IDEAL Response SE User Manual

2
Response SE - User's
Response SE:
The super efficiency combi boiler
The Ideal Response SE is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers instant hot water on demand. It has been designed to be 'friendly' to the user, installer and service engineer.
Response SE: The fit anywhere combi
Simple fanned 'go anywhere' flue
The Response SE's flue turret simply rotates through 360° to allow horizontal outlet in any direction. Options include horizontal flue length extensions or simple vertical flue kits - and the flue is self-sealing, eliminating the need for outside assembly, an important benefit in high­rise applications.
Downward or upward connections...
Water and gas connections have been designed to be as simple and fast as possible. The Ideal Response SE comes complete with a rugged mounting frame which can accommodate downward or upward routed gas, water and electrical connections before the boiler is fitted.
...and it fits inside a cupboard
Its compact size makes the Response SE ideal for any kitchen. It can be installed inside a cupboard without any ventilation.
Response SE: The combi you can rely on
The Response SE has been designed and developed with reliability as the number one priority. But even the finest engineered product may develop a fault at some stage in its lifetime. To support the Response SE we've created the Ideal Care Guarantee which sets out our target to repair any fault next day.
Free Guarantee: 1st Year Ideal Care
The home owner is entitled to 12 months free Ideal Care, which includes both parts and labour, to restore the boiler to full function. Please encourage the home owner to complete and return the registration form in their Householder's pack within 30 days of installation.
Optional Extra Year Cover with Ideal Care
You may wish to offer your own annual service plan or you may wish to advise the home owner to complete their application form for the appropriate level of extended Ideal Care - Silver, Gold or Platinum. Full details are available in the Ideal Care brochure.
3
Response SE - User's
RESPONSE SE (Natural Gas Models Only) G.C. Appliance No.47 348 03
Gastec Certified - P.I. No. 0063 AS 3355 Destination Countries: GB, IE
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
4
Response SE - User's
BOILER CONTROLS
Introduction
The Response SE is a wall mounted, room sealed, super efficient condensing combination boiler, featuring full sequence automatic spark ignition and fan assisted combustion.
Due to the very high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through the plastic waste pipe at the left lower rear of the boiler. A condensate 'plume' will also often be visible at the flue terminal.
The Response SE is a combination boiler providing both central heating and instantaneous domestic hot water.
Gas safety (Installation & Use) Regulations 1994, amendments 1996 or rules in force.
In your own interest, and that of safety, it is the law that this boiler must be installed by a registered installer, in accordance with all national and local regulations.
It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.
Electricity Supply
Connection must be made in a way that allows complete isolation of the electrical supply such as a double pole switch having a 3mm (1/8") contact separation in both poles, or a plug and socket, serving only the boiler and system controls. The means of isolation must be accessible to the user after installation, The fusing should be 3A.
Legend
A Control door
B Control panel
C On/off switch
D Central heating on/off switch
E Central heating pressure gauge
IMPORTANT
THIS APPLIANCE MUST NOT BE OPERATED WITHOUT THE CASING CORRECTLY FITTED.
If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.
Clearances of 180mm above, 100mm below, 5mm at the sides and 450mm at the front of the boiler casing must be allowed for servicing.
If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a registered installer.
To light the boiler
(see illustration below)
1. Check that the electricity supply to the boiler is OFF.
2. Open the controls access door .
3. Set the on/off switch (C) and CH switch (D) to OFFand
ensure that all DHW taps are turned off.
4. Switch ON the electricity supply to the boiler and check that all external controls, e.g. programmer, room thermostat, etc., are ON.
If a programmer is fitted, refer to the separate instructions provided.
5. Set the on/off switch (C) to ON and CH switch (D) to the desired position.
The boiler will first execute a self-check cycle then commence the ignition sequence, first supplying heat to preheat the domestic hot water and then to the central heating, if required.
5
Response SE - User's
Frost protection
This is provided automatically by the boiler control unit. If frost is likely during an absence from home, turn the boiler off at the time switches ONLY, leaving the mains supply switched ON.
If the boiler flow temperature falls below 7
o
C the pump will run,
without the boiler firing, until the temperature exceeds 10
o
C.
If the flow temperature falls below 3
o
C the boiler will fire until the
temperature exceeds 10 oC.
Fault condition
If the boiler will not light initially or if a fault develops during normal operation, the first digit and the last 2 digits of the display will flash alternately. In this event press the RESET button and the boiler will recommence the ignition cycle.
If the fault condition persists, turn the boiler OFF and consult your local registered installer.
Loss of system water pressure
The gauge (E) on the control panel indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar over a period of time then a water leak is indicated. In this event consult your local registered installer.
DO NOT OPERATE THE BOILER IF THE PRESSURE HAS REDUCED TO ZERO FROM THE ORIGINAL SETTING.
Escape of gas
Should a gas leak be suspected contact your local gas supplier IMMEDIATELY.
