJ71UC24
A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4
A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4
AJ71C24-S6/S8 or AJ71UC24
AJ71C24-S6/S8 or AJ71UC24
A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4
A1SJ71C24-R2/R4 or A1SJ71UC24-R2/R4
QJ71C24, QJ71C24N QJ71C24N-R2
QJ71C24 , QJ71C24N QJ71C24N-R2
QJ71E71-100 QJ71E71-B5 QJ71E71-B2”
AJ71QC24N, AJ71QC24N-R4
HG1F Comm.
Cable P/N
Contact IDEC*
HG9Z-XC145 HG9Z-3C135A
Contact IDEC* Contact IDEC*
HG9Z-XC203 HG9Z-3C145A
Contact IDEC* Contact IDEC*
HG9Z-XC145 HG9Z-3C135A
HG9Z-XC203 HG9Z-3C145A
Contact IDEC* Contact IDEC*
HG9Z-XC203 HG9Z-3C145A
Contact IDEC* Contact IDEC*
Not Supported
Contact IDEC* Contact IDEC*
HG2F/3F/4F Comm.
Cable P/N
HG9Z-2C165A
Contact IDEC*
CAT 5 Ethernet Crossover cable
CAT 5 Ethernet Cross­over cable
CAT 5 Ethernet Cross­over cable
CAT 5 Ethernet Cross­over cable
80
www.idec.com
Operator Interfaces
Cables
OI Touchscreen Family
Manufacturer Series Applicable CPU
Q2ASH CPU-S1, Q2ASHCPU, Q2ASCPU-S1, Q2ASCPU
FX1,FX2,FX2C RS422 Built-in Port HG9Z-XC255 HG9Z-3C165A
FX0,FX0N,FX2N,FX2NC,FX3U C,FX3U
Mitsubishi, continued
Omron SYSMAC-C
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
MELSEC-FX
FX0,FX0N,FX2N,FX2NC,FX3U C,FX3U
FX2N
FX1N
FX3UC, FX3U
CPM1, CPM1A
CPM2A
C500, C500F, C1000H, C2000, C2000H
C1000HF
C200HS
C200HE, C200HG, C200HX
C120, C120F
CQM1H, C200HS­CPU21/23/31/33
Communication
Type
RS232 A1SJ71QC24N-R2 HG9Z-XC203 HG9Z-3C145
RS485 A1SJ71QC24N Contact IDEC* Contact IDEC*
Ethernet A1SJ71QE71N3-T Not Supported
Ethernet A1SJ71QE71N-B2 Not Supported
Ethernet A1SJ71QE71N-B5 Not Supported
RS422
RS422 Built-in Port HG9Z-XC245 Contact IDEC*
RS232 FX2N-232-BD Contact IDEC* Contact IDEC*
RS422
RS232 FX1N-232-BD Contact IDEC* Contact IDEC*
RS422
RS422 Built-in Port HG9Z-XC255 HG9Z-3C165A
RS232
RS232 CPM1-CIF01 HG9Z-XC213 HG9Z-3C155A
RS422 CPM1-CIF11 Contact IDEC* Contact IDEC*
RS232
RS232
RS422
RS422
RS232 C500-LK203 HG9Z-XC155
RS232 C200H-LK201 HG9Z-XC155
RS422
RS422
RS232
RS232 C120-LK201-V1 HG9Z-XC155 HG9Z-3C135A
RS422 C120-LK202-V1 Contact IDEC* Contact IDEC*
RS232 Built-in-Port HG9Z-XC213 HG9Z-3C155A
Communication Module
Required
Built-in Port w/ cable FX­20P-CADP
FX2N-422-BD and FX-20P­CADP
FX2N-422-BD HG9Z-XC245 Contact IDEC*
FX1N-422-BD and FX-20P­CADP
FX1N-422-BD HG9Z-XC245 Contact IDEC*
FX3U-232ADP Contact IDEC* Contact IDEC*
FX3U-232-BD Contact IDEC* Contact IDEC*
Built-in-Port
CPM1-CIF01
C120-LK201-V1
C500-LK203
C120-LK202-V1
C500-LK201-V1
C500-LK203
C200H-LK202
C200HW-COM03/06
C200H-LK201 HG9Z-XC155 HG9Z-3C135A
C200HW-COM02/040/5/06 HG9Z-XC213 HG9Z-3C155A
HG1F Comm.
Cable P/N
HG9Z-XC255 HG9Z-3C165A
HG9Z-XC255 HG9Z-3C165A
HG9Z-XC255 HG9Z-3C165A
HG9Z-XC213 HG9Z-3C155A
HG9Z-XC155 HG9Z-3C135AC500-LK201-V1
Contact IDEC* Contact IDEC*
Contact IDEC* Contact IDEC*
HG2F/3F/4F Comm.
Cable P/N
CAT 5 Ethernet Cross­over cable
CAT 5 Ethernet Cross­over cable
CAT 5 Ethernet Cross­over cable
HG9Z-3C135A
PLCs Operator Interfaces Automation Software Power Supplies Sensors
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
81
Cables
OI Touchscreen Family
Operator Interfaces
Manufacturer Series Applicable CPU
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
SYSMAC-C
Omron con’t
Keyence
GE Fanuc
SHARP New Satellite JW
Hitachi
JTEKT(TOYODA)
Toshiba Machine Works
YASKAWA ELECTRIC CORPORATION
FANUC Power Mate
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
CS1 CS1G, CS1H
CJ1 CJ1M, CJ1H, CJ1G RS232 Built-in-Port HG9Z-XC213 HG9Z-3C155A
Conventional KV KV 10, 16, 24, 40, 80
Visual KV KV-10,16,24,40
KV-700/1000 KV-700, KV-1000
VersaMax Nano/Micro
Series 90-30
S10mini S10mini
S10V LQP510
TOYOPUC-PC2J PC2J RS485 Buit-in Port
TOYOPUC-PC3J
TC200 TC3-13B1 RS232 Buit-in Port
TCmini TC03-01, TC03-02 RS232 Buit-in Port
Machine Controller MP920, MP930, MP2300
C200HE-CPU42, C200HG­CPU43/63, C200HX-CPU44/64
10 I/Os, 14 I/Os
23 I/Os, 28 I/Os
CPU 311, 313, 323, 331, 341, 350, 351, 352, 360, 363, 364, 374
CPU 331, 341, 350, 351, 352, 360, 363, 364, 374
JW-21CU, JW-22CU, JW­31CUH/H1, JW-32CUH/H1, JW-33CUH/H1/H2/H3
JW-50CU/CUH, JW-70CU/ CUH, JW-100CU/CUH
JW-22CU, JW-70CU/CUH, JW-100CU/CUH
JW-32CUH/H1, JW-33CUH/ H1/H2/H3
PC3J RS485 Buit-in Port
PC3JD, PC3JG RS485 Buit-in Port
Power Mate-MODEL D RS422 Buit-in Port
16i, 160i RS232 Buit-in Port
Communication
Type
RS232 Built-in-Port
RS232
RS422 CS1W-SCB41 (port2) Contact IDEC* Contact IDEC*
RS232 Built-in-Port
RS232/485/422 KV-L-20R
RS232 Built-in-Port
RS485 Built-in-Port HG9Z-XC273A
RS485 Built-in-Port
RS232
RS485
RS485 JW-21CM
RS485 JW-10CM
RS232 Built-in Port
RS232
RS485
RS485 Buit-in Port
RS232 LQE160
RS485 LQE165
RS232 LQE560
RS485 LQE565
RS232
RS485
RS232 LQE560
RS485 LQE565
RS232 Buit-in Port
RS232 217IF
Communication Module
Required
Built-in-Port
CS1W-SCB41 (port1)
IC693CMM311
Built-in Port
Buit-in Port
HG1F Comm.
Cable P/N
HG9Z-XC213 HG9Z-3C155A
Contact IDEC*
Contact IDEC*
HG2F/3F/4F Comm.
Cable P/N
Contact IDEC*
Communication & Networking
82
www.idec.com
Operator Interfaces
Cables
OI Touchscreen Family
Manufacturer Series Applicable CPU
FA-M3(F3SP05, F3SP20, F3SP21, F3SP25, F3SP30, F3SP35, F3SP38, F3SP53,
YOKOGAWA FA-M3
FLEX-PC
FUJI
MICREX-F
PROSEC T Series
Toshiba
V Series
LS Industrial Systems
1. * Consult IDEC for wiring schematic and cable.