Do NOT search for gas leaks with a naked flame.
Condensate drain
The condensate drain must NOT be modified or blocked.
Blockage caused by debris or freezing can cause automatic shutdown of the boiler.
If freezing is suspected and the pipe run is accessible, an attempt may be made to free the obstruction by pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe. If this fails to remedy the problem seek advice from your local registered installer.
Cleaning
For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a registered installer, local gas authority or registered service organisation.
Note. In the normal running STANDBY mode, the left hand display digit indicates the boiler sequence and the other 2 digits the boiler flow temperature.
Sequence Boiler Status
0 Standby - no heat request
1 Purge
2 Ignition
3 Burner on - CH
4 Burner on - DHW
6. Close the controls door.
Operation
WINTER CONDITIONS - i.e. CH and DHW required.
Set the CH switch (D) to ON.
The boiler will fire and supply heat to the radiators but will give priority to DHW on demand.
The DHW preheat will operate as described under 'Summer conditions' during periods when there is no call for CH.
SUMMER CONDITIONS - i.e. DHW only required.
Set the CH switch (D) to OFF.
The boiler will fire for approximately one minute, to preheat the DHW heat exchanger and thereafter fire periodically for a few seconds in order to maintain the temperature.
Control of water temperature
DOMESTIC HOT WATER
The DHW temperature is limited by the boiler controls to 60 oC maximum at low draw-off rate.
Additionally, the temperature is controlled by the user via the draw-off tap : the lower the rate the higher the temperature, and vice versa.
CENTRAL HEATING
The boiler controls the central heating radiator temperature to a maximum of 82 oC
DOMESTIC HOT WATER & CENTRAL HEATING
To return the boiler to normal running STANDBY mode press the RESET button.
To shut down the boiler
1. For short periods
Set the CH switch (D) to OFF.
2. For longer periods
Set the on/off switch (C) and CH switch (D) to OFF, and switch the electricity supply to OFF.
THE LOG BOOK SHOULD BE COMPLETED AFTER
EACH SERVICE AND KEPT WITH THESE
INSTRUCTIONS
6
Response SE - User's
Ideal Consumer Helpline
Tel: 01482 498 660
Caradon Plumbing Limited pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.
September 1999 UIN 151 397 A02
Caradon Plumbing Limited, P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN. Telephone: 01482 492 251 Fax: 01482 448 858. Registration No. London 322
137. Registered Office: National Avenue, Kingston upon
Hull, HU5 4JN. A subsidiary of Caradon p.l.c
The code of practice for the installation,
commissioning & servicing of central heating systems
Caradon Plumbing Limited is a member of the
Benchmark initiative and fully supports the aims of the
programme. Benchmark has been introduced to
improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.
7
Response SE - User's
Your feedback
and your chance to win a free boiler
At Ideal we've been leaders in the design and engineering of robust and reliable boilers for over 90 years. We want to continue as leaders by listening to your suggestions for how to improve our boilers and our service. We will be giving away a free boiler for the five best ideas every year (to be selected by our Technical Director). Please complete this form, using extra sheets if required, and post it or fax it to us on 01482 498699.
Boiler details
Model / Size (e.g. Classic RS 230, Mexico CF 60 etc. Details on control panel door)
Date of Installation
Installer details
Name
Address
Post Code Telephone (Please include STD code)
How I would improve this boiler:
:
My general comments for Ideal:
Ideal Consumer Helpline
Tel: 01482 498 660
Caradon Plumbing Ltd, PO Box 103, National Avenue, Kingston upon Hull, HU5 4JN. Telephone: 01482 492251 Fax: 01482 448858.
UIN 151 397 A0
Further information
If you would like information about Ideal Boilers please complete this sheet and fax it to us on 01482 498699 or post it to Caradon Plumbing Limited, PO Box 103, National Avenue, Kingston upon Hull, HU5 4JN.
Installer details
Name
Address
Post Code Telephone (Please include STD code)
General information required
Please send me details of Ideal Training Courses.
Please arrange for a technical representative to contact me.
Please arrange for me to join an Ideal factory tour.
Range guides required
The Ideal Guide: a specifier's and installer's introduction to the Ideal domestic boiler range.
The Ideal Householders Guide: to assist the installer when presenting to his/her customers.
Technical manuals required
The Ideal C class combi boiler
The Ideal Classic wall hung boiler
The Ideal Classic System wall hung boiler
The Ideal Classic LX Deluxe wall hung boiler
The Ideal Mexico floor standing boiler
The Ideal Minimiser heat-saving boiler
The Ideal Response combi boiler
The Ideal Response SE super efficiency combi boiler
The Ideal Systemiser SE super efficiency system boiler
The Ideal Concord high output boiler
The Ideal Buccaneer oil fired boiler
Ideal Consumer Helpline
Tel: 01482 498 660