2. Visit www.idec.com/oi for the most up-to-date list of cables.
MASTER-K
F3SP58, F3FP36, F3BP20, F3BP30)
FA-M3(F3SP05, F3SP21, F3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58)
NB1, NB2, NB3, NJ-CPU-E4, NJ-CPU-A8, NJ-CPU-B16, NS
F55 RS232 NV1L-RS2
F70
F80H, F120H, F120S, F140S, F150S
F30, F50, F50H, F55, F60, F70, F70S, F80H, F81, F120H, F120S, F140S, F150S, F250
T1: T1-16,T1-28,T1-40
T1S: T1-40S
T2: PU224 RS485 Buit-in Port
T2E: PU234E
T2N: PU215N,PU235N, PU245N
T3/T3H: PU315, PU325, PU325H, PU326H
S2I/ S2E/L1/S2/S3: PU672T, PU662T, PU612E, L1PU11H,L1PU12H, S2PU82, S2PU72, S2PU32, S2PU22, S3PU65, S3PU55, S3PU45, S3PU21
K10S1 RS232 Buit-in Port
K80S, K120S, K200S RS232 Buit-in Port
K80S
K200S
K300S RS232 G4L-CUEA
Communication
Type
RS232 F3LC11-1N
RS485 F3LC11-2N
RS232 Buit-in Port
RS232
RS485
RS232
RS485
RS232 NJ-RS2
RS485 NJ-RS4
RS232
RS485
RS232 NC1L-RS2
RS485 NC1L-RS4
RS232
RS485
RS232
RS485
RS232 Buit-in Port
RS485 CU111
RS232
RS485
RS485 CU111
RS232 Buit-in Port
RS485 CM231E
RS232 CM232E
RS232
RS485
RS485 Buit-in Port
RS485 Buit-in Port
RS232 G7L-CUEB
RS232 G7L-CUEC
RS232 G6L-CUEB
RS232 G6L-CUEC
Communication Module
Buit-in Port
NB-RS1-AC/DC
NS-RS1
FFU120B
FFK120A-C10
Buit-in Port
Buit-in Port
Required
HG1F Comm.
Cable P/N
Contact IDEC* Contact IDEC*
HG2F/3F/4F Comm.
Cable P/N
PLCs Operator Interfaces Automation Software Power Supplies Sensors
Communication & Networking
USA: 800-262-IDEC Canada: 888-317-IDEC
83
OI Touchscreen Family
Operator Interfaces
Specifi cations
General Specifi cations
Model HG1F HG2F HG3F HG4F
Voltage 24V DC
Voltage Range 20.4 to 28.8V DC 19.2 to 28.8V DC
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
Power Consumption 10W maximum 25W maximum
Inrush Current 20A maximum 15A maximum (cold start)
Allowable Momentary Power Interruption 10 ms minimum
Dielectric Strength 1,000V AC, 10 mA, 1 minute between power and FG terminals 1,500V AC, 10 mA, 1 minute between power and FG terminals
Insulation Resistance
Backup Battery
Operating Temperature 0 to 50°C (no freezing) 0 to 45°C (no freezing)
Operating Humidity 10 to 90% RH (no condensation) 10 to 95% RH (no condensation) 20 to 85% RH (no condensation)
Storage Temperature –20 to +60°C (no freezing)
Storage Humidity 10 to 90% RH (no condensation) 10 to 95% RH (no condensation) 20 to 85% RH (no condensation)
Pollution Degree 2 (IEC 60664-1)
Corrosion Immunity Atmosphere free from corrosive gases
Vibration Resistance (damage limits) 10 to 20Hz amplitude 0.625 mm, 20 to 55Hz acceleration 9.8 m/s
Shock Resistance (damage limits) 147 m/s2 (15G), 11 ms, 5 shocks on each of three mutually perpendicular axes
Noise Immunity Fast transient/burst test, common mode: Level 3, power terminals: ±2 kV, communication line: ±1 kV (IEC/EN 61000-4-4)
Electrostatic Discharge ESD-3 (RH-1), Level 3, (contact ±6 kV, aerial ±8 kV) (IEC/EN 61000-4-2)
Mounting Panel mounting
Degree of Protection IP65 NEMA TYPE 13 IP66 NEMA TYPE 4, 4X, 13
Dimensions (mm) 147W x 47H x 39.3D 172W x 136H x 56D 324W x 240H x 56D 348W x 270H x 58D
Weight (approx.) 280g 800g 2800g 3400g
50 MΩ minimum between power and FG terminals
(500V DC megger)
CR2032 lithium batteryy
Life approx. 4 years (25ºC)
2
(1G), 2 hours per axis on each of three mutually perpendicular axes
Operation Specifi cations
Model HG1F
Switching Element Resistive membrane
Touch Region Resolution 1 x 1 16 x 12 16 x 8 32 x 24 40 x 30
CC Switch Quantity 4 x 1 row (bottom only)
Operating Force 0.2 to 0.8N 2.5 to 5.0N 0.2 to 0.8N 0.2 to 0.8N
Mechanical Life 1,000,000 operations
Acknowledge Sound Electronic buzzer
Screen Types Base screen, popup screen, system screen
Number of Screens
User Memory 1MB (including expansion fonts) 2MB 8MB*
Parts
Calendar Year, Month, Day, Hour, Min., Sec., Day of Week
Print Function (support)
Power Failure Backup Backup data: Calendar, log data, keep internal relay, keep internal register
Backup Duration 1 month (at 25°C) after full charging for two days
Battery Life 4 years (at 25ºC)
*2MB for OS
Base screen: 3000 max.,
popup screen: 3015 max.
Bit Button, Word Button, Goto Screen Button, Print Button, Key Button, Keypad, Selector Switch, Potentiometer, Numerical Input, Character Input, Pilot Lamp, Multi-state Lamp, Picture Display, Message Display, Message Switching Display, Alarm List Display, Alarm Log Display, Numerical Display, Bar Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write Command, Word Write Command, Goto Screen Command, Timer, Print Command, Screen Script Command
ESC/P, PC-PR: Epson VP-700
Standard CC Switch Option
SII: DPU414
Communication & Networking
HG2F
Base screen: 3000 max., popup screen: 3000 max.
10 MΩ minimum between power and FG terminals
(500V DC megger)
HG3F HG4F
ESC/P, PC-PR, PCL, EPSON LP2500/VP-700/PX-V600/
Stylus C83, C84, C87, C88, D88, HP Deskjet 3820
84
www.idec.com
Operator Interfaces
OI Touchscreen Family
Display Specifi cations
Model HG1F
LCD Monochrome STN Color STN Monochrome STN Color TFT
Effective Display Area (mm)
Display Resolution 300W x 100H 320W x 240H pixels 640W x 480H pixels 800W x 600H pixels
LCD Life 50,000 hours minimum 100,000 hours minimum 60,000 hours minimum
Contrast Adjustment Possible in steps using the front touch screen
Backlight Cold-cathode tube Cold-cathode tube (2 tubes)
Backlight Life
Backlight Control Automatic OFF
Backlight Replacement Possible
1/4 size
Display Character Size
Quantity of Characters
Character Magnifi cation 0.5, 1, 2, 3, 4, and 8 vertically and horizontally
Character Attribute Blink (1 or 0.5 sec period), reverse, bold, shadowed
Graphics Type Straight line, polyline, polygon, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image
Window Display 3 popup screens + 1 system screen
Note: The backlight life refers to the time until the surface brightness reduces to a half after using continuously at room temperatures.
1/2 size
Full size 16 x 16 pixels (Japanese JIS fi rst and second level characters, simplifi ed Chinese, traditional Chinese, Korean)
Double size
1/4 size 37 characters x 12 lines
1/2 size 37 characters x 6 lines 40 characters x 15 lines (40 x 10, cc click type) 80 characters x 30 lines 100 characters x 37 lines
Full size 18 characters x 6 lines 20 characters x 15 lines (20 x 10, cc click type) 40 characters x 30 lines 50 characters x 37 lines
Double size
115W x 39W 118.2W x 89.4H 211.2W x 158.4H 246W x 184.5H
50,000 hours nominal
(Note)
8 x 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250,
8 x 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250,
9 characters x 3 lines 10 characters x 7 lines (10 x 5, cc click type) 20 characters x 15 lines 25 characters x 18 lines
Color Monochrome Color Color
40,000 hours nominal (Note) 50,000 hours nominal (Note)
16 x 32 pixels, 24 x 48 pixels, 32 x 64 pixels (Western European language: ISO 8859-1)
32 x 32 pixels (Japanese JIS fi rst level characters, Mincho font)
40 characters x 30 lines
(40 x 20, cc click type)
HG2F HG3F HG4F
Japanese katakana and symbols: JIS 8-bit code)
Japanese katakana and symbols: JIS 8-bit code)
80 characters x 60 lines 100 characters x 75 lines
PLCs Operator Interfaces Automation Software Power Supplies Sensors
USA: 800-262-IDEC Canada: 888-317-IDEC
Communication & Networking
85
OI Touchscreen Family
Operator Interfaces
Interface Specifi cations
CF Card Interface Specifi cations Parallel Interface Specifi cations (HG3F/4F) Ethernet Specifi cations (HG3F/4F)
Interface Specifi cations Compact Flash Type I standard compliant* IEEE 802.3 standard compliant, 10Base-T
Electrical Characteristics Centronics interface compliant
Connector 50-pin compact fl ash card connector D-sub 25-pin female connector
PLCsOperator InterfacesAutomation SoftwarePower SuppliesSensors
*Memory size supports up to 512MB.
Interface Specifi cations
RS232C
Electrical Characteristics EIA RS232C compliant
Transmission Speed
Synchronization Asynchronous
Communication Method Half or full duplex
Control System Hardware control or none
Connector D-sub 25-pin female connector
Electrical Characteristics EIA RS485 (422) compliant
Transmission Speed
Synchronization Asynchronous
Communication Method Half or full duplex
Control System Hardware control or none
Connector D-sub 25-pin female connector
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
RS485 (422)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Electrical Characteristics EIA RS232C compliant
Transmission Speed 9600, 19200, 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half duplex, proprietary protocol
Connector Mini DIN 8-pin connector
Electrical Characteristics EIA RS485 compliant
Transmission Speed 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half duplex, proprietary protocol
Connector Special connector
Maintenance Communication
OI Link Communication
Expansion Unit (Digital I/O Unit)
Applicable Quantity 1
Mounting Style Mounted on the rear of the HG unit
Input Points 16
Voltage 12 to 24V DC (allowable range 10 to 28V DC)
Input
Isolation Method Photocoupler
Output Points 16
Load Voltage 12 to 24V DC (allowable range 10 to 28V DC)
Isolation Method Photocoupler
Output Signal NPN open collector
Output
Output ON Voltage 1.6V maximum
Output Current 30 mA max. per point, 200 mA total
Connector
24-pin connector (Fujitsu FCN-365P024-AG) 2 connectors for inputs and outputs
Communication & Networking
86
www.idec.com
Operator Interfaces
Mounting Clip
Mounting Clip
HG2F
Panel
162.5
+0.5
0
126.5
+0.5
0
Panel thickness: 1.6 to 5mm
OI Touchscreen Family
Dimensions & Panel Cutouts
HG1F Dimensions HG1F Installation Panel Layout
+1.5
137
0
147mm
76mm
65.8mm
+1
0
66
Mounting Clip
PLCs Operator Interfaces Automation Software Power Supplies Sensors
136.8mm
4mm
Panel thickness: 1.6 to 5m
39.3mm
m
HG2F Dimensions HG2F Installation Panel Layout
172mm
162mm
136mm
6mm
56mm
126mm
HG3F Dimensions HG3F Installation Panel Layout
Panel
+0.5
302
0
301mm
240mm
+0.5
0
228
Mounting Clip
Mounting Clip
324mm
301mm
6mm
55.8mm
Panel thickness: 2 to 5mm
HG4F Dimensions HG4F Installation Panel Layout
+1
332
0
331mm
All dimensions in mm.
348mm
331mm
270mm
6mm
58mm
+1
0
258
Panel thickness: 2 to 5mm
USA: 800-262-IDEC Canada: 888-317-IDEC
HG3F
Mounting Clip
Mounting Clip
Panel
Communication & Networking
HG4F
Mounting Clip
87
Loading...